This solicitation is for multiple award indefinite delivery indefinite quantity contracts for mechanical construction services at the National Institute of Standards and Technology located in Gaithersburg, Maryland. The scope of work includes maintenance, installation, and repair of air distribution, exhaust, heating, domestic water, natural gas, refrigeration, steam, and condensate systems. Typical maintenance activities may include equipment repairs, filter replacement, and control system adjustments. Construction services include demolition, repair, replacement, modification, or addition to hydronic, plumbing, refrigeration, steam/condensate, and HVAC systems. Individual task orders will have periods of performance identified in the scope of work. The base period of the contracts is 365 days with four additional ordering periods. The cumulative task order amount shall not exceed $8 million per contract. Task order amounts are expected to range from $2,500 to $1.5 million. Award will be made to responsible offerors providing the best value based on technical rating and price, though lowest price is not a determining factor.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 1 to 1333ND20QNB190030.pdf | ||
| FormSF1442.pdf | ||
| NIST - OFPM Guidelines for Contractors.pdf | ||
| Bid Sheet - 5 Buildings.pdf | ||
| NIST Bldg 301 - Provide Demand Potable Water Meters Final.pdf | ||
| NIST Bldg 101 - Provide Demand Potable Water Meters Final.pdf | ||
| NIST Bldg 226 - Provide Demand Potable Water Meters Final.pdf | ||
| MD20200043 Wage Determination.pdf | ||
| SPECS - NIST Potable Water.pdf | ||
| SOW - Metering Project_041620.pdf | ||
| NIST Bldg 215 - Provide Demand Potable Water Meters Final.pdf | ||
| PAST PERFORMANCE QUESTIONNAIRE.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE TO BIDDERS
YOUR WORK IN THIS BUILDING MAY DISTURB ASBESTOS-CONTAINING
MATERIALS. IF YOU SUSPECT MATERIAL IN YOUR WORK AREA MAY CONTAIN
ASBESTOS COORDINATE AT 301-975-6999 FOR IDENTIFICATION AND REMOVAL.
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
O T
S
C A
L E
P
L O
T
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
N
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
N I S
T
G A
I T
H E
R S
B U
R G
M
D
F I N
A L
S
U B
M I S
S I
D E
M A
D
P
T
A B
L E
W A
T E
R
M
E T
E R
I N
G
O F
P M
C F
R
E
N G
I N
E E
R I
G
E
R M
A N
T O
W N
M
C
E N
T U
R Y
B
L V
D
C F
R
E
N G
I N
E E
R I N
G
A
L E
N F
E
G
N F
E
G
X
20251 CENTURY BLVD # 120
GERMANTOWN, MD 20874
CFR ENGINEERING
P0.01
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
DRAWING LIST
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
VICINITY MAP
AutoCAD SHX Text
BUILDING 222
AutoCAD SHX Text
CHEMISTRY BUILDING
AutoCAD SHX Text Gaithersburg
AutoCAD SHX Text Rockville
AutoCAD SHX Text Aspen Hill
AutoCAD SHX Text Silver Spring
AutoCAD SHX Text Bethesda
AutoCAD SHX Text Washington
AutoCAD SHX Text Arlington
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Oakton
AutoCAD SHX Text Coral Hills
AutoCAD SHX Text Annandale
AutoCAD SHX Text
PROJECT SITE
AutoCAD SHX Text Diamond Avenue
AutoCAD SHX Text Muddy Branch Road
AutoCAD SHX Text Quince Orchard Road
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SITE
AutoCAD SHX Text
SITE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GATE "F"
AutoCAD SHX Text
GATE "E"
AutoCAD SHX Text
MUDDY BRANCH ROAD
AutoCAD SHX Text I-270
AutoCAD SHX Text
TO WASHINGTON
AutoCAD SHX Text I-270
AutoCAD SHX Text
SOUTH DRIVE
AutoCAD SHX Text
EAST DRIVE
AutoCAD SHX Text
WASHINGTON
AutoCAD SHX Text
NATIONAL
AutoCAD SHX Text
PIKE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
CHEMICAL
AutoCAD SHX Text
COOLING TOWER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TOWNHOUSE
AutoCAD SHX Text
HERCOFORM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STATE ROAD 124
AutoCAD SHX Text
SEPARATOR
AutoCAD SHX Text
ISOTOPE
AutoCAD SHX Text
VAULT
AutoCAD SHX Text
ELEC.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE DRIVE
AutoCAD SHX Text
GATE "C"
AutoCAD SHX Text
AutoCAD SHX Text
CENTER DRIVE
AutoCAD SHX Text
STACK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WEST DRIVE
AutoCAD SHX Text
AutoCAD SHX Text
QUINCE
AutoCAD SHX Text
ORCHARD
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
SUBSTATION
AutoCAD SHX Text
GATE
AutoCAD SHX Text
PEPCO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TO FREDERICK
AutoCAD SHX Text
GATE "A"
AutoCAD SHX Text
GATE "B"
AutoCAD SHX Text
BUREAU DR.
AutoCAD SHX Text
NORTH ROAD
AutoCAD SHX Text
AutoCAD SHX Text
SOUTH DRIVE
AutoCAD SHX Text
MUDDY BRANCH ROAD
AutoCAD SHX Text
DIAMOND AVENUE WEST
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text "D"
AutoCAD SHX Text
DEMAND POTABLE WATER METERING
AutoCAD SHX Text
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY
AutoCAD SHX Text
FINAL SUBMISSION
AutoCAD SHX Text
SHEET LIST TABLE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
NIST #
AutoCAD SHX Text
AutoCAD SHX Text
DEMAND POTABLE WATER METERING-COVER SHEET
AutoCAD SHX Text 222-787
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P0.01
AutoCAD SHX Text P0.02
AutoCAD SHX Text P1.01
AutoCAD SHX Text
AutoCAD SHX Text P5.01
AutoCAD SHX Text
DEMAND POTABLE WATER METERING-GENERAL NOTES, SCOPE, ABBREV, AND SYMOBLS
AutoCAD SHX Text
DEMAND POTABLE WATER METERING-PLUMBING/ELECTRICAL
AutoCAD SHX Text
DEMAND POTABLE WATER METERING-P/E-DETAILS & CONTROLS DIAGRAM
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
NIST# 222-787
AutoCAD SHX Text 222-788
AutoCAD SHX Text 222-789
AutoCAD SHX Text 222-790
ABV
AHU
AD
AFF
BAS
BHP
CLG
CP
CW
DDC
ABOVE
AIR HANDLING UNIT
ACCESS DOOR
ABOVE FINISHED FLOOR
BUILDING AUTOMATION
SYSTEM
BRAKE HORSEPOWER
CEILING
CONDENSATE PUMP
DOMESTIC COLD WATER
DIGITAL DATA CONTROL
1. ASSEMBLE AND INSTALL CONNECTIONS, TUBING, AND ACCESSORIES BETWEEN
FLOW-MEASURING ELEMENTS AND FLOWMETER DEVICES ACCORDING TO
MANUFACTURER'S WRITTEN INSTRUCTIONS. INSTALL FLOWMETER ELEMENTS IN
ACCESSIBLE POSITIONS IN PIPING SYSTEMS.
2. FOR METERING DEVICE TYPE, PERFORMANCE REQUIREMENTS, AND SPECIFICATION
REFER TO DIVISION 23 INSTRUMENTATION AND CONTROLS FOR ADDITIONAL
INFORMATION AND INSTALLATION.
3. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD
PRIOR TO UNDERTAKING ANY WORK. NOTIFY COTR IF THERE ARE SUBSTANTIAL
DIFFERENCES THAT MIGHT REQUIRE DESIGN MODIFICATIONS.
4. DRAWINGS DO NOT SHOW ALL CONSTRUCTION AND FABRICATION DETAILS. HOWEVER,
ALL SUCH WORKS ARE REQUIRED AND SHALL BE PROVIDED TO COMPLETE THE
INSTALLATION AT NO ADDITIONAL COST TO THE GOVERNMENT.
5. STORE MATERIALS IN AREAS DESIGNATED BY THE COTR PRIOR TO INTERRUPTION OF
UTILITIES AND SERVICES.
6. ALL LOGIC CONTROLLERS REQUIRE A 120 VAC POWER SOURCE, PROVIDED BY
DIVISION 26 ELECTRICAL CONTRACTOR. CIRCUIT BREAKER SHALL BE A DEDICATED 120
VAC, 20 AMP, CIRCUIT. A MAXIMUM OF (3) METERING DEVICES AND/OR LOGIC
CONTROLLERS MAY BE POWERED FROM ONE BREAKER.
7. LOGIC CONTROLLER AND REMOTE METERING DISPLAY WHEN REQUIRED SHALL BE
MOUNTED IN CABINET ON A FIELD FABRICATED UNISTRUT FRAME OR WALL OR
COLUMN IN CLOSE PROXIMITY OR ADJACENT TO THE RESPECTIVE METERING DEVICE.
EXACT LOCATION OF REMOTE METERING DISPLAY AND LOGIC CONTROLLER SHALL BE
FIELD COORDINATED.
8. SHUT DOWN OF EXISTING SYSTEM SHALL BE SCHEDULED AND COORDINATED WITH
COTR PRIOR TO ANY SHUTDOWN OR INTERRUPTION OF SERVICE.NOTIFY COTR A
MINIMUM OF 10 DAYS IN ADVANCE BEFORE WORK IS TO BEGIN. SHUT DOWN/ AND
INTERRUPTIONS OF THE SYTEM SHALL BE KEPT TO A MINIMUM UNLESS OTHERWISE
STATED BY COTR.
9. THE CONTRACTOR SHALL INSTALL ALL WIRING AND CABLE WITH EMT CONDUIT.
10. THE CONTRACTOR TO PROVIDE PULL STRING INSIDE THE EMT CONDUIT FOR NIST
FUTURE USE.
11. IT SHALL BE NOTED THAT THE WORD "PROVIDE" MEANS FURNISH AND INSTALL. THE
WORD "PIPING" MEANS PIPE FITTINGS, CONTROL, VALVES, AND NECESSARY FOR A
COMPLETE SYSTEM.
12. CONTRACTOR SHALL CONTACT THE NIST COTR FOR NOTICE TO PROCEED WITH WORK
IN EACH BUILDING. NIST WILL SELECT THE BUILDING TO BE DONE AND NOTIFY THE
CONTRACTOR. UPON COMPLETION OF WORK, EACH BUILDING WILL BE TURNED OVER
TO NIST FOR VERIFICATION AND TESTING.
1. THE WORK SHALL CONSIST OF FURNISHING AND INSTALLING DOMESTIC WATER
FLOWMETER(S) AT THE LOCATION(S) SHOWN ON THE PLANS.
2. THE METER SHALL BE OF THE TYPE AND BRAND SPECIFIED, OR AN APPROVED
EQUIVALENT. THE METER SHALL BE HIGH DEGREE OF ACCURACY AND REPEATABILITY
MEASURING WITHIN AN ACCURACY OF +/- 1% OF ACTUAL FLOW AND +/- 0.5%
REPEATABILITY.
3. THE CONTRACTOR SHALL UTILIZE THE EXISTING NETWORK DDC BACNET CONTROL TO
COMMUNICATE THE SIGNALS FROM THE METER TO THE HEAD COMPUTER. THE
CONTRACTOR SHALL INSTALL THE COPPER AND/OR FIBER CONNECTION FROM THE
METER TO THE EXISTING BACKBONE WITHIN THE BUILDING. THE USE OF UNITARY
CONTROLLERS AND GLOBAL CONTROLLERS ARE ACCEPTABLE AND CAN BE
INCORPORATED IN THE EXISTING COMMUNICATION SYSTEMS AS REQUIRED. DATA
COLLECTION SYSTEM SHALL COLLECT AND STORE DATA SAMPLES IN 15 MIN INTERVALS.
ADDITIONALLY, THE FLOW DATA SHALL BE TOTALIZED AND RECORDED AT THE SAME 15
MIN INTERVAL. FLOW DATA FOR THE MONTH SHALL BE TOTALIZED AND REPORTED
MONTHLY IN ADDITION TO BEING DISPLAYED ON THE EXISTING METER CONTROLLER
VIEWPORT. DATA AND GRAPHICS SHOULD BE REPORTED TO THE BAS SERVER (BUILDING
219), THE A/C SHOP WORKSTATION (BUILDING 301), THE CENTRAL PLANT (BUILDING 302),
AND 3 LAPTOPS. THE GRAPHICS FOR EACH OF THESE WORKSTATIONS MUST BE
CHANGED LOCALLY. COR WILL IDENTIFY THE LOCATION OF EACH LAPTOP.
4. THE MANUFACTURER'S RECOMMENDATIONS FOR THE INSTALLATION OF THE FLOW
METER SHALL BE OBTAINED PRIOR TO INSTALLATION, AND A COPY SHALL BE SUPPLIED
TO THE COTR PROJECT OFFICE. THE RECOMMENDATIONS SHALL INCLUDE THE
REQUIREMENTS FOR STRAIGHT PIPE DISTANCE BOTH UPSTREAM AND DOWNSTREAM OF
THE METER. THESE DISTANCES SHALL BE DETAILED FOR VARIOUS APPURTENANCES,
SUCH AS ELBOWS, VALVES, SUDDEN ENLARGEMENTS, AND CONTRACTIONS. THE METER
SHALL BE PLACED IN THE PIPE IN A POSITION, WHICH IS CORRECT FOR THE PIPE
DIAMETER WALL THICKNESS. IN THE ABSENCE OF MANUFACTURES' RECOMMENDATIONS
FOR STRAIGHT PIPE, DISTANCE UP AND DOWNSTREAM OF THE METER, GENERAL
REQUIREMENTS FOR THE LOCATION OF THE METER ARE PER DETAIL ON SHEET P5.01
DETAILS, SCHEMATICS & CONTROL DIAGRAM SHEET.
5. THE CONTRACTOR SHALL INSURE THAT THE FLOWMETER IS FUNCTIONING PROPERLY AT
THE TIME OF INSTALLATION. THE METER SHALL BE EXAMINED WITH WATER FLOW
THROUGH THE PIPE TO DETERMINE IF THE METER IS FUNCTIONING PROPERLY AND
ACCURATELY MEASURING WATER. IF OPERATION PROBLEMS, ABNORMAL FLUCTUATIONS
IN READING, OR OTHER DEFICIENCIES OCCUR, THE INSTALLATION SHALL BE
RE-EVALUATED AND THE CAUSE OF THE PROBLEM AND/OR DEFICIENCIES SHALL BE
CORRECTED. THE MANUFACTURER'S RECOMMENDATIONS FOR MAINTENANCE SHALL BE
OBTAINED.
DN
E
UP
US ULTRA SONIC FLOW METER
X ITEMS TO BE REMOVED
DOWN
ITEMS TO REMAIN EXISTING
UP
NEW WORK PLAN NOTE INDENTIFICATION
END OF DEMOLITION
POINT OF CONNECTION
EXISTING TO BE REMOVED
EXISTING TO REMAIN
NEW WORK
PIPE TURNED DOWN
PIPE TURNED UP
EXISTING FLOW METER
ULTRASONIC FLOW METER
BACKFLOW PREVENTOR
JUNCTION BOX
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
P
L O
T
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
N I S
T
G A
I T
H E
R S
B U
R G
M
D
F I N
A L
S
U B
M I S
S I
D E
M A
T
A B
L E
W A
T E
R
M
E T
E R
I N
G
O F
P M
C F
R
E
N G
I N
E E
R I
R M
A N
T O
W N
C
E N
T U
V
D
C F
R
E
N G
I N
E E
R I N
G
A
L E
N F
E
G
N F
E
G
X
N I S
P0.02
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SITE
AutoCAD SHX Text
SITE
AutoCAD SHX Text
PLUMBING ABBREVIATIONS
AutoCAD SHX Text
PLUMBING SYMBOLS
AutoCAD SHX Text
AutoCAD SHX Text U
AutoCAD SHX Text
SCOPE OF WORK
AutoCAD SHX Text
INSTALLATION NOTES
AutoCAD SHX Text M
AutoCAD SHX Text J
AutoCAD SHX Text
NORTH
GEN NOTES,SCOPE, ABBREV, SYMBOLS
AREA OF WORK
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
P
L O
T
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
N I S
T
G A
I T
H E
R S
B U
R G
M
D
F I N
A L
S
U B
M I S
S I
D E
M A
T
A B
L E
W A
T E
R
M
E T
E R
I N
G
O F
P M
C F
R
E
N G
I N
E E
R I
R M
A N
T O
W N
C
E N
T U
V
D
C F
R
E
N G
I N
E E
R I N
G
A
L E
N F
E
G
N F
E
G
X
N I S
P1.01
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
(E) BAS METERING PANEL
AutoCAD SHX Text
4" CW UP (E)
AutoCAD SHX Text
4" CW (E)
AutoCAD SHX Text
4" CW MAIN ENTERING (E)
AutoCAD SHX Text
FIRE WATER SYSTEM (E)
AutoCAD SHX Text U
AutoCAD SHX Text
US FLOWMETER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text
METER (X)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text J
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
(E) PANEL PB-A-4
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
%%UCORRIDOR
AutoCAD SHX Text
%%USTAIRS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NEW WORK PLAN NOTES
AutoCAD SHX Text
1. REFERENCE PLUMBING DETAILS AND SPECIFICATION REFERENCE PLUMBING DETAILS AND SPECIFICATION DIVISION 23 INSTRUMENTATION AND CONTROLS FOR INSTALLATION REQUIREMENTS. 2. INSTALL FLOW METERING DEVICE ACCORDING TO INSTALL FLOW METERING DEVICE ACCORDING TO MANUFACTURER RECOMMENDATION. 3. COMMUNICATION BETWEEN FLOW METER CONTROLLER COMMUNICATION BETWEEN FLOW METER CONTROLLER AND BAS SHALL BE VIA BACNET. 4. INSTALL FLOW METER DEVICE IN ACCESSIBLE LOCATION INSTALL FLOW METER DEVICE IN ACCESSIBLE LOCATION FOR MAINTENANCE. 5. NO INSULATED PIPE OR FIRE STOP DISTURBANCE NO INSULATED PIPE OR FIRE STOP DISTURBANCE AND/OR DEMOLITION SHALL BE PREFORMED PRIOR TO THE RECEIPT OF A COMPLETED ACM (ASBESTOS CONTAINING MATERIAL) SURVEY INDICATING WORK CAN CONTINUE. THE ACM SURVEY WILL BE PERFORMED BY THE PLANT DIVISION SAFETY COORDINATOR. 6. THE SHOP FOREMAN AND/OR THE PROJECT COTR THE SHOP FOREMAN AND/OR THE PROJECT COTR SHALL NOT AUTHORIZE WORK TO BEGIN ON PROJECTS INVOLVING INSULATED PIPE AND/OR FIRE STOP DEMOLITION PRIOR TO HAVING A COMPLETED ACM SURVEY. REFER TO PLANT DIVISION INSTRUCTION FOR PIPING PROJECTS.
AutoCAD SHX Text
PLUMBING NEW WORK PLAN NOTES
AutoCAD SHX Text PROVIDE TYPE Q CLAMP-ON FLOW TRANSDUCER ON UTLRASONIC FLOW METER. CALIBRATION IS TRACEABLE TO NIST AND A2LA/ISO 17025 ACCREDITED. PROVIDE ADM 7407 SINGLE CHANNEL FLOWMETER FLUXUS TYPE F704A. LOCATION OF ELECTRICAL PANEL IS SHOWN FOR REFERENCE ONLY. . ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES. PROVIDE TWO SEPARATE 3/4"C: ONE WITH (2) TWISTED SHIELDED PAIR SIZE 18 AWG MINIMUM AND CAT6 CABLE AND THE SECOND W/ #12, & #12 GND, THHN COPPER, TO BAS PANEL & TO CONNECT FLOWMETERS REMOVE EXISITING FLOWMETER AND PATCH PIPING AND INSULATION. REMOVE TRANSDUCER LEADS AND CONDUIT ON THE EXISTING METER BACK TO THE OLD METERING PANEL.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text
%%UTEL. CLO.
AutoCAD SHX Text
%%UELEC. CLO.
AutoCAD SHX Text
%%UB171
AutoCAD SHX Text
%%UB173
AutoCAD SHX Text
%%UCORRIDOR
AutoCAD SHX Text
%%USTAIRS
AutoCAD SHX Text
(E) ELEC. PANEL (PB-1-4)
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 222 FIRST FLOOR PART PLAN ELECTRIC ROOM B171 - NEW WORK
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
BUILDING 222 ATTIC PART PLAN - NEW WORK - ELECTRICAL
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
BUILDING 222 SERVICE ENTRY ROOM - NEW WORK
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SITE
AutoCAD SHX Text
SITE
AutoCAD SHX Text
NORTH
PLUMBING/ ELECTRICAL
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
P
L O
T
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
N I S
T
G A
I T
H E
R S
B U
R G
M
D
F I N
A L
S
U B
M I S
S I
D E
M A
T
A B
L E
W A
T E
R
M
E T
E R
I N
G
O F
P M
C F
R
E
N G
I N
E E
R I
R M
A N
T O
W N
C
E N
T U
V
D
C F
R
E
N G
I N
E E
R I N
G
A
L E
N F
E
G
N F
E
G
X
N I S
P5.01
AutoCAD SHX Text NOTE: 1) PROVIDE POWER TO FLOW METER. 2) COMMUNICATION BETWEEN FLOW METER CONTROLLER AND BAS SHALL BE VIA BACNET MS/TP . 3) WORKSTATION PROGRAMMING SHALL PROVIDE TREND ANALYSIS AND GRAPHICS WORKSTATION PROGRAMMING SHALL PROVIDE TREND ANALYSIS AND GRAPHICS 4) BAS SHALL MONITOR FLOW RATE AND TOTAL FLOW AS SENSED BY FLOW BAS SHALL MONITOR FLOW RATE AND TOTAL FLOW AS SENSED BY FLOW TRANSMITTER.
AutoCAD SHX Text
POWER 120 VAC, 20 AMP FROM EXISTING ELEC.PANEL (E)
AutoCAD SHX Text NOTE: 1) ALL IP ADDRESSES, MAC ADDRESSES, AND FIBER PORTS ASSIGNMENTS SHALL BE PROVIDED BY THE GOVERNMENT.
AutoCAD SHX Text
JUNCTION BOX (E)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5.01
AutoCAD SHX Text
BAS SYSTEM ARCHITECTURE RISER DIAGRAM
AutoCAD SHX Text
SCALE : NONE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5.01
AutoCAD SHX Text
FLOW METERING - BAS - SCHEMATIC
AutoCAD SHX Text
SCALE : NONE
AutoCAD SHX Text
FLOWRATE
AutoCAD SHX Text
AI
AutoCAD SHX Text
(E) DOMESTIC COLD WATER
AutoCAD SHX Text
BACNET
AutoCAD SHX Text F
AutoCAD SHX Text
(E) DOMESTIC COLD WATER
AutoCAD SHX Text
TOTAL FLOW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 5.01
AutoCAD SHX Text
ULTRASONIC FLOWMETER INFLOW / OUTFLOW SECTIONS
AutoCAD SHX Text
SCALE : NONE
AutoCAD SHX Text NOTES: 1) REFER TO P1.01 FOR PIPE SIZE. 2) D=PIPE DIAMETER. D=PIPE DIAMETER. 3) CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REINSTALLING INSULATION. CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REINSTALLING INSULATION. CONTRACTOR SHALL CONFIRM WITH COR THAT ASBESTOS INSULATION IS NOT PRESENT PRIOR TO REMOVAL.
AutoCAD SHX Text
10XD
AutoCAD SHX Text
5XD
AutoCAD SHX Text
(E) INSULATION
AutoCAD SHX Text
(E) BARE PIPE
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
(E) BARE PIPE
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
TRANSMITTER PANEL
AutoCAD SHX Text
FLOWMETER BAS PANEL (E)
AutoCAD SHX Text
NEW POWER AND DATA WIRING CONDUIT BY CONTRACTOR (TYP)
AutoCAD SHX Text
JUNCTION BOX(N) (TYP.2)
AutoCAD SHX Text
DOMESTIC WATER FLOWMETER
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text
TRANSMITTER (N)
AutoCAD SHX Text
120 V FROM BAS TO TRANSMITTER
AutoCAD SHX Text
120 V CIRCUIT FROM BAS PANEL
AutoCAD SHX Text
(TYP. FOR 2)
AutoCAD SHX Text
24V CIRCUIT FROM TRANSDUCER TO TRANSMITTER
AutoCAD SHX Text
24V FROM TRANSDUCER TO FLOWMETER
AutoCAD SHX Text
24V+CAT6 ETHERNET FROM BAS TO TRANSMITTER
AutoCAD SHX Text
24V+CAT6 ETHERNET FROM BAS
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SITE
AutoCAD SHX Text
SITE
AutoCAD SHX Text
NORTH
P/E - DETAILS AND CONTROL DIAGRAMS
| 222-688 M0.01-222.688 |
| Sheets and Views |
| 222-688 M0.01-222.688 |
| 222-690 M0.02-222.690 |
| Sheets and Views |
| 222-690 M0.02-222.690 |
| 222-690 M1.01-222.690 |
| Sheets and Views |
| 222-690 M1.01-222.690 |
| 222-690 M5.01-222.690 |
| Sheets and Views |
| 222-690 M5.01-222.690 |
File details come from the government source that posted it. Updated .