Statement of Work The contractor shall provide quantity one (1) Refrigerated Air Cooling Unit in accordance with the below specifications.

Cooling Unit Specifications:

Coolant Characteristics:

Coolant Composition Supply Rate Supply Temperature Supply Pressure, adjustable Filtration

Filtered air 26 lbs/min 60° ± 3°F 11” ± 2” water column, typical 100 microns

Environment, Operating:

Temperature Relative Humidity

Altitude

10° to 27°C (50° to 80°F) To 95% at 10°C to 50% at 27°C (with condensation) To 1,000 feet above MSL

Environment, Non-operating
-35° to +55°C (-31° to +131°F)

Power Requirements

115/230 VAC 3-phase 60 Hz 50A

Interlock Activators

Low air flow Air over temperature AC failure

Electrical Box Door Controls/Indicators
Circuit Breaker w/ Phase Lights

Clogged Filter Indicator Over Temperature Indicator Low Pressure Indicator Audible Alarm with Reset Running Time Meter Fuse, Control Circuit

Electrical Box, Inside
Compressor Switch
Front Panel Indicators
Supply Temperature Gauge

Supply Pressure Gauge Calibration Port With Valve

Condensing Unit Refrigerant Compressor Fan

R-22 3 hp, 3-phase 1/3 hp, 1-phase

Air Blower

Centrifugal, 7½ hp, 3480 RPM, 3-phase

Dimensions (approximate) Width Depth Height Weight Output duct

48” 48” 72” 1500 lbs 6”

Additional requirements: Unit must be on casters