UPDATEDQuestions_Responses.docx
DOCX document 18 KB Posted
- Attached to
- HEATED SALT BATH FURNACE MAITENANCE AND REPAIR
- Solicitation number
- N6852026Q1006
About this file
This is a Questions and Responses document providing clarifications for RFQ N6852026Q1006, a firm fixed price commercial service contract for repair and inspection of an Upton Internally Heated Salt Bath Furnace (Model U-DS/UDJ6A, Serial Number DS-2976) located at Fleet Readiness Center Southeast (FRCSE), Naval Air Station, Jacksonville, Florida. The furnace is used to heat treat various aircraft components. This is a new requirement with no incumbent contractor; the contract number will be assigned upon award.
Key technical details include tank dimensions of 209 inches length by 61 inches width by 90 inches depth, with a 30,000-pound salts weight capacity and an 85.37 cubic foot working zone volume. All work will be performed by a single contractor with sequencing developed prior to start of work. Inspection activities may span multiple days due to equipment setup requirements. The Government confirms that the inspection scope aligns with its expectations. The award will be made to the responsible offeror providing the Lowest Price Technically Acceptable quotation based on price reasonableness in accordance with FAR 13.106-3, with technical acceptability evaluated on an Acceptable/Unacceptable basis. A site visit was scheduled for March 16, 2026, at 9:00 AM EST at FRCSE, Jacksonville, Florida.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment - N6852026Q10060001.pdf | ||
| ATTACHMENT 01 SITE VISIT INFORMATION.pdf | ||
| Questions_Responses.docx | DOCX document | |
| CDRL.pdf | ||
| Solicitation - N6852026Q1006.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS
RESPONSES
| 1 |
| Is this a brand-new contract OR if there is (was) an incumbent performing these services? |
If brand new, could you please provide the current/previous contract number?
This is a new requirement and there is no previous contract number available to provide. The contract number will be provided upon award.
| 2 |
| Could you please provide the tank dimensions (length, width, depth, or approximate volume)? |
| Tank dimensions L-209” X W-61 ½” X D-90”, capacity (salts weight) – 30,000 lbs., working zone volume – 85.37 cu. Ft. |
| 3 |
| Will the NDT inspection occur after the tank is fully drained and prepared by another contractor, or is the NDT contractor expected to coordinate access with other trades performing the pump-out and maintenance work? |
If known, will there be a defined window or sequence for the inspection activities during the performance period?
Inspection Access and Work Sequencing:
All work should be done by one contractor, and sequencing will be developed prior to start of work.
| 4 |
| Could you please confirm whether this testing is expected to be performed in a single inspection shift or potentially over multiple days, depending on tank size and condition? |
| Potentially multiple days due to equipment setup |
| 5 |
| Please confirm whether this interpretation aligns with the Government’s expectations for the tank inspection tasking |
| Inspection Scope Confirmation; Yes |