N6833520R0154
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
AMENDMENT 0004
Amendment 0004 1-This amendment hereby extends the solicitation end date from 26 April 2021 to 12 May 2021.
2-The following are questions that were received by this Agency and our answers:
| 1 |
| For the Ethernet crosstalk and other performance measurements, the specification does not appear to specify the frequency range needed for these measurements. For example, CAT 6 requirements typically specify performance up to 250 MHz, while CAT 5 is only up to 100 MHz. |
The DBNT System Performance Spec is intentionally silent on the categories/frequency ranges for Ethernet. Offerors should describe what their systems’ capabilities are.
| 2 |
| The Ethernet crosstalk check is the only specification which requires a "graphical form" display. Is the requirement for the graphical display to chart crosstalk (dB) vs frequency? |
Yes, crosstalk should be displayed graphically in dB versus frequency. Other specification parameters may be displayed in graphical or tabular (alphanumeric) format or both.
| 3 |
| For both the 1553 and Ethernet requirement, the specification requires pairs of 6' test adapter cables. Can we assume there is no need for a RJ45 or BJ-79C-201 connector directly on the testers, and that the test connectors only need to be at the end of the 6ft adapter cables? |
No, that should not be assumed. The connectors for MS-1553 and Ethernet on the DBNT unit, itself, are specified in sections 3.1.1.1.2 and 3.1.2.2.6, respectively, and should be of the female gender. The cables should be male-to-male.
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 26-Apr-2021 04:30 PM to 12-May-2021 04:30 PM.