CoSC_ISP_Installation_Standards_v1_0.pdf
PDF 334 KB Posted
- Attached to
- Systems Furniture - Lakehurst Bldg 150 & 120
- Solicitation number
- N68335-16-T-0333
About this file
CoSC ISP Installation Standards
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Furniture_Evaluation_Plan_Contracts.doc | DOC document | |
| Air_Force_LKHR_Voice_ISP_Cabling_Spec_(v1)_2011a.pdf | ||
| NAVAIR_LKHR_ISP_Cabling_Spec_(v3_3)_2013.doc | DOC document | |
| SOW_Bldg_150_HRO_Furniture.docx | DOCX document | |
| SOW_Bldg_120_Contracts_Furniture.docx | DOCX document | |
| CDRL_-_2.5_Reconfiguration_v1.pdf | ||
| SOW_-_Diagram_B150-B_v1.docx | DOCX document | |
| B120-2W_Floor_Plan.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Refer to page i for the Intellectual Property statement.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Navy Marine Corps Intranet A superior Intranet and the service to back it up
CoSC Inside Cable Plant Installation Standards
Final
Version 1.0
May 16, 2011
NMCI.90755.01.F+0.E
CoSC Inside Cable Plant Installation Standards
Final, Version 1.0, May 16, 2011 i NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on this page.
GOVERNMENT PURPOSE RIGHTS
Contract No. N00039-10-D-0010
Contractor Name: HP
Contractor Address 13600 EDS Drive
Herndon, VA, 20171
The Government's rights to use, modify, reproduce, release, perform, display, or disclose this technical data/computer software are restricted by clause H-8 contained in the above identified contract. Any reproduction of this technical data/computer software or portions thereof marked with this legend must also reproduce the markings.
Final, Version 1.0, May 16, 2011 ii NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Change History
This document was created using the most recent version of the operations support template. The
NMCI Knowledge Management Systems (KMS) version of the master template is controlled. All other versions are uncontrolled.
Date
Published/
Revised
Version
No.
Author or Point of
Contact Section / Description of Change
06/20/05 0.01 UNK Existing version used under NMCI Contract.
04/29/11 0.02 Joel Dorr Reissuance under CoSC.
05/03/11 0.03 Jim Deasy – RTP Updated to current KMS format.
05/06/11 0.04 KMS Edited, formatted, and assigned document ID number.
05/06/11 0.05 Jim Deasy – RTP Minor editing for clarification.
05/16/11 1.0 KMS Finalized and converted to PDF.
NMCI operations support documents are identified on the title page as a draft or final, followed by the version number. Draft and final documents are defined and numbered, as follows:
Initial drafts are numbered version 0.01 (D+1). Subsequent draft editions are numbered version 0.02 (D+2), 0.03 (D+3), 0.04 (D+4) and so forth.
The first final edition is numbered version 1.0 (F+0). Subsequent final versions are numbered
1.1 (U+1), 1.2 (U+2), 2.0 (UA0), 3.0 (UB0), 4.0 (UC0) and so forth.
After KMS finalizes the first version 1.0 (F+0), the following applies:
The document cannot revert to a draft. All subsequent versions are finals.
In the Change History Log, point of contact (POC) entries are numbered X.X.X (for example, 1.0.1, 1.1.1, 1.2.1, and so forth).
The POC must request the latest version by sending an email to
DMCIncomingRequest@nmci-isf.com.
For a list of current abbreviations, acronyms, and terms, click the following link: NMCI Master
Abbreviations, Acronyms, and Terms. For additional information, see the latest version of NMCI
Naming Standards, D400.11939.01, available from the Definitive Solution Library (DSL).
For more information about NMCI documentation, send an email to
DMCIncomingRequest@nmci-isf.com.
mailto:DMCIncomingRequest@nmci-isf.com http://www.homeport.navy.mil/downloads/index.aspx?f=/about/downloads/master_glossary_of_acronyms.pdf http://www.homeport.navy.mil/downloads/index.aspx?f=/about/downloads/master_glossary_of_acronyms.pdf mailto:DMCIncomingRequest@nmci-isf.com
Final, Version 1.0, May 16, 2011 iii NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Document Properties
Owner: Network Services, Core Services Manager
Responsible Organization: Network Services - Network Delivery
Affected Organizations: Network Services, Field Services (for awareness of the standard)
Posted Location: Network Services QMS SharePoint
Final, Version 1.0, May 16, 2011 iv NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Contents
1. INTRODUCTION/GENERAL INFORMATION
1.1 Inside Plant Installation Test Results
1.2 Acceptance of Government-Installed ISP
1.3 Deviation From ISP Installation Standards
1.4 Protective Distribution Systems Installations
1.5 Red/Black Separation
1.6 ISP Installation Consistency
2. ISP CABLE DESIGN STANDARDS
2.1 ISP Horizontal Cat 5e Cabling Requirements
2.2 Installation Materials
2.3 Inside Plant Fiber Optic Cable
2.3.1 FTTD Standards
2.4 Copper and Fiber Panels
2.4.1 Patch Panels, Cat 5e
2.4.2 Wire Management Panels
2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)
3. STANDARD WIRING FOR NMCI SEATS
3.1 NMCI Seat Descriptions
3.2 Installation Descriptions
3.2.1 Standard Unclassified Seat/Printer (Two-Drop)
3.2.2 Optional Unclassified Seat (Four-Drop)
3.2.3 Standard Classified Seat
3.2.4 Standard Classified Printer
3.2.5 Standard Unclassified FTTD Connections
3.2.6 Classified FTTD Connection Option
3.3 Standard Configuration: Work Area
3.3.1 Flush Mount
3.3.2 Surface Mount
3.4 Standard Configuration: Data Closet (ISP)
3.5 Numbering and Naming Convention
Figures Figure 1: Standard Unclassified Seat/Printer (Two-Drop) Figure 2: Optional Unclassified Seat (Four-Drop)
Figure 3: Standard Classified Seat Figure 4: Standard Classified Printer Figure 5: Standard Unclassified FTTD Connection Figure 6: Classified FTTD Connection Option Figure 7: Numbering and Naming Convention
Final, Version 1.0, May 16, 2011 v NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
Tables Table 1: ISP Fiber Optic Cable Table 2: FTTD Standards Table 3: NMCI Seat Descriptions
Final, Version 1.0, May 16, 2011 1 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
1. INTRODUCTION/GENERAL INFORMATION
This document defines the standards to be used for inside cable plant installations for NMCI.
1.1 Inside Plant Installation Test Results
Inside plant (ISP) Installation Test Results will consist of a portable document file (PDF) file download from the testing equipment and will include: Unshielded Twisted Pair (UTP) permanent link tests in accordance with Electronic Industries Alliance / Telecommunications
Industries Association (EIA/TIA)-568-B.1, B.2, and manufacturer’s guidelines.
HP requires test results that show how the installed cable lines up with the T-568B standard (for example, Wire map, Frequency, Insertion Loss, NEXT, PSNEXT, Return Loss, Delay, Skew, Length, Identification of the Cable being tested, and so forth).
1.2 Acceptance of Government-Installed ISP
The government-installed ISP is accepted by HP after testing and labeling by HP according to
NMCI standards. The testing and labeling are the financial responsibility of the government.
Where necessary, termination (or retermination) into the NMCI cabinet is also the financial responsibility of the government.
1.3 Deviation From ISP Installation Standards
Any deviation from the standards outlined in this document must be approved in advance by the
Core Services Area Manager. At the time of the writing, this is the following:
Area East: David Van Hoose; Telephone: 571-437-0475; Email: david.vanhoose@hp.com
Area West: Matthew Galusha; Telephone: 619-817-3236; Email: matthew.galusha@hp.com
1.4 Protective Distribution Systems Installations
The standard security guidelines published by the government on classified Protective
Distribution Systems (PDSs) (US Navy/Marine Corps Information Assurance [IA] PUB 5239-
22) is followed.
1.5 Red/Black Separation
Classified and Unclassified ISP installations are performed according to National Security
Telecommunications and Information Systems Security Advisory Memoranda (NSTISSAM)
Final, Version 1.0, May 16, 2011 2 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
TEMPEST/2-95 (Recommendations B, E and H of Section 3 depending on the size of the facility) for Red\Black separation.
NOTE: As a general rule on NMCI, HP has separated unclass/class processing by 3 feet / 36 inches and parallel cabling by 6 inches (for example, the faceplates are separated by at least 3 feet / 36 inches and the horizontal cabling is separated by 6 inches).
1.6 ISP Installation Consistency
HP retains the same media type in a building for new installs. Buildings with existing
Fiber-to-the-Desktop (FTTD) ISP Installations receive new FTTD, if a government-furnished equipment (GFE) installation was Category 6 (Cat 6), HP will install Cat 6 to retain the same standard.
NOTE: The existing media type must equal or exceed Cat 5e requirements.
Final, Version 1.0, May 16, 2011 3 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
2. ISP CABLE DESIGN STANDARDS
This section discusses ISP cable design standards.
2.1 ISP Horizontal Cat 5e Cabling Requirements
Cat 5e, 4-pair, 100 Ω UTP, CMP, (Plenum-rated), cable
Cat 5e, 4-pair, 100 Ω UTP, CMR, (Riser-rated), cable. (Where permitted by code)
NOTE: It is not anticipated that individual cable drops will be required in support of the implementation of Voice over Internet Protocol (VoIP) within the NMCI network. But if these drops are required, any new cabling installed must be Cat 5e specification or better.
NOTE: Total maximum horizontal passive cable length (NMCI patch panel to drop) will not exceed 295 feet. If the ISP is being installed to a remote cabinet (for example, GOV cabinet) with an ISP tie between the remote cabinet and the NMCI cabinet, the distance between the cabinets must be taken into consideration of the 295 feet maximum.
Cable Sheath color-coding is specifically called out with the following colors:
Data #1: Blue
Data #2: Green
VoIP #1: White
VoIP #2: Grey
Classified #1: Red
Classified #2: Red
2.2 Installation Materials
IDC Termination: All Cat 5e cabling will be terminated in the Data
Cabinet/Telecommunications Room using Cat 5e, 24-port and/or 48-port, 110-type Insulation
Displacement Contact (IDC) to 8-position T568-B configured patch panels. (For smart configuration the four drops will be terminated in same patch panel.)
Standard configuration: Two data drops terminated on data patch panels.
Optional configuration (if required): Two data drops terminated on data patch panels, and two VoIP drops terminated using separate VoIP Cat 5e, 24-port and/or 48-port, 110-type IDC to 8 position, T568-B configured patch panels. However, on smaller installations the same patch panel may be used for both voice and data cabling.
Final, Version 1.0, May 16, 2011 4 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
Optional Voice Terminal Blocks: HP may specify 66 /110 Blocks (Cat 5e certified) as the final end point for the VoIP cabling in the data closet. Horizontal cabling from the work area will still be terminated on VoIP Cat 5e, 48 port, 110-type IDC to 8 position, patch panels.
Cat 5e, 4 pair, 100 Ω UTP, CMP or CMR rated, cable will be extended from new
VoIP patch panels to the wall fields 66/110 termination block for final connections.
All 4 pairs will be mirror image through the 66/110 termination blocks to the patch panels.
J Hooks: The default cable installation will use J-hooks. The installation will be adjusted to conform to existing installation practice (J-hooks, ladder rack, cable trays, in wall/surface mount) for a building where possible. Where no current cabling exists, Jhooks will be the default method. Public Works Commission (PWC) requirements will be supported if counter to J-hooks.
EMT: Facility requirements will dictate the Electrical Metallic Tubing (EMT) requirements needed to protect cabling. Conduit size will be determined by fill ratio and is sized by current requirements.
Pin Configuration: Work area outlets will use Cat 5e 8-position outlets supporting universal
T568A/B wiring will be installed. All outlets will be T568-B wiring configuration.
Color Coding: Color-coding will be provided through the use of colored icons that snap into the face of the jack.
Icons: Work area outlets and patch panel positions will use the following colored icons:
Data #1: Blue
Data #2: Green
VoIP #1: White
VoIP #2: Grey
Classified #1: Red
Classified #2: Red
Final, Version 1.0, May 16, 2011 5 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
2.3 Inside Plant Fiber Optic Cable
Table 1 shows the ISP fiber optic cable specifications.
Table 1: ISP Fiber Optic Cable
Type: Multimode (MM) fiber optic cable Single-mode (SM) Fiber Optic
Cable
Use: FTTD
UNCLASSIFIED, CLASSIFIED
Mission Critical seat
Closet to Closet
TIE cable (closet to closet)
UNCLASSIFIED, CLASSIFIED
Mission Critical seat
Closet to Closet
Sheath Color: Orange Yellow
Strand Count: Six strand 12 strand
Construction: dielectric strength member dielectric strength member
Buffering: Tight buffered Tight buffered
Listing/Rating: CMR or CMP CMR or CMP
Core/Cladding: 62.5/125 μm 8.3 - 9/125 μm/SM
Connector: SC (FTTD)
ST, LC or SC (CLASSIFIED)
SC (TIE cable)
ST, LC or SC (CLASSIFIED)
New installations are to utilize J-hooks as the baseline. Alternative means may be used if required by building codes/PWC practices.
2.3.1 FTTD Standards
Data closet fiber patch panels and work area faceplates will use the color coding in Table 2 based on pulling a six-strand fiber optic cable.
Table 2: FTTD Standards
Work Area Data Room
D1/S1-A XMT: Blue D1/S1-A RCV: Blue
D1/S1-B RCV: Orange D1/S1-B XMT: Orange
D2/S2-A XMT: Green D2/S2-A RCV: Green
D2/S2-B RCV: Brown D2/S2-B XMT: Brown
Final, Version 1.0, May 16, 2011 6 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
The Slate and White strands are not terminated at both ends and they are not to be cut short.
Unless specified otherwise:
UNCLASSIFIED fiber is terminated in duplex SC connectors
CLASSIFIED fiber is terminated in dual ST, LC or SC connectors
Multimode cable will have a maximum run length of 600 feet from patch panel to the drop on the wall.
2.4 Copper and Fiber Panels
This section discusses the copper and fiber panels.
2.4.1 Patch Panels, Cat 5e
Under the Continuity of Services Contract (CoSC), only 24- or 48-Port Patch Panel will be used as follows:
Must be Cat 5e compliant
Rear cable management
Icon labels/holders available in colors to match the cables
1 rack unit (RU) height - 24 port
2 RU height – 48 port
110-type IDC rear cable termination or equipment
Universal T568A/B wiring
All patch panels shall be terminated to a T568-B wiring configuration
NOTE: 96-port patch panels are not allowed as cable management is insufficient to support
Moves, Adds, and Changes (MACs).
2.4.2 Wire Management Panels
A description of the wire management panels is as follows:
Single-sided or Double-sided
Front cable management with cover
Optional Rear cable management
Optional Pass-through holes for front to back routing
Cable retention design
Final, Version 1.0, May 16, 2011 7 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
1 RU height: 1.75”
2 RU height: 3.50”
NOTE: All patch panels will be matched with a horizontal wire management panel above and below the patch panel.
2.4.3 Fiber Optic Closet Connector Housings (Fiber Panels)
A description of fiber optic closet connection housings (fiber panels) is as follows:
12, 24, 48, 72 and 144 Port Panels
1, 2 and 4 RU heights: 1 RU = 1.75 inches
SC duplex connector panels supporting 12 strands per panel for UNCLASSIFIED
ST, LC or SC dual connector panels supporting 12 strands per panel for CLASSIFIED installation of connector type is based on what is currently in place)
Splice trays supported (Fiber Distribution Centers) if required
Rack-mount and wall-mount versions
Final, Version 1.0, May 16, 2011 8 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3. STANDARD WIRING FOR NMCI SEATS
This section discusses the standard wiring for NMCI seats.
3.1 NMCI Seat Descriptions
Table 3 shows the NMCI seat descriptions.
Table 3: NMCI Seat Descriptions
Seat Type
Number of
Cables- Cat
5e (Drops)
Number of Wall
Plates
Cable Outlet
Designations
Conduit
Required
Figure
Number
Jack, Connector
Type
Unclassified Seat
(including mission critical seats)
2 1 D1, D2 - 1 T568-B
Unclassified
Option
4 1 D1, D2, V1, V2
- 2 T568-B
Classified Seat
(including mission critical seats)
2 1 S1, S2 - 3 T568-B
Classified
Printer
2 1 S1, S2 3/4” EMT 4 T568-B
Unclassified
Printer
2 1 D1, D2 - 4 (w/o
EMT)
T568-B
UNCLASSIFIED FTTD consisting of:
Unclassified 2 MM 2-
Strand Pairs
(4 strands)
1 D1, D2 - 5 Duplex SC
CLASSIFIED Fiber-To-Desk (FTTD) consisting of:
Classified 2 MM 2-
Strand Pairs
(4 strands)
1 S1, S2 - 6 Dual ST, LC or SC
Final, Version 1.0, May 16, 2011 9 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.2 Installation Descriptions
This section describes the installation.
3.2.1 Standard Unclassified Seat/Printer (Two-Drop)
Unclassified Seat/Printer Installation –Two Drops: Two Cat 5e cables to a single wall plate.
Terminate each cable on a Cat 5e, 8-position, modular insert. This standard also applies to unclassified mission critical seats.
Cable 1 will be designated D1 (Data 1)
Cable 2 will be designated D2 (Data 2)
NOTE: Unless otherwise specified by HP, the vendor is to install unclassified ISP to this standard for Copper installations.
Figure 1 shows the standard unclassified seat/print (two-drop).
120-1-3B
00700-0111-014 Unclassified Data Closet
Category 5e
Patch Panel
D1 D2
D2 - Green
D1 - Blue
Category 5e
Wall Plate
Unclassified
Green IconBlue Icon
Figure 1: Standard Unclassified Seat/Printer (Two-Drop)
Final, Version 1.0, May 16, 2011 10 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.2.2 Optional Unclassified Seat (Four-Drop)
Optional Installation – Unclassified - Four Drops: Four Cat 5e cables to a single wall plate.
Terminate each cable on a Cat 5e, 8-position, modular insert.
Cable 1 will be designated D1 (Data 1), Cable 2 will be designated D2 (Data 2), Cable 3 (V1) and Cable 4 (V2) will be designated for VoIP
NOTE: This option is only implemented at sites with VoIP capability and the government customer has ordered the applicable CLIN items. HP directs the vendor to install to this option;
otherwise, the two-drop option is to be used as the standard.
Figure 2 shows the optional unclassified seat (four-drop).
V1 V2
120-1-3B
00700-0111-014 Unclassified Data Closet
Category 5e
Patch Panels
D1 D2
V2 - Gray
D1 - Blue
Category 5e
D2 - Green
V1 - White
NOTE: D1, D2 are on separate patch panel from V1, V2
Wall Plate
Unclassified
Green IconBlue Icon
White Icon Grey Icon
Figure 2: Optional Unclassified Seat (Four-Drop)
Final, Version 1.0, May 16, 2011 11 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.2.3 Standard Classified Seat
The Classified Seat: Two Cat 5e cables to a single wall plate. Terminate each cable on a Cat 5e, 8-position, modular insert. This cable run must conform to all applicable Classified/PDS guidelines. Verify site requirements for Secret Internet Protocol Router Network (SIPRNET) according to Base Security Requirements. This standard also applies to classified mission critical seats.
Cable 1 will be designated S1 (Secure Data 1)
Cable 2 will be designated S2 (Secure Data 2)
Figure 3 shows the standard classified seat.
120-1-3B
00700-0111-014 Classified Data Closet
Category 5e
Patch Panel
S1 S2
S2 - Red
S1 - Red
Wall Plate
Classified
Red Icon Red Icon
Figure 3: Standard Classified Seat
Final, Version 1.0, May 16, 2011 12 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.2.4 Standard Classified Printer
Classified Printer Installation: Two Cat 5e cables to a single wall plate. Terminate each cable on a Cat 5e, 8-position, modular insert. This cable run must conform to all applicable
Classified/PDS guidelines. Verify site requirements for SIPRNET according to Base Security
Requirements.
Cable 1 will be designated S1 (Secure Data 1)
Cable 2 will be designated S2 (Secure Data 2).
Figure 4 shows the standard classified printer.
120-1-3B
00700-0111-014 Classified Data Closet
Category 5e
Patch Panel
S1 S2
S2 - Red
S1 - Red
Category 5e in Conduit
Wall Plate
Classified
Figure 4: Standard Classified Printer
Final, Version 1.0, May 16, 2011 13 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.2.5 Standard Unclassified FTTD Connections
Four strands terminated out of a six-strand SM or MM fiber optic cable; pulled to a wall plate equipped with two duplex SC connectors.
NOTE: Multimode cable will have a maximum run length of 600 feet from patch panel to the drop on the wall
Figure 5 shows the standard unclassified FTTD connection.
D2A D2B
120-1-3B
00700-0111-014 Unclassified Data Closet
Fiber Optic
Patch Panel
D1A D1B
D2B - Brown
D1A - Blue
6 Strands of Multimode
62.5 Micron Fiber
D1B - Orange
D2A - Green
Wall Plate
Unclassified
2 Strands Coiled and
Spared out in Work Box
(White and Slate) Duplex SC Connectors
Figure 5: Standard Unclassified FTTD Connection
3.2.6 Classified FTTD Connection Option
Four strands terminated out of a six-strand SM or MM fiber optic cable pulled to single wall plate equipped with two dual ST connectors for CLASSIFIED/SIPRNET access. This cable run must conform to all applicable Classified/PDS guidelines. Verify site requirements for SIPRNET according to Base Security Requirements.
Final, Version 1.0, May 16, 2011 14 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
NOTE: Multimode cable will have a maximum run length of 600 feet from patch panel to the drop on the wall.
Figure 6 shows the classified FTTD connection option.
S2A S2B
120-1-3B
00700-0111-014 Classified Data Closet
Fiber Optic
Patch Panel
S1A S1B
S2B - Brown
S1A - Blue
6 Strands of Multimode
62.5 Micron Fiber
S1B - Orange
S2A - Green
Wall Plate
Classified
2 Strands Coiled and
Spared out in Work Box
(White and Slate) Dual ST, Duplex LC or
Duplex SC Connectors
Figure 6: Classified FTTD Connection Option
Final, Version 1.0, May 16, 2011 15 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.3 Standard Configuration: Work Area
This section discusses the standard configuration work area.
3.3.1 Flush Mount
Placement to work area: via J-Hook
Cable:
Category 5e
Plenum-listed
Four-pair
UTP
Mounting: In-wall box eliminator (for example, Caddy multiprotocol label switching
[MPLS])
Faceplate: single-gang four-port
Jacks: dual eight-position Cat 5e jacks and blank inserts
Color: light ivory with color coded icon for jacks
3.3.2 Surface Mount
This section explains the surface mount:
Placement to work area: via J-Hook and 10 feet of surface mount raceway
Cable:
Cat 5e
Plenum-listed
Four-pair
UTP
Maximum cable length: 250 feet
Mounting: single-gang surface mount box
Faceplate: single-gang four-port, Jacks: dual eight-position Cat 5e jacks and blank inserts
Color: light Ivory with color coded icon for jacks
Final, Version 1.0, May 16, 2011 16 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
3.4 Standard Configuration: Data Closet (ISP)
This section discusses the standard configuration data closet (ISP):
Patch Panel: Cat5e, 8-position, 24- or 48-port
Fiber Panel: Fiber Optic Termination Units
Housing: Open bay relay rack or equipment cabinet (Unclassified and Classified)
Cable management: horizontal and vertical management panels
Cable Support: Stovepipe, Ladder or Cable Tray providing support from rack to wall
Other:
Telecommunications Grounding Busbar
Sleeves and/or Slots
Fire-stop system
3.5 Numbering and Naming Convention
Figure 7 shows the numbering and naming convention.
V1 V2
120-1-3B
00700-0111-014
D1 D2
Cable ID
Building# - Room# - Drop/Seat#
Closet# - Rack# - Patch Panel#
Green IconBlue Icon
White Icon Grey Icon
120-1-3B
00700-0111-014
S1 S2
Wall Plate
Classified
Building# - Room# - Drop/Seat#
Wall Plate
Unclassified
Closet# - Rack# - Patch Panel#
Figure 7: Numbering and Naming Convention
Un-numbered cubical: When a cubical area is found unnumbered, it shall be numbered clockwise from North. The assigned numbers will be noted on the red lined floor plan.
Final, Version 1.0, May 16, 2011 17 NMCI.90755.01.F+0.E
Use or disclosure of data in this document is subject to the restrictions on page i.
© Copyright 2011 Hewlett-Packard Development Company, L.P.
If wiring closet room number is not available, label wiring closets, M01 for main 01, S01 for subcloset 01, and clockwise from the North.
If room numbers are unavailable, start numbering rooms North to South, West to East.
Drop numbers are in sequence by wiring closet.
Patch panels are identified by a number followed by F for front and B for back as necessary.
Numbers next to jacks are always D1, D2, S1, S2, V1 and V2, as they are part of the cable ID convention and not a patch panel number. D is for Data and V for VoIP.
NOTE: This CoSC wall plate naming scheme described herein supersedes all existing labeling schemes in place. This information is retained in a central database and must be followed exactly. Include all dashes and pad the appropriate numbers with zeros as needed.
WARNING: Do not deviate from the defined scheme.
File details come from the government source that posted it. Updated .