This is a Statement of Work (SOW) for auxiliary machinery repairs aboard the USS Lewis B Puller (ESB 3), specifically addressing ultrasonic thickness testing and temporary repair of ballast suction header piping under CASREP 26-036.
The contractor shall perform 150 ultrasonic thickness (UT) readings on a 36-inch diameter header and 24-inch diameter spool piece in the ballast water pump room (Location 5-57-0) using a standard 6-inch grid pattern on accessible areas. The piping is carbon steel (ASTM A53) with standard wall thickness of 0.375 inches (9.5mm). UT technicians must be either ABS External Specialists or qualified to ASME Code and approved by MSCREP. The UT equipment must read through paint films with accuracy within 0.005 inches, detect laminations and metal defects, and perform continuous scanning to determine deteriorated area peripheries. If any area shows 75% or greater diminution, the surrounding area shall be checked on a three-inch grid until diminution reaches 50% or less. The contractor shall submit a detailed "as found" condition report with UT reading locations, original and existing thicknesses, and percentage of wastage.
The temporary repair method depends on UT results and will be either a fiberglass composite wrap (approximately 8mm thick) or a steel plate doubler (0.375 inches thick, 24 inches long, 18 inches wide, with matched curvature). All welding must be performed by ABS-certified welders with current certifications and documentation per American Welding Society D1.1. The contractor shall provide and maintain daily gas-free certificates signed by an NFPA-certified Marine Chemist (or equivalent OCONUS certified professional) prior to confined space entry and hot work. Dye penetrant testing is required on root and final welds. ABS must witness and approve all pipe fit-up and welding in the pump room. A suggested source for fiberglass wrap repair is Rodator Composites. All new and disturbed surfaces shall be painted to match surrounding surfaces, and ships force shall perform an operational pressure test with no leakage allowed. Paint will be government-furnished by the crew.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - N6817127QN014.pdf | ||
| J-1 Contractor Price Breakdown.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USS LEWIS B PULLER
( ESB 3 )
AUXILIARY MACHINERY
ITEM NO. 0501 CATEGORY "A" 2026-11-27
Ballast Suction Header Piping Ultrasonic testing & Temporary Repair (CASREP 26-036)
A. Leofsky
0501 - 1
1.0 ABSTRACT:
1.1. This item is to record ultrasonic thickness (UT)
readings of Ballast Piping and install a temporary repair. The repair method depends upon the UT results
- it will be either a steel plate doubler or a fiberglass wrap.
2.0 REFERENCES/ENCLOSURES:
2.1 References:
2.1.1 ABS Rules for Building and Classing Steel
Vessels, Part 7
2.1.2 Drawing No. 8886027; Ballast Water System
Diagram
2.2 Enclosures:
2.2.1 Ocean Ships Drawing 2041-S10-1-1 USS MIGUEL
KEITH
2.2.2 LBP Ballast Pipe Leaking photos
2.2.3 Belzona Proposal BE-25.600 from Rodator
Composites dated 20 Nov 2026
3.0 ITEM LOCATION/DESCRIPTION:
3.1. Location: 5-57-0 Ballast Water Pump Room
3.2. Description: The piping wall thickness is STD – 0.375
inch or 9.5mm
3.3. Material: Carbon steel, ASTM A53
3.4. Quantity of UT readings: 150 Readings, Standard 6” grid
of accessible area only.
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES:
4.1. Paint will be provided by the crew.
5.0 NOTES:
5.1. The Ballast Suction Piping consists of a 36 inch
diameter Header attached to 24 inch diameter spool
AUXILIARY MACHINERY
ITEM NO. 0501 CATEGORY "A" 2026-11-27
Ballast Suction Header Piping Ultrasonic testing &
0501 - 2 piece which was leaking near the bottom and has been temporary repaired with shoring.
5.2. The water has been drained and Valve BW-V-21 has been
closed to provide isolation from the sea.
5.3. MSC plans to have divers install a cofferdam to provide
2-valve protection/isolation from the sea.
5.4. The UT equipment shall have following capabilities:
5.4.1. Reading through the paint films.
5.4.2. Metal readings shall be accurate within 0.005 of
an inch
5.4.3. Shall be capable of detecting and defining
laminations and/or other metal defects.
5.4.4. Shall be capable of continuous scanning to
determine the periphery of deteriorated areas below rejected metal thickness.
6.0 QUALITY ASSURANCE REQUIREMENTS:
6.1. The NDT-UT technicians are to be either ABS External
Specialist or qualified to ASME Code. Qualifications are to be reviewed and approved by MSCREP.
6.2. The Fiberglass wrap piping repair procedure must be
approved by ABS and installed by qualified technician.
6.3. The instruments used are to be calibrated on site with
certified blocks acceptable to the MSCREP.
6.4. All welding requirements shall be accomplished by ABS
certified welders. All welders shall be certified to perform the type of welding required and documentation of such shall be current. Fire watches shall be posted by the Contractor during hot work.
7.0 STATEMENT OF WORK REQUIRED:
7.1. The Ultrasonic (UT) technicians are to be either ABS
External Specialist or qualified to ASME Code.
AUXILIARY MACHINERY
ITEM NO. 0501 CATEGORY "A" 2026-11-27
Ballast Suction Header Piping Ultrasonic testing &
0501 - 3
Qualifications are to be reviewed and approved by
MSCREP.
7.2. The Fiberglass wrap piping repair procedure must be
approved by ABS and installed by qualified technician.
7.3. Enclosure 2.2.1 is provided for guidance and was
prepared for a similar event in 2025 on sister vessel
USS MIGUEL KEITH (ESB 5).
7.4. Enclosure 2.2.2 shows the leak site and shoring that
was installed on LEWIS B PULLER.
7.5. Accomplish 150 ultrasonic thickness readings using
qualified technicians. Take readings in the following locations and quantities as a minimum:
7.5.1. Perform ultrasonic thickness (UT) gauging on the
36 inch Header and 24 inch spool piece within a 4 foot radius of the leak
a. Survey is to determine scope of Repair work.
b. If an area under survey is found to have Diminution of 75% or more than the immediate area around the spot shall be checked on a three-inch grid until diminution is 50% or less.
7.5.2. Location and Quantity of readings for a given
location will be directed by MSCREP.
7.6. Submit an "as found" condition report of the ultrasonic
readings taken. This report is to contain detailed sketches of UT reading locations, the original thickness of plating or scantling, the existing thickness as gauged, and the percentage of wastage.
7.7. Depending upon the UT readings determine whether the
temporary repair will be either Fiberglass wrap or Steel plate doubler.
7.8. Outside of the United States, a Marine Chemist or
Industrial Hygienist, certified in the country or
AUXILIARY MACHINERY
ITEM NO. 0501 CATEGORY "A" 2026-11-27
Ballast Suction Header Piping Ultrasonic testing &
0501 - 4 locale where the work is to be accomplished, shall be utilized. Certified Marine Chemist shall have experience equivalent or adjacent to a national fire protection association (NFPA) Certified Marine Chemist to certify spaces gas free safe for personnel entry and safe for hot work (46 CFR 115.710 (a)).
7.9. Provide Marine Chemist to test and certify the Pump
Room and pipe to be “Safe for Hot Work”.
7.10. Furnish the OMT REP with two copies of the gas free
certificates signed by a NFPA certified Marine Chemist (or equivalent OCONUS Marine Chemist or Industrial Hygienist) prior to start of any confined space entry and/or hot work. Furnish a new gas free certificate, signed by a NFPA certified Marine Chemist (or equivalent OCONUS Marine Chemist or Industrial Hygienist), daily thereafter for the duration of the particular work necessitating gas freeing of spaces safe for men and hot work. One copy of said certificate is also to the posted near the gangway(s).
7.11. Gas free certificates shall be maintained on a daily
basis. This may be accomplished by a Contractor Provided competent person, provided same competent person is acceptable to all regulatory agency (e.g.
USCG, ABS) inspection personnel during inspections.
Should regulatory agency inspectors require NFPA certified Marine Chemist (or equivalent OCONUS Marine Chemist or Industrial Hygienist) certificates, the additional costs of contracting a Marine Chemist shall be borne by the contractor.
7.12. Contractor Provided competent persons shall be trained
by a NFPA certified Marine Chemist (or equivalent OCONUS Marine Chemist or Industrial Hygienist), and credentials demonstrating this training shall be provided to the OMT REP prior to any confined space entries.
7.13. Provide and install a steel doubler plate templated to
the thinned area – for estimating purposes assume the same material and 0.375 inch thickness as the original
AUXILIARY MACHINERY
ITEM NO. 0501 CATEGORY "A" 2026-11-27
Ballast Suction Header Piping Ultrasonic testing &
0501 - 5 pipe and length of 24 inches and width of 18 inches.
The curvature will need to matched accurately.
7.14. Prior to start of work item, KTR shall submit current
ABS/IACS member welder certifications and a listing of welder(s). Welder Certifications shall provide justification for the currency of the specified Weld Procedures in accordance with American Welding Society D1.1 paragraph 4.2.3, where welder continuity and currency logs shall be submitted. Contractor to ensure that any repair is to be carried out by ABS/IACS qualified welder.
7.15. Pipe fit up and welding is required to be accomplished
in the Pump Room with ABS to witness and approve.
7.16. Perform Dye Penetrant test on root and final welds.
7.17. Ships force in the presence of the contractor shall
perform an operational test of the repaired piping using system pressure provided by the ballast pumps to the satisfaction of MSCREP and the Chief Engineer. No leakage is allowed.
7.18. Paint all new and disturbed surfaces to match
surrounding surfaces.
7.19. Install fiberglass composite laminate wrap
approximately 8mm thick in vicinity of the leak to reinforce any piping with excessive thinning which includes bonding of metal plate – similar to Enclosure 2.2.3.
8.0 GENERAL REQUIREMENTS: Suggested source for Fiberglass wrap piping repair: