Text version

1301019380 W2021-237-03 B1176

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Provide Questions and Answ ers #1-6.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 07-Sep-2022

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N6660422Q0611

X 9B. DATED (SEE ITEM 11)

24-Aug-2022

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

07-Sep-2022

CODE

NAVAL UNDERSEA WARFARE CENTER

JOSEPH SCARPA, CODE 0222, 401-832-1499,

CONTRACTS DEPARTMENT

1176 HOWELL STREET, BLDG. 1258

NEWPORT RI 02841-1708

N66604 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

N6660422Q0611

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

QUESTIONS AND ANSWERS

Question #1: Please clarify Navy end-state for the existing 12’ high arborvitae trees that need to be cut and trimmed as required to install steel supports and Sea Tube piping (Drawing M-1).

Answer #1: Contractor shall determine which trees—and ways and means—to cut, trim, or remove in order to complete project.

Question #2: Please clarify drawing M-1 which indicates “Penetration thru insulated metal panel typical at 6 locations. Patch opening in panel based on manufacturer recommendations and detail on M-2.”

Answer #2. For information only, attached is an excerpt from Centria installation manual.

Question #3. While period of performance is 120 days, does the Government have an anticipated award date?

Answer #3. Government intends to award this project no later than 30 Sep 2022. Regardless of when awarded in September 2022, project delivery date will be Friday 3 Feb 2023.

Question #4. Welder qualifications referenced in Section J-2 Specification are AWS certifications. Will Government allow MIL-STD 248 welder qualifications for personnel who have S1, S2, S11 metal quals, in place of AWS D1.1? This is a higher NAVSEA qualification that covers the grade of steel referenced drawings.

Will Government also accept WPS for above qualification?

Answer #4. Government will accept MIL-STD 248 and WPS qualifications as indicated in Question #4.

Question #5. Inspection Criteria referenced in Section J-2 Specification is QC1. Drawing CLB M 02 01 01 references MIL-STD 2035. Please clarify which inspection criteria shall be used. Or is 2035 on the aluminum, and QC1 on the steel?

Answer #5. Informational drawing CLB M 02 01 01 illustrates a component of the aluminum Seatube assembly manufactured and inspected IAW MIL-STD 2035 by others, and furnished by Government to Contractor for installation. Specification (Attachment J-2) requires that steel welding inspectors be certified to meet the requirements of AWS QC1.

Question #6. Are the flanges already welded onto the 6061 aluminum Sea tube? We note an aluminum welder qual D1.2, and weld call outs on drawings, but it is not clear if there is actually any aluminum welding or if that is a factory supplied unit, and if the all the pipe sections come with flanges welded on (to include the boot).

Answer #6. Flanges already welded onto the Seatube sections. This contract requires no welding on the Seatube.

End of Questions and Answers