NAVAL UNDERSEA WARFARE CENTER
NEWPORT, RI FACILITIES BRANCH
WORK REQ. NO.
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
K . B
O U
LD
S
5/
/1
TI
TL
E S
H E
E T
B U
IL
D
IN
G
R
O O
M
19-021A
K . B
O U
LD
S
R . N
E
LS
O N
T-1
A D
D E
D C
O O
LI
N
G
5/
/1
5/
/1
AutoCAD SHX Text
BUILDING 1351 ROOM 115 ADDED COOLING
AutoCAD SHX Text
LIST OF DRAWINGS:
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
ID
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text 19-021A 1 OF 9 T-1 TITLE SHEET 1 OF 9 T-1 TITLE SHEET T-1 TITLE SHEET TITLE SHEET 19-021A 2 OF 9 A-1 PARTIAL FLOOR PLAN - ARCHITECTURAL 2 OF 9 A-1 PARTIAL FLOOR PLAN - ARCHITECTURAL A-1 PARTIAL FLOOR PLAN - ARCHITECTURAL PARTIAL FLOOR PLAN - ARCHITECTURAL 19-021A 3 OF 9 M-1 PARTIAL FLOOR PLAN - HVAC DEMOLITION 3 OF 9 M-1 PARTIAL FLOOR PLAN - HVAC DEMOLITION M-1 PARTIAL FLOOR PLAN - HVAC DEMOLITION PARTIAL FLOOR PLAN - HVAC DEMOLITION 19-021A 4 OF 9 M-2 PARTIAL FLOOR PLAN - HVAC NEW WORK 4 OF 9 M-2 PARTIAL FLOOR PLAN - HVAC NEW WORK M-2 PARTIAL FLOOR PLAN - HVAC NEW WORK PARTIAL FLOOR PLAN - HVAC NEW WORK 19-021A 5 OF 9 M-3 LEGEND AND GENERAL NOTES - HVAC 5 OF 9 M-3 LEGEND AND GENERAL NOTES - HVAC M-3 LEGEND AND GENERAL NOTES - HVAC LEGEND AND GENERAL NOTES - HVAC 19-021A 6 OF 9 M-4 SCHEDULE AND DETAIL SHEET - HVAC 6 OF 9 M-4 SCHEDULE AND DETAIL SHEET - HVAC M-4 SCHEDULE AND DETAIL SHEET - HVAC SCHEDULE AND DETAIL SHEET - HVAC 19-021A 7 OF 9 E-1 PARTIAL FLOOR PLAN - ELECTRICAL DEMOLITION 7 OF 9 E-1 PARTIAL FLOOR PLAN - ELECTRICAL DEMOLITION E-1 PARTIAL FLOOR PLAN - ELECTRICAL DEMOLITION PARTIAL FLOOR PLAN - ELECTRICAL DEMOLITION 19-021A 8 OF 9 E-2 PARTIAL FLOOR PLAN - ELECTRICAL NEW WORK 8 OF 9 E-2 PARTIAL FLOOR PLAN - ELECTRICAL NEW WORK E-2 PARTIAL FLOOR PLAN - ELECTRICAL NEW WORK PARTIAL FLOOR PLAN - ELECTRICAL NEW WORK 19-021A 9 OF 9 E-3 LEGEND, NOTES AND SCHEDULE - ELECTRICAL 9 OF 9 E-3 LEGEND, NOTES AND SCHEDULE - ELECTRICAL E-3 LEGEND, NOTES AND SCHEDULE - ELECTRICAL LEGEND, NOTES AND SCHEDULE - ELECTRICAL
AutoCAD SHX Text
GATE 23
AutoCAD SHX Text
BADGING OFFICE BLDG. #80
AutoCAD SHX Text
TO ROUTE 114
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NAVSTA GATE 17
AutoCAD SHX Text
AutoCAD SHX Text 75A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 109A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 102T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ATF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GATE 25
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W2018-362-01
AutoCAD SHX Text
FACILITIES BLDG. # 679
AutoCAD SHX Text
LOCATION MAP
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG. #1351
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
BUILDING 1351 KEY PLAN
AutoCAD SHX Text
ROOM 115 AREA OF WORK
SPEC. NO.
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
P A
R
TI
A L
FL
O
O R
P
LA
N
A R
C H
IT
E
C
TU
R A
L
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
A-1
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
PARTIAL FLOOR PLAN - ARCHITECTURAL DEMOLITION
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text
1. EXISTING GWB CEILING IN ROOM 115 SHALL BE REMOVED FOR A EXISTING GWB CEILING IN ROOM 115 SHALL BE REMOVED FOR A COMPLETE NEW ACT INSTALLATION, ALL DEMOLITION MAY NOT BE SHOWN FOR CLARITY, FIELD VERIFY ALL ITEMS REQUIRED TO BE REMOVED. 2. AT AREAS WHERE ABOVE CEILING WORK IS TO TAKE PLACE, THE AT AREAS WHERE ABOVE CEILING WORK IS TO TAKE PLACE, THE CEILING TILES AND GRID SHALL BE REMOVED AND REINSTALLED ONCE THE NEW WORK IS COMPLETE. REPLACE DAMAGED GRID AND TILE
AutoCAD SHX Text
%%UDEMOLITION NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
PARTIAL FLOOR PLAN - ARCHITECTURAL NEW WORK
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
NEW LED LIGHT FIXTURE
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text 24"x24" LAY-IN CEILING SUPPLY DIFFUSER
AutoCAD SHX Text 24"x24" LAY-IN CEILING RETURN/EXHAUST REGISTER
AutoCAD SHX Text
HVAC CEILING MOUNTED UNIT
AutoCAD SHX Text
NEW PENDANT SPRINKLER HEAD CENTER OF TILE
AutoCAD SHX Text
RELOCATED DIFFUSER
AutoCAD SHX Text
SEE MECH. PLAN
AutoCAD SHX Text
NEW DIFFUSER SEE
AutoCAD SHX Text
MECH PLAN(TYP. FOR 10)
AutoCAD SHX Text
NEW LED LIGHT FIXTURE
AutoCAD SHX Text
SEE ELECTRICAL PLANS
AutoCAD SHX Text
NEW 9'-6" CEILING HEIGHT
AutoCAD SHX Text
REMOVE CEILING AND
AutoCAD SHX Text
GRID AS REQUIRED
AutoCAD SHX Text
TO INSTALL DUCTWORK
AutoCAD SHX Text
RELOCATED SPRINKLER HEAD, (TYP. FOR 3)
AutoCAD SHX Text
RELOCATED SPRINKLER HEAD
AutoCAD SHX Text
RELOCATE SP HEAD (TYP. FOR 3) SEE PLAN BELOW
AutoCAD SHX Text
SURFACE MOUNTED LIGHT FIXTURES REMOVED(TYP. FOR 4) SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
DUCTLESS COOLING UNITS REMOVED(TYP. FOR 3) SEE MECH. PLANS
AutoCAD SHX Text
ENTIRE GWB CEILING TO BE
AutoCAD SHX Text
REMOVED AS WELL AS ALL
AutoCAD SHX Text
SUPPORTING STUDS ABOVE
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
RELOCATE SP HEAD SEE PLAN BELOW
AutoCAD SHX Text
REINSTALLED
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
REMOVED AND REINSTALLED
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text AREA AROUND ENTIRE ROOM WHERE GWB CEILING MEETS WALL SHALL BE SANDED, PATCHED AND PAINTED TO ACCEPT NEW ACT SUPPORT TRACK
AutoCAD SHX Text PROVIDE COMPLETE 2'x2'
AutoCAD SHX Text
SUSPENDED CEILING SYSTEM
AutoCAD SHX Text
5/16" EXPOSED GRID INTERMEDIATE
AutoCAD SHX Text
DUTY SUSPENSION SYSTEM W/ 5/8"
AutoCAD SHX Text
MEDIUM TEXTURE MINERAL FIBER
AutoCAD SHX Text
(SQUARE CUT FLAT) CEILING SYSTEM
AutoCAD SHX Text
1 HR FIRE RATING
AutoCAD SHX Text
ACOUSTICAL CEILING TILE
AutoCAD SHX Text
ACT
AutoCAD SHX Text
GYPSUM WALL BOARD
AutoCAD SHX Text
GWB
AutoCAD SHX Text
EXISTING PENDANT SPRINKLER HEAD
AutoCAD SHX Text PROVIDE NEW SUPPORT FOR CEILING GRID AROUND DUCTWORK, REPLACE WITH NEW TILES IN AREA OF WORK
AutoCAD SHX Text
TYPICAL FOR NUMBER OF ITEMS LISTED
AutoCAD SHX Text
TYP.
AutoCAD SHX Text EXIST'G WALLS SHALL BE PRIMED AND PAINTED W/ (2) COATS OF PAINT SIMILAR TO SHERWIN WILLIAMS (COLOR #6119) ANTIQUE WHITE, ZERO VOC EGGSHELL FINISH(TYP. FOR WALL AREA WHERE CEILING WAS REMOVED AND NEW RETURN GRILLE IS INSTALLED)
AutoCAD SHX Text
EXISTING GYPSUM WALL
AutoCAD SHX Text NOTES: ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH AS THE CEILING "T" BAR SUSPENSION SYSTEM, LIGHT FIXTURES, ETC. PROVIDE A PIPE HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24 INCHES.
AutoCAD SHX Text
CHROME ESCUTCHEON PLATE
AutoCAD SHX Text
SUSPENDED CEILING
AutoCAD SHX Text
1" X " PIPE REDUCING 12" PIPE REDUCING COUPLING
AutoCAD SHX Text
EXISTING SPRINKLER BRANCH LINE
AutoCAD SHX Text
1" BLACK STEEL SCHEDULE40 PIPING, TYPICAL
AutoCAD SHX Text
PROVIDE LENGTH TO SUIT
AutoCAD SHX Text
PROVIDE LENGTH TO SUIT
AutoCAD SHX Text
PROVIDE NEW CHROME PENDANT SPRINKLER HEAD LOCATE CENTER OF TILE
AutoCAD SHX Text
TYPICAL NEW PENDANT SPRINKLER
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
CRIPPLE STUD
AutoCAD SHX Text
CLIP ANGLES DESIGNED BY STUD MANUF..
AutoCAD SHX Text
HEADER CONNECTOR TRACK
AutoCAD SHX Text
%%UWALL OPENING HEADER
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
DOUBLE JAMB STUDS FULL HEIGHT WITH WOOD STUD BLOCKING
AutoCAD SHX Text No. 10 x 1/2" PAN HEAD SELF-DRILLING SCREW (TYP)
AutoCAD SHX Text
BOX HEADER AND JAMB
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
(1)#10-16 SCREW TYP. EACH FLANGE
AutoCAD SHX Text
(2) UNPUNCHED STUDS.
AutoCAD SHX Text ATTACH TOP & BOTTOM TRACK USING: (2)#10-16 SCREWS @ 24"o.c.
AutoCAD SHX Text
BUILT-UP HEADER
AutoCAD SHX Text
SEE PLAN FOR
AutoCAD SHX Text
WALL SURFACE
AutoCAD SHX Text
PROVIDE WOOD
AutoCAD SHX Text
BLOCKING IN
AutoCAD SHX Text
HEADER AND JAMB
AutoCAD SHX Text
HEADER AND JAMB FRAMING DETAIL
AutoCAD SHX Text
EXIST'G 9'-6" CEILING HEIGHT
AutoCAD SHX Text
PROVIDE NEW WALL OPENING
AutoCAD SHX Text
FOR SUPPLY AND RETURN
AutoCAD SHX Text
DUCTWORK - SEE MECH. DWGS.
W2018-362-01
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
P A
R
TI
A L
FL
O
O R
P
LA
N
H
VA
C D
E M
O
LI
TI
O
N
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
M-1
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
PARTIAL FLOOR PLAN - HVAC DEMOLITION
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text
%%UDEMOLITION KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EXISTING DUCTLESS EVAPORATOR UNITS TO BE REMOVED ALONG ALL REFRIGERANT AND DRAIN PIPING, WIRING, HANGERS, CONTROLS AND ALL RELATED APPURTENANCES.
AutoCAD SHX Text EXISTING DUCTWORK TO BE REMOVED ALONG WITH ALL INSULATION, HANGERS AND ALL RELATED APPURTENANCES TO LIMITS SHOWN. RELOCATE DIFFUSER TO NEW LOCATION SHOWN.
AutoCAD SHX Text
1. ALL DUCTWORK PIPING AND EQUIPMENT SHALL BE ALL DUCTWORK PIPING AND EQUIPMENT SHALL BE REMOVED FOR A COMPLETE NEW INSTALLATION, ALL DEMOLITION MAY NOT BE SHOWN FOR CLARITY, FIELD VERIFY ALL MECHANICAL EQUIPMENT TO BE REMOVED. 2. AT AREAS WHERE ABOVE CEILING WORK IS TO TAKE PLACE, AT AREAS WHERE ABOVE CEILING WORK IS TO TAKE PLACE, THE CEILING TILES AND GRID SHALL BE REMOVED FOR DEMOLITION AND REINSTALLED ONCE THE NEW WORK IS COMPLETE.
AutoCAD SHX Text
%%UDEMOLITION NOTES
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text EXISTING WALL MOUNTED CONDENSING UNITS TO BE REMOVED ALONG ALL REFRIGERANT PIPING, WIRING, HANGERS, CONTROLS AND ALL RELATED APPURTENANCES. (TYPICAL FOR THREE)
AutoCAD SHX Text
EXIST'G RETURN
AutoCAD SHX Text
DUCTWORK
AutoCAD SHX Text
EXIST'G SUPPLY
AutoCAD SHX Text
DUCTWORK
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
LRP14
AutoCAD SHX Text
EXIST'G CONDENSERS TO REMAIN SERVING ROOM 116
AutoCAD SHX Text
THIRD CONDENSING UNIT
AutoCAD SHX Text
MOUNTED ON WALL BELOW
AutoCAD SHX Text
CAULK ALL EXIST'G WALL
AutoCAD SHX Text
OPENINGS WATERTIGHT AS WELL AS
AutoCAD SHX Text
ALL SUPPORT BRACKET OPENINGS
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
P A
R
TI
A L
FL
O
O R
P
LA
N
H
VA
C N
E W
W O
R K
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
M-2
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
PARTIAL FLOOR PLAN - HVAC NEW WORK
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text 36"x18"
AutoCAD SHX Text 36"x14"
AutoCAD SHX Text 30"x14"
AutoCAD SHX Text 26"x12"
AutoCAD SHX Text 16"x12"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text 14"x8"
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text MOUNT & SECURE ACC UNIT ON 4" HIGH CONCRETE PAD 6" BIGGER THAN UNIT ALL AROUND, MAINTAIN CLEARANCES REQUIRED BY MANUF.
AutoCAD SHX Text
EXIST'G CONDENSERS
AutoCAD SHX Text
RL & RS LINES DROP
AutoCAD SHX Text
AT WALL
AutoCAD SHX Text
RL & RS LINES DROP AT WALL
AutoCAD SHX Text
CHWS & CHWR LINES DROP AT WALL
AutoCAD SHX Text
EXIST'G 3" CHWR TO CHILLER
AutoCAD SHX Text
EXIST'G 6" CHWS TO SYSTEM
AutoCAD SHX Text
EXIST'G 6" CHWS FROM CHILLER
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CONNECT NEW 2" CHWS TO
AutoCAD SHX Text
EXIST'G 6" CHWS AFTER PUMPS
AutoCAD SHX Text
CONNECT NEW 2" CHWR TO
AutoCAD SHX Text
EXIST'G 3" CHWR BACK TO CHILLER
AutoCAD SHX Text
PROVIDE BALL VALVE AT EACH
AutoCAD SHX Text
CONNECTION AND A FLOW CONTROL
AutoCAD SHX Text
BALANCING VALVE ON RETURN
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1B
AutoCAD SHX Text
CRU
AutoCAD SHX Text 1A
AutoCAD SHX Text
CRU
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
3/4" CONDENSATE LINE
AutoCAD SHX Text
DROP AT WALL
AutoCAD SHX Text
3/4" CONDENSATE LINE THRU
AutoCAD SHX Text
WALL AT 12" ABOVE GRADE
AutoCAD SHX Text
DISCHARGE TO SPLASH BLOCK
AutoCAD SHX Text
SLEEVE AND CAULK ALL WALL PENETRATIONS WATERTIGHT
AutoCAD SHX Text 2"
AutoCAD SHX Text
AutoCAD SHX Text
COORDINATE NEW DUCTWORK
AutoCAD SHX Text
WITH EXIST'G RELOCATE DUCTWORK
AutoCAD SHX Text
AS REQUIRED FOR NEW INSTALLATION
AutoCAD SHX Text
SEE SECTION
AutoCAD SHX Text
DETAIL ON M-4
AutoCAD SHX Text
SMOKE DETECTOR, PROVIDED
AutoCAD SHX Text
AND WIRED BY ELEC. CONTR.
AutoCAD SHX Text
INSTALLED BY HVAC CONTR.
AutoCAD SHX Text T
AutoCAD SHX Text S
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
LE
G
E N
D A
N D
G E
N E
R A
L N
O
TE
S
H
VA
C
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
M-3
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
DIRECTION OF FLOW (PUMPED)
AutoCAD SHX Text T
AutoCAD SHX Text
DIFFUSER MARK (CFM)
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
FLOW CONTROL BALANCING VALVE
AutoCAD SHX Text
2-WAY CONTROL VALVE
AutoCAD SHX Text
PIPE CAP
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
DEG., %%D%%
AutoCAD SHX Text
EWB
AutoCAD SHX Text
DEGREES
AutoCAD SHX Text
ENTERING WET BULB
AutoCAD SHX Text
AS
AutoCAD SHX Text
BD
AutoCAD SHX Text
APD
AutoCAD SHX Text
ACC
AutoCAD SHX Text
BACKDRAFT DAMPER
AutoCAD SHX Text
AIR COOLED CONDENSING UNIT
AutoCAD SHX Text
AIR PRESSURE DROP
AutoCAD SHX Text
AIR SEPARATOR
AutoCAD SHX Text
SAT
AutoCAD SHX Text
SA
AutoCAD SHX Text
RA
AutoCAD SHX Text
MD
AutoCAD SHX Text
OA
AutoCAD SHX Text
SUPPLY AIR TEMPERATURE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
MBH
AutoCAD SHX Text
1000 BTU'S PER HOUR
AutoCAD SHX Text
DIRECTION OF PITCH (GRAVITY FLOW)
AutoCAD SHX Text
DDC
AutoCAD SHX Text
DIRECT DIGITAL CONTROL
AutoCAD SHX Text
CFM
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
EAT
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYPICAL (AT ALL SIMILAR CONDITIONS)
AutoCAD SHX Text
3-WAY CONTROL VALVE
AutoCAD SHX Text
WPD
AutoCAD SHX Text
WATER PRESSURE DROP
AutoCAD SHX Text
CONDENSATE DRAIN PIPING (A/C)
AutoCAD SHX Text D
AutoCAD SHX Text
ESP
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
ER
AutoCAD SHX Text
EXHAUST REGISTER
AutoCAD SHX Text P
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
CRU
AutoCAD SHX Text
COMPUTER ROOM UNIT
AutoCAD SHX Text
CPS
AutoCAD SHX Text
CONDENSATE PUMP SET
AutoCAD SHX Text
CHILLED WATER SUPPLY PIPING
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHILLED WATER RETURN PIPING
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
RETURN/EXHAUST AIR DUCT SECTION (NEGATIVE)
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
SUPPLY AIR DUCT SECTION (POSITIVE)
AutoCAD SHX Text 12"x10"
AutoCAD SHX Text
DUCTWORK SIZE (IN WIDTH X IN HEIGHT)
AutoCAD SHX Text
EQUIPMENT TAG
AutoCAD SHX Text
RL
AutoCAD SHX Text
REFRIGERANT LIQUID
AutoCAD SHX Text
RS
AutoCAD SHX Text
REFRIGERANT SUCTION
AutoCAD SHX Text
DIA., %%C
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
SUPPLY AIR DIFFUSER
AutoCAD SHX Text
RETURN OR EXHAUST AIR GRILLE
AutoCAD SHX Text
LDB
AutoCAD SHX Text
LEAVING DRY BULB
AutoCAD SHX Text
COND
AutoCAD SHX Text
CONDENSING UNIT
AutoCAD SHX Text
DCU
AutoCAD SHX Text
DUCTLESS COOLING UNIT
AutoCAD SHX Text
MCA
AutoCAD SHX Text
MINIMUM CIRCUIT AMPS
AutoCAD SHX Text
WC
AutoCAD SHX Text
INCHES OF WATER COLUMN
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
AutoCAD SHX Text
FD
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
OBD
AutoCAD SHX Text
OPPOSED BLADE DAMPER
AutoCAD SHX Text
REGISTER/GRILLE MARK (CFM)
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text R
AutoCAD SHX Text
EXISTING WORK SHOWN LIGHT
AutoCAD SHX Text
NEW WORK SHOWN DARK
AutoCAD SHX Text
CONNECT TO EXISTING
AutoCAD SHX Text
EXISTING PIPING OR EQUIPMENT TO BE REMOVED
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
PRESSURE GAUGE
AutoCAD SHX Text
PRESSURE RELIEF VALVE
AutoCAD SHX Text
TEMPERATURE GAUGE
AutoCAD SHX Text
PIPE RISE OR UP
AutoCAD SHX Text
PIPE DROP OR DOWN
AutoCAD SHX Text
VACUUM BREAKER
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
BACKDRAFT DAMPER
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text
MD
AutoCAD SHX Text
BD
AutoCAD SHX Text
FD
AutoCAD SHX Text
VD
AutoCAD SHX Text
REFRIGERANT SUCTION
AutoCAD SHX Text
RS
AutoCAD SHX Text
REFRIGERANT LIQUID
AutoCAD SHX Text
RL
AutoCAD SHX Text
ANGLE GLOBE VALVE
AutoCAD SHX Text
BUTERFLY VALVE
AutoCAD SHX Text
VD
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
LPS
AutoCAD SHX Text
LOW PRESSURE STEAM
AutoCAD SHX Text
LPR
AutoCAD SHX Text
LOW PRESSURE RETURN
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text
RH
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
EDB
AutoCAD SHX Text
ENTERING DRY BULB
AutoCAD SHX Text
LWB
AutoCAD SHX Text
LEAVING WET BULB
AutoCAD SHX Text
WTD
AutoCAD SHX Text
WATER TEMPERATURE DROP
AutoCAD SHX Text
EWT
AutoCAD SHX Text
ENTERING WATER TEMPERATURE
AutoCAD SHX Text
LWT
AutoCAD SHX Text
LEAVING WATER TEMPERATURE
AutoCAD SHX Text 34.
AutoCAD SHX Text 35.
AutoCAD SHX Text 36.
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 28.
AutoCAD SHX Text 5.
AutoCAD SHX Text 6.
AutoCAD SHX Text 7.
AutoCAD SHX Text 8.
AutoCAD SHX Text 9.
AutoCAD SHX Text 10.
AutoCAD SHX Text 11.
AutoCAD SHX Text
THERMOSTATS SHALL BE LOCATED IN THE ROOMS INDICATED. INSTALL AT 4'-0"
AutoCAD SHX Text 12.
AutoCAD SHX Text 13.
AutoCAD SHX Text 14.
AutoCAD SHX Text 15.
AutoCAD SHX Text
NO HYDRONIC PIPING SHALL BE SMALLER THAN 3/4" UNLESS OTHERWISE NOTED.
AutoCAD SHX Text 16.
AutoCAD SHX Text
RUNOUTS SHALL PITCH DOWN IN DIRECTION OF FLOW A MINIMUM OF 1/8" PER FOOT.
AutoCAD SHX Text 17.
AutoCAD SHX Text 18.
AutoCAD SHX Text 19.
AutoCAD SHX Text 20.
AutoCAD SHX Text 21.
AutoCAD SHX Text 29.
AutoCAD SHX Text 22.
AutoCAD SHX Text
CORRECT SETTING ON BALANCING FITTINGS SHALL BE PERMANENTLY MARKED.
AutoCAD SHX Text 23.
AutoCAD SHX Text 24.
AutoCAD SHX Text
FOR LOCATION OF MOTOR STARTERS, SEE ELECTRICAL DRAWINGS.
AutoCAD SHX Text
PROVIDE MANUAL AIR VENTS AT HIGH POINTS OF SYSTEM.
AutoCAD SHX Text 25.
AutoCAD SHX Text 26.
AutoCAD SHX Text 27.
AutoCAD SHX Text
PROVIDE MINIMUM PITCH SUFFICIENT TO INSURE ADEQUATE VENTING AND DRAINAGE.
AutoCAD SHX Text 30.
AutoCAD SHX Text 31.
AutoCAD SHX Text 32.
AutoCAD SHX Text 33.
AutoCAD SHX Text
DAMPER MOTORS AND/OR MOTOR OPERATED DAMPERS.
AutoCAD SHX Text
FIRE DAMPERS AND SMOKE DAMPERS.
AutoCAD SHX Text INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
AutoCAD SHX Text PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, AND/OR EQUIPMENT TO MATCH EXISTING ADJACENT CONSTRUCTION.
AutoCAD SHX Text PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, SPECIFIED AND AS REQUIRED BY CODE.
AutoCAD SHX Text
FIELD VERIFY ALL DIMENSIONS.
AutoCAD SHX Text UNLESS INDICATED OTHERWISE, PIPING AND DUCTWORK TO BE REMOVED SHALL INCLUDE ASSOCIATED HANGERS, INSULATION, AND OTHER APPURTENANCES.
AutoCAD SHX Text IT IS THE INTENTION OF THE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A COMPLETE FIRST CLASS INSTALLATION. ANY EQUIPMENT, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF WORK (AS DETERMINED BY THE CONTRACTING OFFICER) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK.
AutoCAD SHX Text 37.
AutoCAD SHX Text 38.
AutoCAD SHX Text 39.
AutoCAD SHX Text 40.
AutoCAD SHX Text 41.
AutoCAD SHX Text 42.
AutoCAD SHX Text 43.
AutoCAD SHX Text ENTIRE INSTALLATION, INCLUDING MATERIALS, EQUIPMENT, AND WORKMANSHIP, SHALL CONFORM WITH ALL UFC GUIDELINES AND UFGS SPECIFICATIONS, APPLICABLE LAWS, CODES, AND REGULATIONS OF MUNICIPAL, STATE, AND FEDERAL AUTHORITIES, ALSO THE LATEST EDITION OF THE STATE BUILDING CODES, APPLICABLE ARI STANDARDS AND OTHER REGULATORY BODIES HAVING JURISDICTION OVER THE CLASS OF WORK. WHERE APPLICABLE, MATERIALS AND EQUIPMENT SHALL HAVE STAMPS OR SEALS OF ARI, ASME, UL, OR ASTM. THE CONTRACTOR SHALL MAKE TESTS FOR ACCEPTANCE AND APPROVAL BY CODE AND THE REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES. REQUIRED TESTS SHALL BE PERFORMED IN THE PRESENCE OF THE GOVERNMENT UNLESS OTHERWISE WAIVED IN WRITING.
AutoCAD SHX Text CONTRACTOR SHALL GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION.
AutoCAD SHX Text EXISTING DUCTWORK, PIPE, AND EQUIPMENT SIZES NOTED ARE FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND ARE NOT WARRANTED TO BE CORRECT. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DUCT, PIPE, AND EQUIPMENT SIZES AND THEIR RESPECTIVE LOCATIONS BEFORE PROCEEDING WITH ANY WORK.
AutoCAD SHX Text CUT OPENINGS, AS REQUIRED, IN THE EXISTING CONSTRUCTION FOR THE INSTALLATION OF NEW DUCTWORK, PIPING, AND EQUIPMENT. PATCH AND REPAIR TO MATCH THE EXISTING ADJACENT CONSTRUCTION. NEW OPENINGS IN EXISTING CONCRETE MASONRY CONSTRUCTION SHALL BE SAW CUT.
AutoCAD SHX Text LAYOUT OF PIPING IS DIAGRAMMATIC. RUN ALL EXPOSED PIPING AS HIGH AS POSSIBLE UNLESS OTHERWISE NOTED. ALLOW FOR RISES, DROPS, AND OFFSETS AS REQUIRED.
AutoCAD SHX Text AFTER THE PIPING IS INSULATED, PROVIDE SETON BRAND OR EQUAL FACTORY-FABRICATED PIPE LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE PIPING, AT 10 FEET ON CENTER ON THE PIPING MAINS AND 5 FEET ON CENTER ON THE BRANCH RUNOUTS FROM MAINS.
AutoCAD SHX Text TAB WORK: TAB EACH PHASE AFTER PHASE COMPLETION AND TAB COMPLETE BUILDING SYSTEM AFTER ALL PHASES ARE COMPLETE.
AutoCAD SHX Text CONSTRUCTION PHASING: THE BUILDING WILL REMAIN OCCUPIED AND IN-SERVICE THROUGHOUT THE CONSTRUCTION PROCESS. PHASING OF THE WORK WILL BE REQUIRED TO ACCOMPLISH THIS GOAL. ONLY PARTIAL SHUT DOWN OF THE BUILDING WILL BE PERMITTED. THE CONTRACTOR'S OPERATION SHALL CAUSE MINIMAL DISTURBANCE TO THE DAILY OPERATIONS OF THE REMAINDER OF THE BUILDING. A BUILDING ESCORT WILL BE REQUIRED FOR THIS WORK.
AutoCAD SHX Text 44.
AutoCAD SHX Text 45.
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text OUTSIDE AIR INTAKE OPENINGS FOR VENTILATION AIR SHALL BE LOCATED 10 FEET MEASURED IN ANY DIRECTION FROM ANY FLUES, VENTS, CHIMNEYS, PLUMBING VENTS UNLESS TOP OF SUCH INTAKE OPENING IS 2 FEET BELOW ANY OF THE LISTED ITEMS.
AutoCAD SHX Text EXTEND DRAIN LINES AS INDICATED. ROUTING SHALL NOT INTERFERE WITH PASSAGEWAYS AND MAINTENANCE. DRAINS FROM AIR CONDITIONING CONDENSATE DRAIN PANS SHALL BE TRAPPED AND INSULATED. SLOPE SUSPENDED CONDENSATE DRAIN PIPING AT 1/8" PER FOOT.
AutoCAD SHX Text
SECURITY BARS
AutoCAD SHX Text COORDINATE LOCATION OF GRILLES, REGISTERS, DIFFUSERS, THERMOSTATS AND OTHER WALL OR CEILING MOUNTED HVAC ACCESSORIES WITH THE EXISTING REFLECTED CEILING. REMOVE SECTIONS OF CEILING GRID AS NEEDED TO ALLOW FOR THE OPERATION OF LIFTS AND/OR THE ERECTION OF SCAFFOLDING. ANY DAMAGE MADE TO THE CEILING GRID STRUCTURE AS A RESULT OF WORK ASSOCIATED WITH THIS CONTRACT SHALL BE REPLACED BY THE CONTRACTOR.
AutoCAD SHX Text ARRANGE PIPING AND DUCTWORK, PARTICULARLY ABOVE CEILING, AS REQUIRED TO CLEAR STRUCTURE, DUCTS, CONDUIT, ETC. ALLOWING SPACE FOR PIPE HANGERS, EXPANSION LOOPS AND ACCESS TO VALVES, FILTERS AND MAINTENANCE OF EQUIPMENT.
AutoCAD SHX Text EQUIPMENT WITH FILTERS SHALL BE INSTALLED SO THAT FILTERS CAN BE EASILY REMOVED AND REPLACED.
AutoCAD SHX Text OVERHEAD DUCTWORK AND PIPING IN SPACES WITH CEILINGS SHALL BE CONCEALED OR IN WALLS OR CHASES UNLESS OTHERWISE NOTED.
AutoCAD SHX Text OVERHEAD PIPING IN SPACES WITHOUT HUNG CEILINGS SHALL BE RUN AS CLOSE TO ROOF DECK AS PRACTICABLE, AS CLOSE TO PARALLEL JOISTS AS POSSIBLE AND ABOVE LIGHTING FIXTURES TO CONCEAL PIPING.
AutoCAD SHX Text GENERAL NOTES ON THIS DRAWING ARE APPLICABLE TO EACH MECHANICAL DRAWING OF THIS SET. SEE EACH DRAWING FOR SPECIFIC NOTES APPLICABLE TO THAT DRAWING.
AutoCAD SHX Text COORDINATE LOCATION AND INSTALLATION OF EQUIPMENT WITH OTHER TRADES. DUCTWORK AROUND OBSTRUCTIONS AT NO ADDITIONAL COST TO OFFSET PIPING AND THE GOVERNMENT.
AutoCAD SHX Text CONTRACTOR SHALL VERIFY REFRIGERANT PIPE SIZES WITH EQUIPMENT MANUFACTURER FOR THE INDICATED INSTALLATION.
AutoCAD SHX Text VALVES AND SPECIALTIES SHALL BE LINE SIZE, EXCEPT FOR CONTROL & BALANCING VALVES OR UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
ABOVE FINISH FLOOR.
AutoCAD SHX Text PIPING AND DUCTWORK INSULATION SHALL BE RUN CONTINUOUSLY THROUGH NON- RATED FLOORS, WALLS AND PARTITIONS, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text FOR PIPE SIZES NOT INDICATED ON PLANS SEE EQUIPMENT MANUFACTURER CONNECTION DETAILS.
AutoCAD SHX Text PROVIDE UNION OR FLANGED CONNECTIONS AT EACH PIECE OF EQUIPMENT AND ON BOTH SIDES OF CONTROL VALVES AND PRESSURE REGULATING VALVES. PROVIDE SHUT-OFF VALVES ON BOTH SIDES OF AUTOMATIC VALVES.
AutoCAD SHX Text RELIEF VALVE DRAIN PIPING SHALL BE EXTENDED TO 6" (150) ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.
AutoCAD SHX Text PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE SPECIFICATION. ADDITIONAL SUPPORTS OR HANGERS SHALL BE ADJACENT TO ELBOWS, TO PREVENT WEIGHT OF PIPING BEING PLACED ON THE EQUIPMENT.
AutoCAD SHX Text LOCATE AND SIZE CONCRETE PADS AND CURBS FOR MECHANICAL EQUIPMENT IN ACCORDANCE WITH ACTUAL EQUIPMENT PURCHASED.
AutoCAD SHX Text PROVIDE 1/2" DRAIN VALVES AND CAPPED CONNECTIONS AT LOW POINTS IN PIPING SYSTEMS FOR DRAINAGE.
AutoCAD SHX Text PROVIDE SWING JOINTS FOR RUNOUTS AND BRANCH PIPING FROM MAINS FOR EXPANSION MOVEMENT.
AutoCAD SHX Text PROVIDE A MINIMUM OF THREE TIMES THE FAN DIAMETER OF STRAIGHT DUCTWORK OFF THE SUPPLY AIR DISCHARGE BEFORE ANY TAKEOFFS OR ELBOWS.
AutoCAD SHX Text PROVIDE ACCESS DOORS IN DUCTWORK WHERE INDICATED OR REQUIRED FOR ACCESS TO SYSTEM COMPONENTS INCLUDING THE FOLLOWING:
AutoCAD SHX Text EXISTING HVAC PIPING, DUCTWORK AND EQUIPMENT SHOWN IS BASED ON EXISTING AND FIELD OBSERVATION WITHOUT DEMOLITION. DURING DEMOLITION, ANY CLARIFICATION REQUIRED TO DETERMINE SCOPE OF WORK SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER.
AutoCAD SHX Text THE CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS, PROIR TO STARTING DEMOLITION.
AutoCAD SHX Text DRAWINGS DO NOT SHOW EVERY EXISTING PIPE, CONDUIT, DUCT, ETC. CONTRACTOR SHALL TAKE CARE TO REMOVE ONLY ITEMS REQUIRED TO BE REMOVED AND VERIFY PIPES, DUCTS, ETC. BEFORE REMOVAL.
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text S
AutoCAD SHX Text
SMOKE DETECTOR
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
S C
H E
D U
LE
A
N D
D E
TA
IL
S H
E E
T
- H
VA
C
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
M-4
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
ADJ. HANGER W/ ROLLER
AutoCAD SHX Text
(PIPE OVER 3")
AutoCAD SHX Text
PIPE SIZE
AutoCAD SHX Text
UP TO 2"
AutoCAD SHX Text 2.5", 3"
AutoCAD SHX Text
INSULATION SHIELD
AutoCAD SHX Text
GALVANIZED
AutoCAD SHX Text
12" LONG
AutoCAD SHX Text
HANGER ROD SCHEDULE
AutoCAD SHX Text
(PIPE UP TO 3")
AutoCAD SHX Text
CLEVIS HANGER
AutoCAD SHX Text
SADDLE
AutoCAD SHX Text
PIPE COVERING
AutoCAD SHX Text
PROTECTION
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
SUPPORTING NUT
AutoCAD SHX Text
LOCKING NUT
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
THIS CONNECTION SHALL BE USED AT ALL
AutoCAD SHX Text
BRANCHES FROM MAINS AND SUB-MAINS.
AutoCAD SHX Text
BALANCING DAMPERS SHALL BE PROVIDED.
AutoCAD SHX Text
%%UBRANCH CONNECTION DETAILS
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text 6"
AutoCAD SHX Text 45%%D
AutoCAD SHX Text
VOLUME DAMPER (VD.)
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
OPPOSED BLADE
AutoCAD SHX Text
DUCT MAIN
AutoCAD SHX Text
DIFFUSER
AutoCAD SHX Text
T-BAR
AutoCAD SHX Text
SUSPENDED
AutoCAD SHX Text
%%UDIFFUSER CONNECTION DETAIL
AutoCAD SHX Text
CEILING DIFFUSER (TYP,)
AutoCAD SHX Text
SPIN TAP SHALL
AutoCAD SHX Text
BE FULL SIZE OF
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
NECK
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
BAND
AutoCAD SHX Text
BAND AT DIFFUSER
AutoCAD SHX Text
NECK
AutoCAD SHX Text
ATTACH METALLIC FLEX
AutoCAD SHX Text
DUCT TO DIFFUSER
AutoCAD SHX Text
DIFFUSER NECK
AutoCAD SHX Text
WITH VD.
AutoCAD SHX Text
NECK WITH BAND
AutoCAD SHX Text
MAX 5'-0"
AutoCAD SHX Text
ROD SIZE
AutoCAD SHX Text
PIPE SIZE
AutoCAD SHX Text
ROD SIZE
AutoCAD SHX Text 3/8"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text 4" & 5"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text 6"-14"
AutoCAD SHX Text 7/8"
AutoCAD SHX Text
%%UPIPE HANGER DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
THIS CONNECTION SHALL BE USED AT ALL
AutoCAD SHX Text
BRANCHES FROM MAINS AND SUB-MAINS.
AutoCAD SHX Text
VOLUME DAMPERS SHALL BE PROVIDED.
AutoCAD SHX Text
%%UTEE BRANCH CONNECTION DETAILS
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
VOLUME DAMPER (VD.)
AutoCAD SHX Text
MAIN DUCT
AutoCAD SHX Text
BRANCH DUCT
AutoCAD SHX Text
DOUBLE THICKNESS
AutoCAD SHX Text
TURNING VANES
AutoCAD SHX Text
VOLUME DAMPER (VD.)
AutoCAD SHX Text
INSULATE DIFFUSER NECK
AutoCAD SHX Text
FAN TOTAL STATIC + 1"
AutoCAD SHX Text
UNIT
AutoCAD SHX Text
THRU
AutoCAD SHX Text
DRAW-
AutoCAD SHX Text
NOTE A
AutoCAD SHX Text
NOTE B
AutoCAD SHX Text
2" MIN
AutoCAD SHX Text B.
AutoCAD SHX Text A.
AutoCAD SHX Text
EXTEND TO LOCATION INDICATED.
AutoCAD SHX Text
DRAIN SHALL BE FULL SIZE OF UNIT CONNECTION.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
REMOVABLE CAP W/ 1/4" HOLE
AutoCAD SHX Text
%%UDRAIN PAN TRAP DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
#4 @ 12" O/C EACH WAY
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
3/4" CHAMFER
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
%%UEXTERIOR EQUIPMENT PAD DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text 8"
AutoCAD SHX Text 4"
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CIRCUIT SETTER
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
OPEN/CLOSE 3 WAY
AutoCAD SHX Text
CONTROL VALVE
AutoCAD SHX Text
TRAP
AutoCAD SHX Text
DRAIN PAN
AutoCAD SHX Text D
AutoCAD SHX Text
COIL
AutoCAD SHX Text
%%UCHILLED WATER COIL DETAIL
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
UNION
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
1/2" DRAIN VALVE
AutoCAD SHX Text
BALANCING VALVE
AutoCAD SHX Text
MARK
AutoCAD SHX Text S/A
AutoCAD SHX Text CEILING 24"x24" FLAT LAY-IN
AutoCAD SHX Text
SUPPLY DIFFUSER SCHEDULE
AutoCAD SHX Text
DIMENSION
AutoCAD SHX Text
(IN)
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
THROW
AutoCAD SHX Text BASIS OF DESIGN PRICE INDUSTRIES. DIFFUSERS MODEL AMDX AND SHALL BE WELDED WITH MULTI ORIFICED JET INDUCTION WITH DIFFUSING VANES AND OPPOSED BLADE DAMPERS.
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
1-WAY
AutoCAD SHX Text 12"x12"
AutoCAD SHX Text
SCALE: 1/2" = 1'-0"
AutoCAD SHX Text
%%USECTION THROUGH NEW CRU(TYPICAL)
AutoCAD SHX Text 18"x36" SA
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1A
AutoCAD SHX Text
CRU
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
NEW ACT CEILING
AutoCAD SHX Text
RAISED FLOOR
AutoCAD SHX Text 32"x58" SA DUCT CONNECTION
AutoCAD SHX Text
AT TOP OF UNIT, MAY VARY
AutoCAD SHX Text
BASED ON MANUF. SELECTED
AutoCAD SHX Text 38"x48" RA DUCT CONNECTION
AutoCAD SHX Text
AT BACK OF UNIT, MAY VARY
AutoCAD SHX Text
BASED ON MANUF. SELECTED
AutoCAD SHX Text
4" FLEX CONNECTION
AutoCAD SHX Text
4" FLEX CONNECTION
AutoCAD SHX Text
MARK
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
COMPUTER ROOM UNIT DUEL COOL SPLIT SYSTEMS SCHEDULE
AutoCAD SHX Text NOTES: 1. AIR COOLED SPLIT SYSTEM WITH FLOOR MOUNTED EVAPORATOR WITH DX AND CHILLED WATER ECONOCOIL W/ 35% PROPYLENE GLYCOL AND REMOTE DX CONDENSER WITH COATED COILS. : 1. AIR COOLED SPLIT SYSTEM WITH FLOOR MOUNTED EVAPORATOR WITH DX AND CHILLED WATER ECONOCOIL W/ 35% PROPYLENE GLYCOL AND REMOTE DX CONDENSER WITH COATED COILS. 2. COPPER TUBE/ALUMINUM FIN FOR EVAPORATOR COIL. 3. CONDENSING UNIT SHALL BE ABLE TO OPERATE AT LOW AMBIENT TEMPERATURE AS LOW AS -30°F. 4. PROVIDE BUILT IN CONDENSATE PUMP. 5. PROVIDE RIGHT SIDE PIPING CONNECTIONS. 6. SMOKE DETECTOR. 7. REMOTE TEMPERATURE SENSORS. 8. PROVIDE DISCHARGE PLENUM, FLOOR STAND, ELECTRIC REHEAT, COND PUMP, WATER DETECTION, AND INTERFACE CARD.
AutoCAD SHX Text
CRU-1A
AutoCAD SHX Text
ROOM 114
AutoCAD SHX Text
STYLE
AutoCAD SHX Text
FLOOR MOUNTED, INDOOR
AutoCAD SHX Text 5.0
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
MBH
AutoCAD SHX Text
AutoCAD SHX Text
HP
AutoCAD SHX Text
SENSIBLE
AutoCAD SHX Text
MBH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CRU-1B
AutoCAD SHX Text
GRADE MOUNTED, OUTDOOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CFM
AutoCAD SHX Text
REHEAT
AutoCAD SHX Text 0.5"
AutoCAD SHX Text
FAN
AutoCAD SHX Text
ESP
AutoCAD SHX Text
AutoCAD SHX Text
HUMIDIFIER
AutoCAD SHX Text
COND.
AutoCAD SHX Text
PUMP
AutoCAD SHX Text
EDB
AutoCAD SHX Text
LDB
AutoCAD SHX Text
AMBIENT
AutoCAD SHX Text
FLA
AutoCAD SHX Text
MOP
AutoCAD SHX Text
VOLTAGE
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
HZ
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BUILT-IN
AutoCAD SHX Text
LBS/HR
AutoCAD SHX Text
KW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 15.0
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OUTSIDE
AutoCAD SHX Text
BASIS OF DESIGN LIEBERT MODELS VSO42DD DUAL COOL EVAPORATOR, MCM080E8 CONDENSER.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
MBH
AutoCAD SHX Text
AutoCAD SHX Text
SENSIBLE
AutoCAD SHX Text
MBH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EDB
AutoCAD SHX Text
LDB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CHILLED WATER COIL
AutoCAD SHX Text
DX COIL
AutoCAD SHX Text 45/52
AutoCAD SHX Text
EWT/LWT
AutoCAD SHX Text
GPM
AutoCAD SHX Text
AutoCAD SHX Text
CHILLED WATER COIL
AutoCAD SHX Text
EXTEND NEW RL, RS, CHWS AND CHWR TO CONN. ON UNIT
AutoCAD SHX Text
RS
AutoCAD SHX Text
RS
AutoCAD SHX Text
RL
AutoCAD SHX Text
RL
AutoCAD SHX Text
CONN NEW 3/4" COND. TO
AutoCAD SHX Text
PUMPED DISCHARGE ON UNIT
AutoCAD SHX Text
EXTEND 2" CHWS & CHWR
AutoCAD SHX Text
BACK TO MECH. ROOM
AutoCAD SHX Text
EXTEND 3/4" COND. DRAIN
AutoCAD SHX Text
TO OUTSIDE
AutoCAD SHX Text
PROVIDE ACCESS PANEL FOR SECURITY BARS
AutoCAD SHX Text
ACT CEILING
AutoCAD SHX Text
SECURITY BARS, SEE
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
RETURN AIR GRILLE
AutoCAD SHX Text
SEE SCHEDULE
AutoCAD SHX Text
12" HIGH UNIT
AutoCAD SHX Text
FLOOR STAND
AutoCAD SHX Text
FILTER BOX SUPPLIED
AutoCAD SHX Text
WITH UNIT
AutoCAD SHX Text
MAINTAIN REQUIRED CLEARANCE
AutoCAD SHX Text
FROM WALL FOR FILTER
AutoCAD SHX Text
REPLACEMENT
AutoCAD SHX Text D
AutoCAD SHX Text
SECURITY BARS, SEE
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
MARK
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
RETURN REGISTER SCHEDULE
AutoCAD SHX Text DIMENSION WxH(IN)
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text R/1
AutoCAD SHX Text 48"x38"
AutoCAD SHX Text
ALUMINUM
AutoCAD SHX Text
SIDEWALL HEAVY DUTY RETURN GRILLE
AutoCAD SHX Text
BASIS OF DESIGN PRICE INDUSTRIES MODEL 99, 30° DEFLECTION.
AutoCAD SHX Text 3"x3"x1/4" STEEL ANGLE FRAME-SECURE TO WALL WITH 1/4" THRU BOLTS AT 12" ONCENTER AND MAXIMUM 6" FROM OUTSIDE OF ANGLE FRAME. LOCK NUTS SHALL BE PROVIDED ON SECURE SIDE.
AutoCAD SHX Text 1/2" VERTICAL STEEL BARS ATMAXIMUM 6" ON CENTER. WELD BOTH ENDS OF BARS TO STEEL ANGLE FRAME. WELD BARS AT ALL CONNECTIONS TO HORIZONTAL BARS
AutoCAD SHX Text 1/2" HORIZONTALSTEEL BARS AT MAXIMUM 6" ON CENTER. WELD BOTH ENDS OF BARS TO STEEL ANGLE FRAME. WELD BARS AT ALL CONNECTIONS TO VERTICAL BARS
AutoCAD SHX Text 1-1/2"x1-1/2"x16 GA. ANGLE (TYPICAL)
AutoCAD SHX Text
PROVIDE AIRTIGHT SEAL AT ALL DUCT CONNECTIONS
AutoCAD SHX Text
NEW DUCTWORK
AutoCAD SHX Text
%%USECURITY BARS DETAIL
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
PROVIDE 1/8" FLAT PLATE
AutoCAD SHX Text
ON OPPOSITE SIDE OF
AutoCAD SHX Text
WALL TO SECURE FRAME
AutoCAD SHX Text
EXIST'G METAL STUD WALL
AutoCAD SHX Text
EXIST'G SUBGRADE
AutoCAD SHX Text 8"
AutoCAD SHX Text 8" THICK LAYER 95% COMPACTION IN 4" LIFTS RIDOT RECLAIMED AND PROCESSED AGGREGATE BASE
AutoCAD SHX Text
REFER TO ARCH. PLAN
AutoCAD SHX Text
FOR FRAMED OPENING
AutoCAD SHX Text
DETAIL
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
P A
R
TI
A L
FL
O
O R
P
LA
N
E
LE
C
TR
IC
A
L D
E M
O
LI
TI
O
N
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
E-1
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
PARTIAL FLOOR PLAN - ELECTRICAL DEMOLITION
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
LRP14, 208V/3PH
AutoCAD SHX Text
EXIST'G CONDENSERS
AutoCAD SHX Text
%%UDEMOLITION NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EXISTING SURFACE MOUNTED LIGHT FIXTURE, LAMPS, AND HANGERS TO BE REMOVED, INCLUDING ALL RELATED APPURTENANCES ABOVE CEILING. THE CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE OF THE EXISTING RECESSED FLUORESCENT LIGHT FIXTURES (TYPICAL OF APPROX. 4) AND ASSOCIATED CONDUITS AND CONDUCTORS TO PANELBOARD LP1 IN ROOM 118, CIRCUIT NUMBERS AS INDICATED. THE LIGHT FIXTURES ARE SURFACE ON THE EXISTING GYPSUM CEILING AT 9'-6" AFF. THE LAMPS AND BALLASTS SHALL BE PACKAGED IN SUITABLE CARDBOARD BOXES, PROVIDED BY THE CONTRACTOR, AND CLEARLY LABELED. THE CONTRACTOR SHALL PROPERLY DISPOSE/RECYCLE OF THE BALLASTS AND THE LAMPS IN ACCORDANCE WITH ALL APPLICABLE STATE AND FEDERAL LAWS.
AutoCAD SHX Text
LRP14-4,6
AutoCAD SHX Text
LRP14-12,14
AutoCAD SHX Text
LRP14-8,10
AutoCAD SHX Text
LRP14-4,6
AutoCAD SHX Text
LRP14-8,10
AutoCAD SHX Text
LRP14-12,14
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text
DUCTLESS COOLING UNITS REMOVED(TYP. FOR 3) SEE MECH. PLANS
AutoCAD SHX Text REMOVE EXISTING DISCONNECT, WIRE AND CONDUIT BACK TO PANEL LRP14 SERVING EXISTING CEILING RECESSED DUCTLESS COOLING UNIT.
AutoCAD SHX Text
AutoCAD SHX Text REMOVE EXISTING DISCONNECT, WIRE AND CONDUIT BACK TO PANEL LRP14 SERVING EXISTING OUTSIDE WALL MOUNTED CONDENSING UNITS.
AutoCAD SHX Text
AutoCAD SHX Text
LP1-2
AutoCAD SHX Text
CONDENSING UNITS REMOVED(TYP. FOR 3) SEE MECH. PLANS
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
PP1
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
PP4
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
DP-2
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
DP-1
AutoCAD SHX Text
AutoCAD SHX Text EXISTING SMOKE DETECTOR TO REMAIN AND BE PROTECTED DURING CONSTRUCTION. RELOCATE AND MOUNT ON NEW CEILING SEE DRAWING E-2.
AutoCAD SHX Text Sa
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text EXISTING LIGHT SWITCH TO REMAIN, THE CONTRACTOR SHALL MODIFY THE EXISTING CONDUIT AND WIRING TO ACHIEVE NEW LIGHTING DESIGN ON DRAWING E-2.
AutoCAD SHX Text
AutoCAD SHX Text EXIST'G LIGHTING CIRCUIT ALSO SERVES ROOM 116 LIGHTING FIXTURES. COORDINATE POWER OUTAGE FOR LIGHTING REPLACEMENT WITH LAB 116
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
LP1
AutoCAD SHX Text EXISTING 30 AMP BREAKERS IN PANEL LRP14 SERVING EXIST'G COOLING UNITS SHALL REMAIN AND BECOME SPARES
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
P A
R
TI
A L
FL
O
O R
P
LA
N
E
LE
C
TR
IC
A
L N
E W
W O
R K
B U
IL
D
IN
G
R
O O
M
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
K . B
O U
LD
S
E-2
5/
/1
19-021A
5/
/1
5/
/1
AutoCAD SHX Text
AutoCAD SHX Text
PARTIAL FLOOR PLAN - ELECTRICAL NEW WORK
AutoCAD SHX Text
SCALE: 1/4" =1'-0"
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 114B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
EXIST'G CONDENSERS
AutoCAD SHX Text 1A
AutoCAD SHX Text
CRU
AutoCAD SHX Text
%%UCONSTRUCTION NOTES
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
PP1
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
PP4
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
DP-2
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
DP-1
AutoCAD SHX Text
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
LP1
AutoCAD SHX Text 1B
AutoCAD SHX Text
CRU
AutoCAD SHX Text
EXIST'G PANEL
AutoCAD SHX Text
LRP14, 208V/3PH
AutoCAD SHX Text
3P 30NF
AutoCAD SHX Text
3P 60NF
AutoCAD SHX Text
PP1-14,16,18
AutoCAD SHX Text
PP1-13,15,17
AutoCAD SHX Text a
AutoCAD SHX Text F1
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text F1
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text F1
AutoCAD SHX Text
AutoCAD SHX Text a
AutoCAD SHX Text F1
AutoCAD SHX Text
AutoCAD SHX Text
SPRINKLER HEAD(TYP.)
AutoCAD SHX Text
LP1-2
AutoCAD SHX Text Sa
AutoCAD SHX Text
AutoCAD SHX Text THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW 277V 2'X2' RECESSED LED LIGHT FIXTURES, TYPE F1 (TYPICAL OF OF APPROX. 4) , AND ASSOCIATED CONDUIT AND CONDUCTORS , AND ASSOCIATED CONDUIT AND CONDUCTORS , AND ASSOCIATED CONDUIT AND CONDUCTORS CONDUCTORS (2-#12+#12 GND AWG CU THWN-2 IN 3/4" EMT, MC CABLE WHIP AT FIXTURE ENTRY) TO PANELBOARD LP1, CIRCUIT NUMBERS AS INDICATED. MOUNTED IN THE NEW SUSPENDED CEILING GRID PER MANUFACTURER'S SPECIFICATIONS. PROVIDE JACK CHAINS OR SUSPENSION WIRES AT EACH CORNER TO STRUCTURE ABOVE. DO NOT SUPPORT BY CEILING GRID. THE CONTRACTOR SHALL RE-USE THE FOLLOWING EXISTING SIEMENS TYPE BL BRANCH CIRCUIT BREAKERS IN PANELBOARD LP1 FOR POWER TO THE NEW LIGHT FIXTURES, CIRCUIT NUMBERS AS INDICATED.
AutoCAD SHX Text
AutoCAD SHX Text THE CONTRACTOR SHALL REUSE THE 277V 20A 2-WAY IVORY LIGHT SWITCH, AND ASSOCIATED CONDUIT AND CONDUCTORS CONDUIT AND CONDUCTORS (#12 CU THWN-2 IN 3/4" EMT), FOR SWITCHING THE NEW THWN-2 IN 3/4" EMT), FOR SWITCHING THE NEW SWITCHING THE NEW LED LIGHT FIXTURES AS INDICATED.
AutoCAD SHX Text
REINSTALL EXISTING SMOKE DETECTOR AT LOCATION SHOWN, AND
AutoCAD SHX Text
RECONNECT TO EXISTING FEEDS.
AutoCAD SHX Text
AutoCAD SHX Text
NEMA 4X 480V, 3 PH, 30 AMP NON FUSED DISCONNECT SWITCH.
AutoCAD SHX Text
NEMA 1 480V, 3 PH, 60 AMP NON FUSED DISCONNECT SWITCH.
AutoCAD SHX Text
CEILING DIFFUSER(TYP.)
AutoCAD SHX Text
3 #12 & #12 GND
AutoCAD SHX Text
IN 3/4" EMT
AutoCAD SHX Text
3 #8 & #10 GND
AutoCAD SHX Text
IN 1" EMT
AutoCAD SHX Text S
AutoCAD SHX Text
NEW DUCT SMOKE DETECTOR
AutoCAD SHX Text
PROVIDED AND WIRED BY
AutoCAD SHX Text
ELEC. CONTR. INSTALLED BY
AutoCAD SHX Text
HVAC CONTR.
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
RI
N
G C
O M
M
AN
D
N
EW
PO
RT
, R H
O D
E
IS
LA
N
D
FA
C
IL
IT
IE
S
BR
AN
C
H N
A
VA
L U
N D
E R
S E
A W
A R
FA
R
E C
E N
TE
R
D
IV
IS
IO
N
SHEET OF
CONTRACT NO.
NAVFAC DRAWING NO.
NUWC DRAWING NO.
SCALE:
SIZE: ANSI D
A P
P R
O
VE
D
C H
E C
K E
D B
Y
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
D A
TE
S A
TI
S
FA
C
TO
R
Y
TO
D A
TE
D A
TE
D A
TE
D A
TE
SEAL
R E
VI
S
IO
N
S S
YM
D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
AS NOTED
4/ X/
LE
G
E N
D , N
O
TE
S
S C
H E
D U
LE
S
E
LE
C
TR
IC
A L
B U
IL
D
IN
G
R
O O
M
19-021A
K . B
O U
LD
S
R . N
E
LS
O N
A D
D E
D C
O O
LI
N
G
W2018-362-01
K . B
O U
LD
S
E-3
4/ X/
4/ X/
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text ELECTRICAL CONTRACTOR (E.C.) SHALL FURNISH AND INSTALL A NEW PULL/JUNCTION BOX AND DISCONNECT FOR EACH PIECE OF MECHANICAL EQUIPMENT NOTED. EXTERIOR BOX AND DISCONNECT SHALL BE STAINLESS STEEL AND SIZED TO SUIT THE EXISTING AND NEW EQUIPMENT WIRING . EQUIPMENT SHALL BE IN CONFORMANCE WITH THE NATIONAL ELECTRICAL CODE.
AutoCAD SHX Text ELECTRICAL CONTRACTOR (E.C.) SHALL VISIT THE SITE PRIOR TO THE BID TO FAMILIARIZE THEMSELVES WITH THE EXISTING BUILDING CONDITIONS WHICH AFFECT THE COSTS FOR THE WORK. DIFFERING FIELD CONDITIONS DUE TO A LACK OF EXISTING SITE CONDITIONS INFORMATION IS NOT ELIGIBLE FOR ADDITIONAL COMPENSATION.
AutoCAD SHX Text E.C. SHALL FIELD MEASURE ALL EXISTING WIRING PHYSICAL LOCATIONS IN ORDER TO SHALL FIELD MEASURE ALL EXISTING WIRING PHYSICAL LOCATIONS IN ORDER TO MODIFY AS REQUIRED FOR THE NEW MECHANICAL EQUIPMENT LOCATION AND WIRING. E.C. SHALL PROVIDE ASSISTANCE TO THE MECHANICAL CONTRACTOR ON LOCATIONS OF THE NEW EQUIPMENT IN ORDER TO PROVIDE PROPER ELECTRICAL WORKING CLEARANCES.
AutoCAD SHX Text E.C. IN ACCORDANCE WITH THE CONSTRUCTION SCHEDULE SHALL DISCONNECT AND IN ACCORDANCE WITH THE CONSTRUCTION SCHEDULE SHALL DISCONNECT AND SELECTIVELY DEMOLISH THE EXISTING POWER WIRING. WORK INCLUDES TAGGING ALL EXISTING WIRING TO BE RE-USED INCLUDING PROVIDING PROPER EQUIPMENT LOCK-OUTS AS REQUIRED BY OSHA AND EM-385.
AutoCAD SHX Text E.C. SHALL COORDINATE ALL NEW ELECTRICAL WIRING WITH THE "AS-SUPPLIED" SHALL COORDINATE ALL NEW ELECTRICAL WIRING WITH THE "AS-SUPPLIED" EQUIPMENT. NO ROUGH WIRING SHALL BE STARTED UNTIL THE NEW EQUIPMENT FIELD INTERCONNECTION WIRING DIAGRAMS ARE COMPLETED TO ALLOW THE E.C. TO DETERMINE THE NECESSARY POWER, AND INTERLOCKING WIRING. E.C. SHALL PREPARE AND SUBMIT INTERCONNECTION FIELD WIRING DIAGRAMS FOR THE NEW SYSTEM. NEW DIAGRAMS SHALL INDICATE THE EXISTING FIELD WIRING AND THE NECESSARY WIRING REVISIONS. ALL NEW WIRING SHALL BE RUN IN CONDUIT.
AutoCAD SHX Text E.C. SHALL MAKE ALL FINAL WIRING TERMINATIONS TO THE NEW EQUIPMENT UNDER THE DIRECT SUPERVISION/REVIEW/APPROVAL OF THE MANUF. REPRESENTATIVE. E.C. SHALL TAKE ALL ELECTRICAL MEASUREMENTS AS REQUESTED BY THE REPRESENTATIVE DURING EQUIPMENT START-UP AND TESTING.
AutoCAD SHX Text
%%UELECTRICAL DEMOLITION NOTES
AutoCAD SHX Text
%%UELECTRICAL CONSTRUCTION NOTES
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL AND NATIONAL ELECTRONIC CODE INCLUDING GROUNDING OF THE NEW EQUIPMENT AND WIRING.
AutoCAD SHX Text ALL ELECTRICAL MATERIAL AND INSTALLATION SHALL BE NEW AND FURNISHED/INSTALLED IN ACCORDANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS.
AutoCAD SHX Text THE PROPOSED LOCATION OF THE NEW EQUIPMENT AND WIRING IS DIAGRAMATIC ONLY. ELECTRICAL CONTRACTOR SHALL MAKE FIELD REVISIONS AS NECESSARY TO SUIT THE EXISTING FIELD CONDITIONS AND THE "AS-SUPPLIED" MECHANICAL EQUIPMENT.
AutoCAD SHX Text NO NEW ELECTRICAL WORK SHALL COMMENCE UNTIL THE EXISTING FIELD SURVEYS ARE COMPLETED AND THE NEW EQUIPMENTS WIRING REQUIREMENTS ARE COORDINATED. PROPER COORDINATION SHALL BE SUBSTANTIATED BY THE SUBMITTAL/APPROVAL OF THE EXISTING AND NEW FIELD WIRING INTERCONNECTION WIRING DIAGRAMS BY THE E.C.
AutoCAD SHX Text ALL NEW/REVISED POWER SUPPLIES AND WIRING SHALL BE IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURER REQUIREMENTS. THE E.C.