This document is a Questions and Answers (Q&A) for Request for Quote (RFQ) N6426725Q4211, providing technical specifications for two identical items. The technical details include a differential pressure range of 60-110 PSI (4.14-7.58 BAR), a safe working pressure of 500 PSI (34 BAR), and construction materials of 316 Stainless Steel for both the pressure housing and bellows. The process connection size is 1/4" X 1/4" FNPT, with no specific mounting method specified.
The Q&A also addresses special cleaning requirements, with oxygen cleaning mandated for both items: Class I cleaning per Mil-Std-1330 for item 1, and Class II cleaning meeting CGA G-4.1 standards for item 2. If connections are needed, the units will be connected to a 316C Barton DP Flow Indicator with a 4.5-inch dial size. The document does not provide pricing, award dates, or specific details about the federal agency beyond the RFQ number.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0001.pdf | ||
| Combined_Synopsis Solicitation.pdf | ||
| Brand name justification_Redacted.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers for RFQ N6426725Q4211
Both items have the same specs:
Questions:
1. What is the Differential Pressure (D.P.) Range?
Answer: 60-110 PSI (4.14-7.58 BAR)
2. What is the Safe Working Pressure?
Answer: 500 PSI (34 BAR)
3. What is the Pressure Housing Material?
Answer: 316 Stainless Steel
4. What is the Bellows Material?
Answer: 316 Stainless Steel
5. What is the Process Connection Size?
Answer: 1/4" X 1/4" FNPT
6. What is your method of mounting?
Answer: (None) No mounting. If any connection is to be made the units will be connected to 316C Barton DP Flow Indicator with dial size 4.5 in.
7. Does your unit require any special cleaning?
Answer: Oxygen cleaning is required, Class I for item 1•Class I is Oxygen Cleaning per Mil-Std-1330
• Class II for item 2 is Oxygen Cleaning requirements meet CGA G-4.1