7. Table 1. B201 Rooms GFE-CFE Lists and Summary of Upgrades.pdf
PDF 438 KB Posted
- Attached to
- Building 201 Conference Room Upgrade
- Solicitation number
- N6426724Q5032
About this file
This document is a table providing a list of equipment and upgrades for six conference rooms in Building 201. The table includes details on the existing and new Government Furnished Equipment (GFE) and Contractor Furnished Equipment (CFE) for each room, as well as a summary of the integrator's upgrades.
The related federal contract opportunity is for the Building 201 Conference Room Upgrade project. This is a commercial items solicitation for an all-or-none requirement, with proposals due by the response date. The Government will award a single purchase order to the responsible Offeror whose proposal conforms to the requirements and is most advantageous based on the stated evaluation criteria. Offerors must be registered in SAM, and all responsible sources may submit a quote.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1. Team Submarine Conference Room Upgrades - B201 Rooms GFE-CFE Lists and Summary of Upgrades Rev 16
Room
Count
WNY
Building Room
VTC/Web Conferencing
Support Reused Equipment (GFE) List New Equipment (CFE) List Summary of Integrator Upgrades
1 201 2E-310 Cisco Webex Room USB
1 - Podium/lectern with 15 RU of
19" rack space 2 - Sharp 65" class
LSD 1 - Surge X SEQ-1U
1 - AMX Enova DVX-3266-4K 1 - AMX
Modero G5 MT-702 1 - Panasonic PT-
VMZ60U7 1 - Webex Room USB 4 -
JBL Control 26CT
Integrator: Remove existing legacy classified/unclassified VTC equipment. Replace existing AV switch and control with
AMX DVX and MT-702. Retain and reuse unclassified 15RU equipment rack/podium as required; Retain and reuse two
(2) existing large screen displays; Retain and reuse one Surge X SEQ-1U. Replace existing projector with Panasonic laser projector. Add Webex Room USB above 65" class LSD's. Install six (6) JBL Control 26CT speakers in ceiling.
2 201 2W-310 Cisco Webex Room USB
1- Podium/lectern with 15 RU of
19" rack space 2 - Sharp 65" class
LSD 1 - Surge X SEQ-1U
1 - AMX Enova DVX-3266-4K 1 -
AMX Modero G5 MT-702 1 -
Panasonic PT-VMZ60U7 1 - Webex
Room USB 4 - JBL Control 26CT
Integrator: Remove existing legacy classified/unclassified VTC equipment. Replace existing AV switch and control with
AMX DVX and MT-702. Retain and reuse unclassified 15RU equipment rack/podium as required; Retain and reuse two
(2) existing large screen displays; Retain and reuse one Surge X SEQ-1U. Replace existing projector with Panasonic laser projector. Add Webex Room USB above 65" class LSD's. Install six (6) JBL Control 26CT speakers in ceiling.
3 201 2W-480 Cisco Webex Room USB
1- Alesis MultiMix 8 FX mixer 4 -
Audio Technica Pro 44 boundary microphones 1 - Belkin
F1DN104MOD-BA-4 with host and console cables
1 - 19" Half-rack equipment cabinet, 20 RU 2 - 65" class Samsung QB65R-
N 1 - AMX Enova DVX-3266-4K 1 -
AMX Modero G5 MT-702 1 - Surge X
SEQ-1U 1 - Webex Room USB 6 - JBL
Control 26CT
Integrator: Install 19" half-rack equipment cabinet with 20 RU rack space. Install one Surge X SEQ-1U. Install new AMX
DVX and MT-702 AV switch and control system. Retain and reuse one Belkin F1DN104MOD-BA-4 with host and console cables. Retain and reuse existing DCS audio integration with Alesis MultiMix 8 FX Audio Technica Pro 44 or equal for
Line In. Install Guest laptop port (HDMI/Display port) for conference table. Replace existing display on north wall with
65" class LSD. Add second 65" class LSD on the north wall. Add Webex Room USB on the north wall and centered to suit.
Reroute surface cables for conference table under Velcro cable foot traffic protector. Install six (6) JBL Control 26CT speakers in ceiling.
4 201
3E-
010/3W-
Cisco Webex Room USB Owl
Labs Owl 3 Room Kit
1 - 19" Half-rack equipment cabinet, 20 RU 1- Podium/lectern with 15 RU of 19" rack space 2 -
Samsung QB75N-N 75" LSD 1 -
Surge X SEQ-1U
1 - AMX Enova DVX-3266-4K 1 - AMX
Modero G5 MT-702 1 - Panasonic PT-
VMZ60U7 1 - Webex Room USB 8 -
JBL Control 26CT 1 - Owl Labs Owl 3
Integrator: Remove existing legacy classified/unclassified VTC equipment. Replace existing AV switch and control with
AMX DVX and MT-702. Retain and reuse unclassified equipment rack/podium as required; Retain and reuse two (2) existing large screen displays. Retain and reuse one Surge X SEQ-1U. Replace existing projector with Panasonic laser projector. Add Webex Room USB above 75" class LSD's, Owl Labs Owl 3 on conference table. Install six (6) JBL Control
26CT speakers in ceiling.
5 201 4W-322 Cisco Webex Room USB/Owl
Labs Owl 3
1 - 19" Half-rack equipment cabinet, 20 RU 1 - Surge X SEQ-1U
1- 65" class Samsung QB65R-N 1 -
AMX Enova DVX-3266-4K 1 - AMX
Modero G5 MT-702 1 - Webex Room
USB 4 - JBL Control 26CT 1 - Owl
Labs Owl 3
Integrator: Remove existing legacy classified/unclassified VTC equipment. Replace existing AV switch and control with
AMX DVX and MT-702. Retain and reuse unclassified equipment rack as required. Retain and reuse one Surge X SEQ-
1U. Replace existing display with 65" class LSD. Retain the current location of the large screen display. Add Webex
Room USB above 65" class LSD. Install six (6) JBL Control 26CT speakers in ceiling.
6 201 4E-180 1015AJ Self-contained
Classified IP VTC
1 - 19" Half-rack equipment cabinet, 20 RU 1 - Belkin F1DN104MOD-BA-4 with host and console cables
2- 65" class Samsung QB65R-N 1 -
AMX Enova DVX-3266-4K 1 - AMX
Modero G5 MT-702 4 - JBL Control
26CT 1 - Surge X SEQ-1U
Integrator: Remove existing legacy classified/unclassified VTC equipment. Replace existing AV switch and control with
AMX DVX and MT-702. Retain and reuse unclassified equipment rack as required; Retain and reuse one Belkin
F1DN104MOD-BA-4 with host and console cables. Install one Surge X SEQ-1U. Replace existing 50" large screen display with new 65" LSD. Retain the current location of the large screen display. Add second 65" class LSD. Install six (6) JBL
Control 26CT speakers in ceiling.
Table 1. B201 Rooms GFE-CFE Lists and Summary of Upgrades Rev 16 08302023.xlsx
File details come from the government source that posted it. Updated .