3D_Metal_Print_Lab_Upgrade_V2_DRAWINGS.pdf
PDF 739 KB Posted
- Attached to
- 3D METAL ADDITIVE UPGRADE LAB
- Solicitation number
- N6426720Q0005
About this file
LAB DRAWINGS
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMENDMENT.docx | DOCX document | |
| AMENDMENT.docx | DOCX document | |
| DI-MGMT-80227.pdf | ||
| Visitor_Notification_5530.pdf | ||
| A004_-_Performance_and_Cost_Report.pdf | ||
| Attachment_4_-_CA20190025.pdf | ||
| DI-MGMT-81991.pdf | ||
| DI-FNCL-80912.pdf | ||
| A005_-_Contractor's_Personnel_Roster.pdf | ||
| DI-SESS-81002.pdf | ||
| SOLICITATION.docx | DOCX document | |
| A002_-_Developmental_Design_DrawingsModels_and_Associated_Lists.pdf | ||
| A001-CONTRACTOR'S_PROGRESS_STATUS_AND_MANAGEMENT_REPORT.pdf | ||
| A003_-_System_Safety_Program_Plan_(SSPP).pdf | ||
| DI-SAFT-81626.pdf | ||
| A006_-_Contract_Status_Report.pdf | ||
| Attachment_3_-_Minimum_5512-1_Completion_Requirements.pdf | ||
| DI-MGMT-81834.pdf | ||
| 5512_FORM.docx | DOCX document |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
T-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
SHEET# DESCRIPTION
T-1 TITLE SHEET
C-1 B575 FLOOR PLAN
D-1 ROOM 117 DEMO PLAN
D-2 HVAC DEMO PLAN
A-1 ROOM 117 RENOVATION PLAN
A-2 FURNACE LOCATION RENOVATION PLAN
M-1 HVAC MODIFICATION PLAN
E-1 ROOM 117 ELECTRICAL PLAN
F-1 ROOM 117 EQUIPMENT LAYOUT PLAN
3D METAL PRINTER LAB
INDEX OF DRAWINGS: GENERAL NOTES:
1. ALL WORK SHALL CONFORM TO 2015 INTERNATIONAL BUILDING CODE AS AMENDED BY UNIFIED
FACILITIES CRITERIA (UFC 1-200-01), NFPA 484,
2. ALL ACCESSIBILITY WORK SHALL COMPLY WITH 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN, "2010
STANDARDS"
3. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, DETERMINING EXTENT OF DEMOLITION, AND
COORDINATE WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND ENGINEER IN WRITING PRIOR TO START OF WORK.
TENANT IMPROVEMENT AND RENOVATIONS
PROJECT DESCRIPTION:
THIS PROJECT CONSISTS OF REMODELING THE FORMER WOODSHOP IN BUILDING 575 TO SUIT THE
INSTALLATION OF A METAL ADDITIVE MANUFACTURING LAB. THIS LAB WILL UTILIZE METAL POWDERS, SOME HIGHLY REACTIVE AND EXPLOSIVE, TO CREATE THREE-DIMENSIONAL COMPONENTS USING
LASER SINTERING. THE SPACE MUST THEREFORE CONFORM TO NFPA 484 AND UFC 3-600-01. THIS WILL
REQUIRE UPDATING ELECTRICAL, WALL AND CEILING CONSTRUCTION AND THE ADDITION OF AN
ELECTRICAL CLOSET. THE METAL SINTERING PROCESS ALSO REQUIRES THE USE OF INERT GAS
ATMOSPHERE SO INSTALLATION AND PLUMBING OF NITROGEN AND ARGON LINES WILL ALSO BE
NECESSARY. FINALLY, THE NEW EQUIPMENT WILL NEED TO BE CONNECTED AND COMMISSIONED TO
BEGIN USE.
CODE AND STANDARD:
1. OPNAVINST 5100.23G, NAVY SAFETY AND OCCUPATIONAL HEALTH PROGRAM MANUAL
2. NFPA 484 - STANDARD FOR COMBUSTABLE METALS
3. ASHRAE 62.1- VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
4. NFPA 70 - NATIONAL ELECTRICAL CODE
5. UFC 3-600-01 - FIRE PROTECTION ENGINEERING FOR FACILITIES
6. NFPA 101 - LIFE SAFETY CODE
7. ACGIH INDUSTRIAL VENTILATION MANUAL (29TH OR 30TH EDITION)
AREA MAP:
VICINITY MAP:
NORTH NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RIVER RD
AutoCAD SHX Text
MAIN ST
AutoCAD SHX Text
5TH ST
AutoCAD SHX Text
4TH ST
AutoCAD SHX Text
SANTA
AutoCAD SHX Text
ANA
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
HAMNER AVE
AutoCAD SHX Text
ARCHIBALD AVE
AutoCAD SHX Text
NAVAL WARFARE
AutoCAD SHX Text
ASSESSMENT STA
AutoCAD SHX Text
CALIFORNIA AVE
AutoCAD SHX Text
NORCO
AutoCAD SHX Text
DR
AutoCAD SHX Text
CORYDON
AutoCAD SHX Text
AVE
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text J
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text
W 6TH ST
AutoCAD SHX Text
MAIN GATE
AutoCAD SHX Text
ENTRANCE
AutoCAD SHX Text
6TH ST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
4TH ST
AutoCAD SHX Text
MAIN GATE
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
119A
119D
119G
101A
119H
119E 119F
119C
119B
BUILDING 575 FLOOR PLAN
SCALE: 1/32" = 1' - 0"
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
C-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
KEY NOTES:
1 ROOM 117 - 3D PRINT LAB.
2 NORTH EXTERIOR OF 117 - LOCATION OF ELECTRICAL CLOSET.
3 EAST BUILDING EXTERIOR - LOCATION OF WOOD DUST CYCLONE AND INERT GAS TANKS.
4 MACHINE SHOP EXPANSION NORTH EXTERIOR - LOCATION OF FURNACES.
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
AutoCAD SHX Text
96 SF
AutoCAD SHX Text
100 SF
AutoCAD SHX Text
154 SF
AutoCAD SHX Text
87 SF
AutoCAD SHX Text
106 SF
AutoCAD SHX Text
263 SF
AutoCAD SHX Text
80 SF
AutoCAD SHX Text
57 SF
AutoCAD SHX Text
476 SF
AutoCAD SHX Text
1,294 SF
AutoCAD SHX Text
73 SF
AutoCAD SHX Text
642 SF
AutoCAD SHX Text
1,984 SF
AutoCAD SHX Text
191 SF
AutoCAD SHX Text
193 SF
AutoCAD SHX Text
749 SF
AutoCAD SHX Text
2,366 SF
AutoCAD SHX Text
2,302 SF
AutoCAD SHX Text
2,014 SF
AutoCAD SHX Text
608 SF
AutoCAD SHX Text
591 SF
AutoCAD SHX Text
627 SF
AutoCAD SHX Text
582 SF
AutoCAD SHX Text
194 SF
AutoCAD SHX Text
577 SF
AutoCAD SHX Text
752 SF
AutoCAD SHX Text
352 SF
AutoCAD SHX Text
775 SF
AutoCAD SHX Text
37 SF
AutoCAD SHX Text
50 SF
AutoCAD SHX Text
37 SF
AutoCAD SHX Text
159 SF
AutoCAD SHX Text
180 SF
AutoCAD SHX Text
46 SF
AutoCAD SHX Text
984 SF
AutoCAD SHX Text
14,851 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
HOOD
AutoCAD SHX Text
FUME
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
IT
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
7' OCTAGON
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TRIDENT TOOLING
AutoCAD SHX Text
MASTER STORAGE AREA
AutoCAD SHX Text
POLAR Q. M. M.
AutoCAD SHX Text
ROTARY
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
14" OFF FLOOR
AutoCAD SHX Text
36" THK GRANITE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text
GRANITE
AutoCAD SHX Text
TABLE
AutoCAD SHX Text 120V
AutoCAD SHX Text
VICE
AutoCAD SHX Text
MITER
AutoCAD SHX Text
SAW
AutoCAD SHX Text
GRINDER
AutoCAD SHX Text
PRESS
AutoCAD SHX Text
VF 12
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
SES
AutoCAD SHX Text
BUILDING 575 FLOOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
ROOM 117 DEMO PLAN
SCALE: 1/8" = 1' - 0"
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
D-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
KEY NOTES:
1 REMOVE ALL TRANSFORMERS IN ROOM 117 AND SET ASIDE FOR FUTURE USE. MOUNT BOLTS MUST
ALSO BE REMOVED FROM FLOOR.
2 REMOVE ELECTRICAL PANELS FROM WITHIN ROOM 117 AND SET ASIDE FOR FUTURE USE.
3 REMOVE DISCONNECTS FROM ROOM 117 AND SET ASIDE FOR FUTURE USE.
4 REMOVE ALL REMAINING CONDUIT, J-BOXES, LIGHTS (INCLUDING CEILING), AND OTHER ELECTRICAL
COMPONENTS THAT ARE NOT CLASS 2 DIVISION 1 GROUPE E RATED.
5 REMOVE ALL DOORS THAT ARE NOT 2 HR FIRE RATED.
6 DEMO EXISTING DRYWALL THROUGHOUT ROOM 117.
7 DEMO EXISTING T-BAR CEILING AND ACOUSTIC PANELS.
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
AutoCAD SHX Text
12,987 SF
AutoCAD SHX Text
1,632 SF
AutoCAD SHX Text
ROOM 117 DEMO PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
D-2
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
HVAC DEMO PLAN
SCALE: 3/16" = 1'-0"
KEY NOTES:
1 CAREFULLY REMOVE AND RETURN TO GOVERNMENT WOOD DUST CYCLONE, DISCONNECT, AND
WIRING.
2 REMOVE AND RETURN TO GOVERNMENT COLLECTION MAIN BRANCH DUCTWORK FROM ABOVE
CEILING TILES
3 REMOVE AND RETURN TO GOVERNMENT COLLECTION DROPS DUCTWORK.
4 REMOVE EXISTING AIR TRANSFERS TO OPEN BAY.
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
AutoCAD SHX Text
4"%%C DN,
AutoCAD SHX Text 5"%%C
AutoCAD SHX Text 8"%%C
AutoCAD SHX Text 4"%%C
AutoCAD SHX Text 4"%%C
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text 4"%%C
AutoCAD SHX Text 4"%%C
AutoCAD SHX Text
4"%%C DN,
AutoCAD SHX Text 9"%%C
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text 10"%%C
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text 4"%%C
AutoCAD SHX Text 5"%%C
AutoCAD SHX Text
5"%%C DN,
AutoCAD SHX Text
4"%%C DN,
AutoCAD SHX Text
4"%%C DN,
AutoCAD SHX Text
14"%%C OUTLET
AutoCAD SHX Text 16"%%c
AutoCAD SHX Text 16"%%C
AutoCAD SHX Text 22x22 PRG
AutoCAD SHX Text
PSD
AutoCAD SHX Text 16"%%C
AutoCAD SHX Text
620 CFM
AutoCAD SHX Text
(TYP OF 2)
AutoCAD SHX Text 22x22
AutoCAD SHX Text 22x22
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text
HVAC DEMO PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
BATTERY
UPS
TRANSFORMERTRANSFORMER
A r
P
A N
E L
P
A N
N
E L
N
G E
N E
R A
T O
R
U P
S
B R
E A
K E
R
N2
TANK
TRANSFORMER
PLUMBING LEGEND
ARGON
NITROGEN
COMPRESSED AIR
WATER
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
A-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
ROOM 117 RENOVATION PLAN
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
KEY NOTES:
1 INSTALL ESD FLOORING SYSTEM
2 INSTALL TYPE X GYPSUM BOARD TO CREATE 2 - HR FIRE RATED BARRIER
3 INSTALL NEW 2 - HR FIRE RATED DOORS
4 INSTALL 2 - HR FIRE RATED, HARD-LID CEILING
5 CONFIGURE, INSTALL, AND ANCHOR LARGE ELECTRICAL COMPONENTS PER NFPA 70
6 INSTALL WATER LINE WITH SPIGOT TERMINATION AT 2' HEIGHT
7 INSTALL COMPRESSED AIR LINE WITH FILTRATION TO 2.2.2 AIR QUALITY, PRESSURE REGULATOR,BALL VALVES, AND
QUICK CONNECT FITTING.
8 INSTALL PLUMBED ARGON DISPENSING LINES FOR TANK BANK TO CONTROLLER THE FROM CONTROLLER TO END
TERMINATIONS WITH 2.2.2 FILTRATION, PRESSURE REGULATORS,BALL VALVES, AND QUICK DISCONNECT FITTINGS 9 INSTALL PLUMBED NITROGEN LINES FROM NITROGEN GENERATOR TO HOLDING TANK AND FROM TANK TO
TERMINATION POINTS WITH 2.2.2 FILTRATION, PRESSURE REGULATORS, BALL VALVES, AND QUICK DISCONNECTS.
10 INSTALL EXPANDED METAL CAGE WITH DOOR SURROUNDING ELECTRICAL AREA
11 INSTALL AND ANCHOR ASME CERTIFIED, 260 GAL. TANK FOR NITROGEN HOLDING
12 INSTALL ARGON TANK HOLDING RACK, CHAINS, BOTTLE CONNECTORS AND COMPRESSED CYLINDER CAGE WITH
SOLID ROOF .
13 INSTALL BOLLARDS SURROUNDING COMPRESSED GAS TANKS
AutoCAD SHX Text
920 SF
AutoCAD SHX Text
ROOM 117 RENOVATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
A-2
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
FURNACE LOCATION RENOVATION PLAN
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
KEY NOTES:
1 INSTALL STAINLESS STEEL WALL COVERING 10' WIDE X 8' TALL X 18" THICK
2 INSTALL HOOD VENT, IAW ACGIH INDUSTRIALVENTILATION MANUAL (29TH OR 30TH EDITION), OVER FURNACE
POSITION ABOVE STAINLESS WALL PLATE. EXHAUST TO EXTERIOR OF BUILDING
3 INSTALL FOUR (4) JUNCTION BOXES WITH 480V / 15A POWER TO EACH.
4 INSTALL WIRE RUNS IN CONDUIT TO ELECTRICAL PANEL.
5 INSTALL PLUMBED ARGON DISPENSING LINES FOR TANK BANK TO CONTROLLER THE FROM CONTROLLER TO END
TERMINATIONS WITH 2.2.2 FILTRATION, PRESSURE REGULATORS,BALL VALVES, AND QUICK DISCONNECT FITTINGS 6 INSTALL ARGON TANK HOLDING RACK, CHAINS, BOTTLE CONNECTORS AND COMPRESSED CYLINDER CAGE WITH
SOLID ROOF .
HOOD VENT CONCEPT
SCALE: NTS
AutoCAD SHX Text
AutoCAD SHX Text #4
AutoCAD SHX Text #5
AutoCAD SHX Text
VF 4
AutoCAD SHX Text
FURNACE LOCATION RENOVATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
M-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
ROOM 117 INTERIOR HVAC
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
2. ALL HVAC SYSTEMS MUST BE DESIGNED FOR PROPER FLOW
IN ACCORDANCE WITH ASHRAE 62.1
3. ROOM 117 MUST HAVE NEGATIVE PRESSURE TO PREVENT
THE SPREAD OF METAL DUST
4. ALL HVAC SYSTEMS MUST BE TESTED AND BALANCED
KEY NOTES:
1 DISCONNECT ROOM 117 SUPPLY FROM AHU 2 AND CONNECT TO AHU21
2 DISCONNECT ROOM 117 RETURN FROM AHU 2 AND CONNECT TO AHU 21
3 DISCONNECT MACHINE SHOP EXPANSION SUPPLY FROM AHU 21 AND CONNECT TO AHU 2
4 DISCONNECT MACHINE SHOP EXPANSION RETURN FROM AHU 21 AND CONNECT TO AHU 2
5 REPAIR AHU 21 TO PROPER WORKING ORDER
ROOM 117 MEZZANINE HVAC
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text 16"%%c
AutoCAD SHX Text 16"%%C
AutoCAD SHX Text 22x22 PRG
AutoCAD SHX Text
PSD
AutoCAD SHX Text 16"%%C
AutoCAD SHX Text
620 CFM
AutoCAD SHX Text
(TYP OF 2)
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AutoCAD SHX Text
AHU
AutoCAD SHX Text 22"%%C
AutoCAD SHX Text 22"%%C
AutoCAD SHX Text 20"%%C
AutoCAD SHX Text 16"%%c
AutoCAD SHX Text 16"%%c
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
EQUIP
AutoCAD SHX Text 20x12
AutoCAD SHX Text 20x12
AutoCAD SHX Text 26x20
AutoCAD SHX Text 24x16
AutoCAD SHX Text 26x20
AutoCAD SHX Text 14"%%C
AutoCAD SHX Text 14"%%C
AutoCAD SHX Text
NO
AutoCAD SHX Text
CHWS
AutoCAD SHX Text
CHWR
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HWR
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text
6"%%C DN TO RA DUCT
AutoCAD SHX Text 12"%%c DN TO
AutoCAD SHX Text
RA DUCT
AutoCAD SHX Text
CP-12
AutoCAD SHX Text 24x16
AutoCAD SHX Text 16"%%C
AutoCAD SHX Text 24x14
AutoCAD SHX Text
AutoCAD SHX Text
AHU
AutoCAD SHX Text
HVAC MODIFICATION PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
BATTERY
UPS
TRANSFORMERTRANSFORMER
A r
P
A N
N
N
E L
N
G E
N E
R A
T O
R
U P
S
B R
E A
K E
R
TRANSFORMER
ELECTRICAL LEGEND
400 V 3 PHASE
230 V SINGLE PHASE
110 V SINGLE PHASE
FROM MAIN
CLASS 2 DIVISION 1 BOUNDARY
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
E-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
ROOM 117 ELECTRICAL PLAN
SCALE: 1/8" = 1'-0"
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
2. ALL ELECTRICAL THAT PENETRATES 2 HR FIRE RATED
BARRIERS IS REQUIRED TO BE CLASS 2 DIVISION 1 GROUP E
RATED AND GAPS SEALED.
3. CONTRACTOR SHALL ROUTE ELECTRICAL SO THAT MINIMAL
CONDUIT, JUNCTION BOXES, AND OTHER COMPONENTS
RESIDE INSIDE THE FIRE WALL BARRIER.
KEY NOTES:
1 INSTALL CONNECTION FROM MAIN LINE TO 400V AND 230V TRANSFORMERS
2 INSTALL CONNECTION FROM 400V TRANSFORMER TO 400 V BREAKER PANEL
3 INSTALL CONNECTION FROM 230V TRANSFORMER TO 230 V BREAKER PANEL
4 INSTALL CONNECTION FROM 400V PANEL TO UPS BREAKER. CONNECT BREAKER, UPS AND BATTERY PER
MANUFACTURERS INSTRUCTION
5 INSTALL CONNECTION FROM UPS TO 3D PRINT MACHINE
6 INSTALL CONNECTION FROM 400V PANEL TO SIEVE
7 INSTALL CONNECTION FROM 230V PANEL TO BEAD BLASTING BOX AND RUAC VACUUM
8 INSTALL CONNECTION FROM 230V PANEL TO NITROGEN GENERATOR
9 INSTALL 110V OUTLETS AT STANDARD INTERVAL THROUGHOUT THE SPACE
10 INSTALL CONNECTION FROM SMALL 230V TRANSFORMER TO FORTUS PLASTIC PRINTER
AutoCAD SHX Text
920 SF
AutoCAD SHX Text
ROOM 117 ELECTRICAL PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BATTERY
UPS
TRANSFORMERTRANSFORMER
A r
P
A N
E L
N
G E
N E
R A
T O
R
U P
S
B R
E A
K E
R
POWDER
POWDER
POWDER
POWDER
POWDER
FORTUS
PLASTIC
WORK
TABLE
TRANSFORMER
DESK
3D M
E T
A L
P R
IN
T
E R
L A
B
-N O
R C
O D
E T
A C
H
Na va l W ea po ns
S ta tio n
Se al
B ea ch Se al B ea ch
, C al ifo rn ia
11x17
F-1
N A
V F
A C
S O
U T
H W
E S
T Sa n Di eg o, C al ifo rn ia
PM
BRANCH MANAGER
CHIEF ENG/ARCH
SIZE
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
SCALE:
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
CHK
OF
CONSTR. CONTR. NO.
EPROJECT NO.:
O
R
IG
IN
A
L D
E S
IG
N
/0
3/
NOTE: KEYNOTES REFER TO THIS SHEET ONLY
ROOM 117 EQUIPMENT LAYOUT PLAN
SCALE: 3/16" = 1'-0"
KEY NOTES:
1 GOVERNMENT WILL PLACE PRINTER IN ROOM. CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO
ELECTRICAL, COMPRESSED AIR, ARGON AND NITROGEN
2 CLEARANCE AREA SURROUNDING PRINTER SHALL BE OBSERVED AND VERIFIED
3 POWDER SIEVE SHALL BE PLACED, ANCHORED, AND CONNECTED TO ELECTRICAL, ARGON AND
NITROGEN
4 BEAD BLASTER SHALL BE PLACED AND CONNECTED TO ELECTRICAL AND COMPRESSED AIR
5 RUAC VACUUM SHALL BE PLACED AND CONNECTED TO ELECTRICAL
6 LIFT SHALL BE PLACED AND CHARGER CONNECTED TO ELECTRICAL
7 FORTUS PRINTER SHALL BE PLACED AND FINAL ELECTRICAL CONNECTIONS MADE
8 PLASTIC PRINTER SHALL BE PLACED AND FINAL ELECTRICAL CONNECTIONS MADE
9 FLAMMABLE CABINETS SHALL BE PLACED AND GROUNDED
GENERAL NOTES
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS,
DETERMINING EXTENT OF DEMOLITION, AND COORDINATE
WITH ALL OTHER TRADES. IN CASE OF DISCREPANCIES OR
ANY POTENTIAL CONFLICTS, INFORM THE ARCHITECT AND
ENGINEER IN WRITING PRIOR TO START OF WORK.
AutoCAD SHX Text
ROOM 117 EQUIPMENT LAYOUT PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
| Sheets and Views |
| 3D Meatal Print Lab Upgrade V2-T1 - TITLE SHEET |
| 3D Meatal Print Lab Upgrade V2-C1-FLOOR PLAN |
| 3D Meatal Print Lab Upgrade V2-D1-DEMO PLAN |
| 3D Meatal Print Lab Upgrade V2-D2-HVAC DEMO PLAN |
| 3D Meatal Print Lab Upgrade V2-A1-RENOVATION PLAN |
| 3D Meatal Print Lab Upgrade V2-A2-RENOVATION PLAN |
| 3D Meatal Print Lab Upgrade V2-M1 - HVAC MODIFICATION PLAN |
| 3D Meatal Print Lab Upgrade V2-E1 - ELECTRICAL PLAN |
| 3D Meatal Print Lab Upgrade V2-F1 - EQUIPMENT LAYOUT PLAN |
File details come from the government source that posted it.