Amendment 001 to IDIQ Contract Solicitation N6247026R0022

This is a presolicitation synopsis for an Indefinite Delivery/Indefinite Quantity (IDIQ) architect-engineer services contract with the Naval Facilities Engineering Systems Command (NAVFAC) for facilities with secured spaces compliant with ICD/ICS 705 standards worldwide. The contract will have a two-year base period with three optional one-year periods, a total contract value cap of $250,000,000, and a guaranteed minimum of $10,000. Firm-fixed price task orders will be negotiated with no dollar limit per task order or annual spending limit. The estimated contract start date is October 2027, and responses are due by 30 December 2026 at 2:00 PM EST submitted through the PIEE Solicitation Module. This unrestricted solicitation seeks the most highly qualified firm based on demonstrated competence across six primary selection criteria: Specialized Experience (most important), Professional Qualifications (most important), Past Performance, Program Management/Capacity/Location, Commitment to Small Business, and Volume of Work (least important as a tiebreaker).

The contract requires comprehensive A-E services including developing Requests for Proposals for Design-Build projects, preparing full design plans for Design-Bid-Build projects, conducting site investigations, producing studies and evaluations, implementing ICD/ICS 705 security requirements, supporting facility accreditation processes, incorporating TEMPEST countermeasures, providing post-construction services, developing cost estimates, and coordinating multiple technical disciplines. The prime contractor must possess an active SECRET Facility Clearance and demonstrate eligibility for SECRET clearance for the Program Manager and Project Manager positions. Key personnel must include specialists in ICD/ICS 705 security standards and RF shielding, each requiring U.S. citizenship and SECRET clearance eligibility with minimum five years of SCIF/SAPF experience. Submissions must include a completed SF330 (maximum 60 pages Part I), security clearance verification package, proof of AE firm registration or practice eligibility, joint venture agreement if applicable, CPARS evaluations or Past Performance Questionnaires for Criterion 1 projects, and for large businesses, a draft Small Business Subcontracting Plan demonstrating commitments to small business utilization goals (40% SB, 9% WOSB, 5% SDVOSB, 5% SDB, 3% HUBZone).

View the file

Other files

File Type Posted
N6247026R0022 Amendment 001.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment 001

Revised MAR 2026

N6247026R0022 INDEFINITE DELIVERY/ INDEFINITE QUANTITY (IDIQ) CONTRACT

FOR ARCHITECT-ENGINEER (A-E) SERVICES FOR FACILITIES WITH SECURED

SPACES LOCATED THROUGHOUT NAVAL FACILITIES ENGINEERING SYSTEMS

COMMAND AREA OF RESPONSIBILITY, WORLDWIDE

Description: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A

STANDARD FORM SF330, ARCHITECT ENGINEER QUALIFICATIONS IS

CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP)

PACKAGE TO DOWNLOAD.

Attachments: (a) Past Performance Questionnaire

(b) Small Business Subcontracting Plan Template

This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for multi-discipline Architect-Engineer (A-E) services for projects with Secured Spaces (spaces meeting ICD/ICS 705 (Physical and Technical Standards for SCIF) accreditation) at various military installations located throughout the Naval Facilities Engineering Systems Command (NAVFAC) Area of Responsibility (AOR) and may also include work worldwide. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, as implemented by FAR 36.102. The IDIQ contract will be for a base period of two years and three one-year option periods (if exercised). The total fee for the contract term shall not exceed $250,000,000. The guaranteed minimum for the contract term (including option years) is $10,000. Firm-fixed price task orders will be negotiated for this contract. There will be no dollar limit per task order and no dollar limit per year. Estimated start date is October 2027.

This proposed contract is being solicited on an UNRESTRICTED basis. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code 541310, Architectural Services. The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria.

The market research study (Sources Sought Number: N6247026R0022) conducted by NAVFAC Atlantic included an assessment of relevant qualifications and capabilities of potentially qualified small business firms. As a result of the market research analysis, a determination was made to solicit this procurement on an unrestricted basis inviting full and open competition. The NAVFAC Atlantic small business office concurs with this decision.

A-E services to be performed under this contract include:

Developing Requests for Proposals (RFPs) for Design-Build (DB) projects with Secured

Spaces.

Preparing full design plans and specifications for Design-Bid-Build (DBB) projects with

Secured Spaces.

Conducting site investigations to support new facility development on raw land, as well as redevelopment or modifications of existing sites and facilities.

Producing studies, reports, evaluations related to the designs of new facilities and the renovation or repair of existing facilities.

Preparation of planning and programming related documents to include DD1391s, design development plans, concept sketches, preliminary site plans with building footprints, geotechnical reports, and site civil survey data.

Implementing ICD/ICS 705 requirements into design plans, specifications, investigations, studies, evaluations, and recommendations for Secured Spaces within new and existing facilities. Specifically, but not limited to:

o Developing design requirements for Sensitive Compartmented Information Facilities (SCIFs)/Special Access Program Facilities (SAPFs).

o Ensuring compliance with and execution of Construction Security Plan (CSP).

o Serving as an ICD/ICS 705 subject-matter expert (SME) for planning, design and construction management support.

Supporting the facility accreditation process by:

o Providing Tenant Command or Site Security Manager (SSM) information requested for development of the Fixed Facility Checklist (FFC) o Providing information for TEMPEST Countermeasure Review (TCR) submittal to the Tenant Command

Incorporating all TEMPEST countermeasure mitigations into facility design Providing Post Construction Award Services (PCAS) Providing technical reviews during post-award design services for DB execution for facilities containing Secured Spaces Developing cost estimates Coordinating across multiple technical disciplines, including architecture, interior design, landscape architecture, civil, structural, mechanical, electrical, telecommunications, fire protection, planning, geotechnical engineering, industrial hygienist

Identifying existing asbestos-containing materials, lead-based paint, and other hazardous materials, along with recommending appropriate abatement methods

Types of projects with Secured Spaces may include, but are not limited to, new construction and repair/renovation of institutional, industrial, operational and training, and research and development facilities.

Interested firms are advised to ensure System of Award Management (SAM) registration is current at time of offer submission and at time of award. To be eligible for award, your firm(s) must be registered in the System for Award Management (SAM) database. For instructions on registering with SAM, see the SAM website at sam.gov.

The awarded contract will be subject to specific provisions addressing the avoidance of organizational conflicts of interest. The prime firm for this contract will be required to perform throughout the contract term.

Interviews may be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to clarify information contained in the SF330 submittal. Elaborate presentations are not desired.

SELECTION CRITERIA:

Firms responding to this synopsis will be evaluated to determine the most highly qualified firms to perform the required services in accordance with the published selection criteria. Failure to comply with instructions or provide complete information may affect the firm’s evaluation or disqualify the firm from further consideration. Criteria 1 and 2 are considered most important and of equal importance to each other; Criteria 3, 4, and 5 are of lesser importance and listed in descending order of importance; and Criterion 6 is of least importance and will be used as a tiebreaker among firms considered to be technically equal.

Specific selection criteria include:

1. Specialized Experience

2. Professional Qualifications

3. Past Performance

4. Program Management, Capacity, and Location

5. Commitment to Small Business

6. Volume of Work

Criterion 1- Specialized Experience (SF330, Part I, Section F):

Firms will be evaluated on specialized experience in performance of services similar to those anticipated under this contract through evaluation of experience in:

1. Design of renovations and/or repair of existing facilities to add secures spaces compliant with ICD/ICS 705 standards through DB or DBB procurement.

2. Design of new facilities with Secured Spaces compliant with ICD/ICS 705 standards through DB or DBB procurement.

3. Design of projects demonstrating experience in conducting investigations, studies, and evaluations, and providing recommendations for renovations to existing facilities containing Secured Spaces.

Firms may be considered more favorably by demonstrating:

1. Relevant Department of Defense (DoD) Project Experience - projects demonstrating relevant design experience at military installations utilizing Unified Facilities Criteria (UFCs).

2. Planning, design and construction support for relevant projects located outside the United States, its territories and processions and not under Chief of Mission (COM) Authority in accordance with Intelligence Community (IC) Tech Spec for

ICD/ICS 705.

3. Relevant experience with implementation of a radio frequency (RF) shielding for a facility with a Secured Space constructed and accredited in accordance with

ICD/ICS 705.

Submission requirements:

Provide a maximum of five (5) relevant projects with the design completed within the past ten

(10) years immediately preceding the date of issuance of this notice that best demonstrate relevancy and specialized experience of the proposed team in the areas outlined above. A relevant project is defined as a completed design of one or more of the similar types of facilities, as outlined above, containing Secured Space(s) that are accredited in accordance with ICD/ICS 705 and ready for the intended use, for which design drawings and specifications have been signed and sealed by the Registered Architect(s) and Professional Engineer(s). Sufficient information to determine the date of completion of the project must be included in the project description or the project will not be considered. If more than the maximum number of projects are submitted, the Government will only evaluate projects up to the maximum number authorized in the order submitted.

Within the maximum of five (5) relevant design projects, as defined above, firms shall demonstrate experience with planning and design services of the following:

A minimum of one (1) project shall demonstrate relevant experience with new construction of facilities with Secured Spaces through DB or DBB and shall have been constructed and accredited in accordance with ICD/ICS 705.

A minimum of one (1) project shall demonstrate relevant experience with repair and/or renovation of facilities with Secured Spaces through DB or DBB and shall have been constructed and accredited in accordance with ICD/ICS 705.

A minimum of one (1) project shall demonstrate relevant experience with interpretation and implementation of a Construction Security Plan (CSP) for a facility with a Secured Space constructed and accredited in accordance with ICD/ICS 705.

A minimum of one (1) project shall demonstrate relevant experience with planning, including site identification, of facilities with Secured Spaces through DB or DBB and shall have been constructed and accredited in accordance with ICD/ICS 705.

NOTE: A single project may satisfy more than one (1) of the above minimum requirements.

The following information for each submitted project must be included for consideration:

Date of project design completion (Month and Year) – Section F Block 22 Project identified as constructed or not constructed. If construction was completed on or before the date of issuance of this notice, then provide date of construction completion (Month and Year); otherwise, state Construction Not Completed – Section F Block 22.

Project construction value (US dollars) Section F Block 24 Project facility(s) size (SF or SM) Section F Block 24 Project facility(s) respective primary function type Section F Block 24 Project facility(s) identified as new construction or renovation Section F Block 24 Projects must state if Design Bid Build (DBB) or Design Build (DB) procurement, Section F Block 24.

Projects must not be identified by installation name, P number, or the command occupying Secured Spaces. Identify project by the Geographic Combat Command (AFRICOM, CENTCOM, EUCOM, INDOPACOM, NORTHCOM, SOUTHCOM) location where the project resides.

All projects provided in the SF330 must be completed by the actual office/branch/regional office/individual team member proposed to manage and perform work under this contract.

Projects not meeting this requirement will be excluded from consideration in the evaluation. To enable verification, firms should include the Unique Entity Identifier number along with each firm name in the SF330 Part 1, Section F, block 25, “Firm Name” Include a contract number or project identification number in block 21. Include an e-mail address and phone number for the point of contact in block 23(c). In block 24, include in the project description the contract period of performance, award contract value, current contract value, and a summary of the work performed that demonstrates relevance to specialized experience as outlined above. For projects performed as a subcontractor or a joint venture involving different partners, specifically indicate the value of the work performed as a subcontractor or by those firms proposed for this contract, and identify the specific roles and responsibilities performed as a subcontractor or by those firms on the project rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration.

NOTE: If the firm is a joint venture, projects performed by the joint venture should be submitted; however, if there are no projects performed by the joint venture, projects must be submitted for each joint venture partner, not to exceed a total of five (5) projects. Firms failing to provide projects from all joint venture partners will be considered to have not met the requirements of the criterion.

Projects shall be submitted on the SF330 at Part I, Section F and shall be completed projects.

Projects not completed will be excluded from evaluation consideration. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award, except where a single facility design spans multiple task orders/contract awards. For a single facility design spanning multiple task orders/contract awards to be considered a single project, each task order/contract award number or project identification number must be listed and the title on each action must make clear that the scope of each addresses the SAME facility design. Do not submit an IDIQ contract as an example project. Instead, list relevant task orders or stand-alone contract awards that fit within the definition above. The Government will not evaluate information provided for an IDIQ contract. Examples of project work submitted that do not conform to this requirement will not be evaluated.

All information for Criterion 1 should be submitted in the SF330, Part I, Section F. The Government WILL NOT consider information submitted in addition to Part 1, Section F in evaluation of Criterion 1.

Criterion 2- Professional Qualifications (SF330, Part I, Sections E & G):

Firms will be evaluated on professional qualifications, competence, and experience of the proposed key personnel in providing services to accomplish the tasks required under this contract, including participation in example projects as outlined in the SF330, Part 1, Section G.

In order to be eligible for award, prime firm must possess an active SECRET Facility

Clearance. Prime firms that possess an active SECRET Facility Clearance at time of submission may be considered more favorably.

Firms and personnel must be in compliance with ICD/ICS 705 requirements, including those pertaining to clearance level and citizenship. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise.

Specific disciplines that must be included in key personnel are Program Manager, Project Manager, Architect, Civil Engineer, Landscape Architect, Structural Engineer, Mechanical Engineer, Electrical Engineer, Geotechnical Engineer, Cost Engineer (Certified Cost Professional or equivalent), Interior Designer (practicing certified or registered), Fire Protection Engineer, Planner, Design Quality Control Manager (DQCM), ICD/ICS 705 requirements Subject Matter Expert (SME), Shielding Specialist, and Telecommunication Designer (with RCDD registration). Requirements for the ICD/ICS 705 Subject Matter Expert (SME) and Shielding Specialist) are as defined below. Engineers and Architects must be licensed in their respective disciplines.

The Prime Contractor’s Program Manager and the Prime Contractor’s Project Manager must be U.S. citizens and demonstrate eligibility to hold active SECRECT clearance at the time of contract award, such as an adjudicated SECRET clearance, at the time of Qualifications submission.

The Fire Protection Engineer must be a registered professional engineer who has passed the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveying (NCEES) and has relevant fire protection engineering experience.

The ICS/ICD 705 Subject Matter Expert shall be a U.S. citizen as defined by federal law and demonstrate eligibility to hold active SECRECT clearance at the time of contract award, such as an adjudicated SECRET clearance, at the time of Qualifications submission, and a minimum of 5 years direct experience supporting SCIF/SAPF-related projects. This individual must possess extensive experience in the design, construction, accreditation, and inspection of SCIFs and SAPFs in accordance with Intelligence Community physical and technical security standards;

TEMPEST and technical surveillance countermeasures; and DOD Programs and Accreditation Processes; with formal training on ICD/ICS 705, requirements for SCIFs and SAPFs and completion of Government or IC-sponsored SCIF and SAPF design/accreditation courses.

The Shielding Specialist shall be a U.S. citizen as defined by federal law and demonstrate eligibility to hold active SECRECT clearance at the time of contract award, such as an adjudicated SECRET clearance, at the time of Qualifications submission, and a minimum of 5 years direct experience supporting SCIF/SAPF-related projects. This individual is responsible for ensuring that shielded enclosures and associated systems meet required attenuation performance standards through proper design, construction oversight, inspection, and testing for DoD Programs and Accreditation Processes. This individual must possess training and knowledge of ICD/ICS 705Intelligence Community physical and technical security standards, TEMPEST and technical surveillance countermeasures, Electromagnetic theory (EMI, RFI, TEMPEST fundamentals), Shielded enclosure design, RF attenuation performance requirements across relevant frequency ranges, Grounding and bonding principles, Waveguide design, Shielded power, signal, and data penetrations, Door assemblies, Filtered power systems, Fiber and RF feedthrough assemblies, Corrosion control and long-term enclosure integrity, and Integration with physical security and acoustic requirements.

Key personnel may be considered more favorable by demonstrating:

Experience with facilities containing Secured Spaces completed in accordance with ICD / ICS 705 through planning, DB or DBB process, which are not located within the United States, its territories or possessions, and not under Chief of Mission (COM) Authority, may be considered more favorably in the evaluation.

Key personnel that are an employee of the prime A-E firm may be considered more favorably in the evaluation.

Adjudicated security clearance level of SECRET or higher for the following: Program Manager, Project Manager, ICS/ICD 705 Subject matter Expert, Shielding Specialist, Architect, Civil Engineer, Landscape Architect, Structural Engineer, Mechanical Engineer, Electrical Engineer, Geotechnical Engineer, Cost Engineer (Certified Cost Professional or equivalent), Interior Designer (practicing certified or registered), Fire Protection Engineer, Planner, Design Quality Control Manager (DQCM).

ICD/ICS 705 SME holding an adjudicated TS/SCI clearance (with appropriate compartments).

Shielding Specialist holding an adjudicated TS/SCI clearance (with appropriate compartments).

Submission Requirements:

SF330, Part I, Section E. Provide resumes for all proposed key personnel that illustrate experience in the work proposed under this contract. Resumes are limited to one single-sided

8.5 by 11-inch page and should indicate: professional registration, certification, licensure and/or accreditation in appropriate disciplines: cite recent (within the past 10 years) project-specific experience in work relevant to the services required under this contract; and indicate proposed role in this contract. Key personnel may not fulfill more than one role stated in this synopsis.

Professionally registered key personnel must include the state where registration was issued, registration number, expiration date of registration, adjudicated security clearance level (if applicable), and geographic office location for each proposed key personnel member.

Indicate participation of key personnel in example projects in the SF330, Part 1, Section G.

In order to be eligible for award, prime firm must possess an active SECRET Facility Clearance. Submit within a separate .pdf, a Security Package for verification by the NAVFAC Atlantic Security Office: a letter on Company letterhead that provides firm name, address and company Cage Code and a list of key personnel with adjudicated clearances, including Full Name, Birthdate, SSN, Phone Number, and Email Address. This list will be Controlled Unclassified Information (CUI) as it will include Personally Identifiable Information

(PII).

If a SF 254/SF 255 is submitted, it will not be reviewed or considered.

Criterion 3 - Past Performance (SF330, Part I, Section H):

Firms will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS for Criterion 1 projects and may include customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. NOTE: Past performance information for projects listed under Criterion 1 may be given greater weight.

Submission Requirements:

SUBMIT A COMPLETED CPARS EVALUATION FOR EACH PROJECT UNDER

CRITERION 1. IF A COMPLETED CPARS EVALUATION IS NOT AVAILABLE, the Past Performance Questionnaire (PPQ) (Attachment (A)) included in this notice is provided for the firm or its team members to submit to the client for each project included under Criterion 1, Specialized Experience. DO NOT SUBMIT A PPQ WHEN A COMPLETED CPARS IS

AVAILABLE.

IF A CPARS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs should be submitted with your SF330. If the firm is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, firms should complete and submit with their responses the first page of the PPQ (Attachment (A)), which will provide contract and client information for the respective project(s). Firms may submit a PPQ previously submitted under a different Notice/RFP (legible copies are acceptable) as long as it is on the same form as posted with this Synopsis. Firms should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, NAVFAC Atlantic, Code CON22, Attn: Kimberly Hall, Contract Specialist; kimberly.a.hall124.civ@us.navy.mil, prior to the response date. Firms shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A/E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation.

Firms may provide any information on problems encountered and the corrective actions taken on projects submitted under Criterion 1 Specialized Experience. Firms may also address any adverse past performance issues. Information shall not exceed four single-sided 8.5 by 11-inch pages in total.

Awards, letters of commendation, certificates of appreciation, etc. shall not be submitted and will not be considered in the evaluation.

Criterion 4 - Program Management, Capacity, and Location (SF330, Part I, Section H):

Firms will be evaluated on the firm’s ability to plan for and manage work under the contract, the capacity to accomplish the work in the required time, and on the locations of their office(s) that will be performing the work under this contract and demonstrated knowledge of the primary geographic areas in which projects could be located.

Submission Requirements:

1. Provide an organizational chart for the team and discuss the management plan for this contract and personnel roles in the organization. Describe the ability of the firm to manage, coordinate and work effectively with team members, both internal staff and consultants. Discuss the history of working relationships with team members, including joint venture partners where applicable.

2. Describe the firm’s present workload and the availability of the project team (including consultants) for the specified contract performance period. Describe the workload/availability of the key personnel during the anticipated contract performance period and the ability of the firm to provide qualified backup staffing for key personnel to ensure continuity of services. General statements of availability/capacity may be considered less favorably.

3. Provide the location of the office(s) that will be performing the work, including main offices, branch offices, and offices of team members. Evaluation of firms will include consideration of their location within the primary geographic area of the anticipated projects, primarily NAVFAC Atlantic and Pacific AORs. Provide a narrative describing the team’s knowledge of the primary geographic areas in which projects could be located.

Information shall not exceed shall be limited to two (2) single-sided 8.5 by 11-inch pages (the page limit does not include the Organizational Chart) in total.

Criterion 5 - Commitment to Small Business (SF330, Part I, Section H):

Firms will be evaluated in terms of the extent to which they have identified and committed to Small Business (SB), Small Disadvantaged Business (SDB), Women-Owned Small Business (WOSB), Historically Underutilized Business Zone Small Business (HUBZoneSB), Veteran- Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), and if applicable, Historically Black Colleges or Universities and Minority Institutions (HBCU/MI) in performance of this contract, whether as a joint venture, teaming arrangement, or subcontractor. The Government will evaluate submissions based on factors: (A) Past performance in utilization of small business concerns, and (B) Participation of small business concerns for this requirement.

All firms shall provide historical data on utilization of SB, SDB, WOSB, HUBZoneSB, VOSB, SDVOSB and HBCU/MI. In support of evaluation factor (A), Large Businesses (LBs) shall submit three (3) “final” or “most recent” Individual Subcontracting Reports (ISRs) for similar contracts of comparable size which show compliance with utilizing the various types of small business firms noted above. If ISRs are not final or most recent they will not be considered. The most recent reporting period is 30 September 2026; therefore, any ISR submitted that is not final must be from the 30 September 2026 reporting period to be considered. Failure to provide three (3) ISRs that comply with the requirements will result in a NOT MET for this criterion, unless ISRs for similar contracts of comparable size are not available. If ISRs for similar contracts of comparable size are not available, large businesses shall submit other documentation which shows their utilization of the various types of small business firms for similar contracts of comparable size. If subcontracting goals were not met, provide an explanation.

Small Businesses (SBs) shall also submit documentation which shows their utilization of the various types of small business firms for similar contracts of comparable size.

In support of Attachment (B), large businesses shall submit a draft Small Business Subcontracting Plan, in which they will be evaluated on the extent to which they identify and commit to the published Small Business Subcontracting Program. The Secretary of the Navy has assigned the Naval Facilities Engineering Systems Command goals for FY2027 in terms of percentages of total planned subcontracting dollars for utilization of small businesses.

Demonstrate the plan to meet these goals:

FY2027 FY2028 FY2029 FY2030 FY2031

SB 40% 40% 40% 40% 40%

HUBZone 3% 3% 3% 3% 3%

SDVOSB 5% 5% 5% 5% 5%

SDB 5% 5% 5% 5% 5%

WOSB 9% 9% 9% 9% 9%

If a large business firm is selected for award, a Small Business Subcontracting Plan, in accordance with FAR 19.109, FAR 19.206, FAR 19.302, DFARS 219.109, DFARS 219.206, and DFARS 219.302 will be required and incorporated into the contract award. The attached Small Business Subcontracting Plan template (Attachment (B)) shall be used by large businesses to complete the draft subcontracting plan. Firms shall submit their “draft” Small Business Subcontracting Plans utilizing this template, and ONLY this template.

A draft Small Business Subcontracting Plan is not required from small businesses; however, small businesses shall submit similar information on the extent to which they identify and commit to subcontracting to LB, SB, SDB, WOSB, HUBZoneSB, VOSB, SDVOSB, and HBCU/MI if applicable in the performance of this contract.

The Small Business size standard classification is NAICS 541310, Architectural Services, size standard $12.5M.

Criterion 6 - Volume of Work (SF330, Part 1, Section H)

Firms will be evaluated in accordance with DoD Federal Acquisition Regulation Supplement (DFARS) Procedures, Guidance and Information (PGI) 236.202-1, from data extracted from the Federal Procurement Data System (FPDS). Firms will be evaluated in terms of work previously awarded to the firm by DOD within the past twelve months with the objective of effecting an equitable distribution of contracts among qualified A&E firms including small, disadvantaged business firms, and firms that have not had prior DOD A&E contracts.

Submission Requirements:

Firms do not submit data for this factor. The Government will obtain information as described above. For joint venture (JV) submissions, the Government will obtain the data for each JV partner.

SF330 SUBMISSION REQUIREMENTS:

Architect-Engineer firms desiring to be considered for this contract must submit a completed SF330 package. The SF330 shall be typed, one sided, at least 11-point Times New Roman or larger. Part I shall not exceed sixty (60) single-sided 8.5 by 11-inch pages (the page limit does not include ISRs, certificates, PPQs, licenses, or the draft subcontracting plan, as required by the Small Business Subcontracting criterion, nor does the page limit include cover sheets, dividers, or other requested documentation (e.g., joint venture agreement, proof of AE firm registration) provided that these do not contain any substantive information submitted in response to the synopsis or intended to demonstrate the qualifications of the firm. Part I pages shall be numbered sequentially. The organizational chart may be one page single sided 11 by 17 foldout, using 11-point font or larger (font limitations do not apply to graphics, captions or tables). Please include your Unique Entity Identifier and CAGE numbers in Block 30 of the

SF330.

**In accordance with the FAR 36.202-3(d), contracts for architect-engineer services may only be awarded to firms permitted by law to practice the professions of architecture or engineering.

Firms must submit proof that they are permitted by law as required by FAR 36.202-3(d). If a firm is in a jurisdiction that requires AE firm registration, the firm must provide proof of registration. If a firm is in a jurisdiction that does not require AE firm registration, the firm must provide proof eligibility to practice (e.g., a summary explaining eligibility under the laws of that jurisdiction). Failure to submit the required proof could result in a firm’s elimination from consideration. Firms that submit SF330s that are not in compliance with DFARS 252.236-7011, Overseas Architect-Engineer Services –Restriction to United States Firms, may be eliminated from consideration.

**Firms who are offering as a joint venture should include with their submission a copy of the joint venture agreement. Failure to include the joint venture agreement may result in the firm’s elimination from further evaluation. Joint Venture Firms shall not include Naval Facilities Engineering Systems Command, Atlantic (NAVFAC) in its joint venture name.

Classified information up to Secret-level and Controlled Unclassified Information (CUI) generated and /or provided under this contract shall be safeguarded, marked as SECRET or CUI, as appropriate, and meet OPSEC requirements. The contractor shall protect and destroy all Controlled Unclassified Information (CUI) to include Privacy Act and Personal Identifiable Information (PII) IAW DODI 5200.48.

THIS IS NOT A REQUEST FOR PROPOSAL.

Except as noted otherwise, the Government will not consider information submitted beyond the page limit. Furthermore, the Government will consider information for each Criterion only in the section specified for that Criterion.

Submissions shall be via the Procurement Integrated Enterprise Environment (PIEE) Solicitation Module at https://piee.eb.mil. Submissions shall be in a format readable by Microsoft (MS) Word 2016, Adobe Acrobat, or MS Excel 2016. Electronic submissions should be no larger than 1.9 GB per file. PIEE Solicitation Vendor Access Instructions are provided below. Emailed or hand delivered submissions will not be accepted.

Firms must register for the PIEE 'Contract Administrator' role.

For step-by-step instructions, see "Vendors - Getting Access Help" at:

https://piee.eb.mil/xhtml/unauth/web/homepage/vendorGettingStartedHelp.xhtml.

Firms are further encouraged to contact the PIEE Helpdesk at 1-866-618-5988 for additional assistance. It is strongly recommended that Firms register well in advance of the submission due date, so that there is ample time to resolve potential registration issues that may arise.

Only the PIEE Solicitation Module is authorized for submissions to this synopsis – with the exception of the separate Security Package (as described under Criterion 2) which shall be submitted to the NAVFAC Atlantic Security Office Point of Contact, Robert Hernandez;

robert.hernandez3.civ@us.navy.mil.

Firms shall allow adequate time to upload files which may be slower for non-DoD users and to avoid other technical difficulties that may be encountered. Firms are also responsible for submitting files in the format specified and consistent with requirements stated elsewhere in this synopsis. Files that cannot be opened or are otherwise missing the required content may be rejected.

SF330 and Security Package shall be submitted by the date and time listed below, unless date is changed via synopsis Amendment. PIEE system will record the date and time of package submittal. The date and time of package submittal recorded in PIEE shall govern the timeliness of any submission.

It is the sole responsibility of the firm to obtain the Synopsis along with any amendments, from sam.gov.

Late responses will be handled in accordance with FAR 52.215-1. The Government point of contact is Kimberly Hall, Contract Specialist, kimberly.a.hall124.civ@us.navy.mil.

Inquiries concerning this procurement should include synopsis number and title and be forwarded via email to the point of contact. Inquiries concerning the Synopsis shall be received no later than 14 calendar days prior to the SF330 due date. Late inquiries will not be answered.

Architect-engineer firms that meet the requirements described in this announcement are invited to submit a completed SF330 and Security Package (.pdf format) in response to this synopsis.

Firms responding to this announcement by 30 DECEMBER 2026 at 2:00 PM EST will be considered.

THIS IS NOT A REQUEST FOR PROPOSAL.

File details come from the government source that posted it. Updated .