Part Numbers/ Description and QTY.

The following items are being acquired:

Item
Part #
Item Name
Qty
1
380-3-0X-P-C
VALVE GLOBE SHUT OFF,1/2"

5800 PANEL MOUNT

2
380-1-0X-P-C
VALVE, GLOBE, SHUTOFF, OSEAL 1/4" 4700 PSI PANEL MOUNT
25
3
380-4-0X-C
VALVE GLOBE SHUT OFF 3/4"
21
4
380-3-0X-C
VALVE GLOBE SHUTOFF 1/2"

5800 PSI

5
003814
SOFT GOOD KIT: CONSISTS OF: 1919 VITON U-CUP 224 TEFLON BACK-UP RING 224 VITON O-RING (90DURO)& 213 VITON O-RING (90 DURO)
5
6
003813
SOFT GOOD KIT: CONSISTS OF: 1919 VITON U-CUP 223 TEFLON BACK-UP RING 223 VITON O-RING (90 DURO)& 115 VITON O-RING (90 DUR0)
5
7
003811
1/4" SOFT GOOD KIT, VITON: CONSISTS OF: 1905 VITON

U-CUP 216 TEFLON BACK-UP RING 216 VITON O-RING & 014 VITON O-RING

8
380-3-P-SP-C
VALVE, GLOBE, SHUTOFF, 1/2, 6000 PSI NAB BODY/BONNET/GLAND NUT, SP-21 DISC, C SOFTGOODS (VITON FKM) **REPLACES PL4527C
36
9
All valves/kits must be subjected to a Packing Test with documentation as required:

With the valve open and the outlet port closed off, pressurize the valve to 6000 psig (+200/-0) with nitrogen gas for a period of FIVE minutes.

10
All valves/kits must be subjected to a Main Seat Test with documentation as required:

With the valve closed hand tight on the hand wheel, pressurize the valve in BOTH directions under the seat to 6000 psig (+200/-0) with 100% He for a period of FIVE minutes.

11
All valves/Kits. Clean valves and soft good rebuild kits IAW MIL-STD-1330 Rev D with change notice 1, and NAVSEA approved cleaning procedure UCC-946, dated 12-12-2007, per purchase order requirements.
12
Certificates of Compliance must be provided for all items.
13
All items shipped to 321 Bullfinch Road, Panama City, FL 32407

Shipping and invoicing of individual CLINS is preferred when total quantity of CLIN is ready to ship.