Part Numbers/ Description and QTY.
The following items are being acquired:
| Item |
| Part # |
| Item Name |
| Qty |
| 1 |
| 380-3-0X-P-C |
| VALVE GLOBE SHUT OFF,1/2" |
5800 PANEL MOUNT
| 2 |
| 380-1-0X-P-C |
| VALVE, GLOBE, SHUTOFF, OSEAL 1/4" 4700 PSI PANEL MOUNT |
| 25 |
| 3 |
| 380-4-0X-C |
| VALVE GLOBE SHUT OFF 3/4" |
| 21 |
| 4 |
| 380-3-0X-C |
| VALVE GLOBE SHUTOFF 1/2" |
5800 PSI
| 5 |
| 003814 |
| SOFT GOOD KIT: CONSISTS OF: 1919 VITON U-CUP 224 TEFLON BACK-UP RING 224 VITON O-RING (90DURO)& 213 VITON O-RING (90 DURO) |
| 5 |
| 6 |
| 003813 |
| SOFT GOOD KIT: CONSISTS OF: 1919 VITON U-CUP 223 TEFLON BACK-UP RING 223 VITON O-RING (90 DURO)& 115 VITON O-RING (90 DUR0) |
| 5 |
| 7 |
| 003811 |
| 1/4" SOFT GOOD KIT, VITON: CONSISTS OF: 1905 VITON |
U-CUP 216 TEFLON BACK-UP RING 216 VITON O-RING & 014 VITON O-RING
| 8 |
| 380-3-P-SP-C |
| VALVE, GLOBE, SHUTOFF, 1/2, 6000 PSI NAB BODY/BONNET/GLAND NUT, SP-21 DISC, C SOFTGOODS (VITON FKM) **REPLACES PL4527C |
| 36 |
| 9 |
| All valves/kits must be subjected to a Packing Test with documentation as required: |
With the valve open and the outlet port closed off, pressurize the valve to 6000 psig (+200/-0) with nitrogen gas for a period of FIVE minutes.
| 10 |
| All valves/kits must be subjected to a Main Seat Test with documentation as required: |
With the valve closed hand tight on the hand wheel, pressurize the valve in BOTH directions under the seat to 6000 psig (+200/-0) with 100% He for a period of FIVE minutes.
| 11 |
| Clean valves and soft good rebuild kits IAW MIL-STD-1330 Rev D with change notice 1, and NAVSEA approved cleaning procedure UCC-946, dated 12-12-2007, per purchase order requirements. |
| 12 |
| Certificates of Compliance must be provided for all items. |
| 13 |
| All items shipped to 321 Bullfinch Road, Panama City, FL 32407 |
Shipping and invoicing of individual CLINS is preferred when total quantity of CLIN is ready to ship.