BLD 7201 Floor Plan.pdf

PDF 623 KB Posted

Attached to
15-Ton Bridge Crane
Solicitation number
N4523A26Q0202
Issued by

About this file

This document is an architectural drawing set for a Controlled Industrial Facility at Naval Submarine Base Bangor in Silverdale, Washington. The drawing depicts the plan view layout of Building 7201, a 10-ton bridge crane facility (Serial Number 1466-A), prepared by the Department of the Navy Naval Facilities Engineering Command. The facility includes multiple rooms and spaces numbered from 100-125, with designated areas including a gas shelter, trailer canopy, and laydown space. Key infrastructure elements specified include electrical distribution (CRA5125), rails and girders (CRA5050), and the 10-ton bridge crane general arrangement (CRA5034). The drawing indicates specific constraints such as walls extending to the ceiling that cannot be breached by the circulating main lift, and limitations on laydown space placement within the red lines outlined in the facility.

The document is identified as Construction Contract Number 74-C-5026 and was prepared by SUBASE PW Engineering with satisfaction approval from BOSC SYS/Maintenance Engineering and Johnson Controls. The drawing is marked as Sheet 1 of 1 with a scale of none and no vendor drawings required. The facility plan illustrates a controlled industrial environment designed to accommodate submarine base operations with integrated structural, mechanical, and electrical systems supporting the primary crane functionality within the building envelope.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRAILER CANOPY

GAS SHELTER

rnJ um

I125 I

[ill [IT]

Do

Im] [ill] ~

!117A I ill[]

[If[]

CONTROLLED INDUSTRIAL FACILITY

PLAN VIEW

NORTH

[ill [NJ

1109 1

1107 I

UP

ELECTRICAL DISTRIBUTION ALL CRA5125

2 RAILS & GIRDERS 114 CRA5050

1 10 TON BRIDGE CRANE GENERAL ARRANG. 1466- A 114 CRA5034

ITEM DESCRIPTION

J~HNSON

CONTR~LS

• lPlllm A\Jial~ ~

Navel Submarine Base Bangor Silverdale, Wa. 98315

SATISFACTORY TO

BOSC SYS/MAINTENANCE ENGRG DATE

SER. NO ROOM NO. DWG NO

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

NAVAL SUBM ARIN E BASE BANGOR

SILVERDALE, WASHINGTON

CRANE LOCATION

CON TROLLED INDUSTRIAL FACILITY

10 TON SER. N0 .1466-A BLOG. 7201

If) (J'I

' If) (\J

' t--w I

I

SUBASE PW ENGINEERING DATE

CODE !DENT.NO. S IZE DRAWING NO.

C CRA5033

REV. ~

80091

CUSTOMER DATE

SCALE NONE

CONSTR. CONTR. NO. 74- C- 5026

VENDOR DWG. NONE SHEET 1 OF 1

w (I')

P::i ::i (.I)

Appendix A

For Reference Only 2 ps198312 Callout Roll-up truck access door is along this section (not shown) ps198312 Callout Walls do NOT go to ceiling. Can be reached over with articulating man-lift.

ps198312 Line ps198312 Line ps198312 Polygonal Line ps198312 Text Box Laydown space likely to be within red lines, but not occupy entirety of area outlined in red.

ps198312 Callout All of these walls go to the ceiling - separates office spaces from industrial space.

File details come from the government source that posted it. Updated .