C03.0 N4523A24R1063 YT-808 Class Ship Alteration YT-0110D Government Responses to RFC 001-006.pdf

PDF 435 KB Posted

Attached to
YT-808 Class Ship Alteration YT-0110D
Solicitation number
N4523A24R1063
Issued by

About this file

This document contains the Government's responses to Requests for Clarification (RFC) 001-006 related to the YT-808 Class Ship Alteration YT-0110D contract opportunity. Key details include:

The Government cannot provide the requested photographs, but has attached the operations and maintenance manual for the engines. The engines are raw water cooled, and there are no jacking pads - new mounts will need to be fabricated and are not preloaded.

The related federal contract opportunity is a Firm-Fixed-Price contract for the Alteration of five YT-808 Class Tugs. The work will be performed at a contractor's facility located in the Puget Sound, WA region and includes coordination of vessel delivery, replacement of the main engine mounts, and custody transfer. This is a 100% Small Business set-aside under NAICS code 336611 with a size standard of 1,300 employees. The period of performance is from July 16, 2024 through December 18, 2024.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Government Responses to RFC 001- 006 N4523A24R1063 YT-808 Class Ship Alteration YT-0110D

001) Question:

I would like photos of the following:

1. Top and side of the engine mount

2. Bottom of the engine mount, under the flange, both sides as dictated by the web stringer

3. Left, right, front, and back alongside the engine with the grating in the photo

4. Top of the engine by the exhaust(AFT)

5. Top of the engine by the electrical panel(wire bundle hanging down in cable way)(FWD)

6. Front lower side of the engine(connection to the fire-pump)

7. Back lower side of the engine (connection to Marine Control Drive(MCD)

Response:

The Government cannot provide pictures.

002) Question:

Can the customer provide the tech manual for this engine?

See attached (M0065584EN-US) for the operations and maintenance manual.

003) Question:

Can you provide pictures of:

a. Intermediate shafts

b. Motor mounts

c. Cooling water connections

The Government cannot provide pictures.

004) Question:

Are the engines keel cooled or raw water cooled?

The engines are raw water cooled.

005) Question:

Are there Jacking Pads or would they need to be fabricated?

There are no jacking pads.

006) Question:

Are the new mounts preloaded?

The new mounts are not preloaded as they are solid mounts.

File details come from the government source that posted it. Updated .