C03.0 Government Response to RFC 002 N4523A22R1060 15MWB9207.pdf
PDF 173 KB Posted
- Attached to
- Maintenance on 15 Meter Work Boat 9207
- Solicitation number
- N4523A22R1060
About this file
This document contains the government's response to a contractor's request for clarification on a solicitation for maintenance services on a 15-meter work boat. The solicitation seeks a firm-fixed price contract to perform maintenance, repair, and preservation work on a 50-foot steel hull work boat built in 1994. Services include cleaning, blasting, and preserving the hull; replacing zinc anodes and non-skid deck coating; inspecting and testing tanks and voids; repairing propulsion and steering systems; and arranging delivery of the vessel. The period of performance is from May 10, 2022 to July 26, 2022. The solicitation is set aside for small businesses only under NAICS code 336611 with a size standard of 1,250 employees. The issuing agency is the Department of the Navy Naval Supply Systems Command.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR SPECIFICATION CLARIFICATION
DATE OF REQUEST: 1-26-22 QUESTION NO: 002
REQUIREMENT: Maintenance and repair of
15MWB9207
REQUISITION NO.: N4523A22R1060
ITEM NO: N/A
TITLE: Vessel Delivery/Pickup
ISSUING OFFICE POC (CODE 431):
Nathan Grimm Nathan.c.grimm@navy.mil Chris Campbell Chris.campell@navy.mil
PARA. NO: PAGE NO: CONTRACTOR:
PLANNER’S NAME: 3 ATTACH. NO: CONTRACTOR POC & PHONE:
CONTRACTOR QUESTION:
3.2.2.2: Page 26: What are the dimensions of the “D” rubber. Is there a manufacturer and part number available?
3.2.8: Page 29: What is the estimated quantity of preservative in each of the skegs?
3.2.8: Page 29: What is the liquid that is currently in skegs for disposal
3.2.9: Page 29: Clarify “ remove existing and install new” sea chest flanges. Is this in reference to the flanges welded into the steel sea chest (part of vessel), valves or associated plumbing
3.2.9: Page 29: If the above is to replace the valves, are there requirements on valve selection? Composition, manufacturer etc
3.7…Page 38: What is the wrench size needed for the castle nut on each side of prop shaft?
3.8.2.2: Page 40: Inspections for wear and defects: Does this include disassembly of hydraulic ram(s) to measure cylinder bore for wear, seals etc for wear.
DO NOT WRITE BELOW THIS LINE
SPEC CHG: N DWG/REF CHG. N RQMTS CHG: N MAT'L CHG: N
TECHNICAL REVIEW: Carney, Sean R C/101.11 SBS SERIAL NO: 15MWB9207 001 DC http://3.2.2.2/ http://3.8.2.2/
Responses.
3.2.2.2; Dimensions provided under item #1 of reference shown in paragraph 3.2.2.2
3.2.8; Fluid was filled and drained during previous availability as required and shown in paragraph, estimate quantity of residual fluid remaining in skeg to be drained prior to air test not to exceed 10 gallons.
3.2.8; Currently preserved with rust preservative meeting the same specifications shown in paragraph 3.2.8.3
3.2.9; Clarification for paragraph 3.2.9 already provided in paragraph 3.2.9.1 and 3.2.9.2
3.2.9; Answered in previous, read paragraph 3.2.9.1 and 3.2.9.2
3.7; castle nut inner dimensions for threading show in Reference Drawing 6. Castle nut exterior dimensions for a wrench are not available as the vessel is waterborne. Template from existing vessel conditions after blocking.
3.8.2.2; Paragraph specifically states for exposed parts. Exposed parts do not include internals.
ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING OFFICE POC NO
LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST FOR PROPOSAL.
File details come from the government source that posted it. Updated .