This Technical Capability/Contractor Responsibility Certification Statement is a solicitation for three high-pressure air compressor rentals (Solicitation Number: N4215825Q0071) for ship service applications, including breathing air. The document details extensive technical requirements for the compressed air systems, which must supply at least 85 SCFM of air at 5,000 psig, be certified for breathing air quality, and meet specific operational specifications. Key requirements include electrical compatibility (460-Volt, 3-phase, 60HZ), ability to operate 24/7 without constant monitoring, automatic controls, CO monitoring, weather resistance, portability, compliance with OSHA and ASME regulations, and specific construction and marking standards. Vendors must complete the form by initialing each specification to confirm their equipment meets the requirements, with the goal of renting self-contained compressed air systems capable of supplying high-pressure air for maritime applications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNICAL CAPABILITY/CONTRACTOR / RESPONSIBLITY CERTIFICATION

STATEMENT

Vendor shall certify for equipment being quoted that his product meets each capability listed below by initialing at the bottom. In order to be considered for award, this must be completed and submitted with your quote.

PURPOSE OF REQUEST: SERVICE RENTAL FROM VENDOR TO PROVIDE: Three

(3) H. P. AIR COMPRESSOR RENTAL (Self-contained compressed air system used to supply high-pressure air for ship service applications including breathing air. The compressed air system will include a compressor, air dryer, closed loop cooling system and other components)

Technical Capabilities Statement – Solicitation Number: N4215825Q0071 Manufacturer Name:

Part #:

Model#:

EQUIPMENT REQUIREMENTS

Shall be provided with the following capabilities, features, and specifications:

YES NO Not Applicable

The compressed air system shall supply a Free Air Delivery (FAD) of at least 85 SCFM of air at a pressure of 5,000 psig

The compressed air supplied by the compressed air system shall be certified for breathing air quality per paragraph 15008 of OPNAVINST 5100.23, latest rev, or the applicable OSHA regulations for compressed breathing air supply

The air quality specifications for breathing air and ship service IAW Statement of Work, Section 3.1.1.a-h

The compressed air system shall have controls which start and stop the compressor when pressure set points are met at the compressor discharge. The set points shall be adjustable by the customer. The set points shall have a range of adjustability between 3000 and 5000 psi.

The compressed air system shall be electrically powered, suitable for a 460-Volt, 3-phase, 60HZ, and 100 Amps max power supply

Must be capable of producing breathable quality, compressed air WITHOUT any additional utilities such as a water supply

Capable of running 24 hours/day, 7 days/week.

Shall be self-regulating with fully automatic controls, alarms, and indicators so that the compressor package requires monitoring no more than once every 24 hours by compressor operators after start-up

System shall include the accessory equipment and any other equipment necessary to meet the requirements IAW Statement of Work, Section 3.2.4.a-e

Each compressed air system will have a CO Monitor installed to alarm and secure the compressor upon a high CO reading of 10 PPM.

All exposed components must be weather resistant. All components must meet or exceed NEMA Type 4 for outdoor use.

CONSTRUCTION REQUIREMENTS

Compressed air system shall be wholly contained in one container or skid (containers shall be constructed to be portable, capable of being both transported by forklift and crane)

Shall have louvers to prevent water intrusion during rain while system is in operation (if containers are utilized)

The installed compressed air system shall together occupy a volume with dimensions which do not exceed 8’-0” wide by 20’-0” long by 10’- 0” high (including the compressor and all accessory equipment)

Shall comply with the applicable OSHA regulations Shall comply with the applicable ASME Boiler and Pressure Vessel Code

Shall be equipped with a flexible hose at least twelve (12) feet in length to permit users the option of directing condensate into a user-supplied containment drum

Shall include drip pans or trays to capture and contain fluid leaks Relief valves shall have intact wire seals on their adjustment caps and shall bear tags indicating the set point, testing activity and test date

Pressure gauges shall be in calibration to manufacturer standards and shall bear labels showing calibration which will not expire during the contract period

Power cable end fittings are lugged and color coded to indicate proper phasing

The outlet from the compressed air system shall have a cut-out valve for isolation purposes and the end fitting of the compressed air outlet will be ½” male 6000# CPV Union End fitting.

Discharge piping will have a 90o fitting in order to eliminate the kick hazard.

Inlet air filter will be Polymer in lieu of paper filters.

The equipment shall be outfitted with suitable attachments for overhead lifting.

Each lifting attachment shall be capable of supporting one half the gross weight of the equipment with a design factor of five to one based on ultimate strength

Each lifting attachment shall be designed to accept a standard anchor shackle (Federal Specification RR-C-271D, type IVA) which is capable of supporting one half the gross weight of the equipment

Lifting attachments shall be such that the shackles are not side loaded.

Each lifting attachment shall be conspicuously marked in a contrasting color “Lift Here”

The equipment shall be marked in a prominent location with the gross weight. Marking shall be upper case letters of a contrasting color, with a minimum height of 1”. Marking shall include the units (i.e. “pounds”, “long tons”, etc.)

The equipment shall be provided with a lifting sketch / rigging diagram The lifting sketch shall detail any specific requirements and / or configurations that must be met prior to lifting

REQUIRED MARKINGS

System shall have the (1) air capacity, (2) maximum supply pressure and (3) the electric motor horsepower and RPM rating stamped on a metal plate attached to the equipment

System shall have the manufacturer's name and the manufacturer's serial number stamped on a metal plate attached to the component

In order to be considered technically acceptable, this form must be completed in its entirety.

Vendor shall certify that his/ her product meets or does not meet each specification listed above by initialing in the applicable YES or NO box beside each specification. ____________ (initials)