6871159_DrawingsAsOne_(4of4).pdf
PDF 2 MB Posted
- Attached to
- B-4257-Provide Utilities for Communication Tower Federal contract opportunity
- Solicitation number
- N40085-6871159
About this file
DrawingsAsOne (4of4)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0001.pdf | ||
| 6871159_DrawingsAsOne_(3of4).pdf | ||
| 6871159_DrawingsAsOne_(2of4).pdf | ||
| 6871159_DrawingsAsOne_(1of4).pdf | ||
| 6871159_SpecsAsOne.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P R
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
09/13/19
EL
EC
TR
IC
A L
D
ET
A
IL
S
GR
GR
GR
GRGR
GR
GR
GR GR
GR
GR
GR
GRGR
GR GR
GRGRGRGRGR
GR
GR
GR
GR
GR
GR
GR
P R
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
09/13/19
XXX XXX XXX
12798255
EL
EC
TR
IC
A L
D
ET
A
IL
S
AS NOTED
E-502
DUCTBANK
CONCRETE ENCASEMENT
TRENCH DETAIL (GRASS AREA)
NO SCALE
NO SCALE
12" X 12" X 24" DEEP
HANDHOLE SIZING
PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR "TELEPHONE" FOR TELEPHONE
PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
PROVIDE STAINLESS STEEL BOLTS AND INSERTS.
10" x 10" AREA.
COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A
REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.
HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS
5.
4.
3.
2.
HANDHOLES, OR AS INDICATED.
REQUIRED
BOX WHEN
SECTIONAL
1.
HANDHOLE REQUIREMENTS
TYPE
CRUSHED ROCK
6"
EARTH
COMPACTED
PULL SLOT
SURFACE
RESISTANT
SKID
LABEL
HEX BOLT AND
WASHER
STAINLESS STEEL
COVER
BOX AND
AROUND BOX
6"
CONCRETE RING 10"
6"
UG-6JUNE 2002
(COMPOSITE/FIBERGLASS) TYPES 5, 6, 7, 8 & 9
STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC)
SKETCH DATE STYLE
ATS PROVIDED WITH ELMR. REFER TO SHEET E-503 FOR SPECIFICATIONS
AND DETAILS.
GENERATOR PROVIDED WITH ELMR. REFER TO SHEET E-503 FOR
SPECIFICATIONS AND DETAILS.
PANELBOARD PROVIDED WITH ELMR. REFER TO SHEET E-503 FOR
SPECIFICATIONS AND DETAILS.
#4 GND TO CONCRETE ENCASED ELECTRODE AT TOWER GUY CONCRETE
FOUNDATION, TYP OF (3). REFER TO CIVIL DRAWINGS FOR LOCATIONS AND
STRUCTURAL DRAWINGS FOR DETAILS. PROVIDE AN ADDITIONAL GROUND
ROD AT EACH GUY FOUNDATION WITH #4 GND CONNECTED TO GUY
FOUNDATION CONCRETE ENCASED ELECTRODE. PROVIDE #4 GND TO
CONNECT TOWER GUY TO CONCRETE ENCASED ELECTRODE.
#4 GND TO CONTROL TOWER GROUND
#4 GND TO GROUNDING RING
#4 GND TO CONCRETE ENCASED ELECTRODE
NOTES THIS SHEET
EXISTING OVERHEAD PRIMARY,
7.2KV
EXISTING PRIMARY
POLE
FUSED CUT-OUT FU @ 50A
50KVA, 7.2KV - 120/240V, 1Ø, 3W
POLE MOUNTED TRANSFORMER
UE
PANEL
COMM HUT
200A MCB
240/120V 1Ø, 3W
G
UE
UE
POWER RISER DIAGRAM
NO SCALE
Ø N
GND
G
N
L N G
NG
PREMISES
ON-SITE
GENERATOR
EGC
GEN BKR
BLDG LOAD
EGC
EGC
ATS-3P
1-PHASE,
3 WIRE SERVICE
GROUND RISER DIAGRAM
NO SCALE
N
TO GROUND RING CONDUCTOR
TO CONTROL TOWER GROUND SERVICE
EQUIPMENT
SERVICE EQUIPMENT
BREAKER
UTILITY SUPPLY
TRANSFORMER
SOLIDLY
GROUNDED
SYSTEM
ENLARGED GROUND RING PLAN
1/2" = 1'-0"
NOTES:
1. A GROUND ROD MUST BE PROVIDED AT EACH FENCE POST. GROUND ROD SHALL BE
CONNECTED TO GROUND RING AND SHALL BE BONDED TO FENCE POST.
2. GROUND RING SHALL BE BONDED TO GROUNDING SYSTEM AT SERVICE ENTRANCE
EQUIPMENT. REFER TO GROUND RISER DIAGRAM THIS SHEET.
3. ALL PIECES OF THE ICE BRIDGE SHALL BE CONNECTED TO THE GROUND RING. PROVIDE
GROUND JUMPERS AS REQUIRED TO ENSURE ALL PIECES ARE INTERCONNECTED.
DUCTBANK AS INDICATED. REFER TO DUCTBANK
DETAIL THIS SHEET FOR DETAILS.
COMPACTED BACKFILL. SEE SPECIFICATION 32 11 16.16
FOR REQUIREMENTS.
4" DETECTABLE WARNING TAPE, YELLOW
SIZE AND QUANTITY AS
INDICATED
#12AWG COPPER SOLID THW
TRACER WIRE
12" MINIMUM
FINISH GRADETRENCH WIDTH
3" 3" 3"
3"
3"
2"C, PVC, TYPE "EB" (POWER)
6"
" M
IN
IM
UM
0A
-2 P
N G
TO GUY FOUNDATION
GROUNDING ELECTRODE
#8
3 #3/0, 1 #6 GND - 1-1/2"C
1"C WITH CONTROL CIRCUITING.
COORDINATE CONTROL CIRCUITING WITH
GENERATOR AND ATS MANUFACTURER.
3 #3/0, 1 #6 GND - 1-1/2"C
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
09/13/19
EL
M
R A
N D
A N
TE
N
N A
N O
TE
S
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
O
VE
R A
LL
T
EL
EC
O M
M . S
IT
E
PL
A
N , G
EN
ER
A L
N O
TE
S
L
EG
EN
D
09/13/19
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
TE
LE
C O
M M
U N
IC
A
TI
O
N S
SI
TE
P
LA
N
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
TE
LE
C O
M M
U N
IC
A
TI
O
N S
SI
TE
P
LA
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
TE
LE
C O
M M
U N
IC
A
TI
O
N S
SI
TE
P
LA
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
TE
LE
C O
M M
U N
IC
A
TI
O
N S
SI
TE
P
LA
O V
ID
E
U
TI
LI
TI
E S
F O
R C
O M
M U
N
IC
A
TI
O N
T O
W E
R B
TE
LE
C O
M M
U N
IC
A
TI
O
N S
SI
TE
D
ET
A
IL
S
| TITLE |
| G-001 |
| CIVIL |
| C-101 |
| CD101 |
| CD102 |
| CD103 |
| CD104 |
| CS101 |
| CS102 |
| CS501 |
| CS502 |
| CS503 |
| CS504 |
| STRUCTURAL |
| S-001 |
| S-501 |
| 19051_Electrical_Combined |
| E-101 OVERAL ELECTRICAL SITE PLAN, GENERAL NOTES & LEGEND |
| E-102 ELECTRICAL SITE PLAN |
| E-501 ELECTRICAL DETAILS |
| E-502 ELECTRICAL DETAILS |
| E-503 ELMR AND ANTENNA NOTES |
| 19051_Telecommunications_Combined |
| T-101 OVERALL TELECOMMUNICATIONS SITE PLAN, GENERAL NOTES & LEGEND |
| T-102 TELECOMMUNICATIONS SITE PLAN |
| T-103 TELECOMMUNICATIONS SITE PLAN |
| T-104 TELECOMMUNICATIONS SITE PLAN |
| T-105 TELECOMMUNICATIONS SITE PLAN |
| T-501 TELECOMMUNICATIONS SITE DETAILS |
File details come from the government source that posted it.