N4008521B2505 Lead Survey Report.pdf
PDF 40 MB Posted
- Attached to
- IR Demo Package A - Camp Johnson Federal contract opportunity
- Solicitation number
- N4008521B2505
About this file
This document provides details on a federal solicitation for demolition services. The solicitation number is N4008521B2505 and is for the demolition of various buildings according to the plans and specifications at Camp Johnson. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for IR Demo Package A. Responses to the solicitation are due based on the requirements in the solicitation documentation. The solicitation seeks demolition services and follows standard federal contracting guidelines.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N4008521B2505 Amendment08.pdf | ||
| N4008521B2505 Amendment07.pdf | ||
| EMD Decision Memorandum.pdf | ||
| N4008521B2505 Amendment06.pdf | ||
| N4008521B2505 Amendment05.pdf | ||
| Amended Section 02 82 16 Removal of Asbestos Materials.pdf | ||
| N4008521B2505 Amendment04.pdf | ||
| N4008521B2505 Amendment03.pdf | ||
| N4008521B2505 Amendment02.pdf | ||
| Contractor_Environmental_Guide.pdf | ||
| N4008521B2505 Amendment01.pdf | ||
| N4008521B2505 Solicitation Demo Package A.pdf | ||
| N4008521B2505 Asbestos Survey Report.pdf | ||
| N4008521B2505 Specs.pdf | ||
| N4008521B2505 Dwgs.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lead Paint Survey FY20 Infrastructure Reset Demo Buildings
Marine Corps Base Camp Lejeune Project # 20-0001
Report Prepared By:
Christopher B. Walker
The Walker Group Architecture, Inc September 11, 2020
WGA Project No. – 2001.IR20
Project Information
The Walker Group Architecture, Inc. was contracted by Camp Lejeune to conduct an lead sampling survey for Buildings/Structures : M120, M151A, M151B, M151C, M151D, M200, M201, M205, M206, M207, M208, M209, M210, M211, M212, M212A, M213, M214, M215, M216, M217, M218, M219, M220, M221, M222, M223, M224, M225, M226, M227, M228, M229, M231, M232, M233, M234, M235, M236, M237, M301, M302, M314, M319, M419, SM156. M110 was contracted for a survey however, the buildings or structures did not contain any suspect materials to sample after site investigation. Building M103 was also contracted for demolition and has previously been inspected for Lead and Asbestos by WGA consultant Precision Environmental. (See appendix B for survey). The building was reassessed by WGA and no additional materials/construction have taken place since the previous inspection. The specified buildings or structures are slated for demolition on board Marine Corps Base Camp Lejeune. The survey was conducted to determine if building components were coated with lead-based paint.
Scope of Services
A. The survey was performed on 04/20/20, 04/21/20, 04/22/20, 04/23/20, 04/26/20, by Christopher B. Walker (NC Accredited Lead Inspector #110239 expires March 31, 2021. Samples were collected from areas defined by the scope of work.
Findings
A. The Walker Group Architecture collected paint chip samples from each surface visibly coated with a different color of paint and delivered them to EMSL Analytical, Inc. (AIHA ELLAP lab code no. 102564) for analysis for lead content by Flame AAS (SW 846 3050B*/7420) in accordance with EPA 3050B/Modified/7000B. OSHA 29 CFR
1926.62 defines any detectable level of lead in paint a concern when renovations/demolitions will impact lead coated surfaces.
B. The detection limit is determined by weight of the sample, which is typically 0.01%.
See attached Lab Results for additional information.
Building M120
Building Description and Findings (Inspected 08-27-20)
Building M120 is an abandoned office building. The exterior consists of vinyl siding over wood framing and the roof is wood framed. Interior walls are wood with gypsum board and the floor is vct, concrete, and carpet.
Laboratory Results
Suspect Material Sampled Location Condition Concentration
% by Weight Cream Gypsum Board Exterior Intact <0.0080% Gray Concrete Floor Exterior Intact 0.022% Cream Interior Wood Trim Interior Walls Intact <0.0080% Black Concrete Column Base Interior Trim Intact 0.31%
Based on the sample analysis, the following coatings should be considered Lead Based Paint.
Gray Concrete Floor Black Concrete Column Base
Building M151A
Building Description and Findings (Inspected 02-17-18)
Building M151A is an Academic Instruction trailer. The building consists of a pre-fabricated metal building structure with exterior metal panels at the walls and roof. Interior walls are gypsum board and the ceilings are textured gypsum board ceilings. (2) samples were taken for analysis.
Interior white wood door system Interior Walls Intact <0.011%
Based on the sample analysis, none of the coatings should be considered Lead Based Paint.
Building M151B
Building M151B is an Administrative office trailer. The building consists of a pre-engineered
Interior white wood door system Interior Walls Intact <0.016%
Building M151C
Building M151C is an Administrative office trailer. The building consists of a pre-engineered
Interior white wood door system Interior Walls Intact <0.0081%
Building M151D
Building M151D is an Administrative office trailer. The building consists of a pre-engineered
Interior white wood door system Interior Walls Intact <0.0080%
Building M200
Building Description and Findings (Inspected 04-10-19)
Building M200 is an abandoned office building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the roof is wood framed with asphalt shingles.
Cream textured Wall Exterior Intact 0.22% Cream CMU Wall Interior Fair 0.34% White Fiber Board Ceiling Interior Ceiling Intact 6.2% White Wood Door System Interior Intact 1.0% Black CMU Interior Intact 0.018% Gray CMU Interior Fair 7.9% Red Wood Floor Interior Floor Fair <0.0080% White Wood Fascia Exterior Fair 16%
Cream textured Wall Cream CMU Wall White Fiber Board Ceiling White Wood Door System
Black CMU Gray CMU White Wood Fascia
Building M201
Building Description and Findings (Inspected 04-16-19)
Building M201 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.059% Cream Gypsum Board Interior Fair 0.012% Blue Gypsum Board Interior Intact <0.0091% Red Gypsum Board Interior Intact <0.0080% Cream Metal Door System Exterior Intact 0.0095% Cream Wood Trim Interior Fair 0.016 Cream Interior Concrete Column Interior Fair 2.1% Cream CMU Interior Fair 2.3%
Cream Textured Wall Cream Gypsum Board
Cream Metal Door System Cream Wood Trim Cream Interior Concrete Column Cream CMU
Building M205
Building M205 is an abandoned toilet room/shower facility. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the roof is wood framed with asphalt shingles.
Cream Textured Wall Exterior Intact 0.012% Cream CMU Interior Intact <0.0091% White Wood Trim Interior Intact <0.022% Cream Metal Door Frames Exterior Intact <0.024% White Gypsum Board Interior Fair <0.0080% White Wood Siding Exterior Fair 6.0%
White Wood Siding
Building M206
Building M206 is an abandoned toilet room/shower facility. The building exterior is
Cream Textured Wall Exterior Intact 0.021% Cream CMU Interior Intact 0.23% White Wood Trim Interior Intact <0.013% Cream Metal Door Frames Exterior Intact <0.014%
White Wood Siding Exterior Fair 7.4%
Building M207
Building M207 is an abandoned toilet room/shower facility. The building exterior is
Cream Textured Wall Exterior Intact 0.017% Cream CMU Interior Intact 0.78% White Wood Trim Interior Intact <0.015% Cream Metal Door Frames Exterior Intact <0.013%
Exterior White Wood Trim Exterior Fair 19%
Cream Textured Wall
Exterior White Wood Trim
Building M208
Building M208 is an abandoned toilet room/shower facility. The building exterior is
Cream Textured Wall Exterior Intact 0.017% Cream CMU Interior Intact 0.78% White Wood Trim Interior Intact <0.015% White Metal Door System Exterior Intact <0.013% Cream Gypsum Board Interior Fair <0.0080% White Wood Siding Exterior Fair 19%
Building M209
Building M209 is an abandoned toilet room/shower facility. The building exterior is
Cream Textured Wall Exterior Intact 0.010% White Under Canopy Support Exterior Intact 0.23% White Gypsum Board Interior Intact <0.25% Cream CMU Interior Intact <0.64% White Wood Trim Interior Fair <0.0080% Cream Metal Door Frames Exterior Fair <0.0080%
White Under Canopy Support
Building M210
Building M210 is an abandoned toilet room/shower facility. The building exterior is
Cream Textured Wall Exterior Intact 0.014% Cream CMU Interior Intact <0.23% White Wood Trim Interior Intact <0.25% Cream Metal Door Frames Exterior Intact <0.64%
White Wood Siding Exterior Fair 13%
Building M211
Building M211 is an abandoned storage building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the roof is wood framed with asphalt shingles.
Cream Textured Wall Exterior Intact 0.010% Cream Wood Column Interior Intact 0.23% Cream CMU Interior Intact 0.25% White Fiber Board Interior Intact 0.64% White Metal Door System Exterior Fair <0.0080%
Cream Wood Column
White Fiber Board
Building M212
Building M212 is an abandoned storage building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board and the
Cream Textured Wall Exterior Intact 0.41% Green CMU Interior Intact 0.064% White CMU Interior Intact 0.34% White Fiber Board Interior Intact 0.011% White Interior Wood Trim Interior Fair 0.32%
Green CMU White CMU White Fiber Board White Interior Wood Trim
Building M212A
Building Description and Findings (Inspected 05-02-19)
Building M212A is an abandoned office building. The building exterior is a temporary trailer building. Interior partitions are wood framed with gypsum board and the roof is wood framed with a pvc membrane.
Black Gypsum Board Interior Intact <0.81% Black Interior Wood Door System Interior Intact <1.1%
Based on the sample analysis, none of the coatings were found to contain Lead Based
Building M213
Building Description and Findings (Inspected 05-02-19)
Building M213 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.42% Cream CMU Interior Intact 0.014% White Gypsum Board Interior Intact <0.0080% White Wood Trim Interior Intact <0.0080% White Metal Door System Exterior Intact <0.0080%
Cream Interior CMU
Building M214
Building M214 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.41% Cream Wood Column Interior Intact <0.0080% Cream CMU Interior Intact 0.34% White Fiber Board Interior Intact 0.011% White Wood Door System Interior Intact 1.4% Black CMU Interior Fair 0.061%
Cream Textured Wall Cream CMU White Fiber Board
Black CMU
Building M215
Building M215 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.035% Cream CMU Interior Intact 6.4% Cream Fiber Board Interior Intact 0.13% Cream Gypsum Board Interior Intact <0.0080% White Wood Trim Interior Fair <0.015% White Wood Door System Interior Intact 0.58% Black CMU Base Interior Intact 0.30% Gray Metal Pipe System Interior Intact 0.23%
Cream Textured Wall Cream CMU Cream Fiber Board White Wood Door System Black CMU Base Gray Metal Pipe System
Building M216
Building M216 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact <0.0080% Cream CMU Interior Intact 0.16% Cream Fiber Board Interior Intact 9.0% Cream Gypsum Board Interior Intact <0.0080% White Wood Trim Interior Fair <0.014% White Wood Door System Interior Intact 1.4%
Cream CMU Cream Fiber Board
Building M217
Building M217 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact <0.41% Cream CMU Interior Intact 0.064% Cream Fiber Board Interior Intact 0.34% Cream Gypsum Board Interior Intact 0.014% White Wood Trim Interior Fair <0.32% White Wood Door System Interior Intact 0.080%
Cream CMU Cream Fiber Board
Building M218
Building M218 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact <0.41% White Gypsum Board Ceiling Interior Intact <0.064% White Metal Door System Interior Intact <0.34% Cream Gypsum Board Interior Intact <0.014% White Wood Trim Interior Fair <0.32% White Wood Door System Interior Intact <0.080%
Based on the sample analysis none of following coatings should be considered Lead Based Paint.
Building M219
Building M219 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact <0.41% White Gypsum Board Ceiling Interior Intact <0.064% White Metal Door System Interior Intact <0.34% Cream Gypsum Board Interior Intact <0.014% White Wood Trim Interior Fair <0.32% White Wood Door System Interior Intact <0.080% White Wood Canopy Exterior Intact 1.2%
White Wood Canopy
Building M220
Building M220 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.28% Cream CMU Interior Fair 0.36% White Gypsum Board Interior Intact 0.34% White Metal Door System Interior Intact 0.014% Red Gypsum Board Interior Intact 0.32% White Wood Trim Interior Fair 0.080%
Building M221
Building M221 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.062% Cream Gypsum Board Interior Intact 0.36% White Gypsum Board Interior Intact 0.34% Cream Metal Door System Interior Intact 0.014% Cream Wood Trim Interior Fair 0.32% White Wood Trim Exterior Fair 0.080%
Building M222
Building M222 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.025% Cream Gypsum Board Interior Intact 0.36% White Gypsum Board Interior Intact 0.34% Cream Metal Door System Interior Intact 0.014%
Building M223
Building M223 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.022% Cream Gypsum Board Interior Intact 0.36% White Gypsum Board Interior Intact 0.34% Cream Metal Door System Interior Intact 0.0080%
Cream Metal Door System
Building M224
Building M224 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact <0.0080% Cream Gypsum Board Interior Intact <0.0080% White Gypsum Board Interior Intact <0.0080% Cream Metal Door System Interior Intact <0.0080% Cream Wood Trim Interior Fair <0.0080%
Based on the sample analysis none of following coatings should be considered Lead Based Paint.
Building M225
Building M225 is an Academic Instruction building. The building exterior is stucco with brick framed windows/doors. The roof consists of asphalt shingles. The interior walls are gypsum board with gypsum board ceilings. (12) samples were taken for analysis.
% by Weight Exterior cream texture, CMU Exterior Walls Fair <0.0082% Exterior white metal door Exterior Walls Intact <0.018% Interior cream Gypsum board Interior Walls Intact <0.0080% Interior white Gypsum board Interior Walls Intact <0.0090% Interior black wood base Interior Walls Intact <0.019% Interior cream metal door Interior Walls Intact <0.0018%
Building M226
Building M226 is an Academic Instruction building. The building exterior is stucco with brick
% by Weight Exterior cream texture, CMU Exterior Walls Fair 0.019% Exterior white metal door Exterior Walls Intact <0.0087% Interior cream Gypsum board Interior Walls Intact <0.0080% Interior white Gypsum board Interior Walls Intact <0.0084% Interior black wood base Interior Walls Intact <0.020% Interior cream metal door Interior Walls Intact <0.0082%
Exterior cream texture, CMU
Building M227
Building M227 is an Academic Instruction building. The building exterior is stucco with brick board with gypsum board ceilings. (14) samples were taken for analysis.
% by Weight Exterior cream texture, CMU Exterior Walls Fair 0.0083% Exterior white metal door Exterior Walls Intact <0.013% Interior cream Gypsum board Interior Walls Intact <0.016% Interior white Gypsum board Interior Walls Intact <0.010% Interior black wood base Interior Walls Intact <0.015% Interior cream metal door Interior Walls Intact <0.012% Interior blue gypsum board Interior Walls Intact <0.0080%
Building M228
Building M228 is an Academic Instruction building. The building exterior is stucco with brick
% by Weight Exterior cream texture, CMU Exterior Walls Fair <0.0080% Exterior white metal door Exterior Walls Intact <0.022% Interior cream Gypsum board Interior Walls Intact <0.0082% Interior white Gypsum board Interior Walls Intact <0.010% Interior black wood base Interior Walls Intact <0.023% Interior cream metal door Interior Walls Intact <0.0081%
Building M229
Building M229 is an Academic Instruction building. The building exterior is stucco with brick board with gypsum board ceilings. (16) samples were taken for analysis.
% by Weight Exterior cream texture, CMU Exterior Walls Fair 0.012% Exterior white metal door Exterior Walls Intact <0.012% Interior cream Gypsum board Interior Walls Intact <0.0080% Interior white Gypsum board Interior Walls Intact <0.0081% Interior black wood base Interior Walls Intact <0.012% Interior cream metal door Interior Walls Intact <0.0080% Interior blue gypsum board Interior Walls Intact <0.015% Interior red gypsum board Interior Walls Intact <0.0080%
Building M231
Building Description and Findings (Inspected 04-20-20)
Building M231 is an abandoned lodging facility. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board/plaster and the
White CMU/Concrete Textured Wall Exterior Intact 0.011% White Steel Column Exterior Intact 2.4% Cream Gypsum Board Interior Walls Intact <0.0080% White Wood Trim Interior Trim Intact <0.0080% White Metal Door Frames Interior Doors Intact <0.014%
White CMU/Concrete Textured Wall White Steel Column
Building M232
Building M232 is an SNCO Billeting facility. The building exterior is stucco with brick framed windows/doors. The roof consists of asphalt shingles. The interior walls are gypsum board with gypsum board ceilings. (6) samples were taken for analysis.
% by Weight Exterior cream texture finish Exterior Walls Fair 0.014% Interior white Gypsum board Interior Walls Intact <0.0080% Interior white metal door system Interior Walls Intact <0.0080%
Exterior cream texture finish
Building M233
Building M233 is an abandoned office building. The building exterior is masonry with a
Cream Textured Wall Exterior Intact 0.027% Cream Gypsum Board Interior Intact <0.0080% White Metal Door System Interior Intact <0.0080%
Building M234
Building Description and Findings (Inspected 04-21-20)
Building M234 is an abandoned office building. The building exterior is masonry with a
Cream Gypsum Board Ceiling Interior Intact <0.0080% Cream CMU/Concrete with Textured Finish Exterior Intact 0.018%
White Metal Door Frame Interior Intact <0.0080%
Cream CMU/Concrete with Textured Finish
Building M235
Building M235 is an abandoned office building. The building exterior is masonry with a
Cream Gypsum Board Ceiling Interior Intact <0.0080% Cream CMU/Concrete with Textured Finish Exterior Intact 0.018%
White Metal Door Frame Interior Intact <0.0080%
Building M236
Building M236 is a bachelor enlisted quarters facility. The building exterior is stucco with brick board with gypsum board ceilings. (6) samples were taken for analysis.
% by Weight Exterior cream texture finish Exterior Walls Fair 0.030% Interior white Gypsum board Interior Walls Intact <0.0080% Interior white metal door frames Interior Walls Intact <0.016%
Exterior cream texture finish
Building M237
Building M237 is an abandoned storage building. The building exterior is masonry with a textured finish. There are no interior partitions and the roof is wood framed with asphalt shingles.
Cream CMU/Concrete with Textured Finish Exterior Intact 0.018% Gray CMU Masonry Interior Fair 0.83%
Gray CMU Masonry
Building M301
Building M301 is a storage building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board/plaster and the roof is
Cream Exterior Stucco Exterior Intact 0.080% Interior Cream Gypsum Board Interior Intact 0.0096% Exterior Red Brick Trim Interior Intact 0.035% Interior Black Metal Door System Interior Intact <0.0080% Interior Cream CMU Interior Intact 1.3% Interior Black Concrete Base Interior Fair 0.36%
Cream Exterior Stucco Interior Cream Gypsum Board Exterior Red Brick Trim
Interior Cream CMU Interior Black Concrete Base
Building M302
Building M302 is an abandoned office building. The building exterior is masonry with a textured finish. Interior partitions are wood framed with gypsum board/plaster and the
Cream CMU/Concrete with Textured Finish Exterior Intact 0.22% Red Brick Trim Interior Intact 0.065% Cream Gypsum Board Interior Intact 0.0099% White Gypsum Board Interior Intact <0.0080%
Red Brick Trim
Building M314
Building Description and Findings (Inspected 05-21-20)
Building M314 is an abandoned office building. The building exterior is masonry with a
Cream Stucco Exterior Intact 0.87% Cream CMU Interior Intact 1.8% Cream Gypsum Board Interior Intact 0.013% White Wood Interior Intact 0.011%
Cream Stucco
White Wood
Building M319
Building M319 is an abandoned office building. The building exterior is masonry with a
Cream CMU/Concrete with Textured Finish Exterior Walls Intact 0.11% Red Brick Trim Exterior Trim Intact 0.30% Cream CMU Interior Walls Intact 4.4% White Gypsum Board Interior Walls Intact 0.012% White Wood Interior Trim Intact 0.012% White Wood Siding Exterior Intact 22%
White Gypsum Board White Wood
Building M419
Building M419 is an abandoned office building. The building exterior is masonry with a
Cream Stucco Exterior Walls Intact 0.0095% Red Brick Trim Exterior Trim Intact 0.31% Cream CMU Interior Walls Fair 0.30% Cream Gypsum Board Interior Walls Intact <0.0080% White Metal Door System Interior/Exterior Doors Intact <0.0080% White Wood Siding Exterior Poor 33%
Cream Stucco
Structure SM156
Building SM156 is utility pump station that previously had a canopy that was destroyed by Hurricane Florence.
Yellow Steel Column Steel Column Intact 28%
Yellow Steel Column
Recommendations
A. Any demolition/renovation work in which lead coated surfaces are disturbed must be in compliance with all Federal, State, and Local regulations. All work should be conducted by workers trained in "lead safe practices" as outlined by
OSHA.
B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to contain lead-based paint until sampling by a state of North Carolina licensed Lead Inspector personnel and analysis by an Accredited and state of North Carolina licensed laboratory can be performed.
See attached for Plan Locations, Lead Laboratory Results, and Chain of Custody.
If further information is required, please contact me at 1-252-636-8778
Report Prepared by:
Christopher B. Walker North Carolina Lead Inspector Accreditation# 110239 The Walker Group Architecture, Inc.
PO Box 541 New Bern, NC 28560
ConcentrationAnalyzed Weight Reporting Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 8/31/2020 01:15 PM
M120
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
022005017 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
<0.0080 % wt9/1/2020 .2634 g022005017-0001 0.0080
Client Sample Pb-01
% wt
<0.0080 % wt9/1/2020 .2564 g022005017-0002 0.0080
Client Sample Pb-02
% wt
0.021 % wt9/1/2020 .2654 g022005017-0003 0.0080
Client Sample Pb-03
% wt
0.022 % wt9/1/2020 .2584 g022005017-0004 0.0080
Client Sample Pb-04
% wt
<0.0080 % wt9/1/2020 .2554 g022005017-0005 0.0080
Client Sample Pb-05
% wt
<0.012 % wt9/1/2020 .1677 g022005017-0006 0.012
Client Sample Pb-06
% wt
0.31 % wt9/1/2020 .2623 g022005017-0007 0.0080
Client Sample Pb-07
% wt
<0.0080 % wt9/1/2020 .2584 g022005017-0008 0.0080
Client Sample Pb-08
% wt
Page 1 of 2Test Report PB w/RD/I-7.32.3 Printed: 9/1/2020 10:37:36 AM
James Cole, Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 09/01/2020 10:37:36 http://www.EMSL.com mailto:greensborolab@emsl.com
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 8/31/2020 01:15 PM
M120
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
022005017 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 2 of 2Test Report PB w/RD/I-7.32.3 Printed: 9/1/2020 10:37:36 AM
James Cole, Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 09/01/2020 10:37:36
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 02/20/18 10:00 AM
Installation Reset FY-18 - Building M151A
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
2/17/2018Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021801176 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
<0.011 % wt2/23/2018 .1857 g021801176-0001 0.011
Client Sample 2/17/2018 pb-01
% wt
<0.011 % wt2/23/2018 .1901 g021801176-0002 0.011
Client Sample 2/17/2018 pb-02
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 1 of 1Test Report PB w/RD/I-7.32.3 Printed: 2/23/2018 10:02:45 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 02/23/2018 08:05:21
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 02/20/18 10:00 AM
Installation Reset FY-18 - Building M151B
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
2/17/2018Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021801175 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
<0.011 % wt2/23/2018 .1853 g021801175-0001 0.011
Client Sample 2/17/2018 pb-01
% wt
<0.016 % wt2/23/2018 .1239 g021801175-0002 0.016
Client Sample 2/17/2018 pb-02
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 1 of 1Test Report PB w/RD/I-7.32.3 Printed: 2/23/2018 10:00:02 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 02/23/2018 08:04:27
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 02/20/18 10:00 AM
Installation Reset FY-18 - Building M151C
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
2/17/2018Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021801174 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
<0.0081 % wt2/23/2018 .2483 g021801174-0001 0.0081
Client Sample 2/17/2018 pb-01
% wt
<0.0080 % wt2/23/2018 .2602 g021801174-0002 0.0080
Client Sample 2/17/2018 pb-02
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 1 of 1Test Report PB w/RD/I-7.32.3 Printed: 2/23/2018 9:59:21 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 02/23/2018 08:03:44
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 02/20/18 10:00 AM
Installation Reset FY-18 - Building M151D
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
2/17/2018Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021801173 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
<0.0080 % wt2/23/2018 .2727 g021801173-0001 0.0080
Client Sample 2/17/2018 pb-01
% wt
<0.0080 % wt2/23/2018 .3050 g021801173-0002 0.0080
Client Sample 2/17/2018 pb-02
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 1 of 1Test Report PB w/RD/I-7.32.3 Printed: 2/23/2018 9:58:42 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 02/23/2018 08:02:56
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 04/18/19 1:00 PM
Bldg M200
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
4/10/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021902591 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Exterior Cream Textured Wall
0.062 % wt4/24/2019 .2617 g021902591-0001 0.0080
Client Sample 4/10/2019 pb-01
% wt
Site: Exterior Cream Textured Wall
0.22 % wt4/24/2019 .288 g021902591-0002 0.0080
Client Sample 4/10/2019 pb-02
% wt
Site: Interior Cream CMU
0.33 % wt4/24/2019 .2647 g021902591-0003 0.0080
Client Sample 4/10/2019 pb-03
% wt
Site: Interior Cream CMU
0.34 % wt4/24/2019 .2704 g021902591-0004 0.0080
Client Sample 4/10/2019 pb-04
% wt
Site: White Fiber Board Ceiling
6.2 % wt4/24/2019 .2591 g021902591-0005 0.80
Client Sample 4/10/2019 pb-05
% wt
Site: White Fiber Board Ceiling
5.7 % wt4/24/2019 .317 g021902591-0006 0.80
Client Sample 4/10/2019 pb-06
% wt
Site: White Interior Wood Door System
0.099 % wt4/24/2019 .2641 g021902591-0007 0.0080
Client Sample 4/10/2019 pb-07
% wt
Site: White Interior Wood Door System
1.0 % wt4/24/2019 .3045 g021902591-0008 0.080
Client Sample 4/10/2019 pb-08
% wt
Site: Black Interior CMU <0.0080 % wt4/24/2019 .2596 g021902591-0009 0.0080
Client Sample 4/10/2019 pb-09
% wt
Site: Black Interior CMU
0.018 % wt4/24/2019 .2587 g021902591-0010 0.0080
Client Sample 4/10/2019 pb-10
% wt
Site: Gray Interior CMU
6.9 % wt4/24/2019 .3431 g021902591-0011 0.80
Client Sample 4/10/2019 pb-11
% wt
Page 1 of 2Test Report PB w/RD/I-7.32.3 Printed: 4/24/2019 3:27:51 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 04/24/2019 15:27:51
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 04/18/19 1:00 PM
Bldg M200
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
4/10/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021902591 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Gray Interior CMU
7.9 % wt4/24/2019 .3612 g021902591-0012 0.80
Client Sample 4/10/2019 pb-12
% wt
Site: Red Interior Wood Floor <0.0080 % wt4/24/2019 .3137 g021902591-0013 0.0080
Client Sample 4/10/2019 pb-13
% wt
Site: Red Interior Wood Floor <0.0080 % wt4/24/2019 .2507 g021902591-0014 0.0080
Client Sample 4/10/2019 pb-14
% wt
Site: Exterior White Wood Facia
6.5 % wt4/24/2019 .3168 g021902591-0015 0.80
Client Sample 4/10/2019 pb-15
% wt
Site: Exterior White Wood Facia 16 % wt4/24/2019 .2947 g021902591-0016 0.80
Client Sample 4/10/2019 pb-16
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 2 of 2Test Report PB w/RD/I-7.32.3 Printed: 4/24/2019 3:27:51 PM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 04/24/2019 15:27:51
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 04/24/19 10:45 AM
Bldg M201
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
4/16/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021902745 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Exterior Cream Textured Wall
0.059 % wt4/29/2019 .2697 g021902745-0001 0.0080
Client Sample 4/16/2019 pb-01
% wt
Site: Exterior Cream Textured Wall
0.042 % wt4/29/2019 .3154 g021902745-0002 0.0080
Client Sample 4/16/2019 pb-02
% wt
Site: Inteiror Cream Gypsum Board
0.012 % wt4/29/2019 .2661 g021902745-0003 0.0080
Client Sample 4/16/2019 pb-03
% wt
Site: Inteiror Cream Gypsum Board <0.0080 % wt4/29/2019 .2564 g021902745-0004 0.0080
Client Sample 4/16/2019 pb-04
% wt
Site: Interior Blue Gypsum Board <0.0080 % wt4/29/2019 .276 g021902745-0005 0.0080
Client Sample 4/16/2019 pb-05
% wt
Site: Interior Blue Gypsum Board <0.0091 % wt4/29/2019 .2206 g021902745-0006 0.0091
Client Sample 4/16/2019 pb-06
% wt
Site: Interior Red Gypsum Board <0.0080 % wt4/29/2019 .2946 g021902745-0007 0.0080
Client Sample 4/16/2019 pb-07
% wt
Site: Interior Red Gypsum Board <0.0080 % wt4/29/2019 .2957 g021902745-0008 0.0080
Client Sample 4/16/2019 pb-08
% wt
Site: Cream Metal Door Systems <0.0080 % wt4/29/2019 .3237 g021902745-0009 0.0080
Client Sample 4/16/2019 pb-09
% wt
Site: Cream Metal Door Systems
0.0095 % wt4/29/2019 .2275 g021902745-0010 0.0088
Client Sample 4/16/2019 pb-10
% wt
Site: Cream Wood Trim
0.016 % wt4/29/2019 .3006 g021902745-0011 0.0080
Client Sample 4/16/2019 pb-11
% wt
Page 1 of 2Test Report PB w/RD/I-7.32.3 Printed: 4/29/2019 10:29:02 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 04/29/2019 10:29:02
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 04/24/19 10:45 AM
Bldg M201
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
4/16/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021902745 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Cream Wood Trim <0.011 % wt4/29/2019 .1746 g021902745-0012 0.011
Client Sample 4/16/2019 pb-12
% wt
Site: Cream Interior Conc Column
2.1 % wt4/29/2019 .2623 g021902745-0013 0.080
Client Sample 4/16/2019 pb-13
% wt
Site: Cream Interior Conc Column
1.0 % wt4/29/2019 .2826 g021902745-0014 0.080
Client Sample 4/16/2019 pb-14
% wt
Site: Interior Cream CMU
2.3 % wt4/29/2019 .2782 g021902745-0015 0.080
Client Sample 4/16/2019 pb-15
% wt
Site: Interior Cream CMU
1.7 % wt4/29/2019 .2724 g021902745-0016 0.080
Client Sample 4/16/2019 pb-16
% wt
Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.
Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint
Below Method Reporting Limit (RL)
These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.
Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.
No responsibility or liability is assumed for the manner in which the results are used or interpreted.
Page 2 of 2Test Report PB w/RD/I-7.32.3 Printed: 4/29/2019 10:29:02 AM
James Cole, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.
Initial report from 04/29/2019 10:29:02
Detection LimitLab ID: LeadCollected
Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563
Received: 04/18/19 1:00 PM
Bldg M205
Fax: (252) 636-8992 Phone: (252) 636-8778
Project:
4/10/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
EMSL Analytical, Inc.
706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com
021902582 CustomerID: WALK85 CustomerPO:
ProjectID:
EMSL Order:
Site: Exterior Cream Textured Wall
0.012 % wt4/22/2019 .3635 g021902582-0001 0.0080
Client Sample 4/10/2019 pb-01
% wt
Site: Exterior Cream Textured Wall
0.011 % wt4/22/2019 .2774 g021902582-0002 0.0080
Client Sample 4/10/2019 pb-02
% wt
Site: Interior Cream CMU <0.0080 % wt4/22/2019 .2678 g021902582-0003 0.0080
Client Sample 4/10/2019 pb-03
% wt
Site: Interior Cream CMU <0.0091 % wt4/22/2019 .2192 g021902582-0004 0.0091
Client Sample 4/10/2019 pb-04
% wt
Site: White Interior Wood Trim <0.016 % wt4/22/2019 .1219 g021902582-0005 0.016
Client Sample 4/10/2019 pb-05
% wt
Site: White Interior Wood Trim <0.022 % wt4/22/2019 .093 g021902582-0006 0.022
Client Sample 4/10/2019 pb-06
%…
This is the start of the file's text. The full file is on GovTribe.