LOCATION EQUIPMENT TYPE UNITS MAKE MODEL # SERIAL # SIZE/OUTPUT

MANUFACTURER

DATE

HVAC Equipment

ROOFTOP

ROOFTOP WEST WING AIR HANDLING UNIT (RTU-1) 1 CARRIER 48HJR007--F55SHS 4109G30260

ROOFTOP NORTH WING AIR HANDLING UNIT (RTU-2) 1 CARRIER 48HJR008-MF54SHS 4209G50595

ROOFTOP NORTH WING CONDENSER UNIT (HPCU-1) 1 CARRIER 25HBB324C310 3109E01188

ROOFTOP VARIOUS EXHAUST FANS 13

ROOFTOP REZNOR UNITS 2 REZNOR RGB125-8-S-MV EBAD66M8N09907MV4 50 HP Apr-01

EXTERIOR

GARAGE AREA AIR HANDLER HEAT/COOL 1 TRANE TVDBGBAE0E30BRGG K87010398 BTU/HR: 260,000 CFM: 4,000

EXTERIOR ON FENCED CONCRETE PAD AIR-COOLED COLD GENERATOR 1 CARRIER 30RAN055--E511EU 4309Q57979

EXTERIOR ON FENCED CONCRETE PAD AIR-COOLED COLD GENERATOR 1 CARRIER 30RAP0405FA07D00 3210Q40226

BOILER ROOM

CENTER OF BOILER ROOM GAS FIRED HOT WATER BOILER 1 H B SMITH 28A-9-050379 29570092 1,941,000 BTU/HR

CENTER OF BOILER ROOM POWER FLAME BURNER 1 PFB C2-C-10B 29570092

CENTER OF BOILER ROOM CIRC PUMPS (RED BOILER) 1 BELL & GOSSETT M10532-1190

CENTER OF BOILER ROOM CIRC PUMPS (GOLD ABOVE BOILER) 1 BELL & GOSSETT

EAST SIDE OF BOILER ROOM AIRTROLL FITTING (SMALL, RED) 2 BELL & GOSSETT ATFL C30 112014

SOUTHEAST CORNER OF BOILER ROOM UNIT HEATER 1 BEACON MORRIS HB-118A 01BUA-HBA11811 D01195937002001

SOUTH SIDE OF BOILER ROOM

RECIRCULATING PUMPS (GREEN) -

DOMESTIC HOT WATER

* 2 * TACO F-E250-8E-2E-1F-4L0

NORTHWEST CORNER OF BOILER RM CHILLED WATER PUMP P-1 (NEW, RED) 1 BELL & GOSSETT 1510 C112065-01H01

NORTHWEST CORNER OF BOILER RM CHILLED WATER PUMP P-2 (NEW, RED) 1 BELL & GOSSETT 1510 C112065-02H01

NORTHEAST CORNER OF BOILER RM CHILLED WATER PUMP (RED) 2 BELL & GOSSETT 2BC 09-2786

IMMEDIATELY WEST OF BOILER

LARGE STEEL STORAGE TANK (GRAY,

STACKED)

1 BAP2X0025942

IMMEDIATELY WEST OF BOILER

LARGE STEEL STORAGE TANK (GRAY,

STACKED)

1 BAP2X0025943

EAST SIDE OF BOILER ROOM

SUSPENDED STEEL TANK (BLACK/DK

GRAY)

EAST SIDE OF BOILER ROOM SUSPENDED STEEL TANK (ASBESTOS ?) 1

SOUTHWEST CORNER OF BOILER RM SMALL TANK (RED) EXT-1 1 BELL & GOSSETT YR-2010 211549 D15V

SOUTHWEST CORNER OF BOILER RM SMALL TANK (RED) EXT-2 1 BELL & GOSSETT YR-2009 197233 D15V

SOUTHEAST CORNER OF BOILER ROOM SMALL TANK (BLUE) CF-1 1 NEPTUNE DBF-5HP 5 HP/5 GAL/300 PSI

NORTHWEST CORNER OF BOILER RM SMALL TANK (BLUE) CF-2 1 NEPTUNE DBF-5HP 5 HP/5 GAL/300 PSI

WEST SIDE OF BOILER ROOM HOT WATER TANK 1 A.O. SMITH BT-100-300 F07M009333

WEST SIDE OF BOILER ROOM HOT WATER TANK 1 A.O. SMITH BT-100-300 F0827M000557

INTERIOR

BASEMENT FITNESS ROOM

CEILING MOUNTED AIR HANDLING UNIT

(HP-1)

1 CARRIER FY4ANF030 2609A69754 1/4 HP NEW

BASEMENT FITNESS ROOM CONDENSATE PUMP (CP-1) 1 554965 08J1702394

GARAGE AREA - OVER BATHROOM AIR HANDLER HEAT/COOL 1 TRANE TVDBGBAE0E30BRGG K87010398 BTU/HR: 260,000 CFM: 4,000

GARAGE AREA - CEILING/CORNERS HOT WATER HEATING UNITS 6 TRANE

GARAGE AREA - OVER BATHROOM

RECIRCULATING PUMP -

DOMESTIC HOT WATER

2 BELL & GOSSETT 1/6 HP

GARAGE AREA - WESTERN SIDE BOOSTER PUMP 1 BELL & GOSSETT 1/4 HP

WEST BASEMENT FLOOR STORAGE HOT WATER HEATING UNITS 1 BEACON MORRIS HB-118A K01233158001 CFM 500

WEST BASEMENT FLOOR STORAGE HOT WATER HEATING UNITS 1 BEACON MORRIS HB-118A K01233158002 CFM 500

WEST BASEMENT FLOOR STORAGE HOT WATER HEATING UNITS 1 BEACON MORRIS HB-118A K01233158003 CFM 500

NOSC BRONX EQUIPMENT INVENTORY FOR PM PROGRAM

FIRST FLOOR DRILL BAY AREA -

CEILING/CORNERS

HOT WATER HEATING UNITS 6

FIRST FLOOR SERVER ROOM 118 COOLING/EXHAUST 1 LIEBERT MMD18A-P00H0 0320V77757

1ST FLOOR MEDICAL OFFICE CLOSET HOT WATER TANK (WHITE) 1 BRADFORD M-I-30R10DS-13 KF1714398 30 GALLON

WEST BASEMENT WING - NEXT TO G14 HEATING UNIT 1

WEST BASMENT STAIRWELL HEATING UNIT 1

WEST 1ST FLOOR - NEXT TO CO OFFICE HEATING UNIT 1

WEST 1ST FLOOR STAIRWELL HEATING UNIT 1

EAST 1ST FLOOR CENTER EXIT HEATING UNIT 1

EAST 1ST FLOOR STAIRWELL HEATING UNITS 3

MAIN ENTRANCE (NORTH) HEATING UNIT 1

MAIN ENTRANCE (SOUTH)

HEATING UNITS (1 LARGE TALL IN

BREEZEWAY)

(1 LONG INTERIOR)

MAIN CENTER STAIRWELL

B/W 1ST & 2ND FLR

HEATING UNIT (1 LONG) 1

WEST 2ND FLOOR - STAIRWELL HEATING UNIT 1

WEST 2ND FLOOR - NEXT TO RM 223 HEATING UNIT (1 LARGE) 1

MIDDLE 2ND FLOOR ROOF ACCESS HEATING UNIT 1

VARIOUS LOCATIONS PIR - LIGHT/AC/HEAT AUTO DETECTORS 85+ NEW

VARIOUS LOCATIONS FAN COIL UNITS (FCU) 67 TRANE NEW

Fire Suppression Description Manufacturer Type Size Location

50 PORTABLE FIRE EXTINGUISHERS VARIOUS ABC 20 LBS DISTRIBUTED

THROUGHOUT THE

BUILDING

WET PIPE SPRINKLER SYSTEM AUTOMATIC SPRINKLER WET PIPE 4 IN RISER BASEMENT CAGE

FIRE DETECTION ALARM PANEL FIRELITE FIRE/SMOKE

DETECTION, PULL

STATIONS &

SPRINKLER FLOW

16 ZONE (9 USED) PANEL LOCATED AT BLDG

ENTRANCE, DETECTORS

LOCATED THROUGHOUT

BUILDING

Emergency Lighting and Exit Signs

Description Units MFGR and Model Type Location

EMERGENCY LIGHTS 21 VARIOUS WALL MOUNTED DISTRIBUTED

THROUGHOUT BLDG

ILLUMINATED EXIT SIGNS 20 VARIOUS CEILING AND WALL

MOUNTED

DISTRIBUTED

THROUGHOUT BLDG

Boiler and UPV Certification Dates

Description MFGR and No. Model No. Serial No. Capacity Year Location Last cert date

1 OIL FIRED HOT WATER BOILER H B SMITH 28A-9 28A-9-050379 1,941,000 BTU/HR 2006

BLDG. 100, BOILER ROOM IN

BASEMENT Mar-19

Backflow Devices DESCRIPTION MANUFACTURER MODEL NO. PIPE SIZE LOCATION

1 POTABLE WATER SERVICE CONBRACO NA 2 INCH BASEMENT

Emergency Generator

DESCRIPTION MANUFACTURER MODEL NO.

1 DIESEL EMERGENCY GENERATOR CUMMINS 125DSGAB

Security Gates and Turnstiles

DESCRIPTION MANUFACTURER

2 ENTRY GATE

2 TURNSTILE

Overhead Doors Location Size Manufacturer

1 Ground Floor VMF 14x14

2 Ground Floor VMF 8x14 Lift Master

1 2nd Floor 8x8 Fire Door (Roll up)

FACILITY # LOCATION EQUIPMENT TYPE UNITS MAKE MODEL # SERIAL # SIZE/OUTPUT

MANUFACTURER

DATE

HVAC Equipment

ROOFTOP

BLDG 1 ROOF - SOUTHERN SIDE 1 TRANE YFD150E4HAAA 919100493D 460-3-60 May-09

BLDG 1 ROOF - SOUTHERN SIDE ROOF TOP UNIT #1 (RTU-1) 1 SEMCO FV2000T-6RNYAB 50761/M048523-01

BLDG 1 ROOF - WESTERN SIDE AIR HANDLER - ROOF TOP UNIT #2 (RTU-2) 1 TRANE YSC092E4RZA0KD002A1B00000D 918100702L Apr-09

BLDG 1 ROOF - EASTERN SIDE AIR HANDLER - ROOF TOP UNIT #3 (RTU-3) 1 TRANE YSC092E4RZA0KD002A1B00000D 918100710L 460-3-60 Apr-09

BLDG 1 ROOF - EASTERN SIDE AIR HANDLER - ROOF TOP UNIT #4 (RTU-4) 1 TRANE YCD150EH4HAAA 919100568D 460-3-60 May-09

BLDG 1 ROOF - SOUTHERN SIDE AIR HANDLER - ROOF TOP UNIT #5 (RTU-5) 1 TRANE YCD150EH4HAAA 919100489D 460-3-60 May-09

BLDG 1 ROOF - SOUTHERN SIDE AIR HANDLER - ROOF TOP UNIT #6 (RTU-6) 1 TRANE YCD150EH4HAAA 919100565D 460-3-60 Feb-09

BLDG 1 ROOF - WESTERN SIDE AIR HANDLER - ROOF TOP UNIT #7 (RTU-7) 1 TRANE YHC060E4RZ0HD202A1B00000C 918101126L Apr-09

BLDG 1 ROOF - NORTHERN SIDE AIR HANDLER - ROOF TOP UNIT #8 (RTU-8) 1 TRANE YHC102A4RMA0015 613100999L 460-3-60 Mar-06

BLDG 1 ROOF - NORTHERN SIDE ROOF TOP UNIT #8 (RTU-8) 1 SEMCO FVTS000H-6RN4AB 50761/M048524-01

BLDG 1 ROOF EXHAUST FAN - FOR TOILETS 1 COOK 135C3B 1370 CFM

BLDG 1 ROOF ABOVE N-5 ERV-1 ENERGY RECOVERY VENTILATION 1 CARNES WPBB30BTVSSGEHKD 213991.004 S=3HP R=3HP

BLDG 1 ROOF ABOVE N-5 ERV-2 ENERGY RECOVERY VENTILATION 1 CARNES WPBB10BTVRRAEHKD 213991.003 S=3/4HP R=3/4HP

EXTERIOR

BLDG 1 OUTSIDE OF ROOM LN6 CONDENSING UNIT 1 LIEBERT PFH027A-PL3 0328N80106 3 TON 2001

BOILER ROOM

BLDG 1 BOILER ROOM LS3 BOILER, HOT WATER, NATURAL GAS 1 TELEDYNE VW1000MN20CCABX M97D03301 NB # 77733 850 MBH

BLDG 1 BOILER ROOM LS3 CIRCULATOR PUMP BOILER 1 ITT BELL & GOSSETT SERIES 60 10K090068 B14T C69

BLDG 1 BOILER ROOM LS3 STORAGE TANK (HW) 1 * LAARS

BLDG 1 BOILER ROOM LS3 MIXING VALVE 1 LEONARD THERMO-STATIC TM5097-0037 UNKNOWN

BLDG 1 BOILER ROOM LS3 CIRCULATOR PUMP DOMESTIC HOT WATER 1 ITT BELL & GOSSETT NBF-22, CLASS F 103252 M59

BLDG 1 LS3 MECH ROOM BOILER, HOT WATER, NATURAL GAS 1 LARRS NEOTHERM-NTV-285NXN3 G13279827 285,000BTHU/h

INTERIOR

BLDG 1 ROOM N-5 & LS-6 ELECTRIC BASEBOARD HEATER 2 TPI HQC 03 UNKNOWN 500 WATT/277 VOLT

BLDG 1 ROOMS N-5, N-6, LS-3, SW-1 ELECTRIC BASEBOARD HEATER 4 TPI HQC407 UNKNOWN 1000 WATT/277 VOLT

BLDG 1 SW-3 ELECTRIC BASEBOARD HEATER 1 MARLEY HC2574HB UNKNOWN 1000 WATT/277 VOLT

BLDG 1 SW-3 ELECTRIC BASEBOARD HEATER 1 TPI HQC 611 UNKNOWN 1500 WATT/277 VOLT

BLDG 1 ROOM P-2 & LS-5 CABINET HEATER UNIT 2 TPI AFA7-300 G3325TTD 175 CFM/3000 WATT/277 VOLT

BLDG 1 ROOM LP-1 & P-2 CABINET HEATER UNIT 2 TPI AFA7-150 G3323TTD 175 CFM/1500 WATT/277 VOLT

Fire Suppression

Description Manufacturer Type Size Location

12 PORTABLE FIRE EXT (7)M-10HI SA ABC (5)M-5ABC-II-100 ABC 20 LBS

DISTRIBUTED THROUGHOUT THE

BUILDING

3 PORTABLE FIRE EXT 5 LBS

Location (BLDG-FLR-

RM)

Wet Pendent 5.6K - HEAD Wet Spec App 4.2K - HEAD Wet QR Upright

8.0K - HEAD

Wet QR Upright 5.6K - HEAD Recss Pend 8.0 - HEAD Wet Concealed 5.6 - HEAD Sidewall 5.6K

Emergency Lighting and Exit Signs

Description Units MFGR Type Location

EMERGENCY LIGHTS 60 TYCO WALL MOUNTED DISTRIBUTED THROUGHOUT BLDG

ILLUMINATED EXIT SIGNS 30 TYCO CEILING AND WALL MOUNTED DISTRIBUTED THROUGHOUT BLDG

Boiler and UPV Certification Dates

Description MFGR Model No. Serial No. Capacity Year Location Last Cert date

1 BOILER, HOT WATER, NATURAL GAS TELEDYNE LAARS G13279827 850 MBH 2003 ROOM LS3 Mar-19

1 UPV LAARS/Bradford White 07708-01 Mar-19

Backflow Devices DESCRIPTION MANUFACTURER MODEL NO. PIPE SIZE LOCATION

1 POTABLE WATER SERVICE CONBRACO NA 2 INCH BASEMENT

1 SPRINKLER SERVICE WILKINS / ZURN 350-AST 6 IN. SPRINKLER SERVICE IN ROOM LS-8

Emergency Generator DESCRIPTION MANUFACTURER MODEL NO.

1 DIESEL EMERGENCY GENERATOR CUMMINS 125DSAGB

Elevator/Lift DESCRIPTION Speed (FPM) Capacity Manufacturer INSTALLED BY DISTANCE Location (BLDG-FLR-RM) MFG Date

1 INCLINE CHAIR LIFT 12FT PER MIN 1 SAVARIA- OMEGA NH LIFT NEW IPSWICH NH 5 STEPS W1 TO 2 2013

NOSC QUINCY EQUIPMENT INVENTORY FOR PM PROGRAM

LOCATION (BLDG‐FLR‐RM) EQUIPMENT TYPE ID MANUFACTURER MODEL NUMBER SERIAL NUMBER TONNAGE/HP SIZE OF FILTERS

HVAC Equipment

ROOFTOP

* AIR HANDLER - ROOF

TOP UNIT #1 (RTU-1)

RTU-1 CARRIER/CENTURIAN 48PGEC04HA-60-S4 2809G10013

ROOFTOP

* AIR HANDLER - ROOF

TOP UNIT #2 (RTU-2)

RTU-2 CARRIER/CENTURIAN 48PGEC05HA-60-S4 2809G10023

ROOFTOP

* AIR HANDLER - ROOF

TOP UNIT #3 (RTU-3)

RTU-3 CARRIER/CENTURIAN 48PGNC06HA-60-S4 2909G40031

ROOFTOP

* AIR CONDITIONING

UNIT

CARRIER 38HDF024--3 1909X91499

ROOFTOP

* AIR CONDITIONING

UNIT

CARRIER 38HDF024--3 1909X91507

ROOFTOP

* AIR CONDITIONING

UNITS

CARRIER N/A N/A

ROOFTOP

* AIR CONDITIONING

UNITS

CARRIER N/A N/A

NOSC‐1‐RM 104 FAN COIL UNIT FCU‐1 JOHNSON CONTROLS FHP60 6ACN007856 (2) 1/6 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 111 FAN COIL UNIT FCU‐2 JOHNSON CONTROLS FHP40 6ACN005852 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 111 FAN COIL UNIT FCU‐3 JOHNSON CONTROLS FHP25 6ACN005853 (1) 1/15 1"THROWAWAY 26X8.5X1

NOSC‐1‐RM 160 FAN COIL UNIT FCU‐4 JOHNSON CONTROLS FHP30 6ACN007857 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 155 FAN COIL UNIT FCU‐5 JOHNSON CONTROLS FHP30 6ACN007858 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 155 FAN COIL UNIT FCU‐6 JOHNSON CONTROLS FHP40 6ACN007861 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 150 FAN COIL UNIT FCU‐7 JOHNSON CONTROLS FHP25 6ACN007862 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 150 FAN COIL UNIT FCU‐8 JOHNSON CONTROLS FHP30 6ACN007867 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 134 FAN COIL UNIT FCU‐9 JOHNSON CONTROLS FHP30 6ACN007859 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 144 FAN COIL UNIT FCU‐10 JOHNSON CONTROLS FHP25 6ACN007865 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 143 FAN COIL UNIT FCU‐11 JOHNSON CONTROLS FHP25 6ACN007864 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 139 FAN COIL UNIT FCU‐12 JOHNSON CONTROLS FHP30 6ACN007868 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 137 FAN COIL UNIT FCU‐13 JOHNSON CONTROLS FHP40 6ACN007869 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 132 FAN COIL UNIT FCU‐14 JOHNSON CONTROLS FHP40 6ACN005854 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 131 FAN COIL UNIT FCU‐15 JOHNSON CONTROLS FHP30 6ACN005855 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 130 FAN COIL UNIT FCU‐16 JOHNSON CONTROLS FHP40 6ACN005856 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 128 FAN COIL UNIT FCU‐17 JOHNSON CONTROLS FHP40 6ACN007870 (1) 1/6 1" THROWAWAY 20X8.5X1

NOSC‐1‐RM 123 FAN COIL UNIT FCU‐18 JOHNSON CONTROLS FHP25 6ACN007865 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 123 FAN COIL UNIT FCU‐19 JOHNSON CONTROLS FHP60 6ACN007871 (2) 1/6 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 135 FAN COIL UNIT FCU‐20 JOHNSON CONTROLS FHP30 6ACN007860 (1) 1/10 1" THROWAWAY 30X8.5X1

NOSC‐1‐RM 172 FAN COIL UNIT FCU‐21 JOHNSON CONTROLS FHP25 6ACN007866 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 120 FAN COIL UNIT FCU‐22 JOHNSON CONTROLS FHP30 6ACN005857 (1) 1/10 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 117 FAN COIL UNIT FCU‐23 JOHNSON CONTROLS FHP25 6ACN005858 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 115 FAN COIL UNIT FCU‐24 JOHNSON CONTROLS FHP25 6ACN005859 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 112 FAN COIL UNIT FCU‐25 JOHNSON CONTROLS FHP30 6ACN005860 (1) 1/10 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 113 FAN COIL UNIT FCU‐26 JOHNSON CONTROLS FHP30 6ACN005861 (1) 1/10 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 131A FAN COIL UNIT FCU‐27 JOHNSON CONTROLS FHP25 6CCN008146 (1) 1/15 1" THROWAWAY 26X8.5X1

NOSC‐1‐RM 101A CABINET UNIT HEATER CUH‐1 VULCAN RADIATOR CBS‐F‐10 N/A (2) 1/10 15/32"X8‐11/16"X57‐3/4"

NOSC‐1‐RM 110A CABINET UNIT HEATER CUH‐2 VULCAN RADIATOR CBS‐F‐10 N/A (1) 1/10 15/32"X8‐11/16"X31‐3/4"

NOSC‐1‐RM 109 CABINET UNIT HEATER CUH‐3 JOHNSON CONTROLS FHP40 6CCM004713 (1) 1/6 1" PLEATED (MERV 7) 20X8.5X1

NOSC‐1‐RM 126A CABINET UNIT HEATER CUH‐4 VULCAN RADIATOR CBS‐F‐10 N/A (1) 1/10 15/32"X8‐11/16"X31‐3/4"

NOSC‐1‐RM 163A CABINET UNIT HEATER CUH‐5 VULCAN RADIATOR CBS‐F‐10 N/A (1) 1/10 15/32"X8‐11/16"X31‐3/4"

NOSC‐1‐RM 103 UNIT HEATER UH‐1 VULCAN RADIATOR VV‐237 A1501353775001002 (1) 1/4 N/A

NOSC‐1‐RM 103 UNIT HEATER UH‐2 VULCAN RADIATOR VV‐237 A1501353775001001 (1) 1/4 N/A

NOSC‐1‐RM 169 FAN EF‐1 GREENHECK G‐095‐D 1395553714C (1) 1/8 N/A

NOSC‐1‐RM 175 FAN EF‐2 GREENHECK G‐095‐D 1395553814C (1) 1/8 N/A

ROOFTOP

*EXHAUST FAN - ROOM

EF-5

ROOFTOP

*EXHAUST FAN -

BASEMENT / BELOW RM

EF-7

NOSC‐ROOF‐RM 169 GRAVITY VENTILATOR OAI‐1 GREENHECK FGI N/A 500 CFM N/A

NOSC‐ROOF‐RM 111 GRAVITY VENTILATOR OAI‐2 GREENHECK FGI N/A 100 CFM N/A

NOSC‐ROOF‐RM 104 GRAVITY VENTILATOR GRH‐1 GREENHECK FGR N/A 600 CFM N/A

NOSC‐ROOF‐RM 129 GRAVITY VENTILATOR GRH‐2 GREENHECK FGR N/A 250 CFM N/A

NOSC‐ROOF‐NAVY ADMIN ENERGY RECOVERY UNIT ERV‐1 GREENHECK ERV‐10‐20L 13955651 (2) 1/3

OUTDOOR ‐ 2" MERV 13 EXHAUST ‐ 2"

MERV 8

NOSC PLAINVILLE EQUIPMENT INVENTORY FOR PM PROGRAM

NOSC‐ROOF‐USMC ENERGY RECOVERY UNIT ERV‐2 GREENHECK ERV‐10‐20L 13955652 (2) 1/3

OUTDOOR ‐ 2" MERV 13 EXHAUST ‐ 2"

MERV 8

NOSC‐ROOF‐CLASSROOMS ENERGY RECOVERY UNIT ERV‐3 GREENHECK ERVe‐20‐15L 13954417 (2) 3/4

OUTDOOR ‐ 2" MERV 13 EXHAUST ‐ 2"

MERV 8

NOSC‐ROOF‐RM 165 ENERGY RECOVERY UNIT ERV‐4 GREENHECK ERV‐10‐20L 13955653 (2) 1/3

OUTDOOR ‐ 2" MERV 13 EXHAUST ‐ 2"

MERV 8

NOSC‐ROOF‐NORTH/CENTRA

L SPACES

ENERGY RECOVERY UNIT ERV‐5 GREENHECK ERV‐20‐15L 13955654

(1) 3/4

(1) 1/2

OUTDOOR ‐ 2" MERV 13 EXHAUST ‐ 2"

MERV 8

NOSC‐BASEMENT‐RM 002 ELECTRIC HEATING COIL EHC‐1 NEPTRONIC DFCF00H 391717 130 CFM N/A

NOSC‐1‐RM 169

GEOTHERMAL WATER TO

WATER HEAT PUMP

HP‐1 FHP MANUFACTURING CO. WW240‐4CSC‐RXXNA

2940‐460‐000001‐77350271

CHILLER ‐ 221,324 BTuH HEATING ‐ 214,559 BTuH

N/A

NOSC‐1‐RM 169

GEOTHERMAL WATER TO

WATER HEAT PUMP

HP‐2 FHP MANUFACTURING CO. WW240‐4CSC‐RXXNA

2940‐460‐000002‐77350271

CHILLER ‐ 221,324 BTuH HEATING ‐ 214,559 BTuH

N/A

NOSC‐1‐RM 119 HEATING COIL HC‐1 JOHNSON CONTROLS

MA006090921G02C02003501F500S

F

N/A 550 CFM N/A

NOSC‐1‐RM 142 HEATING COIL HC‐2 JOHNSON CONTROLS

MA006111221G02C02003501F500S

F

N/A 675 CFM N/A

NOSC‐1‐RM 132 HEATING COIL HC‐3 JOHNSON CONTROLS

MA006101527G02C02003502F750S

F

N/A 1380 CFM N/A

NOSC‐1‐RM 165 HEATING COIL HC‐4 JOHNSON CONTROLS

MA006141224G02C02003501F500S

F

N/A 800 CFM N/A

NOSC‐1‐RM 134 HEATING COIL HC‐5 JOHNSON CONTROLS MA06091227F02C02003501F500SF N/A 1050 CFM N/A

NOSC‐1‐RM 169 PUMPS P‐1 TACO INC 1615C3E21661023 ED15850 (1) 3/4 N/A

NOSC‐1‐RM 169 PUMPS P‐2 TACO INC 1615C3E21661023 ED15850 (1) 3/4 N/A

NOSC‐1‐RM 133 PUMPS P‐3 TACO INC KV3009AE2JCB680M ED15850 (1) 5 N/A

NOSC‐1‐RM 133 PUMPS P‐4 TACO INC KV3009AE2JCB680M ED15850 (1) 5 N/A

NOSC‐1‐RM 169 PUMPS P‐5 TACO INC KV3009AE2JCB720M ED15850 (1) 3 N/A

NOSC‐1‐RM 169 PUMPS P‐6 TACO INC KV3009AE2JCB720M ED15850 (1) 3 N/A

NOSC‐1‐RM 169 PUMPS PB‐1 TACO INC 2420 N/A (1) 1/6 N/A

Boiler and UPV Certification Dates

LOCATION (BLDG‐FLR‐RM)

EQUIPMENT

DESCRIPTION

ID MANUFACTURER MODEL NUMBER SERIAL NUMBER MBH FUEL

NOSC‐1‐RM 169 BOILER B1 LOCHINVAR KBN400 K13H10282097 400 NATURAL GAS

NOSC‐1‐RM 169A

GEOTHERMAL WATER

HEATER

WH‐2 CLIMATEMASTER THW010AGW01NSBS S15118601

BOILER ROOM

BOILER (HOT WATER) GAS

FIRED

WH1 LOCHINVAR EWN200PM C11H00231726

BOILER ROOM

DOMESTIC HOT WATER

TANK

HWT LOCHINVAR RGA 0432 D983615 432 GALLON 1998

Backflow Devices

LOCATION (BLDG‐FLR‐RM)

EQUIPMENT

DESCRIPTION

ID MANUFACTURER MODEL NUMBER SERIAL NUMBER SIZE COMMENTS

SPRINKLER ROOM BACKFLOW DEVICE CONBRACO 40204A2 3/4 INCH SPRINKLER CHECK VALVE BYPASS

BOILER ROOM BACKFLOW DEVICE WATTS REGULATOR N/A 3 INCH POTABLE WATER SERVICE

Emergency Generator

LOCATION (BLDG‐FLR‐RM)

EQUIPMENT

DESCRIPTION

ID MANUFACTURER MODEL NUMBER SERIAL NUMBER

SOUTH EAST END EMERGENCY GENERATOR CUMMINS DSGAB H110239193 125KW

Fire Suppression

LOCATION (BLDG‐FLR‐RM)

EQUIPMENT

DESCRIPTION

QUANTITY MANUFACTURER MODEL NUMBER SERIAL NUMBER COMMENTS

DISTRIBUTED

THROUGHOUT THE

BUILDING

PORTABLE FIRE

EXTINGUISHERS

11 VARIOUS ABC 20 LBS

1st FLOOR SPRINKLER

CLOSET

WET PIPE SYSTEM CENTRAL SPRINKLER Co. 6 INCH RISER

PANEL LOCATED AT BLDG

ENTRANCE, DETECTORS

LOCATED THROUGHOUT

BUILDING

FIRE DETECTION ALARM

PANEL: FIRE / SMOKE

DETECTION, PULL

STATIONS & SPRINKLER

FLOW

GAMEWELL ZANS 400

LOCATION (BLDG‐FLR‐RM) WET DRY PRE ACTIVATION DELUGE D‐DRIP AIR COMPRESSOR ELECTRIC

NOSC‐BASEMENT/1 391 4 N/A N/A N/A N/A N/A

Emergency Lighting and Exit Signs

LOCATION (BLDG‐FLR‐RM)

EQUIPMENT

DESCRIPTION

ID MANUFACTURER MODEL NUMBER SERIAL NUMBER

DISTRIBUTED

THROUGHOUT BLDG

WALL MOUNTED

EMERGENCY LIGHTS

19 TYCO

DISTRIBUTED

THROUGHOUT BLDG

CEILING AND WALL

MOUNTED ILLUMINATED

EXIT SIGNS

16 TYCO

NOSC‐1‐STAIR 003 EMRGENCY LIGHTS 1

NOSC‐1‐103B EMRGENCY LIGHTS 3

NOSC‐1‐142 EMRGENCY LIGHTS 2

SECURITY GATES and

TURNSTILES

DESCRIPTION MANUFACTURER UNITS

ENTRY GATE 2

TURNSTILE 0

Overhead Doors Location Size Manufacturer

1 Room 103 (Gym) 7x14

EQUIPMENT TYPE UNITS MAKE MODEL # SERIAL #

SIZE OR

OUTPUT

AGE (YEARS) LOCATION

HVAC

Equipment

CHILLER CH1 1 DAIKIN AGZ060EPMVH-ER00 STNU150800110 55.8T OUTSIDE PAD

ENERGY

RECOVERY UNIT

1 RENEW AIRE HE4XINV C158269C 5HP 4000CFM

MAIN BUILDING,

MECHANICAL ROOM

AIR HANDLER AHU-

1 DAIKIN CAH022GDAM FBOU150401510 36T

MAIN BUILDING,

MECHANICAL ROOM

AIR HANDLER AHU-

1 DAIKIN CAH010GDAC FBOU150401433 15T

MAIN BUILDING,

BOILER ROOM

AIR HANDLER AHU-

1 DAIKIN LAH003A SLPD150500065 4T

MAIN BUILDING,

FITNESS ROOM

EXHAUST FAN EF-1 1 PENN BARRY SX085RC N/A 1/6HP BATHROOM 105

CIRCULATING

PUMP HOT WATER

P1

1 TACO 1641 NA 125 GPM 13 BOILER ROOM

CIRCULATING

PUMP HOT WATER

P2

1 TACO 1641 NA 125 GPM 13 BOILER ROOM

CIRCULATING

PUMP DOMESTIC

HOT WATER P3

1 TACO 1615B NA 16 GPM 13

BOILER ROOM

(CIRCULATING PUMP

FOR DOMESTIC HOT

WATER)

FUEL OIL PUMP P4 1 NA NA NA 1.5 GPM 13

BOILER ROOM (OIL

PUMP)

BOILER PUMP BP-1 1 TACO KV3006 N/A 1HP

MAIN BUILDING,

BOILER ROOM

HOT WATER

BOILER OIL FIRED

NO. B-1

1 WEIL-MCLAIN

PL488RWFBKLHLMASSC

SD1UL

SO#1401154292 24.7HP

MAIN BUILDING,

BOILER ROOM

HOT WATER

BOILER OIL FIRED

NO. B-2

1 WEIL-MCLAIN

PL488RWFBKLHLMASSC

SD1UL

SO#1401154292 24.7HP

MAIN BUILDING,

BOILER ROOM

WALL HEATER

UNIT (HOT WATER)

5 BEACON MORRIS W 82 NA 8 MBH 13

MAIN BUILDING,

HALL WAYS,

VARIOUS LOCATIONS

CABINET HEATER

UNITS (HOT

WATER) CUH-1

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP Corridor 108

CABINET HEATER

UNITS (HOT

WATER) CUH-2

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP Stairs 107

CABINET HEATER

UNITS (HOT

WATER) CUH-3

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP Vestibule 100

CABINET HEATER

UNITS (HOT

WATER) CUH-4

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP Stairs 122

CABINET HEATER

UNITS (HOT

WATER) CUH-5

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP Corridor 125

CABINET HEATER

UNITS (HOT

WATER) CUH-6

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP

Corridor 200 opposite Stairs 221

CABINET HEATER

UNITS (HOT

WATER) CUH-7

1 DAIKIN FHVH102 SIZE 2 NA 1/30HP

Corridor 200 opposite Stairs 222

HOT WATER

HEATER, OIL FIRED

(CONSIDERED A

BOILER)

1 BOCK 73E 06113017T67

80 GALLON 210

MBH INPUT

MAIN BUILDING,

BOILER ROOM

NOSC WRJ EQUIPMENT INVENTORY FOR PM PROGRAM

Johnson Controls – Series USD, Installed 2007

SERVICES: AHU-1, AHU-2, B-1, B-2 & B-3

ITEM NO. VCD CFM SIZE MANUFACTURER MODEL ROOM NO.

V-1 1-Jan 400 8” RD TRANE VAR1 TRAC 109 V-2 2-Jan 400 8” RD TRANE VAR1 TRAC 106 V-3 3-Jan 625 10” RD TRANE VAR1 TRAC 108, 110, 112, 113 V-4 4-Jan 300 6” RD TRANE VAR1 TRAC 103 V-5 5-Jan 400 8” RD TRANE VAR1 TRAC 114 V-6 6-Jan 800 12” RD TRANE VAR1 TRAC 102 V-7 7-Jan 400 8” RD TRANE VAR1 TRAC 101 V-8 8-Jan 200 6” RD TRANE VAR1 TRAC 116 V-9 9-Jan 450 8” RD TRANE VAR1 TRAC 119, 120, 121

10-Jan 590 10” RD TRANE 129, 130 11-Jan 250 6” RD TRANE 132, 133

V-10 1-Feb 1200 14” RD TRANE VAR1 TRAC CR-1 220

V 11A 2-2A 400 8” RD TRANE CR2 201

V 11B 2-2B 400 8” RD TRANE CR3 202

V 12A 2-3A 400 8” RD TRANE CR4 203

V 12B 2-3B 400 8” RD TRANE CR4 204

V-13 4-Feb 325 6” RD TRANE VAR1 TRAC 200, 219 V-14 5-Feb 500 8” RD TRANE VAR1 TRAC 217 V-15 6-Feb 400 8” RD TRANE VAR1 TRAC CR-6 205 V-16 7-Feb 620 10” RD TRANE VAR1 TRAC 206, 208 V-17 8-Feb 150 6” RD TRANE VAR1 TRAC 215 V-18 9-Feb 325 6” RD TRANE VAR1 TRAC 207 V-19 10-Feb 600 10” RD TRANE VAR1 TRAC 209 V-20 11-Feb 300 6” RD TRANE VAR1 TRAC 210

12-Feb 170 6” RD TRANE 218 13-Feb 150 6” RD TRANE 216 14-Feb 560 10” RD TRANE 200

DESCRIPTION

COVERAGE

OR COUNT

MANUFACTURER

AND MODEL

TYPE SIZE LOCATION

12 PORTABLE FIRE

EXT

12 UNITS VARIOUS ABC 20 LBS

DISTRIBUTED

THROUGHOUT

BLDG

SPRINKLER

SYSTEM

20000 SF

GLOBE FIRE

SPRINKLER

WET PIPE 6 INCH RISER

UNDER

STAIRWELL

FIRE

DETECTION/ALAR

M PANEL

20000 SF

FIRE CONTROL

INST. INC

FIRE/SMOKE

DETECTION, PULL

STATIONS &

SPRINKLER FLOW

24 ZONE

PANEL

LOCATED AT

BLDG

ENTRANCE,

DETECTORS

LOCATED

THROUGHOUT

ANSUL SYSTEM KITCHEN

KITCHEN HOOD RH-

1 BROAN QML MESS DECK 109

Emergency Lighting and Exit Signs

DESCRIPTION UNITS

MANUFACTURER

AND MODEL

TYPE LOCATION

EMERGENCY

LIGHTS

15 TYCO WALL MOUNTED

DISTRIBUTED

THROUGHOUT

ILLUMINATED EXIT

SIGNS

10 TYCO

CEILING AND WALL

MOUNTED

DISTRIBUTED

THROUGHOUT

Boiler and UPV Certification Dates

DESCRIPTION MANUF MODEL NO SERIAL NO CAPACITY YEAR LOCATION Last Cert Date

HOT WATER

BOILER OIL FIRED

NO. B-1

WEIL-MCLAIN

PL488RWFBKLHL

MASSCSD1UL

SO#1401154292

MAIN BUILDING,

BOILER ROOM

Mar-19

HOT WATER

BOILER OIL FIRED

NO. B-2

WEIL-MCLAIN

PL488RWFBKLHL

MASSCSD1UL

SO#1401154292

MAIN BUILDING,

BOILER ROOM

Mar-19

WHITE RIVER

JUNCT.

POTABLE WATER

SERVICE

CONBRACO NA 2 INCH

UNDER

STAIRWELL

EMERGENCY

GENERATOR

CUMMINS 125DSGAB

Elevator/Lift

DESCRIPTION UNITS

Hydraulic Lift – 20

FPM, 750lb Capacity Savaria

Backflow Devices

Emergency Generator

VOLUME CONTROL DAMPER SCHEDULE

VAV BOXES

FIRE SUPPRESSION

Size

1 9' x 8' Located in

Storage building

1 9' x 8' 1st Floor Rm

#135/136

Solar Panels

18 ea 280 Watt Solar Panels

Solar World Serial # SW280 MONO Located west roof

Overhead Doors