This synopsis announces an indefinite delivery/indefinite quantity contract for architect-engineer services for small projects in the Naval Facilities Engineering Command Mid-Atlantic area of responsibility. The contract will have a maximum value of $30 million over five years and support projects primarily at Joint Expeditionary Base Little Creek & Fort Story, Naval Station Norfolk, and Naval Air Station Oceana. Services include planning, design, construction support, and specialties like telecommunications, security, and audiovisual systems. Responses are due by May 9, 2019 and should include a completed SF330, past performance questionnaires for specified projects, and a draft small business subcontracting plan from large businesses. Evaluation criteria emphasize specialized experience, qualifications, past performance, quality control, management approach, and location. The small business size standard is NAICS 541330 with a threshold of $15 million.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N40085-19-R-9119 INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FOR

ARCHITECT-ENGINEER (AE) SERVICES FOR SMALL PROJECTS IN THE NAVFAC

MID-ATLANTIC AREA OF RESPONSIBILITY (AOR), LOCATED PRIMARILY AT

JOINT EXPEDITIONARY BASE LITTLE CREEK & FORT STORY (JEBLC-FS), NAVAL

STATION NORFOLK (NSN), AND NAVAL AIR STATION OCEANA (NAS OCEANA).

DESCRIPTION: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO

SUBMIT A STANDARD FORM (SF) 330, ARCHITECT ENGINEER QUALIFICATIONS IS

CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP)

PACKAGE TO DOWNLOAD.

This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for multi-discipline Architect-Engineer (AE) services for the Hampton Roads area of Virginia for NAVFAC MID-ATLANTIC. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, and FAR Subpart 36.6. The IDIQ contract term shall not exceed 5 years (60 months). The total fee for the contract term shall not exceed thirty-million dollars ($30,000,000). The guaranteed minimum for the contract term is five-thousand dollars ($5,000). The government shall negotiate Firm-fixed price task orders with the successful offeror. While the total cumulative cost of the contract shall not exceed $30,000,000, there will be no further dollar limit per task order and no further dollar limit per year.

Estimated start date is February 2020.

This solicitation is issued on an UNRESTRICTED basis. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code is 541330, Engineering Services, and the Small Business size standard is $15,000,000. The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria.

Most task orders issued under this contract will be for the design of project with construction costs of $5M or less with a significant number of projects between $1M - $5M in construction costs. Most projects will be renovation, repair, and minor new construction projects executed at the Public Works Departments in the Hampton Roads area.

Comprehensive AE services are required for planning, design, and construction services in support of new construction, renovations, repairs, replacements, demolition, alteration, and/or improvement of military and other governmental facilities to include base utility systems. AE services may include multiple disciplines or single disciplines, including but not limited to project manager, architectural, landscape architecture, structural, mechanical, electrical, civil, geotechnical, fire protection, cost engineering and interior design. Specialized services for telecommunications, physical security, audio-visual and collateral equipment may be required.

Facility types may include, but are not limited to, airfield pavements and associated infrastructure to include airfield lighting, waterfront facilities and associated infrastructure, base utilities, personnel housing facilities (Bachelor Enlisted Quarters (BEQ) and Bachelor Officers Quarters (BOQ), hospitality; office facilities (medical, training, secure facilities);

training facilities (operational, maintenance, and classroom); and industrial maintenance facilities (vehicle maintenance shops, shore intermediate maintenance activities, aircraft maintenance hangars, public works shops, and warehouses).

Specific types of AE services that may be required under this contract include:

A) Planning Services, including the development of project programming document (DD 1391), evaluations, site investigations, and cost estimation such as:

1) Facility planning services, including:

i) Project programming and requirements development

ii) Conceptual pricing development

iii) Development of Alternatives including Economic Analysis

2) Interior Space Planning Design and Collateral Equipment Inventories

3) Facility analysis, including:

i) General condition assessment including code compliance

ii) Energy utilization studies

iii) Facility life safety code analysis

iv) Exterior and interior hazardous material surveys and analysis

4) Site investigation services, including:

i) Geotechnical investigation in support of foundation design and site pavement recommendations

ii) Utility location/identification

iii) Site access studies including wayfinding and pedestrian corridors

iv) Site topographic and property boundary studies, including flood zones and wetlands

v) Environmental soil and ground water sampling and analysis

vi) Traffic analysis

vii) Storm Drainage analysis/studies

B) Design Services, including all supporting activities such as site investigation, surveys (to include hazardous material testing), design charrettes, cost estimates, etc.:

1) Development of design-build RFP packages including schematic concept drawings and environmental studies

2) Development of comprehensive design-bid-build packages that include full plans and specifications

3) Construction Cost Estimates

C) Construction Services such as the following services:

1) Contractor submittal reviews

2) Field consultation and special inspections

3) Electronic Operation and Maintenance Support Information (eOMSI)

4) Obtaining environmental permits and regulatory approvals

5) As-built and Record Document preparation

AE firms are required to prepare cost estimates utilizing the MCACES MII estimating system, specifications in the SPECSINTACT program, design-build RFPs utilizing NAVFAC Design- Build Masters, and drawings in AutoCAD (2016 or higher) or Revit (2016 or higher) utilizing the National CADD Standards format with NAVFAC specified modifications. 3D renderings and BIM modeling may also be required. AE firms or others under contract or providing services to NAVFAC may request software installation packages from NAVFAC Atlantic CI Cost. The AE is to send an email to NAVFAC-CI-Cost@navy.mil with the following in the Subject Section "MII License Request". Software is generally distributed to AEs free of charge; however, accompanying database licenses must be purchased and licensed as appropriate by the user.

Asbestos and or lead-based paint assessments may be required on this contract to determine the presence of hazardous material in existing facilities or at utility points of connections. When asbestos or lead is found, comprehensive asbestos or lead surveys, to include sampling and testing, and the preparation of plans and specifications showing the location of asbestos and lead, and specifying the procedure to be followed during construction and/or demolition for removal or abatement, will be required.

Work on and around waterfront structures, including under deck and underwater, and work in confined spaces may be required on this contract. AE firms must be able to accept work that involves asbestos, lead paint, PCBs, contaminated ground-water/soil and other hazardous materials, work on and under waterfront structures, on active airfields, and in confined spaces.

Registered Communications Distribution Designer (RCDD) may be required for telecommunication systems. Audio-visual systems may be required on this contract with services of Certified Technology Specialist-Designer (CTS-D). CTS-D whose certification is ANSI accredited under the International Organization of Standardization (ISO) and the International Electrotechnical Commission (IEC) ISO/IEC 17024 certification of personnel.

The Interior Designer qualification shall comply with UFC 3-120-10 Interior Design.

As defined by paragraph 1-5 of UFC 3-600-01, Fire Protection Engineering for Facilities, this contract will require the services of a licensed fire protection engineer or sub-consultant.

All engineering and design services shall comply with the most current edition of FC 1-300- 09N Navy & Marine Corps Design Procedures, and other requirements as indicated on the Whole Building Design Guide Web Site (www.wbdg.org). Selected AE firm is required to have online access to web-based support programs and email via the internet for routine exchange of correspondence/information. AE firm is required to submit and maintain an AE Accident Prevention Plan (APP) in accordance with USACE EM 385-1-1 for each project on this contract and Activity Hazard Analysis (AHA) for each in-field action. Key personnel, including sub-consultants, MUST be U.S. CITIZENS and able to obtain security clearances as required.

All contractors are advised that registration in System for Award Management (SAM) Database is required prior to award of a contract. Failure to register in the SAM Database may render your firm ineligible for award. For more information, check the SAM Web site:

https://www.sam.gov.

The awarded contract will be subject to specific provisions addressing the avoidance of organizational conflicts of interest, including NFAS 5252.209-9300, Organizational Conflicts of Interest. The prime firm for this contract will be required to perform throughout the contract term.

mailto:NAVFAC-CI-Cost@navy.mil https://www.sam.gov/

Interviews may be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to clarify information contained in the SF330 submittal. Elaborate presentations are not desired.

SELECTION CRITERIA:

Firms responding to this synopsis will be evaluated to determine the most highly qualified firm to perform the required services in accordance with the published selection criteria. Failure to comply with instructions, or provide complete information may affect the firm’s evaluation or disqualify the offeror from further consideration. Evaluation criteria (1) through (4) are considered most important and are equal among themselves; criteria (5-6) are of slightly less importance and are equal among themselves; criteria (7) is of the least importance and will be used as a tie-breaker among technically equal firms. Specific selection criteria include:

1. Specialized Experience

2. Professional Qualifications

3. Past Performance

4. Quality Control

5. Program Management, Location and Capacity

6. Commitment to Small Business

7. Volume of Work

Criterion 1- Specialized Experience (SF330, Part I, Section F):

Firms will be evaluated on specialized experience in performance of services similar to those anticipated under this contract through evaluation of experience in:

a) Designing and providing full construction drawings and specifications for various facility projects; including applying sustainability concepts through an integrated, cost effective design approach;

b) Prepare design-build RFP packages; including environmental surveys, geotechnical reports and schematic design concepts;

c) Experience preparing preliminary design deliverables such as concept plans, facility planning studies, including; developing facility requirements, preparing engineering evaluations, project scope, and unit guidance or parametric cost estimating;

d) Designing projects that demonstrate experience with Virginia codes, laws and permitting procedures;

e) Preparation of designs using AutoCAD or Revit; and

f) Providing construction phase services (shop drawing review, record drawings preparation, construction inspection services, and owner’s manuals)

Firms may be considered more favorably by demonstrating the following:

1. Guiding Principles for Sustainable Federal Buildings

2. Historic Preservation and Renovations; Experience with historic building repairs and renovations in accordance with the Secretary of the Interior’s Standards

3. Forensic Building Science & Investigations of materials, products, structures or components that fail or do not operate or function as intended

4. Experience designing projects to Navy or other DoD agencies criteria (such as:

UFC, ECB, Mil Stds., NAVFAC DB Master RFP templates, UFGS, etc.)

Submission requirements: Provide a minimum of three (3) and a maximum of six (6) projects completed within the past seven (7) years immediately preceding the date of issuance of this notice that best demonstrate specialized experience of the proposed team in the areas outlined above. Sufficient information to determine the date of completion the project must be included in the project description or the project will not be considered. Provide at least one example project demonstrating experience with historic repairs/ renovation with a construction cost over $2.5M. If more than the maximum number of projects are submitted, the Government will only evaluate the first six (6) projects in the order submitted.

All projects provided in the SF330 must be completed by the actual office/branch/regional office/individual team member proposed to manage and perform work under this contract.

Projects not meeting this requirement will be excluded from consideration in the evaluation. To enable verification, firms should include the DUNS number along with each firm name in the SF330 Part 1, Section F, block 25, “Firm Name” Include a contract number or project identification number in block 21. Include an e-mail address and phone number for the point of contact in block 23(c). In block 24, include in the project description the contract period of performance, date of project completion (MM/DD/YEAR), award contract value, current contract value, define professional service role and a summary of the work performed that demonstrates relevance to specialized experience as outlined above. For projects performed as a subcontractor or a joint venture involving different partners, specifically indicate the value of the work performed as a subcontractor or by those firms proposed for this contract, and identify the specific roles and responsibilities performed as a subcontractor or by those firms on the project rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project may be eliminated from consideration.

NOTE: If the firm is a joint venture, projects performed by both members of the joint venture should be submitted; however, if there are no projects performed by the joint venture, projects may be submitted for either member of the joint venture, not to exceed a total of six (6) projects, but greater consideration may be given where projects are demonstrated for the joint venture and/or both members of the joint venture.

Projects shall be submitted on the SF-330 at Part I, Section F and shall be completed projects.

Projects not completed will be excluded from evaluation consideration. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not submit an IDIQ contract as an example project. The Government will not evaluate information provided for an IDIQ contract. Submitted projects that do not conform to this requirement will not be evaluated.

NOTE: Date of project completion is defined as date of final design acceptance by client. For Full Design Projects, date of project completion is the date of final signed sealed plans & specifications to client. For DB RFP Preparation, date of project completion is the date of final

RFP documents submission. For DB RFP representing Contractor as DOR, date of project completion is the date of final design acceptance to client. For Design Development/DD1391 and Studies/Investigations, date of project completion is the date of final submission of design development/DD1391 and/or report. A project may not be considered if insufficient information is provided to clearly show the date of completion.

All information for Criterion 1 should be submitted in the SF330, Part I, Section F of the.

The Government WILL NOT consider information submitted in addition to Part 1, Section F in evaluation of Criterion 1.

Criterion 2- Professional Qualifications (SF330, Part I, Sections E & G):

Firms will be evaluated on professional qualifications, competence, and experience of the proposed key personnel in providing services to accomplish the tasks required under this contract, including participation in example projects as outlined in the SF330, Part 1, Section G.

Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Specific disciplines that must be included in key personnel are Project Managers, Quality Control Manager, Architects, Landscape Architects, Civil Engineers, Structural Engineers, Mechanical Engineers, Electrical Engineers, Geotechnical Engineers, Cost Engineers, Certified Interior Designers and licensed Fire Protection Engineers.

Submission Requirements:

SF330, Part I, Section E. Provide resumes for all proposed key personnel that illustrate experience in the work proposed under this contract. Resumes are limited to two (2) pages and should indicate: professional registration, certification, licensure and/or accreditation in appropriate disciplines; cite recent (within the past seven (7) years) project-specific experience in work relevant to the services required under this contract and indicate proposed role in this contract. At a minimum, resumes should indicate academic qualifications, professional licensure, supplemental training or certificates, and total years’ professional experience. State whether team members are U.S. Citizens. The AE shall indicate whether the key personnel hold a security clearance, and if so, at what level. Indicate participation of key personnel in example projects in the SF330, Part 1, Section G.

Criterion 3- Past Performance (SF330, Part I, Section H):

Firms will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS for Criterion 1 projects and may include customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. NOTE: Past performance information for projects listed under Criterion 1 may be given greater weight.

Submission Requirements:

SUBMIT A COMPLETED CPARS EVALUATION FOR EACH PROJECT UNDER

CRITERION 1. IF A COMPLETED CPARS EVALUATION IS NOT AVAILABLE, the Past Performance Questionnaire (PPQ) (Attachment (A)) included in this notice is provided for the firm or its team members to submit to the client for each project included under Criterion 1, Specialized Experience. DO NOT SUBMIT A PPQ WHEN A COMPLETED CPARS IS

AVAILABLE.

IF A CPARS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs should be submitted with your SF330. If the firm is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, firms should complete and submit with their responses the first page of the PPQ (Attachment (A)), which will provide contract and client information for the respective project(s). Firms may submit a PPQ previously submitted under a different Notice/RFP (legible copies are acceptable) as long as it is on the same form as posted with this Synopsis. Firms should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, Naval Facilities Engineering Command Mid-Atlantic Command, Code ACQ22, Attn: Stephen Astwood, Contract Specialist via email at Stephen.astwood1@navy.mil, prior to the response date. Firms shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A/E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation.

Firms may provide any information on problems encountered and the corrective actions taken on projects submitted under Criterion 1 Specialized Experience. Firms may also address any adverse past performance issues. Information shall not exceed two double-sided pages (or four single-sided pages) in total.

Awards, letters of commendation, certificates of appreciation, etc. shall not be submitted and will not be considered in the evaluation.

Criterion 4- Quality Control Program (SF330, Part I, Section H):

Firms will be evaluated on the strength of the quality control program proposed by the firm to ensure quality products and services under this contract, and means of ensuring quality services from their consultants/subcontractors. Maximum of 5 pages (one-sided) for Criterion 4 response. If an Offeror exceeds the page limit, the first 5 pages will be evaluated and pages after page 5 will not be evaluated.

Submission Requirements:

Describe the quality control program that will be utilized for all deliverables of this contract and the management approach for quality control processes and procedures. The description shall:

1. Explain the quality control program including an example of how the plan has worked for one of the projects submitted as part of SF330, Section F or how the plan will work if it has not been used previously.

mailto:Stephen.astwood1@navy.mil

2. Provide a quality control process chart showing the inter-relationship of the management and team components.

3. Describe specific quality control processes and procedures proposed for this contract including technical accuracy of and assurance of overall coordination of AE plans, specifications, and construction cost estimates.

4. Identify the quality control manager and any other key personnel responsible for the quality control program and a description of their roles and responsibilities.

5. Describe how the firm’s quality control program extends to management of subcontractors and specialty consultants.

Criterion 5- Program Management, Capacity and Firm Location (SF330, Part I, Section H):

Firms will be evaluated on the firm’s ability to plan for and manage work under the contract, the capacity to accomplish the work in the required time, and on the locations of their office(s) that will be performing the work under this contract and demonstrated knowledge of the primary geographic areas in which projects could be located. Greater consideration will be given for offerors with offices located in closer proximity to, or other demonstration that offerors will be able to perform quickly in, the geographic areas in which projects could be located. Maximum of 5 pages (one-sided) for Criterion 5 response. If an Offeror exceeds the page limit, the first 5 pages will be evaluated and pages after page 5 will not be evaluated.

Submission Requirements:

1. Provide an organizational chart for the team and discuss the management plan for this contract and personnel roles in the organization. Describe the ability of the firm to manage, coordinate and work effectively with team members, both internal staff and consultants. Discuss the history of working relationships with team members, including joint venture partners where applicable.

2. Describe the firm’s present workload and the availability of the project team (including consultants) for the specified contract performance period. Describe the workload/availability of the key personnel during the anticipated contract performance period and the ability of the firm to provide qualified backup staffing for key personnel to ensure continuity of services. General statements of availability/capacity may be considered less favorably.

3. Provide the location of the office(s) that will be performing the work, including main offices, branch offices, and offices of team members. Evaluation of firms will include consideration of their location within the primary geographic area of the anticipated projects, primarily in the Hampton Roads region of Southeastern Virginia. Provide examples demonstrating team’s knowledge of the primary geographic areas in which projects could be located.

Criterion 6—Commitment to Small Business (SF330, Part I, Section H):

Firms will be evaluated in terms of the extent to which they have identified and committed to Small Business (SB), Small Disadvantaged Business (SDB), Women-Owned Small Business (WOSB), Historically Underutilized Business Zone Small Business (HUBZoneSB), Veteran- Owned Small Business (VOSB), Service Disabled Veteran Owned Small Business (SDVOSB), and if applicable, Historically Black Colleges or Universities and Minority Institutions (HBCU/MI) in performance of this contract, whether as a joint venture, teaming arrangement, or subcontractor. The Government will evaluate proposals based on: (A) Past performance in utilization of small business concerns, and (B) Participation of small business concerns for this requirement. In support of (A), all firms shall provide historical data on utilization of SB, SDB, WOSB, HUBZoneSB, VOSB, SDVOSB and HBCU/MI. Large Businesses shall submit three “final” or “most recent” Individual Subcontracting Reports (ISRs) for similar contracts of relative size which show compliance with utilizing the various types of small business firms noted above. If ISRs are not FINAL or MOST RECENT they will not be considered. If subcontracting goals were not met, provide an explanation. If Individual Subcontracting Reports were not applicable to the similar contracts noted, large businesses shall submit other documentation which shows their utilization of the various types of small business firms for the contracts. Small Businesses shall also submit documentation which shows their utilization of the various types of small business firms for similar contracts of relative size. In support of (B), large businesses shall submit a draft Small Business Subcontracting Plan, in which they will be evaluated on the extent to which they identify and commit to the published Small Business Subcontracting Program. NAVFAC has assigned goals for FY2019 in terms of percentages of total planned subcontracting dollars for utilization of small businesses. Demonstrate the plan to meet these goals:

SB 45%

HubZone 3%

SDB 5%

WOSB 15%

SDVOSB 5%

VOSB 5%

If a large business firm is selected for award, a Small Business Subcontracting Plan, in accordance with FAR 19.7 and DFAR 219.7, will be required and incorporated into the contract award. A draft Small Business Subcontracting Plan is not required from small businesses;

however, small businesses shall submit similar information on the extent to which they identify and commit to subcontracting to large business (LB), SB, SDB, WOSB, HUBZoneSB, VOSB, SDVOSB, and HBCU/MI if applicable in the performance of this contract.

The Small Business size standard classification is NAICS (541330 NAICS Code), (Engineering Services), size standard ($15,000,000).

The attached Small Business Subcontracting Plan template (Attachment (B)) shall be used by large businesses to complete the draft subcontracting plan. Firms shall submit their “draft” Small Business Subcontracting Plans utilizing this template, and ONLY this template.

Criterion 7—Volume of Work (SF330, Part 1, Section H)

Firms will be evaluated in accordance with DOD Federal Acquisition Regulation Supplement (DFARS) Procedures, Guidance and Information (PGI) 236.602-1, from data extracted from the Federal Procurement Data System (FPDS). Firms will be evaluated in terms of work previously awarded to the firm by DOD within the past twelve months with the objective of effecting an equitable distribution of contracts among qualified A&E firms including small, disadvantaged business firms, and firms that have not had prior DOD A&E contracts.

Submission Requirements:

Firms do not submit data for this factor.

SF-330 SUBMISSION REQUIREMENTS:

Architect-Engineer firms desiring to be considered for this contract must submit a completed SF-330 package. The SF-330 shall be typed, one sided, at least 11 point Times New Roman or larger. Part I shall not exceed (50) single-sided 8.5 by 11 inch pages (the page limit does not include ISRs, certificates, PPQs, licenses, or the draft subcontracting plan, as required by the Small Business Subcontracting criterion, nor does the page limit include cover sheets, dividers, or other requested documentation (e.g., joint venture agreement, proof of AE firm registration) provided that these do not contain any substantive information submitted in response to the synopsis or intended to demonstrate the qualifications of the firm). Part I pages shall be numbered sequentially. The organizational chart may be one-page single sided 11 by 17 foldout, using 11-point font or larger (font limitations do not apply to graphics, captions or tables). Please include your DUNS and CAGE numbers in Block 30 of the SF-330.

**In accordance with the FAR 36.601-4(b) contracts for architect-engineer services may only be awarded to firms permitted by law to practice the professions of architecture or engineering.

Firms must submit proof that they are permitted by law as required by FAR 36.601-4(b). If a firm is in a jurisdiction that requires AE firm registration, the firm must provide proof of registration. If a firm is in a jurisdiction that does not require AE firm registration, the firm must provide proof eligibility to practice (e.g., a summary explaining eligibility under the laws of that jurisdiction). Failure to submit the required proof could result in a firm’s elimination from consideration.

**Firms who are offering as a joint venture should include with their submission a copy of the joint venture agreement. Failure to include the joint venture agreement may result in the firm’s elimination from further evaluation.

Architect-engineer firms that meet the requirements described in this announcement are invited to submit (4) of the SF-330 and (2) CDs with searchable bookmarks to Naval Facilities Engineering Command (Mid-Atlantic Command), Code (ACQ22), Attn: Stephen Astwood, 9324 Virginia Ave., bldg. Z140, Room 255, Norfolk, VA. 23511-3095. Firms responding to this announcement by May 9, 2019 at 2:00 p.m. (EDT) will be considered. THIS IS NOT A

REQUEST FOR PROPOSAL.

Late responses will be handled in accordance with FAR 52.215-1. The points of contact are either Stephen Astwood, Contract Specialist, at stephen.astwood1@navy.mil or Holly Manning, Contract Specialist, at holly.manning@navy.mil.

If an SF 254/SF 255 is submitted for this solicitation, it will not be reviewed or considered. As required above, provide verifiable evidence that your firm is permitted by law to practice the professions of architecture or engineering (e.g., state registration number).

mailto:stephen.astwood1@navy.mil mailto:holly.manning@navy.mil

If hand-carrying or express mailing proposal, the firm is advised that the Contracting Officer is on a secured base and passes are required to enter the base. Anticipate delays in base access and plan accordingly. Hand-carried proposals must be delivered to the Contracting office.

Government personnel will not pick up proposals at the gate. It is the contractor’s responsibility to ensure delivery to the location specified.

All visitors to Naval Station Norfolk who do not have a CAC badge or DBIDS badge must have a background check run by the Naval Station Pass & ID office (Security Department at Commander, Naval Region Mid-Atlantic).

Prospective visitors who do not have a CAC or DBIDS badge must complete the attached SECNAV 5512/1 form (Attachment C). The attachment must be fully completed, signed, and shall be sent to Stephen Astwood, Contract Specialist, via email at stephen.astwood1@navy.mil. Visitors must complete and provide the attached form at least 14 business days prior to their scheduled meeting date to allow ample time to process and complete the background check.

Commercial couriers such as FEDEX, DHL or UPS follow the same visitor procedures listed above and they are required to have a background check if they do not have a CAC badge or DBIDS badge. Commercial couriers must also have their vehicle inspected at location prior to entry.

Firms should check with their intended courier to ensure they have the proper identification credentials to access Naval Station Norfolk.

Temporary visitor passes must be picked up by the approved visitor from the Naval Station Pass and ID Office located at the following address prior to visiting NAVFAC Mid Atlantic:

Address: Naval Station Pass and ID Office 9040 Hampton Blvd Norfolk, VA 23505 Telephone Number: 757-322-2975 Hours of Operation: 0600-1700 on Monday through Friday

Electronic (E-mail, facsimile, etc.) submissions are not authorized.

Inquiries concerning this procurement should include solicitation number and title and be forwarded via email to stephen.astwood1@navy.mil.