Bulk Asbestos Analytical Report
10/14/2020
ISO/IEC 17025 NVLAP Accredited
〒101-0051 2-2-31 Kanda-Jimbocho
Hulic Jinbocho Building 3F Chiyoda-ku, Tokyo, Japan
TEL : 03-3263-6055
URL : http://efa.co.jp
NVLAP Code 500068-0
EnviroQuest Inc.
Asbestos Test B926
Tokyo Labor Bureau Registered Lab(13-93)
Final Report
Bulk Asbestos Analysis
Report Number:
Date Received:
Date Printed:
First Reported:
Date Analyzed:
B101206 10/9/2020
10/14/2020
Site Name: Job ID:Asbestos Test B926 10006-16
Lab Number Asbestos
Type Percent in
Layer Asbestos AsbestosPercent in
Type TypeLayer
(Modified EPA Method 600/R-93-116)
EnviroQuest Inc.
Sample ID Layer Percent in
10/14/2020
10/14/2020
92601 10108760
Layer: White Drywall ND56% Layer: Tan Paper ND10% Layer: Beige Joint Compound Chrysotile Tremolite2 % Trace7% Layer: White Paint ND10% Layer: White Non-Fibrous Material ND7% Layer: White Paint ND10%
Asbestos (Trace)Total Composite Values of Fibrous Components:
Cellulose (5 %) Wollastonite (3 %) Talc (1 %) Comment:
Collected on 9/17/2020
92602 10108761
Layer: Tan Fibrous Material ND100%
Asbestos (ND)Total Composite Values of Fibrous Components:
Cellulose (90 %) Comment:
Collected on 9/17/2020
Notes: (1) Limit of Detection exceeds 0.1%. 'Trace' denotes Gravimetric Point Count or TEM analysis required for quantification. 'ND' = 'Not Detected (less than 0.1%)' (2) The results relate only to the items tested. (3) The test report shall not be reproduced, expect in full, without written approval of the laboratory. (4) The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.
Ayako Ozawa, Laboratory Manager
EFA Laboratories, Ltd Tel: 03-3263-6055 Fax: 03-3263-60562-2-31 Kanda Jimbocho Hulic Jimbocho Bldg. 3F, Chiyodaku Tokyo info@efa.co.jp
Analytical Flow adopted in EFA Laboratories
Point count analysis for
1000 points after gravimetric reduction.
Calculate asbestos content based on asbestos points counted and results of gravimetric reduction
End of analysis:
Calculate asbestos content with visual estimation.
Optional analysis using TEM
(transmission electron microscope): TEM can be used for samples with very low content of asbestos and/or small fiber size.
End of Analysis: Reported as None detected (guarantee asbestos <0.1%)
No asbestos detected
Determine asbestos fiber presence using PLM (Polarized Light Microscope).
(Identify asbestos fiber based on sign of elongation, extinction angle, dispersion staining color, pleochroism and morphology)
Asbestos ≧1% Asbestos <1%
Asbestos present
Visual estimation of asbestos content under PLM