This document is a Quality Assurance Surveillance Plan (QASP) for a sanitary tank cleaning contract at Portsmouth Naval Shipyard. The contract involves cleaning and sanitizing sanitary tanks aboard a US Submarine while in dry dock, with a performance period from March 3, 2026 to June 2, 2026. The QASP outlines detailed performance objectives, surveillance methods, and specific acceptance criteria for the contractor, including strict requirements for personal electronic device prohibitions, tank cleaning standards, disinfection processes, bacteriological testing, and waste disposal.
The plan includes rigorous performance standards with associated risk levels, ranging from low to high, and potential consequences for non-compliance such as corrective action reports, negative contractor performance assessments, work stoppages, financial penalties, and potential contract termination. Key performance requirements include maintaining zero tolerance for personal electronic devices, achieving specific cleanliness standards (SSPC-SP 1), conducting proper disinfection with precise chemical quantities, ensuring bacteriological test results meet EPA standards, and maintaining strict safety protocols including marine chemist certification, proper ventilation, and personal protective equipment usage.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N3904026Q2982 Attachment 2- Wage Determination 2015-4011.pdf | ||
| N3904026Q2982 Exhibit A.pdf | ||
| N3904026Q2982 Attachment 1- OPSEC Encl 2_Redacted.pdf | ||
| N3904026Q2982 Combined Synopsis Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| The contractor’s failure to comply with these requirements may result in but are not limited to: |
| 1. If the Contractor fails to meet the performance standards, the COR/KO will issue a Contractor Deficiency Report (CDR) and/or a Corrective Action Request (CAR). The Contractor will be required to submit a corrective action plan within 7 days days outlining the steps that will be taken to address the deficiency and prevent recurrence. |
2. Negative CPAR Ratings that can affect future awards
3. Contract Termination (as last resort) In extreme cases of persistent and significant failures.
| Performance Objective/Requirement (From SOW Section) | Method of Surveillance | Frequency of Surveillance | Acceptance Criteria | Performance Standard | Incentive/Disincentive | Risk Level (H/M/L) |
| 2. PEDs Prohibition | Visual Observation, Unannounced Spot Checks | Sporadic | No personal electronic devices with cameras are present on site or aboard the submarine. No PEDs of any kind present on submarines. | Zero tolerance. No cameras or PEDs permitted | Personnel removed. | H |
| 2.3.2 No Damage to Tank Structure | Visual Inspection | After Cleaning, During PNS Inspection | No damage to underlying paint, tank structure, hangers, piping, hinges, TLI. | Structure intact. | Contractor responsible for repair. | M |
| 2.3.3 Cleanliness Standard SSPC-SP 1 | Visual Inspection | During PNS Inspection | Tanks cleaned to SSPC-SP 1 standard. No loose wastes, grease film, or flaking paint. | Acceptable visual appearance | Rework at Contractor's expense. | M |
| 2.4.1 Notification of Disinfectant Addition | Communication Verification | 24 hours prior to sanitization | Evidence of notification of PNS Project Management and Inspector. | Timely notification | Work stoppage until proper notification occurs. | M |
| 2.4.2 Disinfection Process Adherence | Observation (PNS Inspector) | During Sanitization | Correct amount of disinfecting solution used (17.5 gallons of 5% or 8.8 gallons of 10% sodium hypochlorite). Correct fill levels maintained. Soak time of 4 hours. Rinsing/washdown performed correctly. HWAA emptied on time. | Exact adherence to steps and quantities | Rework required if non-compliant | H |
| 2.5.1 Bacteriological Testing | Document Review | After Sanitization/Disinfection | Samples taken correctly. Runoff at bottom of tank used. | Runoff from all parts of tank | Retesting required if incorrect | M |
| 2.5.3 Bacteriological Test Results | Document Review | Prior to PNS Inspection | Certified copies of test results submitted to PNS personnel (Project Management, COR, Inspector, TPOC) before PNS inspection. Density of E.COLI must be less than 235 / 100 mL. Density of ENTEROCOCCI must be less than 61 / 100 mL. | Test results meet EPA standards. | Rework required if test fails | H |
| 2.6.1 Tank Inspection by PNS | PNS Inspection | After Contractor Cleaning | Tank cleanliness accepted by PNS Inspector or Structural Engineer TPOC. | PNS Inspectors acceptance of cleanliness | Rework at Contractor's expense. 5% penalty per tank failure | H |
| 2.7.1 Anode Removal & Turnover | Visual Inspection & Turnover Verification | If Required, Before Cleaning | Anodes, if present, removed and turned over to PNS project personnel. | All anodes removed | Delay in cleaning until removed. | L |
| 2.8.1 Marine Chemist Certification | Document Review & Visual Posting | Before Tank Entry | Valid Marine Chemist Certification posted outside the tank. | Certification posted. | Work stoppage until certified. | H |
| 2.8.2 Ventilation | Observation & Document Review | During all phases of cleaning | Ventilation is sufficient and exhausts outside the ship without recirculation. Conforms to confined space certificate. | Adequate ventilation in place. | Work stoppage until ventilation meets requirements. | H |
| 2.8.3 PPE Usage | Visual Observation | During Work | Contractor personnel wear appropriate PPE (respiratory protection, gloves, boots, body protection, eye/face/head protection). | 100% PPE compliance | Personnel removed until compliant. | H |
| 2.8.6 Waste Disposal | Document Review & Spot Checks | After disposal of waste | Proper disposal methods used in accordance with all applicable federal, state and local regulations. Approval from PNS Environmental Engineer Department. | Regulations adhered to. | Financial penalties/legal action. | H |
| 2.8.7 Waste Storage | Visual observation | During work. Random | Hazardous materials/waste not stored on board longer than 1 hour without contractor personnel present. | No long-term storage of waste | Work Stoppage. Non-compliance. | H |
| 2.8.8 Spill Response | Visual observation | After incident. Random | Spill properly cleaned up immediately. Notifications made to PNS Project Management Team and Navy Faire and Emergency Services. | No spills left unattended | Contractor is financially responsible for any clean-up costs | H |
| 2.8.9 Work Area Protection | Visual observation | During work. Random | Work area protected with waterproof cover-up to prevent spills/splashes. Area kept clean of trade litter. | Adequate work area protection | Work stoppage and cleanup required. | H |
| 4.3 Coordination with PNS Project Team | Communication Verification | Daily | Contractor coordinates work daily with PNS Project Management Team. | Demonstrated communication | Schedule delays | M |