Question and Answer 9-18.pdf
PDF 58 KB Posted
- Attached to
- Rental of one (1) 400 CFM Low Pressure Air Compressor Naval Base New London, Groton, CT- NLON
- Solicitation number
- N3904025Q3054
About this file
This document is a Questions and Answers (Q&A) file related to a technical specification for equipment. The vendor asked two clarifying questions about potential equipment modifications: (1) whether a 125HP LPAC (Low Pressure Air Compressor) could be used instead of a 100HP LPAC, provided electrical requirements are maintained, and (2) whether a 660 Gallon tank could replace a 500 Gallon tank while ensuring all requirements are met. The Technical Point of Contact responded affirmatively to both questions, with the additional stipulation that the compressor must be oil-free.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N3904025Q3054 Combined Synopsis.pdf | ||
| N3904025Q3054 Attachment - 1 OPSEC Enclosure 2_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vendor Questions:
-Are we able to use a 125HP LPAC instead of a 100HP LPAC as long as we remain in the Electrical Requirements?
-Are we able to use a 660 Gallon tank instead of a 500 Gallon as long as we ensure the requirements are met?
Technical Point of Contact Answers:
Yes to both questions but compressor must be oil free.
File details come from the government source that posted it. Updated .