REQ DOC NO. - 8113V005 ATTACHMENT

CONTINUATION SHEET CONTRACT NO. - PAGE

OF

NAME OF OFFER OR/CONTRACTOR

ITEM # SUPPLIES/SERVICES QTY U/I

TANK 2 EACH

C. DESCRIPTION/SPECIFICATIONS.

C.1 TANK, HORIZONTAL, CYLINDRICAL, 316 STAINLESS STEEL

STORAGE TANK, 5000 GAL NOMINAL CAPACITY, DESIGN PRESSURE

FULL VAUUM. 200OF MAX DESIGN TEMPERATURE. -20OF MIN

DESIGN TEMPERATURE. VESSEL HYDRO PRESSURE 20 PSIG FOR 30

MINUTES. FINAL INTERIOR FINISH OF 125 MICRO INCHES RA., SEE

ATTACHES SPECS

C.1.1 ENGINEER REQUESTS CERTIFICATION OF COMPLIANCE AND

HYDROSTATIC TEST BE EMAIL.

C.2 C528 SPECIFICATION CHANGES.

C.3 C500 MERCURY CONTROL.

C.4 DATA REQUIREMENTS PER EXHIBIT A (DD-1423) & ATTACH #1.

C.4.1 CERTIFICATE OF COMPLIANCE; EXHIBIT A SEQUENCE A001.

C.4.2 HYDROSTATIC TEST CERTIFICATION, EXHIBIT A SEQUENCE

A002.

D. PRESERVATION/PACKAGING/PACKING.

D.1 D4 PREPARATION FOR DELIVERY (COMMERCIALLY PACKAGED).

E. INSPECTION AND ACCEPTANCE.

E.1 E2 INSPECTION AND ACCEPTANCE (DESTINATION).

E.2 G505 VENDOR DISPOSITION OF NON CONFORMING MATERIAL.