The contract opportunity is for a Firm Fixed Price contract to perform the work in accordance with work package HRMC-511-24. The tentative Period of Performance is 17 June 2024 to 31 July 2024. The solicitation number is N32253-24-Q-0051, and proposals are due on 3 June 2024 at 1000 HST. The applicable NAICS code is 336611 with a size standard of 1,300 employees, and the Product Service Code is J020 Maintenance, Repair, and Rebuilding of Ship and Marine Equipment. The work may require either the removal and replacement of a single strand of fiber, or the removal and replacement of 5 strands, depending on whether obstructions can be cleared. Fusion splicing and light duty connectors will be required. The current BOF cable is manufactured by General Cable. Contractors will be responsible for providing the necessary materials.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLOWN OPTIC FIBER (BOF) CABLE Questions and Answers
As of 5/31/2024
Question: How many strands of fiber are being Blown in?
Answer:
Depends: Per PWS para 3.1.5, if able to clear obstruction, one strand would be removed from its current position and that strand would be blown in to the now-unobstructed path. If unable to clear obstruction, per PWS para 3.1.6, 5 ea. strands would need to be removed, a new BOF cable needs to be installed, then 5 ea. strands blown in to the new BOF cable.
Question: Fusion splicing / light duty connectors?
Answer:
Per PWS para 3.1.4, the run goes from a FIB to a FIB, so fiber will need to be spliced at each end.
Question: Is the current BOF SUMITOMO or BLOWLITE? “This can affect the speed of blowing in fiber”
Answer:
Per PWS reference 1 parts list, the 7 tube cable is built to M85045/25-01E (higher level doc is MIL- PRF85045/25). Per recommended components lists (QPDSIS 85045 120625.pdf(dla.mil) and QPDSIS 85045 120625.pdf(dla.mil)), the manufacturer is General Cable
Question: Will material be provided?
Answer:
Per PWS paragraph 3.0 Note 1, contractor to provide material.