This document contains a request for proposal for a firm fixed-price contract to perform overhaul work on an 85-foot Torpedo Weapons Retriever. Key details include that the Pearl Harbor Naval Shipyard and Intermediate Maintenance Facility is seeking proposals to perform work in accordance with work package HRMC-HM&E-22-0032, with a period of performance from September 30, 2022 to September 29, 2023. Proposals are due by September 19, 2022 at 0900 HST and shall be emailed to the primary and secondary points of contact listed. A ship check is being offered on August 23, 2022 at 0900 HST at the S1 Boathouse, with RSVPs due by August 22, 2022. The solicitation number for this requirement is N32253-22-R-0016.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers

Question:

1. Does the Government have a recommended source for the Cruisair Technical Representative for work item 514‐31‐001, as paragraph 3.6 implies that manuals and product specification sheets that tend to be proprietary be turned over to the Supervisor at completion of work? Paragraph

3.6 appears to contradict paragraph 3.1 which only requires a Qualified Marine HVAC Technician to complete the work.

Answer:

The GOVERNMENT does not have a recommended source. Please bid accordingly.

2. WI 514‐11‐001 lists CFW piping, ¾” IPS (composite) but lists 009‐12 Col A Lines 1‐10 for inspection. Is the CFW a typographical error?

Yes ‐ Typo, it is not CFW.

3. WI 529‐11‐001 lists 1.3.1 as aluminum, 1.3.2 and 1.3.3 lists carbon steel. The referenced drawings do not show carbon steel. Is the material listed in the WI correct?

No, it is not carbon steel, appears to be all aluminum.

4. Work item 311‐21‐001, Generator Inspection, Repair and Service, para. 3.5.5 Calls to

“Disassemble, clean, inspect and test windings and regulators using 2.2 through 2.5 and OEM overhaul manual”. This is a service not provided by the qualified “known source”. Is it the government’s intent to overhaul the generator end and if so would it be IAW NavSea Std. Item

009‐17?

No, do it per the specs. Find source that can do it per the specs.

5. For WI 233‐14‐001 Flexible Hose; Inspect, Test and Replace; to properly estimate the hose replacement, is the Government able to provide type, fitting size, hose diameter and length of the hoses requiring replacement?

No.

6. WI 110‐11‐001 Exterior & Interior Hull; Inspect and Repair. Removal and installation of bulkhead plating in paragraphs 3.2.1 and 3.2.2 are based on the UT report from paragraph 3.1.1. Since exact locations are not known prior to this report, will major interferences be the subject of a

CFR, or should the Contractor cover unknown interferences in its quote?

Yes.