Q&A_11_-_15.doc
DOC document 49 KB Posted
- Attached to
- USNS CITY OF BISMARCK PSA/DD
- Solicitation number
- N3220518R4101
About this file
Questions and Answers 11 - 15
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BISMARCK_Amendment_N3220518R4101-0009.docx | DOCX document | |
| BISMARCK_Amendment_N3220518R4101-0008.docx | DOCX document | |
| BISMARCK_PSA-DD_Amendment_N3220518R4101-0007.docx | DOCX document | |
| BISMARCK_Amendment_N3220518R4101-0006.docx | DOCX document | |
| BISMARCK_Amendment_N32205-18-R-4101-0005.docx | DOCX document | |
| Amendment_N32205-18-R-4101-0004.docx | DOCX document | |
| Amendment_N32205-18-R-4101-0003.docx | DOCX document | |
| RFP_Q&A_5,_7_-_9.doc | DOC document | |
| Amendment_N32205-18-R-4101-0002.docx | DOCX document | |
| RFP-_Q_&_A_1_-_4_&_6.docx | DOCX document | |
| J_-_1_Work_Item_Index_Rev_1.pdf | ||
| Amendment_N32205-18-R-4101-0001_BISMARCK.docx | DOCX document | |
| JA_N32205-18-R-4101BISMARCK_PSA_(Posted).pdf | ||
| J_-_Attachments.zip | ZIP file | |
| Solicitation_-_CITY_OF_BISMARCK_N32205-18-R-4101.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USNS CITY OF BISMARCK (T-EPF 9)
N32205-18-R-4101
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: WI 803
PARAGRAPH / SECTION NO: _N/A_____
TITLE: MISSING INFORMATION REFERENCES
QUESTION 11:
Information referenced in the Work Item 0803 and was not supplied with the RFQ:
1. HVAC Piping Mod. .PPT
2. Keckly Duplex Strainer .PDF
3. Leslie Navy Strainer .PDF
ANSWER:
References 1 and 2 no loger apply to WI. Reference #3 provided via AMRDEC.
SPECIFICATION ITEM NO.: 0206
PARAGRAPH / SECTION NO: _2.1_
TITLE: LINE SHAFT BEARING ANNUAL MAINTENANCE
QUESTION 12:
Please provide following references:
2.1 NAVSEA TM S9243-CR-MMC-010
ANSWER:
Reference provided via AMRDEC.
SPECIFICATION ITEM NO.: 905
PARAGRAPH / SECTION NO: _7.2.3
TITLE: REMOVE AND INSPECT WATERJET
QUESTION 13:
Line item 7.2.3 needs changing as, per Wartsila Qualified Technical Representative, to:
7.2.3 The Water Lubricated Bearing readings shall be taken once the water jet assembly has been removed from the ship using micrometers at the 12:00, 3:00, 6:00 and 9:00 (o-clock) positions per the O.E.M. instruction.
ANSWER:
Concure with Wartsila Quailified Techincal Repersentative to correct the wording of the line item to read as suggested; 7.2.3 shall be worded as follows:
….from the ship using mircometers (vice feeler gauge) at the 12:00, 3:00, 6:00, and 9:00 (o-clock) positions……
This correction is found to be technically acceptable as it was recommended by the OEM.
SPECIFICATION ITEM NO.: 504
PARAGRAPH / SECTION NO: _7.1
TITLE: PERFORM ANNUAL MAINTENANCE OF MSD VACUUM
QUESTION 14:
Contractor can not get a quote from the required OEM authorized field Technical Service Representatives listed in the specs because EVAC referred me to Green Marine & Industrial Equipment Co, and they don’t have any of the references listed in 2.0 therefore they haven’t given me a quote. Are there any other OEM authorized field Technical Service Representatives that can be used?
ANSWER:
References provided via AMRDEC, Only an Authroized Original Equpiment Manfacture’s representative or an authorized representative can be used to perform the work required in this item.
SPECIFICATION ITEM NO.:
All
PARAGRAPH / SECTION NO:
All
TITLE: Request for Extension of solicitation.
QUESTION 15:
Due to delays being encountered receiving priced proposal from some of the OEMs and the delays in availability of referenced documents, Gulf Copper is requesting a 10 day extension on the deadline for the submittal of the this offer.
ANSWER:
Due to the delays in providing referenced documents an 8-day extension will be granted.
ATTACHMENT J - 8