RFC_018_-_I_503_Breaker_information.doc

DOC document 41 KB Posted

Attached to
USNS HENRY J KAISER MTA Federal contract opportunity
Solicitation number
N32205-17-R-4008
Issued by
Department of the Navy Military Sealift Command

About this file

RFC 18

View the file

Other files for this federal contract opportunity

Other files attached to USNS HENRY J KAISER MTA, newest first.
File Type Posted
Amendment_0006_for_USNS_KAISER_N32205-17-R-4005.pdf PDF
Amendment_0005_for_USNS_KAISER_N32205-17-R-4005.pdf PDF
RFC_024_J-8_Request_for_Spec_Clarification_WI_615.pdf PDF
RFC_024_J-8_Request_for_Spec_Clarification_WI_615.pdf PDF
J-8_Request_for_Spec_Clarification_WI_107a.doc DOC document
J-8_Request_for_Spec_Clarification_WI_511a.doc DOC document
Amendment_0002_N3220517R4008.docx DOCX document
RFC_014_-_I_106_Superstructure_side.doc DOC document
RFC_016_-_I_106_Superstructure_Steel_locations.doc DOC document
RFC_015_-_I_107_WT_Door_quantity.doc DOC document
RFC_019_-_I_306_Missing_Drawings.doc DOC document
J-8_Request_for_Spec_Clarification_WI_511.doc DOC document
J-8_Request_for_Spec_Clarification_WI_614.doc DOC document
J-8_Request_for_Spec_Clarification_WI_107.doc DOC document
J-8_Request_for_Spec_Clarification_WI_514.doc DOC document
J-8_Request_for_Spec_Clarification_WI_613.doc DOC document
J-8_Request_for_Spec_Clarification_WI_202.doc DOC document
J-8_Request_for_Spec_Clarification_WI_516.doc DOC document
J-8_Request_for_Spec_Clarification_WI_512.doc DOC document
J-8_Request_for_Spec_Clarification_WI_515.doc DOC document
J-8_Request_for_Spec_Clarification_WI_109.doc DOC document
J-8_Request_for_Spec_Clarification_WI_508.doc DOC document
N32205-17-R-4008_AMENDMENT_0001.docx DOCX document
CDRL,_SWI-004.pdf PDF
CDRL,_SWI-001.pdf PDF
CDRL,_SWI-0020.pdf PDF
CDRL,_SWI-0022.pdf PDF
J-13__PAST_PERFORMANCE_QUESTIONNAIRE.docx DOCX document
N3220517R4008.pdf PDF
J-10_Interport_Differential.doc DOC document
J-14_NON_DISCLOSRE_AGREEMENT_FOR_GOVN'T_TECHNICAL_DATA.pdf PDF
CDRL,_SWI-0018.pdf PDF
J-9_Disclosure_of_Lobbying_Activities_SF-LLL.pdf PDF
CDRL,_SWI-0012.pdf PDF
CDRL,_SWI-0019.pdf PDF
J-8_Request_for_Spec_Clarification.doc DOC document
CDRL,_SWI-0017.pdf PDF
CDRL,_SWI-0021.pdf PDF
CDRL,_SWI-0014.pdf PDF
CDRL,_SWI-006.pdf PDF
CDRL,_SWI-0010.pdf PDF
J-7_MSC_Ship_Repair_Facility_Survey.doc DOC document
J-12_Past_Performance_Data.docx DOCX document
J-2Category_A_Items.xls XLS spreadsheet
J-3_CAT_B_ITEMS.xlsx XLSX spreadsheet
CDRL,_SWI-0015.pdf PDF
JA_17-R-4008_Redacted.pdf PDF
CDRL,_SWI-0024.pdf PDF
CDRL,_SWI-0016.pdf PDF
CDRL,_SWI-0013.pdf PDF
Show all 50

USNS HENRY J KAISER MTA has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N32205-17-R-4008

USNS HENRY J. KAISER (T-AO 187)

REQUEST FOR SPECIFICATION CLARIFICATION

NAME OF CONTRACTOR:

SPECIFICATION ITEM NO.:

301 and 302

PARAGRAPH / SECTION NO:

301 (3.2) 302 (3.1.2) and (7.3.1)

TITLE:301 Circuit Breaker Inspection and 302 Main and Emergency Cleaning

QUESTION:

In Item 301 the specification directs the contractor to perform the complete annual inspection, maintenance and repairs on designated air circuit breakers listed in 3.2.

In Item 302, 7.3.1 states that Government shall provide a technical representative to overhaul the main and emergency switchboard breakers as listed in paragraph 3.1.2. Provide the services of two qualified electricians to assist the Technical Representative in overhauling the breakers.

It appears that following circuit breakers are duplicated between item 301 and 302;

1. 1SA Tie Breaker - Main SWBD Tie Breaker 100H-3, Frame: 4000 Amps, Relay: 4000 Amps.

2. 1SB Tie Breaker - Main SWBD Tie Breaker 100H-3, Frame: 4000 Amps, Relay: 4000 Amps.

3. 1E-4P-LC7 – FWD Load Center LC7, 30HL-3, Frame: 600 Amps 600 Amps

4. 1E-4P-F – 120 VAC Emergency Buss, 30HL-3, Frame: 600 Amps, 400 Amp Relay.

5. 1E-4EL(1-40-1) – Emergency PP 1-40-130HL-3, Frame: 600 Amps, Relay: 150 Amps

6. 1SA-4P-GC3/4 – RAS Station 3 and 4 50HL-3, Frame 1600 Amps, Relay: 1200 Amps.

7. SPARE BREAKER (in Electric Shop) 30HL-3, Frame: 600 Amps, 400 Amps

Please advise which item the above breakers will be serviced.

ANSWER:

Item 302 Para 7.3.3 states contractor prove all labor, material and equipment

Second 7.3.1 has been removed for government providing technical representative to overhaul the main and emergency switchboard breakers

ATTACHMENT J - 8

henry.robson@navy.mil