USNS JOSHUA HUMPHREYS
(T-AO 188)
ELECTRICAL
JULY 2016
| SERVICE |
| CATEGORY "A" |
| MSFSC/HR/WP |
GENERATOR MAINTENANCE (CASREP 16-017)
1.0 ABSTRACT:
1.1 Perform bearing checks on the PORT PTO Generator. Replace PTO bearings and seals as necessary.
2.0 REFERENCE/ENCLOSURES:
2.1 References (On board during bidder survey)
2.1.1 NAVSEA Tech Manual T9311-AX-MMC-010, "Generators Sets"
2.2 Enclosure
2.2.1 None
3.0 ITEM LOCATION/DESCRIPTION:
3.1 Location/Quantity
3.1.1 Lower Level, Engine Room (4-60-0)/ One (1) PTO Generator
3.2 Description/Quantity
3.2.1 PTO Generator Sets.
Unit
Qty PTO (Generator) (1)
| Manufacturer |
| ACEO |
| Model |
| PA125G70/8P |
| Type |
| Synchronous |
| Excitation |
| Brushless |
| Rated Power |
| 2500 KW |
450 V, 60 Hertz, 3phase
| KVA |
| 3.125 kVA |
| Speed (max) |
| 1200 rpm |
| Power Factor |
| 0.8 lagging |
| Insulation |
| Class ‘F’ |
3.3 Contractor Furnished Material:
3.3.1 NONE
4.0 GOVERNMENT FURNISHED MATERIAL:
4.1 Material: None
5.0 NOTES:
5.1 USNS JOSHUA HUMPHREYS
POP: July 9-10
LOCATION: PHILLIPINES
POC Wesley Payne 757-443-0892 / 757-449-6924
Wesley.Payne2@navy.mil
6.0 QUAILITY ASSURANCE REQUIREMENTS:
6.1 None Additional
7.0 STATEMENT OF WORK REQUIRED:
7.1 USNS JOSHUA HUMPHREYS
7.1.1 Provide the services of an OEM Renk Bearing representative to perform the following:
7.1.2 Open, clean, and inspect the PTO drive end (DE) and non-drive (NDE) end bearing assemblies, condition and clearances. (2 total bearing assemblies) provide and replace sealant.
7.2 After inspection by the Manufacturer’s Technical Representative and the Chief Engineer. Submit an “As Found” Condition Report to the MSCREP
7.3 Recommended Tech Rep. Sources:
RENK Corp 304 Tucapau Rd Duncan, SC 29334
Phone (864) 433-0069
7.4 All test and inspections to be witnessed by Chief Engineer or MSC Representative.