(1) Can we deliver and install the product during business hours?
a. 7 – 4:30
(2) Is there a loading dock?
a. Yes with a fright elevator
(3) If there isn’t a loading dock, where will we offload the truck?
(4) Approximately, how far is it from the truck offload site to the install location?
a. Loading dock is in the back of the bldg. and the freight elevator is about 75 feet away.
(5) Are there any stairs that the product will need to go up or down to reach the install location?
a. No an elevator can be used
(6) Will we use a passenger or freight elevator for delivery to the install location?
a. freight
(7) Are any electrical or data cabling services required?
a. The furniture should support the whips to power the furniture. Our internal electrician will make the connections the furniture vendor will supply the whips and or power poles needed.
(8) Do we need to provide an electrician to attach the systems furniture to building power? If so, do we need to pull new circuits from the electrical panel or will we attach to existing power at walls/columns?
a. No
(9) In regards to the Single Overhead per station. Should it be an open shelf or a closed bin with a door? Please see sample images below.
a. Closed bin with a door
(10) Please confirm if the attached panels highlighted in yellow are to be 16” high glass at the top of the panel (1/4 glass panel). Also, if there are other panels that are to be ¼ glass, please indicate on the plan.
a. Walls that are against the perimeter do not get glass walls all others do except for the back of cubes 3 and 4. Please reference the attached floor plan.
(11) Do the work surfaces require electrical sit/stand bases? In the attached plan, sit/stand bases are shown under the extended corners but they are not called out in the written requirements.
a. Yes, height adjustable should be included for the corners areas.
(12) Is the Printer Area to be 28”Deep x 36” Wide? The plan shows a much larger printer area.
a. Yes the printer area is 28”Deep x 36” Wide.
(13) Some of the panels identified in Section B include Monolithic Laminate Tile. Do the panels need to have laminate on the face or is tackable fabric acceptable? If laminate is required, please identify the locations you require laminate face panels.
a. Every cube facing an aisle should be laminate all others are fabric.