RTPS V PES Room Console Requirements Document

Rev E

PES Room Console Requirements For

RTPS V

Rev E

12 JUN 2015

Prepared by:

Naval Air Warfare Center Aircraft Division

Atlantic Test Range, NAVAIR National Range Department

Patuxent River, MD

TABLE OF CONTENTS

31.0 Executive Overview

2.0 Document Scope

3.0 Assumptions

4.0 Requirements

4.1 Functional Requirements

4.1.1 All Consoles

4.1.2 Two-Person Consoles

4.1.3 Three-Person Consoles

4.1.4 Four-Person Consoles

4.1.5 Seven-Person Consoles

4.1.6 Eight-Person Consoles

4.2 Physical Requirements

4.2.1 All Consoles

4.2.2 Two-Person Consoles

4.2.3 Three-Person Consoles

4.2.4 Four-Person Consoles

4.2.5 Seven-Person Consoles

4.2.6 Eight-Person Consoles

4.3 Electrical Requirements

5.0 Acronyms

Appendix A – Compunetix Equipment

LIST OF TABLES

4Table 1 – Equipment List for Two, Three and Four-Person Configurations

5Table 2 – Equipment List for Seven and Eight-Person Configurations

13Table 3 – Compunetix Equipment Sizes

CONSOLE REQUIREMENTS

1.0 Executive Overview

The Real-time Telemetry Processing System (RTPS) is used at the Naval Air Warfare Center Aircraft Division at Patuxent River, MD to monitor test flights of DoD aircraft and aircraft systems. RTPS is developed, operated and maintained by the Telemetry Systems Branch (5.2.4.3) which is located at the Atlantic Test Range, Bldg 2118. The primary use of the system is to provide real-time monitoring of test flights to ensure crew safety. Additionally, the use of RTPS for real-time test flight monitoring ensures that test points are achieved increasing test efficiency.

The current system (RTPS IV) has been in service since 2002. There are currently nine data monitoring rooms, called Project Engineer Stations (PES), at Bldg 2118 and one at the Presidential Helicopter Hangar (Bldg 2805).

The Telemetry Systems Branch also has several mobile systems that are based on the RTPS System architecture. One system is installed in a tractor-trailer, one is installed in a mobile van and three are transported in shipping containers and used at remote site locations such as aircraft carriers and other DoD bases around the world.

2.0 Document Scope

The scope of this document includes all of the functional, physical and electrical requirements for the PES Room consoles.

3.0 Assumptions

The term ‘workstation area’ used within this document describes the console space required to house all the equipment needed for one person including PC, LCD monitors, monitor arms, keyboard, mouse, video conversion equipment, audio control panel and headset extender boxes.

The term ‘workstation operator’ used within this document describes the Test Team member sitting at the consoles during real-time Flight Testing.

The term ‘equipment enclosure’ used within this document describes the enclosed area below the console desktop used to house workstation operator equipment.

Several different console configurations are required for this upgrade effort (e.g. two, three, four, seven and eight-person consoles). Tables 1 and 2 describe the equipment that the consoles will be required to house for each workstation operator in the different console configurations. The equipment described in Tables 1 and 2 will be procured under a separate contract.

Table 1 – Equipment List for Two, Three and Four-Person Configurations

Manufacturer
Model
Description
Mounting Area
Quantity
Dell
T3600
PC
Equipment Enclosure
1
Dell
KB212-B
Full-size keyboard
Keyboard Tray
1
Dell
MS111
Optical mouse
Desktop
1
Dell
U2414H
24” LCD monitors
Mounting Arms
2
Innovative Office Products
IOP 7000-500
Monitor mounting arm
Desktop
2
Apantac
DA-HDTV-SDI
HDMI/DVI-to-SDI Converter
Equipment Enclosure Shelf
2
Apantac
DA-SDI-HDTV
SDI-to-HDMI/DVI Converter
Equipment Enclosure Shelf
2
Compunetix
TRI‑D6 II
Display Control Unit
Desktop

Enclosure Note1

Compunetix
SDAP
Secure Digital Audio Processor
Equipment Enclosure
Note 1
Compunetix
LEMO JACKBOX
Headset Extender Box
Under Desktop
Note 1
IHSE USA
Series 483 DRACO vario
DisplayPort

KVM Extender

Equipment Enclosure Shelf
Note 2
APC
Smart-UPS 1500
UPS
Equipment Enclosure
Note 3

Note 1: For the two-person console, one DCU, SDAP and Headset Extender Box are required. For the three and four-person consoles, two DCU, SDAP and Headset Extender Boxes are required. The DCU and SDAP are separate items that can be mounted separately or combined into one physical device. The intent is to mount these units separately. See Appendix A for sizing details.

Note 2: The KVM extender is used for an overflow PC that is installed in an equipment rack in the back of the PES Room. Space for one KVM receive module is required in each of the three and four-person consoles.

Note 3: For the two and three-person consoles, one UPS unit is required. For the four-person consoles, two UPS units are required.

Table 2 – Equipment List for Seven and Eight-Person Configurations

Manufacturer
Model
Description
Mounting Area
Quantity
Dell
T3600
PC
Equipment Enclosure
1
Dell
KB212-B
Full-size keyboard
Keyboard Tray
1
Dell
MS111
Optical mouse
Desktop
1
Dell
U2414H
24” LCD monitors
Mounting Arms
4
Apantac
DA-HDTV-SDI
HDMI/DVI-to-SDI Converter
Equipment Enclosure Shelf
4
Apantac
DA-SDI-HDTV
SDI-to-HDMI/DVI Converter
Equipment Enclosure Shelf
2
Compunetix
TRI‑D6 II
Display Control Unit
Desktop

Enclosure Note 4

Compunetix
SDAP
Secure Digital Audio Processor
Equipment Enclosure
Note 4
Compunetix
LEMO JACKBOX
Headset Extender Box
Under Desktop
Note 4
IHSE USA
Series 483 DRACO vario
DisplayPort

KVM Extender

Equipment Enclosure Shelf
Note 5
APC
Smart-UPS 1500
UPS
Equipment Enclosure
4

Note 4: For the seven and eight-person consoles, four DCU, SDAP and Headset Extender Boxes are required. The DCU and SDAP are separate items that can be mounted separately or combined into one physical device. The intent is to mount these units separately. See Appendix A for sizing details.

Note 5: The KVM extender is used for an overflow PC that is installed in an equipment rack in the back of the PES Room. Space for two KVM receive modules is required in each of the seven and eight-person consoles.

4.0 Requirements

The following requirements are for the RTPS V Project Engineer Station (PES) consoles. These consoles are used by Test Team personnel during real-time Flight Testing. The console design accommodates several different configurations depending on the location within the PES Room. The different configurations required include consoles for two, three, four, seven and eight people. The equipment to be installed in and on the consoles is described in Tables 1 and 2 for all configurations. All console configurations must meet the requirements specified below.

4.1 Functional Requirements

4.1.1 All Consoles

[REQ1] The RTPS V console desktop shall be constructed out of solid wood (i.e. not using particle board).

[REQ2] The RTPS V console desktop shall be covered with a laminate top.

[REQ3] The RTPS V console desktop color shall be Wilsonart Laminate Cloud Nebula (4630-60).

[REQ4] The RTPS V console desktop shall contain a black, ergonomic beveled front edge.

[REQ5] The RTPS V console sides shall contain a black powder coating.

[REQ6] The RTPS V consoles shall contain a pull-out keyboard tray at each workstation area made to hold a standard size keyboard. The workstation mouse will be installed on the console desktop.

[REQ7] The RTPS V console design shall contain a monitor arm mounting mechanism that provides for continuous positioning across the entire width of the console.

[REQ8] The RTPS V console design shall be capable of utilizing IOP 7000-500 LCD monitor arms for the mounting of LCD monitors.

[REQ9] The RTPS V console design shall contain an equipment enclosure with integrated shelving sufficient to contain the equipment in Tables 1 and 2 with a Mounting Area designated as ‘Equipment Enclosure Shelf’.

[REQ10] The RTPS V console design shall contain removable front-side equipment enclosure doors.

[REQ11] The RTPS V console design shall contain removable rear-side equipment enclosure doors.

[REQ12] The RTPS V console design shall contain ventilation holes in the equipment enclosure to allow sufficient forced air up through the bottom of the console for cooling the equipment described in Tables 1 and 2.

[REQ13] The RTPS V console equipment enclosure doors shall be vented to allow cooling air to flow.

[REQ14] The RTPS V console design shall contain a forward-facing enclosure for the installation of the Compunetix DCU on the rear-side of the console desktop. See Appendix A for sizing details.

[REQ15] The RTPS V console design shall accommodate mounting the Compunetix DCU at an angle that provides easy access to the workstation operator.

[REQ16] The mounting enclosures for the Compunetix DCU shall be vented to allow for cooling the installed equipment.

NOTE: The mounting enclosure for the Compunetix DCU can be an enclosure that sits on the desktop as opposed to being integrated into the console.

[REQ17] The RTPS V consoles shall be capable of housing the Compunetix Headset Extender Boxes under the console desktop (front-side) so that they are easily accessible by the workstation operator.

NOTE: The Headset Extender Boxes will be screwed into the underside of the console desktop.

[REQ18] The RTPS V consoles shall contain an equipment enclosure that can house the equipment described in Tables 1 and 2 with sufficient room for maintenance.

[REQ19] The RTPS V consoles shall contain an equipment enclosure that can house one Uninterruptable Power Supply (UPS) for every two workstation areas. See Table 1 and 2.

[REQ20] The RTPS V consoles shall contain sufficient cable management to enable the routing of cables through the entire length of the console.

[REQ21] The RTPS V consoles shall contain sufficient access holes to install cables into the equipment enclosure from underneath. The consoles will be installed on raised floors and the cables will be fed up into the bottom of the equipment enclosures.

[REQ22] The RTPS V console design shall contain sufficient access holes necessary for the desktop equipment identified in Tables 1 and 2.

[REQ23] The RTPS V console design shall contain no structures above the desktop surface. The monitor mounting hardware is not considered a structure.

4.1.2 Two-Person Consoles

[REQ24] The RTPS V two-person console design shall provide space sufficient for mounting two 23” LCD monitors side-by-side in each workstation area. The monitor arms (IOP 7000-500) for the two-person consoles will be obtained through a separate procurement.

[REQ25] For the two-person consoles, the mounting enclosures for the Compunetix DCU shall be centered between the two workstation areas.

[REQ26] The Headset Extender Boxes shall be capable of being mounted at the same position as the DCU mounting enclosure described in REQ25.

[REQ27] The RTPS V two-person console design shall allow for the monitors, installed on the IOP 7000-500 mounting arms, to be lowered to within 2 inches of the desktop while not hitting the top of the DCU mounting enclosure.

4.1.3 Three-Person Consoles

[REQ28] The RTPS V three-person console design shall provide space sufficient for mounting two 23” LCD monitors side-by-side in each workstation area. The monitor arms (IOP 7000-500) for the three-person consoles will be obtained through a separate procurement.

[REQ29] For the three-person consoles, mounting enclosures for the Compunetix DCU shall be centered between the first/second and second/third workstation areas.

[REQ30] The Headset Extender Boxes shall be capable of being mounted at the same positions as the DCU mounting enclosures described in REQ29.

[REQ31] The RTPS V three-person console design shall allow for the monitors, installed on the IOP 7000-500 mounting arms, to be lowered to within 2 inches of the desktop while not hitting the top of the DCU mounting enclosure.

4.1.4 Four-Person Consoles

[REQ32] The RTPS V four-person console design shall provide space sufficient for mounting two 23” LCD monitors side-by-side in each workstation area. The monitor arms (IOP 7000-500) for the four-person consoles will be obtained through a separate procurement.

[REQ33] For the four-person consoles, the mounting enclosures for the Compunetix DCU shall be centered between every two workstation areas.

[REQ34] The Headset Extender Boxes shall be capable of being mounted at the same positions as the DCU mounting enclosures described in REQ33.

[REQ35] The RTPS V four-console design shall allow for the monitors, installed on the IOP 7000-500 mounting arms, to be lowered to within 2 inches of the desktop while not hitting the top of the DCU mounting enclosure.

4.1.5 Seven-Person Consoles

[REQ36] The RTPS V seven-person console design shall provide space sufficient for mounting four 23” LCD monitors in a two-by-two configuration in each workstation area.

[REQ37] The RTPS V seven-person consoles shall contain the monitor mounting hardware required for the two-by-two monitor configuration.

[REQ38] For the seven-person consoles, mounting enclosures for the Compunetix DCU shall be centered between the first/second, third/fourth, fifth/sixth and sixth/seventh workstation areas.

[REQ39] The Headset Extender Boxes shall be capable of being mounted at the same positions as the DCU mounting enclosures described in REQ38.

[REQ40] The RTPS V console design shall contain the ability to easily separate the seven-person consoles into two sections to facilitate repositioning the consoles.

4.1.6 Eight-Person Consoles

[REQ41] The RTPS V eight-person console design shall provide space sufficient for mounting four 23” LCD monitors in a two-by-two configuration in each workstation area.

[REQ42] The RTPS V eight-person consoles shall contain the monitor mounting hardware required for the two-by-two monitor configuration.

[REQ43] For the eight-person consoles, the mounting enclosures for the Compunetix DCU shall be centered between every two workstation areas.

[REQ44] The Headset Extender Boxes shall be capable of being mounted at the same positions as the DCU mounting enclosures described in REQ43.

[REQ45] The RTPS V console design shall contain the ability to easily separate the eight-person consoles into two sections to facilitate repositioning the consoles.

4.2 Physical Requirements

4.2.1 All Consoles

[REQ46] The RTPS V consoles shall contain no less than 44 inches of horizontal (left-to-right) desktop space for each workstation area.

[REQ47] The RTPS V consoles shall contain no less than 28 inches of desktop depth (front-to-back).

[REQ48] The RTPS V console desktop shall be no more than 30 inches from the floor.

[REQ49] The RTPS V console pull-out keyboard tray shall be no less than 26 inches from the floor.

[REQ50] The RTPS V console pull-out keyboard tray shall contain an ergonomic front edge that is no more than 1 inch in height (i.e. from the bottom of the keyboard tray).

[REQ51] The RTPS V console depth (overall front-to-back dimension) shall be no more than 36 inches.

[REQ52] The RTPS V console design shall allow for sufficient operator legroom by containing no less than 16 inches of open space between the front-edge of the desktop to the top of the equipment enclosure (i.e. knee space).

[REQ53] The RTPS V console design shall allow for sufficient operator legroom by containing no less than 20 inches of open space between the front-edge of the desktop to the bottom of the equipment enclosure (i.e. foot space).

[REQ54] The RTPS V console design shall retain the legroom described in REQ52 and REQ53 for the entire length of the console (i.e. contain no obstruction prohibiting the operator from sliding their chair the entire length of the console).

[REQ55] The RTPS V console equipment enclosure doors shall be no more than 24 inches in width.

[REQ56] The RTPS V console design shall contain a mounting enclosure for the Compunetix DCU that is no more than 21 inches in width.

[REQ57] The RTPS V console design shall contain a mounting enclosure for the Compunetix DCU that is no more than 6 inches in height from the console desktop.

[REQ58] The distance between the front edge of the mounting enclosure for the Compunetix DCU and the front edge of the desktop shall be no less than 18 inches.

4.2.2 Two-Person Consoles

[REQ59] The RTPS V two-person console width (overall left-to-right dimension) shall be no more than 92 inches.

4.2.3 Three-Person Consoles

[REQ60] The RTPS V three-person console width (overall left-to-right dimension) shall be no more than 138 inches.

4.2.4 Four-Person Consoles

[REQ61] The RTPS V four-person console width (overall left-to-right dimension) shall be no more than 182 inches.

4.2.5 Seven-Person Consoles

[REQ62] The RTPS V seven-person console width (overall left-to-right dimension) shall be no more than 317 inches.

4.2.6 Eight-Person Consoles

[REQ63] The RTPS V eight-person console width (overall left-to-right dimension) shall be no more than 362 inches.

4.3 Electrical Requirements

[REQ64] The RTPS V consoles shall contain no less than 16, 15-Amp outlets at each workstation area.

[REQ65] The RTPS V console design shall contain at least one, external 15 Amp power outlet that is accessible at each workstation area for overflow equipment (e.g. a laptop placed on the console desktop).

[REQ66] The RTPS V console external 15 Amp power outlets shall be connected to one of the power strips located in the equipment enclosure.

5.0 Acronyms

AC

Alternating Current

DCU

Display Control Unit

DoD

Department of Defense

LCD

Liquid Crystal Display

PES

Project Engineer Station

RTPS

Real-time Telemetry Processing System

RU

Rack Unit

SDAP

Secure Digital Audio Processor

UPS

Uninterruptable Power Supply Appendix A – Compunetix Equipment Table 3 – Compunetix Equipment Sizes

Item
Width (inches)
Height (inches)
Depth (inches)
DCU
19.0
3.5
3.0
SDAP
19.0
1.75
7.5
LEMO JACKBOX
7.0
2.0
2.5

Note: The DCU is a 2 RU rack-mountable box and the SDAP is a 1 RU rack-mountable box.