SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time has changed from 29-Aug-2013 02:00 PM to 05-Sep-2013 02:00 PM.
The following have been added by full text:
QUESTIONS AND ANSWERS
Q1. I am not sure how to quote prices when multiple items are needed to meet the requirements of one CLIN.
For example, CLIN X004 External Input Module: Table 1 External Input Types shows 13 different requirements which have previously been met by several different modules with various prices. Can we list the modules/prices or do we have to establish one price that covers any?
Also:
X008 Recalibration: addressed in question 5 below.
X014 Programming/Charging Kit: addressed in question 9 below.
X015 External Accelerometer Tri-Axial XX YY: addressed in question 10 below.
A1. You list separate models with prices or preferably as families (similar items) of items with one price per family.
Q2. Many items listed as Objective need development. Should we quote the price for Threshold units or include development costs and quote Objective versions?
A2. We are mainly looking for COTS items with no development needed if you meet an Objective or can move to an objective at no additional cost all the better but the Threshold values shall meet our current requirements.
Q3. Item 0001 is a Standard 6DoF with the ability to accept one external input. We recommend using the Enhanced 6DoF when this need arises. What is the reason for adding an input to the existing Standard unit rather than using the Enhanced version?
A3. We often only need one external input and we were trying to see if there was a lower cost solution. The ability to take an external input is also listed as an objective not a threshold. We are looking at the lowest cost solutions.
Q4. Item 0003 Miniature 6DoF: Is this for a particular weapon or test? Is there any flexibility in the size or requirements? Are the standard DSU-33 and MXU-735 adapters to fit on it?
A4. This is not for a specific program but based on multiple inquiries. Because we are trying to fill multiple gaps there is flexibility in size and capability but the smaller and more capable the more useful the unit will be. This would not use any fuze well adapters but should have some means of attaching on multiple sides.
Q5. Item 0004 External Input Module: Table 1 is a sample of known modules, but we are not familiar with lines 5-8 and 11 and 13. Are you looking for development of these items? Can you give an example of a digital input application? Would a GPS signal be supplied or does the proposed module include a receiver and antenna?
A5
5-8 should be very similar to item 3 just with different input ranges
Digital input could be a RS-232, RS-422, RS 485 signals
The GPS unit should have a receiver but quoting an antenna is not necessary or it could be an option as long as you call out what is quoted.
Q6. Item 0008: Recalibration prices vary by model. Can prices be given for each model or must a price be established that covers any model?
A6. It can be quoted either way. One price makes paperwork easier but we would rather have lower cost.
Q7. Item 0009: Existing designs cannot accommodate the addition of Memory. Should we quote development of new 6DoF units with room for memory?
A7. The intent of this was a low cost memory add on that will not affect the overall price of a 6DoF. Internal can be within the 6DoF or within the store if the memory cannot fit inside of the 6DoF it should be of minimal size (i.e. memory card and wire pig tail) environmentally sealed with some form of mounting.
Q8. Item 0010: Repackaging - How does this work? Do we agree to develop new designs for amounts not to exceed the values in the NTE Table?
A8. Refer to Section L and bid in accordance with the Not to Exceed (NTE) table.
Q9. Item 0013: Is a 5 W transmitter required? Current designs have up to 2 W.
A9. The 5W can be considered the objective. We would like to be at 5W but lower values are acceptable.
Q10. Item 0014: Is a kit containing all these accessories required? Or would it be better to separate the different items?
A10. They can be priced separately
Q11. Item 0015: Accelerometers vary in price by model. Can prices be given for two model categories (i.e. standard and low noise (<1 mg/√Hz)) or must a price be established that covers any model?
A11. Multiple prices can be provided
Q12. Will shipping costs have line items on the contract or is there another method to cover these costs?
A12. The preference is to have shipping built into the price of the item to make ordering easier so we do not have to track different shipping rates or to have shipping discounts for multiple items delivered at the same time.
The following have been modified:
ADMIN
SECTION A
Block 9
PoC Daniel Nevins
301-757-9714 daniel.nevins@navy.mil
INSTRUCTIONS
SECTION A – SOLICITATION/CONTRACT FORM
EXECUTIVE SUMMARY
The U.S. Naval Air Warfare Center Aircraft Division (NAWCAD) proposes to award a Firm Fixed Priced Contract for Inertial Measuring Telemetry Equipment. The Statement of Work is included in Section C of this document. This solicitation is being issued as a full and open competition for business firms that are capable of providing the supplies and services described herein.
1. The awarded contract will consist of a Firm Fixed Price Indefinite Delivery/Indefinite Quantity Contract with one base year and four (4) option years. Only one contract will be awarded; multiple contracts will not be awarded. FAR Part 12, Acquisition of Commercial Items, and Part 15, Contracting by Negotiation, will apply.
2. Offerors are to submit a single proposal that includes all requirements set forth in this document. Evaluation of offerors’ proposals for award of contract will be Lowest Price Technically Acceptable (LPTA). Section L of the solicitation specifies what is required from offerors in their proposals. Section M specifies how the Government will evaluate offerors’ proposals.
3. NOTICE: Section L of this document contains FAR Clause 52.212-1, INSTRUCTIONS TO OFFERORS -- COMMERCIAL ITEMS. Please pay particular attention to paragraph (k), which states that lack of registration in the CCR will render an offeror ineligible for award. If already registered, offerors are strongly encouraged to review and update their registry at the time of proposal submission.
4. Offerors are required to complete the Online Representations and Certification Application (ORCA) at the time of proposal submission. If already submitted, offerors are strongly encouraged to review and update their
ORCA record at the time of proposal submission. Please see: https://orca.bpn.gov/
5. Clauses and provisions in this document may not appear in consecutive order. Clauses and provisions from the
Federal Acquisition Regulation (FAR) and supplements thereto are incorporated in this document by reference and in full text. Those incorporated by reference have the same force and effect as if given in full text.
6. FORMAL COMMUNICATION: Any formal communication, such as requests for clarifications, discussions, and information concerning this solicitation should be submitted in writing electronically to the address below:
Daniel Nevins:
Daniel.Nevins @navy.mil NOTE: Oral explanations or instructions given before the award of a contract will not be binding.
7. AMENDMENTS PRIOR TO DATE SET FOR RECEIPT OF PROPOSALS: The Government may revise or amend any aspect of the Solicitation prior to the date set for receipt of proposals. If the revisions and amendments are of a nature which requires material changes in quantities, prices offered, or both, the date set for receipt of proposals may be postponed such number of days as in the opinion of the issuing officer will enable bidders to revise their proposals. In such cases, the amendment will include an announcement of the new date for receipt of proposals. Please acknowledge any amendments to this solicitation by an original signature on the amendment itself and submitting each with your proposal. Acknowledgement of all amendments received is important because failure to do so will render your offer nonresponsive.
8. INCONSISTENCIES: This Executive Summary has been prepared as an aid to you, the potential offeror. We have made every attempt to accurately reflect the requirements and information contained in this solicitation. However, if you find any inconsistency between this executive summary and the solicitation, the solicitation takes precedence.
PRICING INSTRUCTIONS
1.0 General Information
The contractor is required to complete Cost Summary Format in accordance with the instructions. The table will be used to determine the overall evaluated contract price. The pricing table will also be used for administration after contract award. The Government will not pay prices other than those listed on the price table.
All solicited items must be in the pricing table(s). If there is no charge associated with the item, “N/C” (no charge) shall be inserted in the unit price column. The contractor must modify the pricing tables to include any additional pricing for items in the Statement of Work, which are not already listed in the pricing tables.
2.0 Instructions for Completing Unit Pricing Table The contractor is required to complete the pricing tables that are listed in attachment A.1 – Pricing Tables. The attachment will be used to determine the overall evaluated contract price.
3.0 GOVERNMENT-FURNISHED INFORMATION
The Government's Not-To-Exceed (NTE) values for repackaging are listed below:
| CLIN |
| TOTAL COST |
| 0010 |
| $25,000.00 |
| 1010 |
| $27,500.00 |
| 2010 |
| $30,000.00 |
| 3010 |
| $32,500.00 |
| 4010 |
| $35,000.00 |
Offerors shall utilize the NTE amounts provided above for Repackaging CLINs 0010, 1010, 2010, 3010, and 4010.
The Government's Not-To-Exceed (NTE) values for Over and Above Direct Parts and Materials are listed below:
| CLIN |
| TOTAL COST |
| 0017 |
| $5,000.00 |
| 1017 |
| $5,000.00 |
| 2017 |
| $5,000.00 |
| 3017 |
| $5,000.00 |
| 4017 |
| $5,000.00 |
Offerors shall utilize the NTE amounts provided above for Repackaging CLINs 0017, 1017, 2017, 3017, and 4017. Over and Above Direct Parts and Materials will be negotiated at a cost basis at the delivery order level.
SECTION B - SUPPLIES OR SERVICES AND PRICES
CLIN 0004
The CLIN type priced has been deleted.
The pricing detail quantity 75.00 has been deleted.
CLIN 0008
The CLIN type priced has been deleted.
The pricing detail quantity 100.00 has been deleted.
CLIN 0014
The CLIN type priced has been deleted.
The CLIN description has changed from Programming/Charging Kit to Operating Components for 6DoF.
The pricing detail quantity 10.00 has been deleted.
CLIN 0015
The CLIN type priced has been deleted.
The pricing detail quantity 10.00 has been deleted.
CLIN 1004
The CLIN type priced has been deleted.
The pricing detail quantity 75.00 has been deleted.
CLIN 1008
The CLIN type priced has been deleted.
The pricing detail quantity 100.00 has been deleted.
CLIN 1014
The CLIN type priced has been deleted.
The CLIN description has changed from Programming/Charging Kit to Operating Components for 6DoF.
The pricing detail quantity 10.00 has been deleted.
CLIN 1015
The CLIN type priced has been deleted.
The pricing detail quantity 10.00 has been deleted.
CLIN 2004
The CLIN type priced has been deleted.
The pricing detail quantity 75.00 has been deleted.
CLIN 2008
The CLIN type priced has been deleted.
The pricing detail quantity 100.00 has been deleted.
CLIN 2014
The CLIN type priced has been deleted.
The CLIN description has changed from Programming/Charging Kit to Operating Componets for 6DoF.
The pricing detail quantity 10.00 has been deleted.
CLIN 2015
The CLIN type priced has been deleted.
The pricing detail quantity 10.00 has been deleted.
CLIN 3004
The CLIN type priced has been deleted.
The pricing detail quantity 75.00 has been deleted.
CLIN 3008
The CLIN type priced has been deleted.
The pricing detail quantity 100.00 has been deleted.
CLIN 3014
The CLIN type priced has been deleted.
The CLIN description has changed from Programming/Charging Kit to Operating Components for 6DoF.
The pricing detail quantity 10.00 has been deleted.
CLIN 3015
The CLIN type priced has been deleted.
The pricing detail quantity 10.00 has been deleted.
CLIN 4004
The CLIN type priced has been deleted.
The pricing detail quantity 75.00 has been deleted.
CLIN 4008
The CLIN type priced has been deleted.
The pricing detail quantity 100.00 has been deleted.
CLIN 4014
The CLIN type priced has been deleted.
The CLIN description has changed from Programming/Charging Kit to Operating Components for 6DoF.
The pricing detail quantity 10.00 has been deleted.
CLIN 4015
The CLIN type priced has been deleted.
The pricing detail quantity 10.00 has been deleted.
SUBCLIN 0004AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AA
Strain Gauge 5V Excitation
FFP
FOB: Destination
NET AMT
SUBCLIN 0004AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AB
Accelerometer
NET AMT
SUBCLIN 0004AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AC
5V to 9V Excitation
NET AMT
SUBCLIN 0004AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AD
0 to 5V Input 5V Excitation
100,000 samples/sec
NET AMT
SUBCLIN 0004AE is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AE
-500 to 500V DC/AC Input
NET AMT
SUBCLIN 0004AF is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AF
Digital Input
(RS422, RS232, RS485, and/or Optical)
NET AMT
SUBCLIN 0004AG is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AG
Dual FMU-139
Simulator for use with -500 to 500V
NET AMT
SUBCLIN 0004AH is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0004AH
GPS
NET AMT
SUBCLIN 0008AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0008AA
Standard 6DoF
Recalibration Tools
NET AMT
SUBCLIN 0008AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0008AB
Enhanced 6DoF
NET AMT
SUBCLIN 0008AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0008AC
Miniature 6DoF
NET AMT
SUBCLIN 0008AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0008AD
External Accelerometer Tri-Axial XX YY
NET AMT
SUBCLIN 0014AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0014AA
Charging Kit
NET AMT
SUBCLIN 0014AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0014AB
Programming/Configuration Kit
NET AMT
SUBCLIN 0014AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0014AC
Activating Kit
NET AMT
SUBCLIN 0015AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0015AA
Standard External Accelerometer
Tri-Axial XX YY
For use with External Instrumentation Module XX is Gs +/- and YY is analog filter value
NET AMT
SUBCLIN 0015AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
0015AB
Low Noise External Accelerometer
Tri-Axial XX YY
NET AMT
CLIN 0017 is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Parts & Materials
COST
Over and Above Direct Parts and Materials
ESTIMATED COST
SUBCLIN 1004AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AA
Strain Gauge 5V Excitation
NET AMT
SUBCLIN 1004AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AB
Accelerometer
NET AMT
SUBCLIN 1004AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AC
5V to 9V Excitation
NET AMT
SUBCLIN 1004AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AD
0 to 5V Input 5V Excitation
NET AMT
SUBCLIN 1004AE is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AE
-500 to 500V DC/AC Input
NET AMT
SUBCLIN 1004AF is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AF
Digital Input
NET AMT
SUBCLIN 1004AG is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AG
Dual FMU-139
NET AMT
SUBCLIN 1004AH is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1004AH
GPS
NET AMT
SUBCLIN 1008AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1008AA
Standard 6DoF
NET AMT
SUBCLIN 1008AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1008AB
Enhanced 6DoF
NET AMT
SUBCLIN 1008AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1008AC
Miniature 6DoF
NET AMT
SUBCLIN 1008AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1008AD
External Accelerometer Tri-Axial XX YY
NET AMT
SUBCLIN 1014AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1014AA
Charging Kit
NET AMT
SUBCLIN 1014AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1014AB
Programming/Configuration Kit
NET AMT
SUBCLIN 1014AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1014AC
Activating Kit
NET AMT
SUBCLIN 1015AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1015AA
Standard External Accelerometer
Tri-Axial XX YY
NET AMT
SUBCLIN 1015AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
1015AB
Low Noise External Accelerometer
Tri-Axial XX YY
NET AMT
CLIN 1017 is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Parts & Materials
ESTIMATED COST
SUBCLIN 2004AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AA
Strain Gauge 5V Excitation
NET AMT
SUBCLIN 2004AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AB
Accelerometer
NET AMT
SUBCLIN 2004AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AC
5V to 9V Excitation
NET AMT
SUBCLIN 2004AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AD
0 to 5V Input 5V Excitation
NET AMT
SUBCLIN 2004AE is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AE
-500 to 500V DC/AC Input
NET AMT
SUBCLIN 2004AF is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AF
Digital input
NET AMT
SUBCLIN 2004AG is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AG
Dual FMU-139
NET AMT
SUBCLIN 2004AH is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2004AH
GPS
NET AMT
SUBCLIN 2008AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2008AA
Standard 6DoF
NET AMT
SUBCLIN 2008AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2008AB
Enhanced 6DoF
NET AMT
SUBCLIN 2008AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2008AC
Miniature 6DoF
NET AMT
SUBCLIN 2008AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2008AD
External Accelerometer
NET AMT
SUBCLIN 2014AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2014AA
Charging Kit
NET AMT
SUBCLIN 2014AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2014AB
Programming/Configuration Kit
NET AMT
SUBCLIN 2014AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2014AC
Activating Kit
NET AMT
SUBCLIN 2015AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2015AA
Standard External Accelerometer
Tri-Axial XX YY
NET AMT
SUBCLIN 2015AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
2015AB
Low Noise External Accelerometer
Tri-Axial XX YY
NET AMT
CLIN 2017 is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Parts & Materials
ESTIMATED COST
SUBCLIN 3004AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AA
Strain Gauge 5V Excitation
NET AMT
SUBCLIN 3004AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AB
Accelerometer
NET AMT
SUBCLIN 3004AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AC
5 to 9V Excitation
NET AMT
SUBCLIN 3004AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AD
0 to 5V Input Excitation
NET AMT
SUBCLIN 3004AE is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AE
-500 to 500V DC/AC Input
NET AMT
SUBCLIN 3004AF is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AF
Digital Input
(RS422, RS232, RS485, and /or Optical)
NET AMT
SUBCLIN 3004AG is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AG
Dual FMU-139
NET AMT
SUBCLIN 3004AH is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3004AH
GPS
NET AMT
SUBCLIN 3008AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3008AA
Standard 6DoF
NET AMT
SUBCLIN 3008AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3008AB
Enhanced 6DoF
NET AMT
SUBCLIN 3008AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3008AC
Miniature 6DoF
NET AMT
SUBCLIN 3008AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3008AD
External Accelerometer
NET AMT
SUBCLIN 3014AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3014AA
Charging Kit
NET AMT
SUBCLIN 3014AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3014AB
Programing/Configuration Kit
NET AMT
SUBCLIN 3014AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3014AC
Activating Kit
NET AMT
SUBCLIN 3015AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3015AA
Standard External Accelerometer
Tri-Axial XX YY
NET AMT
SUBCLIN 3015AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
3015AB
Low Noise External Accelerometer
Tri-Axial XX YY
NET AMT
CLIN 3017 is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Parts & Materials
ESTIMATED COST
SUBCLIN 4004AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AA
Strain Gauge 5V Excitation
NET AMT
SUBCLIN 4004AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AB
Accelerometer
NET AMT
SUBCLIN 4004AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AC
5 to 9V Excitation
NET AMT
SUBCLIN 4004AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AD
0 to 5V Input 5V Excitation
NET AMT
SUBCLIN 4004AE is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AE
-500 to 500V DC/AC Input
NET AMT
SUBCLIN 4004AF is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AF
Digital Input
NET AMT
SUBCLIN 4004AG is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AG
Dual FMU-139
NET AMT
SUBCLIN 4004AH is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4004AH
GPS
NET AMT
SUBCLIN 4008AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4008AA
Standard 6DoF
NET AMT
SUBCLIN 4008AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4008AB
Enhanced 6DoF
NET AMT
SUBCLIN 4008AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4008AC
Miniature 6DoF
NET AMT
SUBCLIN 4008AD is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4008AD
External Accelerometer Tri-Axial XX YY
NET AMT
SUBCLIN 4014AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4014AA
Charging Kit
NET AMT
SUBCLIN 4014AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4014AB
Programming/Configuration Kit
NET AMT
SUBCLIN 4014AC is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4014AC
Activating Kit
NET AMT
SUBCLIN 4015AA is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4015AA
Standard External Accelerometer
Tri-Axial XX YY
NET AMT
SUBCLIN 4015AB is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
4015AB
Low Noise External Accelerometer
Tri-Axial XX YY
NET AMT
CLIN 4017 is added as follows:
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
Parts & Materials
ESTIMATED COST
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
SECTION C INFORMATION
Items 0001 - 0015, and Option Items 1001 - 1015, 2001 - 2015, 3001 - 3015, and 4001 - 4015 – The contractor shall provide supplies and services in accordance with the Section C Statement of Work to support AIR 5.1.6.
Item 0016 and Option Items 1016 - 4016 – The data to be furnished hereunder shall be in accordance with the Exhibit A, DD Form 1423, Contract Data Requirements List, and the Section C Statement of Work.
STATEMENT OF WORK
Item 0001- Standard 6DoF (CLIN 0008AA)
Self powered unit with a tri-axial accelerometer and a tri-axial rate gyro configuration, internal processing, transmitter, and is sized to fit within a MK80 series fuze well (Threshold). With the ability to accept one input, Table 1 (Objective), (See Table 2 for threshold and objective requirements for components). Units shall be calibrated based on standards listed under Recalibration. The 6Dof shall survive and function properly throughout the entire flight envelope of all Navy, Marine Corps, Air Force, and Army aircraft/weapon systems. The 6DoF shall have the ability to align the sensors to either aircraft coordinate or earth coordinate systems. The 6DoF should have all supporting software and documentation for operation. Software shall allow for but is not limited to setting bit rate, TM frequencies, sensor range values, filter settings for each sensor, and allow for pre-flight checkout for proper function.
Item 0002– Enhanced 6DoF (CLIN 0008AB)
Contains everything in the Standard 6DoF plus the ability to utilize up to sixteen (threshold) and thirty two (objective) internal/external sensors, Table 1 via external input modules. (See Table 2 for threshold and objective requirements for components). Units shall be calibrated based on standards listed under Recalibration.
Item 0003– Miniature 6DoF (CLIN 0008AC)
Contains everything in the Standard 6DoF but is sized to fit inside of a cylinder of 0.9 in radius – 9 in height (threshold) and 0.75 in radius – 5 in height (objective). Lower wattage for transmitter is acceptable with a flight worthy airborne receiver/recorder/rerad combination, provided normal aircraft transmitters do not interfere with lower wattage signal. (See Table 2 for threshold and objective requirements for components). Units shall be calibrated based on standards listed under Recalibration.
Item 0004– P/N XX External Input Module
This item is designed to be an easy to change plug in module for multiple different input options. Table 1 contains a sample list of known types of external input modules, but this is not a complete list as configurations continually change. The intent of this list is to have the ability to purchase any of these type of external input modules for the same price with type being a subgroup to allow flexibility in purchasing.
Item 0005– Monopole Antenna
Either stick or blade antenna is acceptable. Antenna should be optimized for center around 2250 MHz and allow for <10% signal loss at 2200 or 2299 MHz. Antennas should use standard SMA connectors. Antenna shall have a positive means for securing (Safety wire hole or locking nuts based on antenna design).
Item 0006– P/N XX Extension control cable
Allow for communication with/recharging of 6DoF units when installed in a store and/or direct connection to the 6DoF is not available. This cable should allow for the same functions as if directly connected to the 6DoF. The connector on the extension cable cannot exceed the size of a DB9 standard connector (See Table 2).
Item 0007 – P/N XX Extension RF Cable
Allow for remote installation of antenna when 6doF is installed inside of a store. Shall have SMA connectors on either side M/F (See Table 2).
Item 0008– Recalibration
Once the unit has been received by the contractor, the contractor will calibrate the sensors in the 6DoF to the original specification. The contractor shall calibrate each unit using standards of OPNAV INST 3960.16A NAVY TEST, MEASUREMENT, AND DIAGNOSTIC EQUIPMENT (TMDE), AUTOMATIC TEST SYSTEMS (ATS), AND METROLOGY AND CALIBRATION (METCAL). If new methods or procedures of calibration are desired, they must first be approved by the Contracting Officer’s Representative (COR). The contractor shall provide a Calibration Record for each unit that is re-calibrated (CDRL A001). The Calibration Record shall be provided in electronic form within one week from the time the unit was calibrated. After the units are calibrated, the contractor shall affix a new calibration indicator on the unit. The Contractor shall return the calibrated unit(s) back to the government facility within two weeks of receipt.
Item 0009– Memory Upgrade non volatile
This is an upgrade option to the 6DoF units to allow for internal storage of measured data per requirements of Table 2. This memory must retain all recorded data in the event of a power loss and shall not write over existing data on restart. The memory must survive the flight envelope of the 6DoF (threshold) with the objective to be crash/impact survivable (>1000g).
Item 0010– Repackaging for special installations
This line item is to cover the NRE and production costs for specific mounting applications. Repackaging will be negotiated at a cost basis at the delivery order level.
Item 0011– Airborne Data Recorder/Receiver
The airborne data recorder/receiver must be able to receive and record all transmissions from all versions of the 6DoFs. The airborne data recorder shall fit inside of a MK 80 fuze well and utilize the same mounting hardware as the standard 6DoFs. The memory inside of the airborne data recorder shall comply with the memory standards, Table 2. Software to control the airborne data recorder/receiver shall be part of the standard 6DoF software or shall meet the same standards. Threshold is to receive and record one 6DoF TM stream; Objective is to receive multiple by auto switching to a second stream based on an event in the data.
Item 0012– Ground Data Recorder/Receiver
The ground data recorder/receiver must be able to receive and record all transmissions from all versions of the 6DoFs. The ground data recorder shall have a size that is comparable to a standard 15 in. laptop and shall be self powered and ruggedized for flight line use. The memory inside of the airborne data recorder shall comply with the memory standards, Table 2. Software to control the ground data recorder/receiver shall be part of the standard 6DoF software or shall meet the same standards. Threshold is to receive and record one 6DoF TM stream with real time monitoring of data through the recorder/receiver or through a connected laptop; Objective is to have an automated checkout ability to verify proper 6DoF configuration and function prior to a test event.
Item 0013– Retransmit Upgrade to Airborne Data Record (2W upto 5W)
The airborne data retransmitter must be able to interface with the Airborne Data Recorder/Receiver and retransmit all data from all versions of the 6DoFs on a different frequency then it was received on. The airborne data retransmitter shall fit inside of a MK 80 fuze well and utilize the same mounting hardware as the standard 6DoFs. Software to control the airborne data retransmitter shall be part of the standard 6DoF software or shall meet the same standards. Threshold is to retransmit one 6DoF TM stream; Objective is to have iNet like capability.
Item 0014– Operating Components for 6DoF
This kit is comprised of all hardware necessary for the operation of the 6DoF that is not expended during a mission. This includes charging the 6DoFs, Programming/Configuring the 6DoF, and Activating the 6DoF prior to a mission.
Item 0015– External Accelerometer Tri-Axial XX YY (CLIN 0008AD)
This item covers external tri-axial accelerometers that shall be compatible with one of the external input modules where XX is Gs +/- and YY is analog filter. The intent of this list is to have the ability to purchase any of the external accelerometers for the same price with the G and filter being subgroups. Accelerometers shall work with one external input module, Table 1, and meet the requirements of Table 2.
Item 0016 Over and Above Direct Parts and Materials
The Contractor shall provide over and above direct parts and materials in accordance with Section 5.6, “Over and Above Maintenance,” under Attachment 1, SOW, and NAVAIR 5252.217-9507, “Over and Above Work Request” Clause.
Table 1 External Input Types
| CLINS |
| Sensor Type |
| Number of Inputs |
| Threshold |
| Objective |
| 0004AA |
| Strain Gauge 5 V excitation |
| 2 |
| 4 |
| 0004AB |
| Accelerometer |
| 3 |
| 3 + Temp |
| 0004AC |
| 0 to 5 V input 9V excitation |
| 3 |
| 4 or 3 + Temp |
| 0 to 5 V input 5V excitation |
| 3 |
| 4 or 3 + Temp |
| -2.5 to 2.5 V input 9V excitation |
| 3 |
| 4 or 3 + Temp |
| -5 to 5 V input 9V excitation |
| 3 |
| 4 or 3 + Temp |
| 0 to 10 V input 9V excitation |
| 3 |
| 4 or 3 + Temp |
| -10 to 10 V input 9V excitation |
| 3 |
| 4 or 3 + Temp |
| 0004AD |
| 0 to 5 V input 5V excitation (100,000 samples/sec) |
| 1 |
| 4 |
| 0004AE |
| -500 to 500 V DC/AC input |
| 1 |
| 4 |
| 0004AF |
| Digital input (RS422, RS232, RS485, and/or Optical) |
| 1 |
| 4 |
| 0004AG |
| Dual FMU-139 Simulator for use with -500 to 500 V |
| 1 |
| 1 |
| 0004AH |
| GPS |
| Commercial |
| DOD/NSA |
Table 2
| Parameter |
| Threshold |
| Objective |
Sensor Operating Range
Acceleration and Rate ±50g (+/- 15g for miniature)
±1200 deg.sec.
±100g
±2000 deg.sec.
Data Accuracy
Position and Attitude
± 1 in. (first 2 sec.) ± 1 ft. (1 min.)
± 1 deg. (first 2 sec.) ± 10 deg. (1 min.)
| Accelerometer |
| Noise Density: 2 mg/√Hz |
Sensitivity Drift: ±2%
Zero Bias Drift: ±0.5g
Alignment: ±1° Noise Density: 0.05 mg/√Hz
Sensitivity Drift: ±2%
Zero Bias Drift: ±0.1g
Alignment: ±0.5°
| Gyros |
| Noise Density: 0.1°/sec/√Hz |
Sensitivity Drift: ±5%
Zero Bias Drift: ±3°/sec.
Noise Density: 0.05°/sec/√Hz
Sensitivity Drift: ±2.5%
Zero Bias Drift: ±2°/sec.
| Resolution |
| 16 bit |
| Sample Rate |
| 3000 Hz |
| 5000 Hz (Store Separation) |
6000 Hz (Missiles)
20,000 Hz (Captive Carriage)
Filter
5 pole Butterworth analog prior to digitizer (user selectable) all channels
| Battery Operating Time |
| 2 hrs. |
| 4 hrs. |
| TM Range (Re-rad scenario) |
| 10m (to aircraft release to ground impact) |
| 30m |
| TM Frequencies |
| S-Band 2200-2299 user selectable |
| S-Band and C-Band |
| TM Wattage |
| 0.5W |
5 W ReRad
0.5 to 2 W selectable
5 to 10 W selectable for ReRad
| TM Encoding |
| NRZ-L; RNRZ-L |
| Bi Phase; RS485 |
| Usable Frequencies at one time (flight) without TM overlap |
| 12 |
| 100 (can use real time frequency allocation or delayed turn on to prevent frequency overlap) |
| TM Delay/Repeat |
| Individual channels 4 sec delay time |
| Individual channels or entire data stream 4 sec delay time – does not require memory upgrade |
| Memory Storage (when utilized) |
| 2 hrs |
| = to battery life |
Data Recovery over secondary TM (RF/Network/WiFi/Bluetooth/USB)
| Memory Download |
| Download and Reset for next use <= battery recharge time |
| <5 min |
| DSU-33 Adapter |
| Needs to match DSU-33 scalloped shaped, Ref drawing 1, Raydome may be GFE or bid on |
| Can be utilized in aft fuze well without modification to bomb body |
| MXU-735 Adapter |
| Needs to match MXU-735 shape, Ref drawing 2 |
| Aft Fuze Well Adapter |
| Can be DSU-33 Adapter Based or unique design |
| Health Parameters |
| Serial Number, Battery Voltage, Frame counter |
| IRIG Time, Battery Current, CRC (Cyclic Redundancy Check) |
| Encryption |
| 128 Bit WEP |
| Accepts NSA Encryption Card |
SECTION E - INSPECTION AND ACCEPTANCE
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AE:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AF:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AG:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0004AH:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0008AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0008AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0008AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0008AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0014AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0014AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0014AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0015AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 0015AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for CLIN 0017:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AE:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AF:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AG:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1004AH:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1008AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1008AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1008AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1008AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1014AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1014AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1014AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1015AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 1015AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for CLIN 1017:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AE:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AF:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AG:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2004AH:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2008AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2008AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2008AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2008AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2014AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2014AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2014AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2015AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 2015AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for CLIN 2017:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AE:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AF:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AG:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3004AH:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3008AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3008AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3008AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3008AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3014AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3014AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3014AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3015AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 3015AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for CLIN 3017:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AE:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AF:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AG:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4004AH:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4008AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4008AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4008AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4008AD:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4014AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4014AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4014AC:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4015AA:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for SUBCLIN 4015AB:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
The following Acceptance/Inspection Schedule was added for CLIN 4017:
| INSPECT AT |
| INSPECT BY |
| ACCEPT AT |
| ACCEPT BY |
| Destination |
| Government |
| Destination |
| Government |
SECTION F - DELIVERIES OR PERFORMANCE
The following Delivery Schedule item for CLIN 1004 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
31-OCT-2015
| N/A |
| MANNED/UNMANNED AIR VEHICLE EVALUATION |
MARK JORDAN
21960 NICKLES ROAD HGR 201 STE 1A UNIT 4
PATUXENT RIVER MD 20670-1539
301-342-4373
N00421
To:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
| N/A |
| MANNED/UNMANNED AIR VEHICLE EVALUATION |
MARK JORDAN
21960 NICKLES ROAD HGR 201 STE 1A UNIT 4
PATUXENT RIVER MD 20670-1539
301-342-4373
N00421
The following Delivery Schedule item for CLIN 1008 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
| N/A |
| MANNED/UNMANNED AIR VEHICLE EVALUATION |
MARK JORDAN
21960 NICKLES ROAD HGR 201 STE 1A UNIT 4
PATUXENT RIVER MD 20670-1539
301-342-4373
N00421
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
| N/A |
| MANNED/UNMANNED AIR VEHICLE EVALUATION |
MARK JORDAN
21960 NICKLES ROAD HGR 201 STE 1A UNIT 4
PATUXENT RIVER MD 20670-1539
301-342-4373
N00421
The following Delivery Schedule item for CLIN 1014 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
| N/A |
| MANNED/UNMANNED AIR VEHICLE EVALUATION |
MARK JORDAN
21960 NICKLES ROAD HGR 201 STE 1A UNIT 4
PATUXENT RIVER MD 20670-1539
301-342-4373
N00421
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| UIC |
POP 01-NOV-2014 TO
| N/A |
This is the start of the file's text. The full file is on GovTribe.