18Q0342_AMENDMENT_1.docx
DOCX document 38 KB Posted
- Attached to
- SECURITY CAMERAS Federal contract opportunity
- Solicitation number
- N0040618Q0342
About this file
18Q0342_AMENDMENT_1.docx
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Repair_Attachment.xlsx | XLSX spreadsheet | |
| 18Q0342_AMENDMENT_2.docx | DOCX document | |
| WORKSTATION_SPECS.pdf | ||
| ESS_repair_attachment_1.pdf | ||
| N0040618Q0342_CAMERAS.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N0040618Q0342
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
Q&A
1. Do all buildings have conduits?
7115 needs conduit to camera position on the roof from demarc point or there’s a fiber patch panel in the building and fiber would have to be run through the camera.
From 7111 to 7115 there’s conduit but no cable.
For building 7115, the distance from the demarcation to the camera sites is 200ft.
On 7111, camera is being moved, approx. 75ft and contractor would need to splice at the old position and run cable to the new position. Contractor will install conduit here and also in 7115.
Camera 12 is currently in conduit and ran to the roof but will need to be run to the mounted position, approx. 25ft.
2. Are all cameras accessible from the roof?
Bldg 7114, all 4 cameras are mounted 20ft high on 30ft wall, will require lift.
3. Do the new 55 inch monitoring locations need to be interactive?
Yes, they need to be programed to be user-interactive at those locations.
4. Are UPS required for those 55 inch monitoring locations?
Yes, one existing location has UPS. The new locations will also need them; expected support for short duration when power goes out to transfer to back up generator.
5. Voltage for the CDC server is 120v 10amps, or you must have a 208v bus (if your servers use more than 10amps)
6. Is there any switch on the roof? No
The following have been modified:
INFO PAGE
**SOLICITATION MUST BE COMPLETED AND RETURNED IN FULL TO BE CONSIDERED RESPONSIVE** **This request for quote is issued for an anticipated award of a commercial, firm fixed price supply contract** **SITE VISIT is part of the requirement**
1. Site visit requests must be submitted to LT Julian Le at julian.le@navy.mil at least FIVE DAYS PRIOR to the visit date.
2. All questions regarding this solicitation should be submitted in writing to the Contract Specialist, Julian Le at julian.le@navy.mil
3. Offerors shall submit their signed offers electronically to:
julian.le@navy.mil
QUOTE DUE BY 8/27/2018 BY 10:00 AM PST
****CONTACT CONTRACTING OFFICIAL AT: Julian.le@navy.mil or (360) 476-1985
PLEASE PROVIDE:
YOUR NAME:
YOUR CAGE CODE NUMBER: ____________________________________________
YOUR E-MAIL ADDRESS: ________________________________________
YOUR PHONE NUMBER: _________________________________________
YOUR FAX NUMBER: __________________________________________
LIST YOUR COMPANIES SIZE: LARGE OR SMALL________________
(YOUR COMPANY MUST BE REGISTERED WITH **SAM** (SYSTEM AWARD FOR MANAGEMENT** IN ORDER TO RECEIVE A GOVERNMENT AWARD) INTERNET ADDRESS FOR SAM IS: https://www.sam.gov
THIS IS ALWAYS A FREE SITE TO REGISTER TO
RETURN QUOTE TO THE EMAIL ADDRESS ABOVE:
PAYMENT INFORMATION WILL BE ENTERED IN ANY RESULTING AWARD BY GOVERNMENT PURCHASE CARD.
"Base Access Beginning in April 2017, the Navy will transition all bases and installations in the United States, including Hawaii and Guam, from the Navy Commercial Access Control System (NCACS) to DBIDS for access to Navy installations and facilities.
Please contact your Surveillance Officer on Contraction Officer's Representative (COR) for instructions when base access is required.
If a Surveillance Officer is not listed in the contract, please contact your Contracting Officer."
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 24-Aug-2018 02:00 PM to 27-Aug-2018 10:00 AM.
SUPPLIES OR SERVICES AND PRICES
CLIN 0006
The CLIN extended description has changed from:
Avigilon 360 Degree MP Panoramic Color Dome, model 8.0MP-HD-DOME-360 Bidding On: Manufacturer's Name:__________________________________________ Brand_______________________________________________________ No:_________________________________________________________
To:
Avigilon 360 Degree MP Panoramic Color Dome, model 12W-H3-4MH-DP1-B Bidding On: Manufacturer's Name:__________________________________________ Brand_______________________________________________________ No:_________________________________________________________ The pricing detail quantity has increased by 2.00 from 12.00 to 14.00.
CLIN 0008
The CLIN extended description has changed from:
Samsung 50’’ TV and Wall mount Bidding On: Manufacturer's Name:__________________________________________ Brand_______________________________________________________ No:_________________________________________________________
Samsung 50’’ TV and Wall mount. 2 workstations required: one at the quarterdeck with 2 monitor and one in office. Workstations must meet Navy IA requirement for software. Specs for workstation will be attached separately. Bidding On: Manufacturer's Name:__________________________________________ Brand_______________________________________________________ No:_________________________________________________________
DELIVERIES AND PERFORMANCE
The following Delivery Schedule item for CLIN 0006 has been changed from:
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
POP 24-SEP-2018 TO
26-DEC-2018
| N/A |
| NAVSUP FLC PUGET SOUND |
SEE AWARD INFO
SEE AWARD
BREMERTON WA
FOB: Destination N00406
| DELIVERY DATE |
| QUANTITY |
| SHIP TO ADDRESS |
| DODAAC / CAGE |
POP 24-SEP-2018 TO
26-DEC-2018
| N/A |
| NAVSUP FLC PUGET SOUND |
SEE AWARD INFO
SEE AWARD
BREMERTON WA
FOB: Destination N00406
(End of Summary of Changes) image1.wmf
File details come from the government source that posted it.