c_ <.( ~tv;:_,~

1. () uo .P.:f" l .R..b

US Department of Labor Material Safety Data Sheet May be used to comply with OSHA's Hazard Combination Standard 29 CFR 1910.1200. Standard must be consulted for specific requirements

Occupational Safety and Health Adm.

(Non-Mandatory Form) Form Approved: OMB No.1219-0072

NOTE: Blank spaces are not permitted. If any item is not applicable, or no information is available, the space must be marked to indicate that.

IDENTITY

Silver Chloride Magnesium Battery

Manufacture's Name Magnevolt Inc.

Address 5335 us Business 70 Clayton NC 25720

Emergency Telephone Number 919-790-9686

Telephone Number for Information 919-790-9686 Date Prepared 08/25/2011

SECTION II- Hazardous Ingredients/Identity Information

Hazardous Components: Common Name(s)) CAS No. OSHA PEL AACGIH TLV

Silver Chloride 7783-90-6 10 ug/m3 10 ug/m3

Magnesium 1309-48-4 15 mgs/m3 10 mgs/m3

(Under normal conditions of use or service this battery does not expose the user to toxic fumes.)

This product contains the following EPCRA Section 313 chemicals: Silver and its compounds.

SECTION III Physical/Chemical Characteristics

Boiling Point: NA Specific Gravity (H20 = 1: NA

Vapor Pressure (mm Hg.: NA Melting Point: 851 to 1220 deg F

Vapor Density(AIR = 1): NA Evaporation Rate: (Butyl Acetate 1): NA

Solubility in Water: NA Appearance and Odor: No Odor

SECTION IV - Fire and Explosion Hazard Data

Flash Point (Method Used) : NA Flammable Limits LEL: NA UEL: NA

Extinguishing Media: Dry Chemical Extinguisher

Special Fire Fighting Procedures: Avoid breathing fumes, wear self-contained breathing apparatus.

Unusual Fire and Explosion Hazards:

Intense heat and smoke from burning metal, plastic, and rubber components. When heated to a temperature near Magnesium's melting point, magnesium alloys ignite and burn with a white flame. Use of water on molten magnesium will produce hydrogen gas and may cause an explosion.

SECTION V - Reactivity Data

Stability: Normally Stable Unstable: Stable Condition to Avoid: NA

Incompatibility (Material to Avoid) : NA

Hazardous Decomposition or Byproducts: NA

Hazardous: NA May Occur: NA Condition to Avoid: NA

Polyizeration: Will Not Occur

SECTION VI - Health Hazard Data

Route(s) of Entry: Inhalation?: X Skin?: X Ingestion?: X

Health Hazards (acute and Cronic): Silver bio accumulates in human tissue.

Carcinogenicity: NTP?: No IARC Monographs?: NA OSHA Regulated?: No

Signs and Symptoms of Exposure

To Silver: Argyria

Medical Conditions: Generally Aggravated by Exposure: NA

Emergency and Fire Aid Procedures: Remove Injured personnel from area immediately .

SECTION VII - Precautions for Safe Handling and Use

Steps to be taken in Case Material is Released or Spilled: NA

Waste Disposal Method: Batteries contain silver and should be recycled in accordance with local, state and federal regulations.

Precautions to Be Taken in Handling and Storage: Avoid exposure to intense heat or fire.

SECTION VIII - Control Measures

Respiratory Protection (Specific Type) : NA Ventilation: Mechanical (General Local Exhaust: Yes Special:Other

Per ACGIH Handbook

Protective Gloves: Gloves Eye Protection: Goggles

Other Protective clothing or Equipment: NA

Work Hygiene Practices: Wash thoroughly after working with AGCL Batteries.

NOTICE:

The Data contained herein is based on information that Magnevolt believes to be reliable, but no expressed or implied warranty is made with regard to the accuracy of such data or its suitability for a given situation. Such data relates only to the specific product and not to such product in combination with any other product and no agent of Magnevolt is authorized to vary any of such data. Magnevolt Inc. and its agents disclaim all liability for any actions taken or foregone on reliance upon such data.

ABBREVIATIONS: ACGIH: American Conference of Government Industrial Hygienists CAS: Chemical Abstracts Service CFR: Code Of Federal Regulations CPR: Cardiopulmonary Resuscitation EPA: Environmental Protection Agency HMIS: Hazardous Material Identification System IARC: International Agency for Research on Cancer OSHA: Occupational Health and Safety Administration NTP: National Toxicology Program PEL: Permissible Exposure Limit PPE: Personal Protective Equipment SARA 313: Superfund Amendments and Reauthorization Act, Section 313 TLV: Threshold Limit Value TSCA: Toxic Substance Control Act WHMIS: Workplace Hazardous Materials Information System (Canada)