0109-02_-_Cisco_Flex_Pod_-_Bidding_DD254.pdf
PDF 2 MB Posted
- Attached to
- CISCO FLEXPOD Federal contract opportunity
- Solicitation number
- N0017819R2615
About this file
DD254
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 0109-02_-_Cisco_Flex_Pod_-__CDRL_A002.pdf | ||
| 0109-02_-_Cisco_Flex_Pod_-_TDP_Option_Selection_Worksheet.docx | DOCX document | |
| 0109-02_-_Cisco_Flex_Pod_-__DID_DI-SESS-81003.pdf | ||
| N0017819R2615_Solicitation.pdf | ||
| 0109-02_-_Cisco_Flex_Pod_-__CDRL_A001.pdf | ||
| 0109-02_-_Cisco_Flex_Pod_-__DID_DI-MISC-81356_A.pdf | ||
| N0017819R2615_Redacted_J&A.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Please wait...
If this message is not eventually replaced by the proper contents of the document, your PDF viewer may not be able to display this type of document.
You can upgrade to the latest version of Adobe Reader for Windows®, Mac, or Linux® by visiting http://www.adobe.com/go/reader_download.
For more assistance with Adobe Reader visit http://www.adobe.com/go/acrreader.
Windows is either a registered trademark or a trademark of Microsoft Corporation in the United States and/or other countries. Mac is a trademark of Apple Inc., registered in the United States and other countries. Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.
UNCLASSIFIED
BIDDING 006-19
CONTINUATION – DD FORM 254 BLOCK 13
BLOCK 13 CONTINUATION STATEMENTS:
1. CLASSIFIED OR UNCLASSIFIED TECHNICAL PAPERS TO BE PRESENTED AT A
CLASSIFIED SYMPOSIUM MUST BE APPROVED BY THE NSWCDD CONTRACTING
OFFICER'S REPRESENTATIVE PRIOR TO THE PRESENTATION.
2. SECURITY CLASSIFICATION GUIDES (SCG’s) AND UNCLASSIFIED LIMITED DOCUMENTS
(E.G., FOUO, DISTRIBUTION STATEMENT CONTROLLED) ARE NOT AUTHORIZED
FOR PUBLIC RELEASE; THEREFORE, THEY CAN NOT BE POSTED ON A PUBLICLY
ACCESSIBLE WEB SERVER OR TRANSMITTED OVER THE INTERNET UNLESS
APPROPRIATELY ENCRYPTED. REQUEST FOR PUBLIC RELEASE CANNOT BE
TRANSMITTED VIA THE INTERNET UNTIL THE CONTRACTOR RECEIVES FINAL
APPROVAL FROM THE COR.
3. ALL CONTRACTOR REQUESTS FOR SHARING OF CLASSIFIED AND OTHER
SENSITIVE INFORMATION BETWEEN PRIME CONTRACTS MUST BE FORWARDED IN
WRITING TO THE NSWCDD SECURITY OFFICE POC IDENTIFIED IN BLOCK 16 OF THIS
FORM FOR APPROVAL.
4. PERSONNEL DESIGNATED AS DERIVATIVE CLASSIFIERS SHALL RECEIVE DERIVATIVE
CLASSIFICATION TRAINING PRIOR TO ACCESS FROM THE CONTRACTOR'S FACILITY
SECURITY OFFICER (FSO). THE FSO SHALL ENSURE PERSONNEL RECEIVE INITIAL AND
BIENNIAL TRAINING DURING THE LIFE OF THIS CONTRACT. EVIDENCE OF COMPLETION,
TRAINING CERTIFICATES OR EQUIVALENT, SHALL BE PROVIDED TO THE INFORMATION
ASSURANCE MANAGER NO LATER THAN THE INDIVIDUAL'S DUE DATE.
5. ALL CLASSIFIED DOCUMENTS MUST BE DESTROYED USING A NATIONAL SECURITY
AGENCY (NSA) APPROVED HIGH SECURITY CROSSCUT SHREDDER LISTED ON THE
NSA/CSS EVALUATED PRODUCTS LIST(EPL) FOR HIGH SECURITY CROSSCUT PAPER
SHREDDERS, OR OTHER APPROVED METHOD FOR DESTROYING CLASSIFIED
INFORMATION.
6. ALL CLASSIFIED INFORMATION INVOLVED IN SECURITY INCIDENTS SHALL BE RETAINED
AND PROVIDED TO THE CERTIFYING OFFICIAL IN ITEM 16 OF THIS DD 254 FOR
CLASSIFICATION REVIEW.
7. ALL SECURITY RELATED ISSUES, INCIDENTS, OR REQUESTS PERTAINING TO THIS
CONTRACT SHALL BE PRESENTED IN WRITING BY THE CONTRACTOR'S FACILITY
SECURITY OFFICER (FSO) TO THE INDIVIDUAL IDENTIFIED IN BLOCK 16(A) OF THIS
DD254. THE CONTRACTOR SHALL ABIDE BY OTHER REPORTING REQUIREMENTS
OUTLINED IN THE NISPOM.
8. FORWARD A COPY OF SUBCONTRACTOR DD 254S ISSUED UNDER THIS CONTRACT TO
THE OFFICIAL SHOWN IN ITEM 16 OF THIS DD254.
FLEXPOD SELECT SYSTEMS
STATEMENT OF WORK (SOW)
1.0 BACKGROUND
Naval Surface Warfare Center Dahlgren Division, Dam Neck Activity
(NSWCDD DNA), is the lead for the Naval Sea Systems Command (NAVSEA)
Red Team (SEA-RT); a National Security Agency certified and United
States Cyber Command accredited. SEA-RT is responsible for performing cyber developmental testing for NAVSEA systems, warfare centers, and shipyards.
2.0 APPLICABLE DOCUMENTS
2.1 Parts List (attached for reference (appendix A).
2.2 Parts List sorted by hardware, software, and services (appendix
B).
3.0 REQUIREMENTS
3.1 The Contractor shall deliver a quantity of four (4) each
Flexpod Select systems, consisting of Cisco UCS C220M5 (Quantity 2), Nexus 3548 (Quantity 2), Catalyst 3650 (Quantity 1), and NetApp A220
(Quantity 1) to the NSWCDD DNA located in Virginia Beach.
3.2 The Contractor shall ensure that the parts list referenced in section 2.1 makes up a single Flexpod Select system.
3.3 The Contractor shall provide the one (1) Engineering Technician
IV that meets the following qualifications to assemble the Flexpod
Select rack:
3.3.1 Typical Education: Associates level degree in an
Electrical/Electronic Engineering, Engineering Technology, Physics or Mathematics.
3.3.2 Typical Experience: 5 years' work related experience in electrical/electronic systems. Independently plans and accomplishes complete projects or studies of broad scope and complexity or serves as an expert in a narrow aspect of a particular field of engineering, e.g., environmental factors affecting electronic engineering. Complexity of assignments typically requires considerable creativity and judgment to devise approaches to accomplish work, resolve design and operational problems, and make decisions in situations where standard engineering methods, procedures, and techniques may not be applicable. Supervisor or professional engineer provides advice on unusual or controversial problems or policy matters; completed work is reviewed for compliance with overall project objectives. May supervise or train and be assisted by lower level technicians.
BIDDING 006-19 UNCLASSIFIED
3.3.3 Performs, at this level, one or a combination of such typical duties as: Prepares designs and specifications for various complex equipment or systems (e.g., a heating system in an office building, or new electronic components such as solid state devices for instrumentation equipment).
3.3.4 Plans approach to solve design problems; conceives and
recommends new design techniques; resolves design problems with contract personnel, and assures compatibility of design with other parts of the system.
3.3.5 Designs and coordinates test set ups and experiments to prove or disprove the feasibility of preliminary design; uses untried and untested measurement techniques; and improves the performance of the equipment. May advise equipment users or redesign to solve unique operational deficiencies.
3.3.6 Plans approach and conducts various experiments to develop equipment or systems characterized by (a) difficult performance requirements because of conflicting attributes such as versatility, size, and ease of operation; or (b) unusual combination of techniques or components. Arranges for fabrication of pilot models and determines test procedures and design of special test equipment.
3.4 The Contractor shall provide the Flexpod Select racked and cabled per the standard Flexpod design specifications.
3.5 The Contractor shall provide the Flexpod Select with power and data cables ran in a redundant manner so there is no single point of failure.
3.6 The contractor shall test the systems to ensure operational capabilities are IAW OEM specifications.
3.7 The contractor shall coordinate with the technical point of contact (TPOC) listed below to schedule delivery and installation.
4.0 GOVERNMENT-FURNISHED PROPERTY/MATERIAL/INFORMATION (GFP/GFM/GFI)
4.1 There will be no GFP, GFM, or GFI provided.
5.0 SECURITY
5.1 All Key Personnel (i.e. program manager, integration
engineers, and service support employees) associated with this contract will be required to have at a minimum a DoD “Secret” clearance at time of award. The contractor will have access to information and compartments with a “Secret” classification. All deliverables associated with this contract are “unclassified” unless otherwise specified. Access to classified spaces and material and generation of classified material shall be in accordance with the attached DD Form 254. The only expected classified tasks will be during integration and services required at NSWCDD DNA and NSWCDD locations while performing installation and connections to the JMETC
MILS Network. All equipment at delivery is expected to by unclassified.
5.2 The Department of Defense Contract Security Classification
Specification (DD254) provides the security classification requirements for this effort. The contractor shall obtain personnel security clearances as required by the Department Industrial
Security Program prior to starting to work on tasks requiring clearances. Access to classified spaces and material shall be in accordance with the NISPOM and the NSWCDD Command Security Manual.
5.3 Non-government and/or personally owned portable electronic devices (PEDs) are prohibited in all NSWCDD buildings with the exception of personally owned cell phones which are authorized for use in spaces up to and including Controlled Access Areas. The
Contractor shall ensure the onsite personnel remain compliant with this PED policy. NSWCDD instruction defines PEDs as the following:
any electronic device designed to be easily transported, with the capability to store, record, receive or transmit text, images, video, or audio data in any format via any transmission medium.
PED’s include, but are not limited to, pagers, laptops, radios, compact discs and cassette players/recorders. In addition, this includes removable storage media such as flash memory, memory sticks, multimedia cards and secure digital cards, micro-drive modules, ZIP drives, ZIP disks, CD-RWs, DVD-RWs, MP3 players, iPADs, digital picture frames, electronic book readers, kindle, nook, cameras, external hard dish drives, and floppy diskettes.
5.3.1 PED’s belonging to an external organization shall not be connected to NSWCDD networks or infrastructure without prior approval from the NSWCDD Information Assurance and Compliance
Branch. This approval will be granted using the TARIS form and action tracker process.
5.3.2 Personally owned hardware or software shall not be connected or introduced to any NSWCDD hardware, network or information system infrastructure.
5.3.3 Facility Clearance: The Contractor shall possess and maintain a SECRET facility clearance as verified within the Industrial
Security Facility Database.
5.3.4 No classified work or discussions will occur at the contractor facility. All classified work and discussions will be conducted at
NSWCDD DNA or NSWCDD.
5.3.5 Electronic Spillages (ES) are unacceptable and pose a risk to national security. An electronic spillage is defined as classified data placed on an information system (IS), media or hardcopy document possessing insufficient security controls to protect the data at the required classification level, thus posing a risk to national security (e.g., sensitive compartmented information (SCI) onto collateral, Secret onto Unclassified, etc). The contractor's performance as it relates to ES will be evaluated by the Government.
ES reflects on the overall security posture of NSWCDD and a lack of attention to detail with regard to the handling of classified information of IS security discipline and will be reflected in the contractor's performance rating. In the event that a contractor is determined to be responsible for an ES, all direct and indirect costs incurred by the Government for ES remediation will be charged to the contractor.
5.3.5.1 NSWCDD Security will be responsible for the corrective action plan in accordance with the security guidance reflected on the DOD Contract Security Classification Specification - DD254.
NSWCDD Security will identify the contractor facility and contract number associated with all electronic spillages that involve the contractor. NSWCDD Security will notify the Contracts Division with the contractor facility name and contract number, incident specifics and associated costs for clean-up. The Contracting Officer will be responsible to work with the Contractor Facility to capture the costs incurred during the spillage clean up. The Contractor is also responsible for taking Information Security Awareness training annually, via their Facility Security Officer (FSO), as part of the mandatory training requirements. If a spillage occurs additional training will be required to prevent recurrence.
5.3.6 All Contractors (including Subcontractors) shall supplement their current security practices by requiring any personnel involved in executing this contract to complete Government-sponsored and administered Operations Security (OPSEC) training. In addition, all
Contractors should be aware of the Critical Information List (CIL) for the organization they are supporting as well as the OPSEC plan for NSWCDD. Upon contract award, all identified Contractors
(including Subcontractors) shall sign a Contractor's conformance statement and submit it to the NSWCDD COR named in block 13 of the attached DD-254 thereby acknowledging that they will meet the requirements of this contract. The COR shall contact their
Department Training Coordinator to schedule key employees to attend the Government-sponsored OPSEC training. The Contractor must immediately notify the Government upon the discovery of any nonconformance with the OPSEC Plan.
5.3.7 Privacy Program Training. Privacy training is mandatory for all NSWCDD personnel (military, civilian, and contractor) and must be completed annually. Total Workforce Management Services (TWMS) is the official database for workforce training and is the tool for taking and recording privacy act training. The contractor responsible for ensuring individual annual privacy training requirements are met.
6.0 TRAVEL
6.1 Integration of the Flexpods will be conducted at NAVAL Surface
Warfare Center Dahlgren Division, Dam Neck Activity and Naval
Surface Warfare Center Dahlgren Division. Expected time for integration is five (5) days at each location working normal working hours during the week.
7.0 DELIVERABLES
4.1 The Contractor shall provide drawings and lists IAW CDRL A001.
4.2 The Contractor shall provide a certificate of conformance IAW
CDRL A002.
8.0 TECHNICAL POINT OF CONTACT
Kris Walker
NSWCDD-DNA/R13
Address: Naval Surface Warfare Center, Dam Neck Activity
Building 127S, Room 249, Virginia Beach, VA 23461
Phone: 757-492-1057
Email: Kristopher.walker@navy.mil mailto:Kristopher.walker@navy.mil
Appendix A
NetApp
1 PS-TM-CONSLT-DAY-ZA PS Std Daily Consultant, ZA Exp.1yr from PO 3
2 AFF-A220-SYS-SC 1
3 AFF-A220A-002-SC AFF-A220A Flash Bundle 2
4 SW-2-A220A-TPM-C SW,Trusted Platform Module Enabled,A220,-C 2
5 SW-2-A220A-NVE-C SW,Data at Rest Encryption Enabled,A220,-C 2
6 AFF-A220A-EXP-109 AFF-A220,HA,12X3.8TB SSD,Flash Bundle,NVE 1
7 X800-42U-R6 Power Cable,In-Cabinet,C13-C14 2
8 X-02659-00 Rail Kit,4-Post,Rnd/Sq-Hole,Adj,24-32 1
9 X-SFP-H10GB-CU1M-R6 Cable,Cisco 10GBase Copper SFP+ 1m 8
10 DATA-AT-REST-ENCRYPTION Data at Rest Encryption Capable Operating Sys 2
11 SW-FLASH-01-P SW,Per-0.1TB,Flash,01,-P 456
12 CS-MV-CI-FLEXPOD FlexPod Support 1
13 CS-BASE-SUPPORT Base Software Support 36 months 1
14 CS-SEC-NBDD SE Secure,Next Bus Day Parts Delivery 12 months 1
15 CS-NRD2-G Non Returnable Disk Plus,g 12 months 1
16 SW-2-CL-BASE SW-2,Base,CL,Node 1
17 X-SFP-H10GB-CU1M-R6 Cable,Cisco 10GBase Copper SFP+ 1m 8
NetApp Subtotal 1
Item Part Number Description Service Length Qty
Cisco
18 C1-N3K-C3548X Cisco ONE Nexus 3548X, 48 SFP+ ports 12 Months 2
19 CON-SSSNT-C1N3KC48 SOLN SUPP 8X5XNBD Cisco ONE Nexus 3548X, 48 SFP+ ports 12 Months 2
20 N3K-C3064-ACC-KIT Nexus 3K/9K Fixed Accessory Kit 2
21 N3548-BAS1K9 Nexus 3500 Base License 2
22 NXA-FAN-30CFM-F Nexus 2K/3K/9K Single Fan port side exhaust airflow 8
23 C1F1PNEX35481K9 Cisco ONE Foundation Perpetual Nexus 3548 12 Months 2
24 CON-ECMUS-CFX35481 SOLN SUPP SWSS Cisco ONE Foundation Perpetual Nexus 3548 12 Months 2
25 N3548-LAN1K9 Nexus 3548 Layer 3 LAN Enterprise License 2
26 C1-NDB-SWT-K9 Cisco ONE Tap/SPAN Agg lic for 1 Cisco Nexus Switch 27 Months 2
27 N3548-ALGK9 Nexus 3500 Algo Boost License 2
28 C1-DCL-N3K-K9 Cisco ONE DCNM for LAN Advanced Edt. for Nexus 3000 27 Months 2
29 N2200-PAC-400W N2K/N3K AC Power Supply, Std airflow (port side exhaust) 4
30 CAB-9K12A-NA Power Cord 125VAC 13A NEMA 5-15 Plug North America 4
31 NXOS-703I7.5 Nexus 9500, 9300, 3000 Base NX-OS Software Rel 7.0(3)I7(5) 2
32 UCSC-C220-M5SX UCS C220 M5 SFF 10 HD w/o CPU, mem, HD, PCIe, PSU 2
33 CON-OSP-C220M5SX SNTC 24X7X4OS UCS C220 M5 SFF 10 HD w/o CPU, mem, HD, PCIe, 12 Months 2
34 UCSC-MLOM-C40Q-03 NOT PROVIDED FOR THIS UPDATE 2
35 CIMC-LATEST IMC SW (Recommended) latest release for C-Series Servers. 2
36 UCSC-PSU1-770W 770W AC Hot-Plug Power Supply for 1U C-Series Rack Server 4
37 CAB-9K12A-NA Power Cord 125VAC 13A NEMA 5-15 Plug North America 4
38 UCSC-RAILB-M4 Ball Bearing Rail Kit for C220 & C240 M4 & M5 rack servers 2
39 UCSC-BBLKD-S2 UCS C-Series M5 SFF drive blanking panel 20
40 UCS-SD-64G-S 64GB SD Card for UCS Servers 4
41 UCSC-SATAIN-220M5 C220 M5 (8-drive) SATA Interposer board 2
42 UCS-MSTOR-SD Mini Storage Carrier for SD (holds up to 2) 2
43 UCS-SID-INFR-CFP Converged-FlexPod 2
44 UCS-SID-WKL-UNK Unknown (Description per CISCO's Site) 2
45 UCS-MR-X32G2RS-H 32GB DDR4-2666-MHz RDIMM/PC4-21300/dual rank/x4/1.2v 32
46 UCS-CPU-6142 2.6 GHz 6142/150W 16C/22MB Cache/DDR4 2666MHz 4
47 UCSC-HS-C220M5 Heat sink for UCS C220 M5 rack servers 150W CPUs & below 4
48 CVR-QSFP-SFP10G= QSFP to SFP10G adapter 4
49 SFP-H10GB-CU1M= 10GBASE-CU SFP+ Cable 1 Meter 4
50 SFP-10G-SR-S= 10GBASE-SR SFP Module Enterprise-Class 2
51 C9300-48P-E Catalyst 9300 48-port PoE+, Network Essentials 1
52 CON-SSSNT-C93004PE SOLN SUPP 8X5XNBD Catalyst 9300 48-port PoE+, Network Esse 12 Months 1
53 C9300-NW-E-48 C9300 Network Essentials 48-port license 1
54 S9300UK9-168 Universal 1
55 PWR-C1-715WAC 715W AC Config 1 Power Supply 1
56 CAB-TA-NA North America AC Type A Power Cable 2
57 STACK-T1-50CM 50CM Type 1 Stacking Cable 1
58 CAB-SPWR-30CM Catalyst Stack Power Cable 30 CM 1
59 C9300-DNA-E-48 C9300 DNA Essentials, 48-Port Term Licenses 1
60 C9300-DNA-E-48-3Y C9300 DNA Essentials, 48-port, 3 Year Term license 36 Month 1
61 C9300-NM-8X Catalyst 9300 8 x 10GE Network Module 1
62 PWR-C1-715WAC/2 715W AC Config 1 Secondary Power Supply 1
Cisco Subtotal 1
Item Part Number Description Covered Product Qty
PDU, UPS and Integration
66 AP7800B Rack PDU, Metered, 1U, 15A, 100/120V, (8) 5-15 2
67 SMX3000RMLV2UNC APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V with Network Card 1
68 AR3104SP1 NetShelter SX 24U 600mm Wide x 1070mm Deep Enclosure - 1250 lbs. Shock Packaging 1
69 Integration 1
PDU, UPS and Integration Subtotal 1
Quoted Total
Shipping Cost
Grand Total
Appendix B
Item Part Number Description Service Length Qty Hardware/Software/Services
18 C1-N3K-C3548X Cisco ONE Nexus 3548X, 48 SFP+ ports 12 Months 2 Hardware
19 CON-SSSNT-C1N3KC48 SOLN SUPP 8X5XNBD Cisco ONE Nexus 3548X, 48 SFP+ ports 12 Months 2 Hardware
20 N3K-C3064-ACC-KIT Nexus 3K/9K Fixed Accessory Kit 2 Hardware
21 N3548-BAS1K9 Nexus 3500 Base License 2 Hardware
22 NXA-FAN-30CFM-F Nexus 2K/3K/9K Single Fan port side exhaust airflow 8 Hardware
25 N3548-LAN1K9 Nexus 3548 Layer 3 LAN Enterprise License 2 Hardware
26 C1-NDB-SWT-K9 Cisco ONE Tap/SPAN Agg lic for 1 Cisco Nexus Switch 27 Months 2 Hardware
27 N3548-ALGK9 Nexus 3500 Algo Boost License 2 Hardware
28 C1-DCL-N3K-K9 Cisco ONE DCNM for LAN Advanced Edt. for Nexus 3000 27 Months 2 Hardware
29 N2200-PAC-400W N2K/N3K AC Power Supply, Std airflow (port side exhaust) 4 Hardware
30 CAB-9K12A-NA Power Cord 125VAC 13A NEMA 5-15 Plug North America 4 Hardware
31 NXOS-703I7.5 Nexus 9500, 9300, 3000 Base NX-OS Software Rel 7.0(3)I7(5) 2 Hardware
32 UCSC-C220-M5SX UCS C220 M5 SFF 10 HD w/o CPU, mem, HD, PCIe, PSU 2 Hardware
33 CON-OSP-C220M5SX SNTC 24X7X4OS UCS C220 M5 SFF 10 HD w/o CPU, mem, HD, PCIe, 12 Months 2 Hardware
34 UCSC-MLOM-C40Q-03 NOT PROVIDED FOR THIS UPDATE 2 Hardware
36 UCSC-PSU1-770W 770W AC Hot-Plug Power Supply for 1U C-Series Rack Server 4 Hardware
37 CAB-9K12A-NA Power Cord 125VAC 13A NEMA 5-15 Plug North America 4 Hardware
38 UCSC-RAILB-M4 Ball Bearing Rail Kit for C220 & C240 M4 & M5 rack servers 2 Hardware
39 UCSC-BBLKD-S2 UCS C-Series M5 SFF drive blanking panel 20 Hardware
40 UCS-SD-64G-S 64GB SD Card for UCS Servers 4 Hardware
41 UCSC-SATAIN-220M5 C220 M5 (8-drive) SATA Interposer board 2 Hardware
42 UCS-MSTOR-SD Mini Storage Carrier for SD (holds up to 2) 2 Hardware
43 UCS-SID-INFR-CFP Converged-FlexPod 2 Hardware
44 UCS-SID-WKL-UNK Unknown (Description per CISCO's Site) 2 Hardware
45 UCS-MR-X32G2RS-H 32GB DDR4-2666-MHz RDIMM/PC4-21300/dual rank/x4/1.2v 32 Hardware
46 UCS-CPU-6142 2.6 GHz 6142/150W 16C/22MB Cache/DDR4 2666MHz 4 Hardware
47 UCSC-HS-C220M5 Heat sink for UCS C220 M5 rack servers 150W CPUs & below 4 Hardware
48 CVR-QSFP-SFP10G= QSFP to SFP10G adapter 4 Hardware
49 SFP-H10GB-CU1M= 10GBASE-CU SFP+ Cable 1 Meter 4 Hardware
50 SFP-10G-SR-S= 10GBASE-SR SFP Module Enterprise-Class 2 Hardware
51 C9300-48P-E Catalyst 9300 48-port PoE+, Network Essentials 1 Hardware
52 CON-SSSNT-C93004PE SOLN SUPP 8X5XNBD Catalyst 9300 48-port PoE+, Network Esse 12 Months 1 Hardware
54 S9300UK9-168 Universal 1 Hardware
55 PWR-C1-715WAC 715W AC Config 1 Power Supply 1 Hardware
56 CAB-TA-NA North America AC Type A Power Cable 2 Hardware
57 STACK-T1-50CM 50CM Type 1 Stacking Cable 1 Hardware
58 CAB-SPWR-30CM Catalyst Stack Power Cable 30 CM 1 Hardware
61 C9300-NM-8X Catalyst 9300 8 x 10GE Network Module 1 Hardware
62 PWR-C1-715WAC/2 715W AC Config 1 Secondary Power Supply 1 Hardware
66 AP7800B Rack PDU, Metered, 1U, 15A, 100/120V, (8) 5-15 2 Hardware
67 SMX3000RMLV2UNC APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V with Network Card 1 Hardware
68 AR3104SP1 NetShelter SX 24U 600mm Wide x 1070mm Deep Enclosure - 1250 lbs. Shock Packaging 1 Hardware
2 AFF-A220-SYS-SC 1 Hardware
3 AFF-A220A-002-SC AFF-A220A Flash Bundle 2 Hardware
6 AFF-A220A-EXP-109 AFF-A220,HA,12X3.8TB SSD,Flash Bundle,NVE 1 Hardware
7 X800-42U-R6 Power Cable,In-Cabinet,C13-C14 2 Hardware
8 X-02659-00 Rail Kit,4-Post,Rnd/Sq-Hole,Adj,24-32 1 Hardware
9 X-SFP-H10GB-CU1M-R6 Cable,Cisco 10GBase Copper SFP+ 1m 8 Hardware
12 CS-MV-CI-FLEXPOD FlexPod Support 1 Hardware
13 CS-BASE-SUPPORT Base Software Support 36 months 1 Hardware
14 CS-SEC-NBDD SE Secure,Next Bus Day Parts Delivery 12 months 1 Hardware
15 CS-NRD2-G Non Returnable Disk Plus,g 12 months 1 Hardware
17 X-SFP-H10GB-CU1M-R6 Cable,Cisco 10GBase Copper SFP+ 1m 8 Hardware
NetApp Subtotal 1 Hardware
1 PS-TM-CONSLT-DAY-ZA PS Std Daily Consultant, ZA Exp.1yr from PO 3 Services
69 Integration 1 Services
4 SW-2-A220A-TPM-C SW,Trusted Platform Module Enabled,A220,-C 2 Software
5 SW-2-A220A-NVE-C SW,Data at Rest Encryption Enabled,A220,-C 2 Software
10 DATA-AT-REST-ENCRYPTION Data at Rest Encryption Capable Operating Sys 2 Software
11 SW-FLASH-01-P SW,Per-0.1TB,Flash,01,-P 456 Software
16 SW-2-CL-BASE SW-2,Base,CL,Node 1 Software
23 C1F1PNEX35481K9 Cisco ONE Foundation Perpetual Nexus 3548 12 Months 2 Software
24 CON-ECMUS-CFX35481 SOLN SUPP SWSS Cisco ONE Foundation Perpetual Nexus 3548 12 Months 2 Software
35 CIMC-LATEST IMC SW (Recommended) latest release for C-Series Servers. 2 Software
53 C9300-NW-E-48 C9300 Network Essentials 48-port license 1 Software
59 C9300-DNA-E-48 C9300 DNA Essentials, 48-Port Term Licenses 1 Software
60 C9300-DNA-E-48-3Y C9300 DNA Essentials, 48-port, 3 Year Term license 36 Month 1 Software
DRAFT
SAMPLE
PREVIOUS EDITION IS OBSOLETE.
Page of AEM LiveCycle Designer
DD FORM 254, APR 2018
NEEDS DD67
DEPARTMENT OF DEFENSE
CONTRACT SECURITY CLASSIFICATION SPECIFICATION
(The requirements of the National Industrial Security Program (NISP) apply to all security aspects of this effort involving classified information.)
OMB No. 0704-0567 OMB approval expires:
October 31, 2020 The public reporting burden for this collection of information, 0704-0567, is estimated to average 70 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to the Department of Defense, Washington Headquarters Services, at whs.mc-alex.esd.mbx.dd-dod-information-collections@mail.mil. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.
RETURN COMPLETED FORM AS DIRECTED IN THE INSTRUCTIONS.
1. CLEARANCE AND SAFEGUARDING
2. THIS SPECIFICATION IS FOR: (X and complete as applicable.)
3. THIS SPECIFICATION IS: (X and complete as applicable.)
a. ORIGINAL (Complete date in all cases.)
b. REVISED (Supersedes all previous specifications.)
4. IS THIS A FOLLOW-ON CONTRACT?
If yes, complete the following:
Classified material received or generated under
5. IS THIS A FINAL DD FORM 254?
If yes, complete the following:
6. CONTRACTOR (Include Commercial and Government Entity (CAGE) Code)
7. SUBCONTRACTOR(S) (Click button if you choose to add or list the subcontractors -- but will still require a separate DD Form 254 issued by a prime contractor to each subcontractor)
8. ACTUAL PERFORMANCE (Click button to add more locations.)
10. CONTRACTOR WILL REQUIRE ACCESS TO: (X all that apply. Provide details in Blocks 13 or 14 as set forth in the instructions.)
e. NATIONAL INTELLIGENCE INFORMATION:
11. IN PERFORMING THIS CONTRACT, THE CONTRACTOR WILL: (X all that apply. See instructions. Provide details in Blocks 13 or 14 as set forth in the instructions.)
12. PUBLIC RELEASE
Any information (classified or unclassified) pertaining to this contract shall not be released for public dissemination except as provided by the National Industrial Security Program Operating Manual (NISPOM) or unless it has been approved for public release by appropriate U.S. Government authority. Proposed public releases shall be submitted for review and approval prior to release to the appropriate government approval authority identified here with at least office and phone contact information and if available, an e-mail address. (See instructions)
13. SECURITY GUIDANCE
The security classification guidance for classified information needed for this effort is identified below. If any difficulty is encountered in applying this guidance or if any other contributing factor indicates a need for changes in this guidance, the contractor is authorized and encouraged to provide recommended changes; to challenge the guidance or the classification assigned to any information or material furnished or generated under this contract; and to submit any questions for interpretation of this guidance to the official identified below. Pending final decision, the information involved shall be handled and protected at the highest level of classification assigned or recommended.
(Fill in as appropriate for the classified effort. Attach, or forward under separate correspondence, any documents/guides/extracts referenced herein. The field will expand as text is added. When removing any expanded text area, use delete key or backspace key, then click out of the text field for it to shrink after the text has been deleted. Also allows for up to 6 internal reviewers to digitally sign. See instructions for additional guidance or use of the fillable PDF.)
14. ADDITIONAL SECURITY REQUIREMENTS
Requirements, in addition to NISPOM requirements for classified information, are established for this contract.
If Yes, identify the pertinent contractual clauses in the contract document itself, or provide an appropriate statement which identifies the additional requirements. Provide a copy of the requirements to the CSO. The field will expand as text is added or you can also use item 13. When removing any expanded text area, use delete key or backspace key, then click out of the text field for it to shrink after the text has been deleted. (See instructions for additional guidance or use of the fillable PDF.)
15. INSPECTIONS
Elements of this contract are outside the inspection responsibility of the CSO.
If Yes, explain and identify specific areas and government activity responsible for inspections. The field will expand as text is added or you can also use item 13. When removing any expanded text area, use delete key or backspace key, then click out of the text field for it to shrink after the text has been deleted. (See instructions for additional guidance or use of the fillable PDF.)
16. GOVERNMENT CONTRACTING ACTIVITY (GCA) AND POINT OF CONTACT (POC)
17. CERTIFICATION AND SIGNATURES
Security requirements stated herein are complete and adequate for safeguarding the classified information to be released or generated under this classified effort. All questions shall be referred to the official named below. Upon digitally signing Item 17h, no changes can be made as the form will be locked.
18. REQUIRED DISTRIBUTION BY THE CERTIFYING OFFICIAL
9.0.0.2.20120627.2.874785 DD 254, DoD Contract Security Classification Specification List of Attachments [3] (All Files Must be Attached Prior to Signing, i.e., for any digital signature on the form) CONTINUATION STATEMENTS.pdf CUI.pdf SOW Bidding 006-19_Updated 6 Feb 2019.pdf
| CurrentPage: |
| PageCount: |
| Classification: Unclassified |
| SerialNum: |
| a. Facility clearance level. Select one.: 2 |
| b. Level of safeguarding for classified information/material required at contractor facility. Select one.: 4 |
| Choose Yes or No: 0 |
| Choose Yes or No: 1 |
| Prime: |
| Choose Yes or No: 0 |
| Choose Yes or No: 0 |
| Sub: |
| Choose Yes or No: 1 |
| Choose Yes or No: 0 |
| Soli: BIDDING 006-19 |
| DueDate: |
| dateA: 2019-02-04 |
| RevisionNum: |
| dateB: |
| Final: |
| dateC: |
| No: 1 |
| No: 1 |
| No: 1 |
| No: 1 |
| Yes: 0 |
| Yes: 0 |
| Yes: 0 |
| Yes: 0 |
| Enter your name here.: |
| ReqDated: |
| Enter your name here.: |
| Name: |
THIS DD254 IS FOR BIDDING PURPOSES ONLY
| Name: Malaguti, Sherrie |
| Cage: |
| CSO: |
THIS DD254 IS A GUIDE FOR BIDDING PURPOSES ONLY. AN ORIGINAL DD254 WILL BE ISSUED UPON AWARD OF CONTRACT.
| addrow: |
| Removerow: |
| Click to delete a row: |
| Location: Naval Surface Warfare Center Dahlgren Division |
Dahlgren, VA 22448 Location: NSWC Dahlgren Division Dam Neck Activity Virginia Beach, VA 23461
| Block9: This procurement is to procure and deliver four flexPODs at NSWC Dam Neck Activity, Virgina Beach, VA. Two of the flexPODs will be connected to the Secret Domain using the JMETC MILS Network while the other two FlexPODs will remain unclassified. |
| a: 0 |
| a: 1 |
| a: 1 |
| f: 0 |
| f: 0 |
| f: 1 |
| b: 0 |
| b: 0 |
| b: 0 |
| g: 0 |
| g: 0 |
| c: 0 |
| c: 0 |
| c: 1 |
| h: 0 |
| h: 0 |
| d: 0 |
| d: 0 |
| d: 0 |
| i: 0 |
| i: 0 |
| SCI: 0 |
| NonSCI: 0 |
| j: 1 |
| j: 0 |
| k: 1 |
| k: 0 |
| Enter your name here.: Access to the JMETC MILS Network Domain |
| Enter your name here.: Provide technical services to connect two flexPODs to the JMETC MILS Network domain. |
| e: 1 |
| e: 1 |
| l: 1 |
| m: 1 |
| direct: 0 |
| thru: 0 |
| Enter your name here.: |
| PublicAuthority: None Authorized |
| AddSig: |
| RemoveSig: |
| text: 1. National Industrial Security Program Operating Manual (NISPOM), Feb 2006, Incorporating Changes, May 18, 2016 applies to this |
contract.
2. The contractor is not authorized to release any data to foreign nationals or foreign representatives without an approved export license.
3. Block 10j: CUI encompasses what was previously stated as FOUO and PII. DoD components refer to DoDM 5200.01, VOL 4, "DoD Information Security Program: Controlled Unclassified Information (CUI)," available at http://www.esd.whs.mil/DD/DoD-Issuances/ when considering protection for CUI.
4. Block 10k: Classified tasks will be during integration and services required at NSWCDD DNA and NSWCDD Dahlgren VA locations while performing installation and connections to the JMETC MILS Network.
5. Block 11a: Contract Performance is restricted to: Naval Surface Warfare Center Dahlgren VA and Naval Surface Warfare Center Dahlgren Division, Dam Neck Activity, Virginia Beach VA.
6. Block 11e: Contract is for equipment installation services on equipment which processes classified information. Actual knowledge of, generation, or production of classified information is not required for performance of the contract. Cleared personnel are required to perform this service because visual or aural access to classified information cannot be precluded by escorting personnel. Any classification guides will be provided by the using activity.
7. Block 11l: CUI encompasses what was previously stated as FOUO and PII. DoD components refer to DoDM 5200.01, VOL 4, "DoD Information Security Program: Controlled Unclassified Information (CUI)," available at http://www.esd.whs.mil/DD/DoD-Issuances/ when considering protection for CUI.
8. Block 11m: Contractor will deliver and install Flexpod Select systems to be connected to the JMETC MILS Network.
9. See attachments for additional security guidance.
| attachmentsList: |
| AddAttachment: |
| ViewAttachment: |
| RemoveAttachment: |
| rep: |
| Sig: |
| Enter your name here.: |
| GCAName: Naval Surface Warfare Center Dahlgren Div |
| AAC: N00178 |
| AAC: N00178 |
| Address: 18372 Frontage Road, Suite 318 |
Dahlgren, VA 22448 Address: Naval Surface Warfare Center, Dahlgren Division 6146 Tisdale Road, Suite 237 Dahlgren, VA 22448-5158
| POCName: John Jims |
| Phone: 5406537105 |
| Phone: 5406532487 |
| Email: john.jims@navy.mil |
| Email: sherrie.malaguti@navy.mil |
| Title: Security Contracting Officer |
| Enter the date using the format DD-Mon-YYYY: 20190222 |
File details come from the government source that posted it.