Solicitation Amendment N0016725Q11220001 SF 30.pdf

PDF 572 KB Posted

Attached to
Novanta (ATI) small form factor 6-axis force and torque transducer Federal contract opportunity
Solicitation number
N0016725Q1122
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This is a Standard Form 30 Amendment of Solicitation/Modification of Contract for a Navy contract (N0016725Q1122) issued by NSWC Carderock Division. The amendment extends the response due date from 18 Aug 2025 to 26 Aug 2025 due to changes in specifications. The primary modification involves CLIN 0001, which specifies a Nano25 F/T Transducer with a key change from a radial-exit to an axial-exit 1.8m cable, while maintaining the same technical specifications. The transducer is a 6-axis sensor capable of measuring forces up to 250N in Fx and Fy, 1000N in Fz, and torques up to 6Nm in Tx and Ty, 3.4Nm in Tz, with an IP68 rating for freshwater use to 2 meters depth. The sensor has specific dimensional and mounting requirements, including a 28mm diameter cylindrical body, M3x0.5 tapped holes, and 3mm dowel holes.

View the file

Other files for this federal contract opportunity

Other files attached to Novanta (ATI) small form factor 6-axis force and torque transducer, newest first.
File Type Posted
SF 1449 - N0016725Q11220001.pdf PDF
brand name justification.docx DOCX document
SF 1449 - N0016725Q1122.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

16C. DATE SIGNED

Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBE

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

Section A - Solicitation/Contract Form

The following changes have been made:

INFORMATION FROM TO

Response Due Date 18 Aug 2025 26 Aug 2025

N0016725Q11220001

Section B - Supplies or Services & Prices or Costs

The following CLIN(s) / SLIN(s) / ELIN(s) were modified:

INFORMATION FROM TO CHANGED

BY

Description

1. Nano25 F/T Transducer with radial-exit 1.8m cable with IP68 protection- QTY: 4 - Sensor that measures force and torque in 6-axes that measure up to 250N in Fx, 250N in Fy, 1000N in Fz, 6Nm in Tx, 6Nm in Ty, and 3.4Nm in Tz.

- IP68 Rated for use in freshwater to at least 2 meters in depth- Sensor body must be cylindrical in shape with a 28mm diameter and 27.6mm in length- Cable must exit the sensor axially along the cylindrical direction.- Cable must be at least 1.5 meters in length.- Sensor must have (3) M3x0.5 holes tapped to 4.5mm in depth and be equally spaced on a 20.3mm bolt circle on the cable exit side of the sensor body.- Sensor must have (3) M3x0.5 holes tapped to 3.0 mm in depth and be equally spaced on a 20.3 mm bolt circle on the non-cable exit side of the sensor body.- Sensor must have (2) 3mm slip fit dowel holes spaced 120deg on both sides of the sensor body.

1. Nano25 F/T Transducer with axial-exit 1.8m cable with IP68 protection- QTY: 4 - Sensor that measures force and torque in 6-axes that measure up to 250N in Fx, 250N in Fy, 1000N in Fz, 6Nm in Tx, 6Nm in Ty, and 3.4Nm in Tz.

- IP68 Rated for use in freshwater to at least 2 meters in depth- Sensor body must be cylindrical in shape with a 28mm diameter and 27.6mm in length- Cable must exit the sensor axially along the cylindrical direction.- Cable must be at least 1.5 meters in length.- Sensor must have (3) M3x0.5 holes tapped to 4.5mm in depth and be equally spaced on a 20.3mm bolt circle on the cable exit side of the sensor body.- Sensor must have (3) M3x0.5 holes tapped to 3.0 mm in depth and be equally spaced on a 20.3 mm bolt circle on the non-cable exit side of the sensor body.- Sensor must have (2) 3mm slip fit dowel holes spaced 120deg on both sides of the sensor body.

N0016725Q11220001

IDCode: J
Page: 1
Pages: 3
AmendNo: 0001
EffDate: 19 Aug 2025
ReqNo: See Continuation Sheet
ProjNo:
IssCode: N00167
AdmCode:
IssuedBy: NSWC CARDEROCK

CARDEROCK DIVISION, 9500 MACARTHUR BOULEVARD

BETHESDA, MD 20817-5700

UNITED STATES

STEVEN BESANKO, Email: steven.w.besanko.civ@us.navy.mil Telephone: 301-312-3357 AdminBy:

SCD: PAS:

ContractorNameAdd:
Code:
FacCode:
SolChg: 1
SolNo: N0016725Q1122
SolDate: 04 Aug 2025
AwardChg: Off
AwardNo:
AwardDate:
Amended: 1
OffrExt: 1
OffrNoEx: Off
NoCopies: 1
ApprData: See Section G - Contract Administration Data
ChgeOrd: Off
ChgeOrder:
Modify: Off
SuppAgre: Off
SuppAuth:
ModOthr: Off
OthrSpec:
NoReq: Off
Require: Off
Copies:
Descript: The purpose of this amendment is to extend the solicitation date to 8/26 due to a change in specifications. All other terms and conditions are the same.