Amendment N0016721Q0231_0001.pdf

PDF 613 KB Posted

Attached to
BNC to Microdot Cables Federal contract opportunity
Solicitation number
N0016721Q0231
Issued by
Department of the Navy Naval Sea Systems Command

View the file

Other files for this federal contract opportunity

Other files attached to BNC to Microdot Cables, newest first.
File Type Posted
Combined_N016721Q0231.pdf PDF
Minimum Specifications.pdf PDF
Reference Drawing.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1300946450

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

This solicitation is hereby amended to add the below clarification to the Minimum Specif ications technical evaluation factors. All other items remain unchanged.

“As substitute of testing vendors may provide proof (Contract Number) of past performance w here product w as tested by NAVSEA.”

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 05-Aug-2021

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N0016721Q0231

X 9B. DATED (SEE ITEM 11)

26-Jul-2021

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

05-Aug-2021

CODE

NAVAL SURFACE WARFARE CENTER CARDEROCK

MICHAEL S. BRODIE

757-410-0370 MICHAEL.S.BRODIE@NAVY.MIL

904 CORPORATE LANE

CHESAPEAKE VA 23320

N00167 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

N0016721Q0231

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

The following have been modified:

MINIMUM SPECIFICATIONS

Minimum Specifications

CABLE: Enviroflex 316-D cable or equivalent 80’’ in length 3’’ of double wall heat shrink from each connector

CONNECTOR 1: BNC - AMPHENAOL 31-315

CONNECTOR 2: Microdot - PN: 5-1532005-0 & PN: 132-0114-0003 NOTE: May be microdot or equal. The TYPE of connection needs to be microdot. BRAND NAME not required

*** As substitute of testing vendors may provide proof (Contract Number) of past performance where product was tested by NAVSEA. ***

C713/C716 requests the following technical factors in order to verify a quality product:

- Provide an image of the actual cable that will be provided (no stock images)

- Provide written confirmation by a subject matter expert of the following features of the cable o Confirm materials of construction and crimping features match Notes 1 and 2 on page 2 of the provided technical drawing. If they do not match exactly, provide explanation for why.

o Confirm specifications on page 3 of provided technical drawing match. If they do not match exactly, provide explanation for why.

o Confirm the length of the double heat wall shrink on the cable in inches.

- Verify that the BNC connection and microdot connection cannot be easily separated from the cable.

o Perform a tensile strength or stress test to provide a force measurement that the ends can withstand prior to failure.

- Verify no existence of sound shorts within the cable through a voltmeter resistance test i.e.

verify the shielding wire is quality and is not in contact with the signal wires to cause a short even with adjusting/jiggling the wire. (Y/N)

- Verify the flexibility and resilience of the cable.

o Provide the minimum bending radius (Static, repeated and dynamic) at the double heat wall shrink section of the cable.

- Verify that the double heat wall shrink cannot be easily slid down the cable disconnecting from the end. (Y/N)

N0016721Q0231

(End of Summary of Changes)