Att 2 DRAFT NAVFAC 30OP Skimmer Specification Response Matrix.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- OSR OP Skimmer Federal contract opportunity
- Solicitation number
- N00024-22-R-2287
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Att 3 DRAFT 30OP Skimmer Initial Spares.xlsx | XLSX spreadsheet | |
| Att_7_- Technical Data Rights Assertion.doc | DOC document | |
| Solicitation.docx | DOCX document | |
| Att 1 NAVFAC Skimmer Specification 02FEB2022.pdf | ||
| Att_5_-_DRAFT Delivery Schedule.XLS | XLS spreadsheet | |
| Att 8 FPSL Past Performance and Experience.doc | DOC document | |
| Att_4_-_Unique_Item_Identification_(UID).doc | DOC document | |
| Att_6_-_Warranty Terms.doc | DOC document | |
| Draft Solicitation 12-16-21.docx | DOCX document | |
| DRAFT_Att1_2020-006 NAVFAC Skimmer Specification_10DEC2021.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Att 1 Spec Response Matrix
| ATTACHMENT 2 |
| Naval Facilities (NAVFAC), Oil Spill Response (OSR) |
Oil Pollution Skimmer
SPECIFICATION RESPONSE MATRIX
NOTES & INSTRUCTIONS:
Offerors to submit Attachment 2 with response for parameters identified in the Specification (See Section J).
1. Where specific parameters or other technical information are required in the Specification (indicated by red text in the Specification), Offerors shall fill in the specific parameters/information for their proposed design for each boat configuration (as applicable) in this attachment and include supporting data in Vol I as directed. At bottom Offerors shall respond with 'Comply' to indicate their design meets all Specification requirements; or 'Comply w/Exceptions' to indicate disagreement with any specific section of the Specification.
2. A response of 'Comply w/Exceptions' shall be accompanied by amplifying notes in the 'Offeror's Notes' section at bottom, providing rationale for any exceptions. Each exception shall list the Specification section, the specific rationale for non-compliance with the section, and a proposed alternative approach. Any proposed alternative approach must meet the minimum requirement of the Specification to the Government's satisfaction. Description of Offeror's alternative approach shall include the detailed approach to achieving the minimum Specification requirement; applicable material specifications, make and model numbers for all parts/components; compliance with any requisite commercial or military standard, or associated “best practice”; and shall include any supporting product performance, test data, or other empirical evidence for the proposed product or service capability where applicable. The Government reserves the right to reject (without discussion) any proposed alternative which is incomplete or fails to meet minimum requirements of the Specification.
3. A response is required for each Specification section identified herein. The Government reserves the right to evaluate incomplete responses as non-compliant with the Specification and unacceptable for Factor 1 (Technical Approach).
| Specification Item | Specification Parameter | Offeror Response |
| 070-1 | Enter Length Overall (LOA) including appendages: xx.xx ft | |
| 070-1 | Enter Hull Length (Lhull) : xx.xx ft | |
| 070-1 | Enter Beam Overall (BOA) [Shall be less than or equal to 120 inches per Section 084]: xx.x ft | |
| 070-1 | Enter Height, Keel to Fixed Structure: xx.x ft | |
| 070-1 | Enter Height, Keel to Moveable Structure: xx.x ft | |
| 070-1 | Enter Height on trailer when rigged for transport [Shall be less than or equal to 162 inches per Section 084]: xx.x ft | |
| 070-1 | Enter Width on trailer when rigged for transport [Shall be less than or equal to 120 inches per Section 084]: xx.x ft | |
| 070-1 | Enter Height from waterline to fixed structure: xx.x ft | |
| 070-1 | Enter Deadrise at midships: xx degrees | |
| 070-1 | Enter Deadrise at transom: xx degrees | |
| 070-1 | Enter Total Installed Fuel Capacity: xxx gallons | |
| 070-1 | Enter Total Installed HPU Fuel Capacity: xxx gallons | |
| 070-1 | Enter Total Installed Oil Recover Tanks Capacity: xxx gallons | |
| 070-1 | Enter Full Load Weight: (as defined in Section 070): xx,xxx lbs incl x% construction or build margin or both | |
| 070-1 | Enter LCG in Full Load: xx.x ft forward of the transom/keel intersect | |
| 070-1 | Enter Skimming Speed [Shall be 1.5+ knots] xx knots at Full Load in calm water | |
| 070-1 | Enter Sprint Speed [Shall be 15+ knots] xx knots at Minimum Operation in calm water | |
| 084-3 | Enter Highway Trailer Make and Model; | |
| 100-1 | General Requirements for Hull Structure - Provide a name and short description of structural methodology. | |
| 236-2 | Outboard Engines - Honda Model and horsepower | |
| 236-2 | Outboard Engines - Mercury Model and horsepower | |
| 236-2 | Outboard Engines - Yamaha Model and horsepower | |
| 556-1 | Hydraulic Power Unit - Make and Model | |
| 593-1 | Oil Skimmer Module - Provide Description of System |
Offeror's Notes:
&12RFP N00024-16-R-22XX
Example Response
| ATTACHMENT 2 |
| SPECIFICATION RESPONSE MATRIX - EXAMPLE RESPONSE |
See below for partial example responses.
Specification Item Specification Parameter Offeror Response (See Note 1)
| 070-1 | Enter Length Overall (LOA): xx.xx ft | 31.50 ft |
| 070-1 | Enter Length with collar deflated: xx.xx ft | 30.75 ft |
| 070-1 | Enter Hull Length (Lhull): xx.xx ft | 29.50 ft |
| 070-1 | Enter Beam Overall (BOA): xx.x ft | 10.0 ft |
| 070-1 | Enter Deadrise: xx degrees (state if constant or variable) | 19 degrees, constant |
| 070-1 | Enter Total Installed Fuel Capacity: xxx gallons | 175 gallons |
| 070-1 | Enter Full Load Weight: OCC Variant (as defined in Section 070-4): x,xxx lbs incl x% construction margin | 12,000 lbs with 3% construction margin |
| 070-1 | Enter Cruise Speed (at xx,xxx engine RPM): xx knots at Full Load in calm water | 33 knots at 5,000 rpm |
| 070-2 | Enter list of submitted drawings describing the proposed boat. | 100-123456 Gen'l Arr MERC OCC |
100-123457 Transport MERC OCC (Continue per Sect L)
| 084-6 | Enter Trailer Make & Model; confirm trailer spec sheet submitted in Vol I. | Boatmaster Model 32-RTT; Spec Sheet in Vol I |
| 130-1 | Enter Aft Deck Interior Beam: xx inches | OJECTIVE MET |
85 inches
| 236-1 | Enter Projected Static Bollard Pull: x,xxx lbs using Government's perferred engine model. | 4,400 lbs |
| 310-1 | Enter Generator Make & Model | Kohler 7.5 EKD |
| 512-4CAB | Enter HVAC Make, Model, Quantity | (2) Dometic VTD8K |
| 512-4CAB | Enter HVAC cooling capacity: x,xxx BTU | 8,000 BTU (each) |
| Offeror's Notes: | ||
| 313-3: Exception: Builder has no local distributor for Blue Seas voltmeters. Builder proposes a BrandX Model xxx123 voltmeter in lieu of a Blue Seas voltmeter specified. A catalog sheet for BrandX Model xxx123 is included in Vol I. Builder has used BrandX voltmeters in 300 boats in similar applications. |