Att_2_FY16_EOD_MERC_Specification_Response_extra_variant.xlsx
XLSX spreadsheet 22 KB Posted
- Solicitation number
- N0002416R2215
About this file
Attachment 2 FY16 EOD MERC Specification Response
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Att 1 Spec Response Matrix
| ATTACHMENT 2 |
| SPECIFICATION RESPONSE MATRIX |
NOTES & INSTRUCTIONS:
Offerors to submit Attachment 2 with response for parameters identified in the Specification (See Section J).
1. Where specific parameters or other technical information are required in the Specification (indicated by red text in the Specification), Offerors shall fill in the specific parameters/information for their proposed design for each boat configuration (as applicable) in this attachment and include supporting data in Vol I as directed. At bottom Offerors shall respond with 'Comply' to indicate their design meets all Specification requirements; or 'Comply w/Exceptions' to indicate disagreement with any specific section of the Specification.
2. A response of 'Comply w/Exceptions' shall be accompanied by amplifying notes in the 'Offeror's Notes' section at bottom, providing rationale for any exceptions. Each exception shall list the Specification section, the specific rationale for non-compliance with the section, and a proposed alternative approach. Any proposed alternative approach must meet the minimum requirement of the Specification to the Government's satisfaction. Description of Offeror's alternative approach shall include the detailed approach to achieving the minimum Specification requirement; applicable material specifications, make and model numbers for all parts/components; compliance with any requisite commercial or military standard, or associated “best practice”; and shall include any supporting product performance, test data, or other empirical evidence for the proposed product or service capability where applicable. The Government reserves the right to reject (without discussion) any proposed alternative which is incomplete or fails to meet minimum requirements of the Specification.
3. A response is required for each Specification section identified herein. The Government reserves the right to evaluate incomplete responses as non-compliant with the Specification and unacceptable for Factor 1 (Technical Approach).
Specification Item Specification Parameter Offeror Response (See Note 1)
| 070-1 | Enter Length Overall (LOA): xx.xx ft |
| 070-1 | Enter Length with collar deflated: xx.xx ft |
| 070-1 | Enter Hull Length (Lhull): xx.xx ft |
| 070-1 | Enter Beam Overall (BOA): xx.x ft |
| 070-1 | Enter Beam with collar deflated: xx.x ft |
| 070-1 | Enter Chine Beam: xx.x ft |
| 070-1 | Enter Height, Keel to Fixed Structure: xx.x ft |
| 070-1 | Enter Height, Keel to Moveable Structure: xx.x ft |
| 070-1 | Enter Length on trailer when rigged for transport: xx.x ft |
| 070-1 | Enter Height on trailer when rigged for transport: xx.x ft |
| 070-1 | Enter Width on trailer when rigged for transport: xx.x ft |
| 070-1 | Enter Deadrise: xx degrees (state if constant or variable) |
| 070-1 | Enter Total Installed Fuel Capacity: xxx gallons |
| 070-1 | Enter Full Load Weight: OCC Variant (as defined in Section 070-4): xx,xxx lbs incl x% construction margin |
| 070-1 | Enter Full Load Weight: Cabin Variant (as defined in Section 070-4): xx,xxx lbs incl x% construction margin |
| 070-1 | Enter LCG in Full Load: OCC Variant: xx.x ft forward of the transom/keel intersect |
| 070-1 | Enter LCG in Full Load: Cabin Variant: xx.x ft forward of the transom/keel intersect |
| 070-1 | Enter Draft: x.x ft at Full Load |
| 070-1 | Enter Cruise Speed (at x,xxx engine RPM): xx knots at Full Load in calm water |
| 070-1 | Enter Sprint Speed (at wide open throttle): xx knots at Full Load in calm water |
| 070-2 | Enter list of submitted drawings describing the proposed OCC boat. |
| 070-2 | Enter list of submitted drawings describing the proposed Cabin boat. |
| 084-2 | State if OBJECTIVE requirement is met with proposed design. |
Enter GVW: xx,xxx lbs
| 084-6OCC/CAB | Enter Trailer Make & Model; confirm trailer spec sheet submitted in Vol I. |
| 084-6NOM | Enter Trailer Make & Model; confirm trailer spec sheet submitted in Vol I. |
| 130-1 | State if OBJECTIVE requirement is met with proposed design. |
Enter Aft Deck Interior Beam: xx.x ft
| 130-2 | Enter Aft Deck Clear Interior Length: xx.x ft |
| 236-1OCC/CAB | Enter Projected Cruise Speed: xx knots using Government's perferred engine model. |
| 236-1OCC/CAB | Enter Projected Sprint Speed: xx knots using Government's perferred engine model. |
| 236-1OCC/CAB | Enter Projected Static Bollard Pull: x,xxx lbs using Government's perferred engine model. |
| 236-1NOM | Enter Projected Cruise Speed: xx knots using Government's perferred engine model. |
| 236-1NOM | Enter Projected Sprint Speed: xx knots using Government's perferred engine model. |
| 310-1OCC/CAB | Enter Generator Make & Model |
| 512-4CAB | Enter HVAC Make & Model |
| 512-4CAB | Enter HVAC cooling capacity: x,xxx BTU |
| 512-4CAB | Enter HVAC heating capacity: x,xxx watts |
| 529-2 | Electric Bilge Pump - Enter specific bilge pump quantity and locations. |
| 541-1 | Enter Fuel Tank Size: xxx gallons |
| Offeror's Notes: |
&12RFP N00024-16-R-2215
Example Response
| ATTACHMENT 2 |
| SPECIFICATION RESPONSE MATRIX - EXAMPLE RESPONSE |
See below for partial example responses.
Specification Item Specification Parameter Offeror Response (See Note 1)
| 070-1 | Enter Length Overall (LOA): xx.xx ft | 31.50 ft |
| 070-1 | Enter Length with collar deflated: xx.xx ft | 30.75 ft |
| 070-1 | Enter Hull Length (Lhull): xx.xx ft | 29.50 ft |
| 070-1 | Enter Beam Overall (BOA): xx.x ft | 10.0 ft |
| 070-1 | Enter Deadrise: xx degrees (state if constant or variable) | 19 degrees, constant |
| 070-1 | Enter Total Installed Fuel Capacity: xxx gallons | 175 gallons |
| 070-1 | Enter Full Load Weight: OCC Variant (as defined in Section 070-4): x,xxx lbs incl x% construction margin | 12,000 lbs with 3% construction margin |
| 070-1 | Enter Cruise Speed (at xx,xxx engine RPM): xx knots at Full Load in calm water | 33 knots at 5,000 rpm |
| 070-2 | Enter list of submitted drawings describing the proposed boat. | 100-123456 Gen'l Arr MERC OCC |
100-123457 Transport MERC OCC (Continue per Sect L)
| 084-6 | Enter Trailer Make & Model; confirm trailer spec sheet submitted in Vol I. | Boatmaster Model 32-RTT; Spec Sheet in Vol I |
| 130-1 | Enter Aft Deck Interior Beam: xx inches | OJECTIVE MET |
85 inches
| 236-1 | Enter Projected Static Bollard Pull: x,xxx lbs using Government's perferred engine model. | 4,400 lbs |
| 310-1 | Enter Generator Make & Model | Kohler 7.5 EKD |
| 512-4CAB | Enter HVAC Make, Model, Quantity | (2) Dometic VTD8K |
| 512-4CAB | Enter HVAC cooling capacity: x,xxx BTU | 8,000 BTU (each) |
| Offeror's Notes: | ||
| 313-3: Exception: Builder has no local distributor for Blue Seas voltmeters. Builder proposes a BrandX Model xxx123 voltmeter in lieu of a Blue Seas voltmeter specified. A catalog sheet for BrandX Model xxx123 is included in Vol I. Builder has used BrandX voltmeters in 300 boats in similar applications. |
File details come from the government source that posted it. Updated .