This Request for Proposal is issued by Geosyntec Consultants, Inc. on behalf of the Escambia County Waste Services Department for monitoring well installation services at the Klondike Landfill, a closed landfill facility located at 7219 Mobile Highway, Pensacola, Escambia County, Florida (FDEP Facility ID No. 1690, FDEP Permit No. 0078440-007-SO). The project requires installation of three two-inch monitoring wells by a Florida-licensed drilling contractor. Specific well locations and depths include PIW-2R at 50 feet below ground surface, PIW-3R at 25 feet below ground surface, and DW-2IR at 70 feet below ground surface. Premobilization activities include obtaining drilling and well installation permits from the Northwest Florida Water Management District and notifying 811/One-Call for utility location services. The scope of work encompasses three continuous 6-inch diameter borings with continuous sampling from 50 to 70 feet below ground surface, installation of monitoring wells with specified sand filter pack and bentonite seal materials, neat cement grout placement through tremie pipe, and completion with 4-inch lockable aluminum cover stick-up covers and 3-foot by 3-foot concrete pads 6 inches thick with etched well labels.
The RFP does not specify pricing terms, contract award dates, contract term duration, or renewal options. No set-asides, incumbent information, or funding amounts are identified in the proposal document. Interested contractors should contact Kyle Carlton, P.G. (FL), Senior Geologist, at 850-483-5112 for clarification on proposal requirements and project details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Klondike_Landfill_Monitoring_Well_Installation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1120 N 12th Avenue Pensacola, FL 32501 www.geosyntec.com
Request for Proposal for Monitoring Well Replacement – Klondike Landfill
10 August 2026
To: Licensed Florida Drilling Contractor
From: Escambia County Waste Services Department Geosyntec Consultants, Inc.
Subject: Request for Proposal: Monitoring Well Installation Klondike Landfill 7219 Mobile Highway Pensacola, Escambia County, Florida FDEP Facility ID No. 1690 FDEP Permit No. 0078440-007-SO
Dear Drilling Subcontractor, Geosyntec Consultants, Inc. (Geosyntec) and the Escambia County Waste Services Department (ECWS) requests a proposal for the installation of three monitoring wells at the Klondike Landfill (closed) located at 7219 Mobile Highway, Pensacola, Escambia County, Florida.
Scope of Work
Premobilization activities:
- The licensed Florida driller will request drilling and well installation permits from the Northwest Florida Water Management District.
- The licensed Florida driller will notify the 811 / One-Call to request utility location from the local utility companies.
Monitoring Well Installation:
- Three (3) continuous borings (4x6 sonic) and sampling from 50 ft bgs to 70 ft bgs (max 70’). Boring diameter will be 6-inches.
- Install two-inch monitoring wells into each of the three borings.
10 August 2026
Request for Proposal for Monitoring Well Replacements – Klondike Landfill
- Install sand filter pack of 20/40 silica sand to 2-ft above screen. 1-ft fine 30/65 sand seal (~1’ thick) should separate the filter pack from the bentonite pellets. 2 feet to 3 feet of bentonite pellets.
- Neat cement grout shall be mixed using 6 gallons of water per 94 pound bag of Type I/II Portland cement to a density of 15 lbs/gal and introduced to the annular space through a tremie pipe installed just above the well seal material and placed progressively upwards to ground surface.
- Complete monitoring wells with 4-inch lockable aluminum cover stick up cover, a 3 ft by 3 ft formed concrete pad, 6-inch thick.
- Include and attach etched well labels.
Proposed monitoring well details:
PIW-2R
Depth: 50 ft bgs Latitude: 30.489277 Longitude: -87.338994
PIW-3R
Depth: 25 ft bgs Latitude: 30.481855 Longitude: -87.341953
DW-2IR
Depth: 70 ft bgs: Latitude: 30.489386 Longitude: -87.338963
Please contact Kyle Carlton at 850.483.5112 if you have any questions.
Sincerely, Kyle J. Carlton, P.G. (FL) Senior Geologist