About this file

This document contains the technical specifications for a connected, boilerless steam cooker made by AccuTemp Products, Inc. The product, called the N6/P6 DBL CONNECTED EVOLUTION, is a double-stacked, 6-pan, natural gas or propane-powered convection steamer. It features patent-pending Steam Vector Technology, digital controls, automatic altitude compensation, and other advanced features. The unit is designed to meet NSF/ANSI 4 safety and sanitation standards.

The related state and local contract opportunity is an RFP (RFP 260-04042024-481015) issued by Forsyth County and the City of Winston-Salem in North Carolina to procure kitchen equipment. The RFP provides a detailed Scope of Work for the required equipment and services. No additional details are provided regarding response dates, award information, contract term, or pricing requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Standard Features

• Fast cook times with patent-pending Steam Vector Technology, which utilizes no moving parts

• Cook mode and Variable Temperature Hold mode

• Steamer powered by a Heavy Duty Stainless Steel Blue Flame Power Burner rated at 60,000 btu/hr

• Easy-to-use digital controls, with digital temperature display

• Independent digital electronic timer with programmable preset

• Simple water and drain connections

• No water filtration or treatment required

• No warranty exclusions for water quality

• Uses less than 1 gallon of water per hour

• Front-mounted drain valve

• Specify Altitude if over 2,000 ft above sea level

• Internal gas regulator

• No scheduled de-liming or maintenance

• Heavy-duty, field-reversible door

• Door can be opened at any time during cooking cycle

• Steamer cavity constructed of reinforced

14 ga. 304 stainless steel

• Easy-to-clean control panel

• Automatic altitude compensation

• Dishwasher-safe one-piece wire pan racks

• Dishwasher-safe SVT steam collector and distributor panels

• Front-mounted condensate tray

• English and Spanish operating instructions on door

• Simplified service access panel

• Low water, high water and overtemp indicator lights

• Recommended that

• (2) 5’ power cords and plugs included, separate receptacle needed for each unit

• One year parts and labor warranty

• Lifetime Service & Support Guarantee

• UL LISTED Safety Certification

(ANSI Z 83.11)

• UL EPH Sanitation Certification

(NSF 4)

Optional Features

• Stainless steel, ergo-low support stand available with casters, bullet feet or flanged feet

• Propane

Safety, Sanitation & Environmental

Pan Capacities - per cavity

Pan Size Qty.

#200 full size (12x20x2.5”) 6 #400 full size (12x20x4”) 4

Short Spec

Evolution™ steamer is AccuTemp Products’ connected, boilerless steam cooker that utilizes AccuTemp’s Patent Pending Steam Vector Technology for faster cook times, improved energy efficiency, better pan to pan uniformity, and less water consumption. Steam Vector Technology requires no moving parts inside the cooking chamber. Steam to be produced inside the cooking cavity with no heating components exposed to water. Unit to be powered by a Heavy Duty Stainless Steel Blue Flame Power burner, Easily connects to water, drain & gas lines. Uses less than 1 gallon of water per hour. Unit to include low water, high water, overtemp warning lights and auto shut off feature.

Evolution™ to include heavy duty, field reversible door. Standard digital controls with independent timer. No water quality exclusions to warranty and no water filtration or treatment required. Units to be mounted on a stainless steel support stand.

Unit to be UL Safety and Sanitation Certified, and Energy Star qualified. Built in USA.

MM4228-2001

Project: ___________________________________ Location: ___________________________________ Item #: ___________________________________ Quantity:___________

AccuTemp Products, Inc.

8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net

N6 Evolution™ double stacked connected unit mounted on a stainless steel stand with casters

N6/P6 DBL CONNECTED EVOLUTION ™

2 Double Stacked. Stand-Mounted 6 Pan, Natural Gas or Propane Boilerless Convection Steamers

NSF/ANSI 4

® EVOLUTION

BOILER-FREE STEAMER

AccuTemp product may be covered by one or more US Patents. See www.accutempip.net

Gas Steamer Model Specifications per cavity

DBL = TWO CAVITIES

Model # N61201E DBL P61201E DBL

Gas Supply Natural Gas Propane

Recommended Gas Feed Rate

5” wc min 14” wc max

12” wc min 14” wc max

Gas operating Pressure

5.0” wc 10.0” wc

Maximum input BTU’s/hr

60,000 60,000

Electrical Powered 120v, Single Phase, 60hz, 1 AMP

NEMA Plug 5-15 three prong plug

Notes:

1. Allow 3” between fryer, ranges, and other hot surfaces.

2. Each unit equipped with 5’ power cord with NEMA 5-15 three prong plug, 120v, single phase, 60hz, 1 AMP.

3. For use on individual branch circuits only.

4. Each unit equipped with 1/2” NPT Threaded Natural Gas or Propane Connection.

5. Dimensions outside brackets are inches, in brackets are millimeters.

6. Each unit equipped with 3/4” male garden hose connector

7. Each unit equipped with 3/4” barbed drain line connector

8. DO NOT plumb a single drain line between the 2 units. Each unit must have a separate open gap type drain line.

9. This appliance not intended for household use.

10. Units equipped with internal Gas Regulator.

MM4228-2001AccuTemp Products, Inc.

8415 North Clinton Park • Fort Wayne, IN 46825 • 800-210-5907 • 260-493-0415 • Fax 260-493-0318 • accutemp.net

15.43 391.8

43.33 1100.7

N6/P6 DBL CONNECTED EVOLUTION ™

2 Double Stacked. Stand-Mounted 6 Pan, Natural Gas or Propane Boilerless Convection Steamers

Unless otherwise specified, Dimensions: Inches Bends: 90 Tolerances:

Angular 1° 2 Place Decimal .02 3 Place Decimal .005 T.I.R .005 √125 Micro Inches GD&T Per ANSI Y14.5M

INDICATED EDGES

MUST BE SOFTENED:

* = NEAR SIDE

* = FAR SIDE

* = BOTH SIDES

39.37

26.63

676.40

9.30

236.09

34.83

884.56

64.90

1648.46

1.71

43.31

23.26

590.88

AT1T-5099-11

DOUBLE UNIT STAND & 6 PAN CONNECTED GAS EVOLUTION

1/2 NPT GAS CONNECTION

3/4 IN. MGH WATER CONNECTION

AC POWER CORD

3/4 IN. BARB

FOR OPEN-GAP DRAIN

7.45

189.18

14.41

365.89

16.11

409.19

16.35

415.16

37.53

953.26

44.48

1129.79

46.19

1173.10

46.42

1179.07

3.74

94.89

5.92

150.42

6.70

170.23

6.03

153.04

2.79

70.95

1.47

37.34

23.63

600.20

28.94

735.11

ECN: NOT RELEASED!Scale: 1:24 Sheet 11 of 11

B

Title:

Rev.Drawing No.:Size:

AT1T-5099 -01

AccuTemp Products, Inc.

8415 N. Clinton Park

Fort Wayne, IN 46825

Name Date

4/12/2017Drawn

Checked DWT

DWTProj. Engr.

Do Not Scale Drawing N/A

Finish:

Material:

Comments:

4/12/2017

N/A

4/12/2017

ATP

L A

S T

S A

V E

D : a p a y n e F rid a y , A p ril 1

, 2

:1

:4

A

M

OUTLINE DWG, STEAMER &

STAND

® EVOLUTION

BOILER-FREE STEAMER

AccuTemp product may be covered by one or more US Patents. See www.accutempip.net