Minimum Technical Requirements.pdf
PDF 219 KB Posted
- Attached to
- Blanket Purchase Agreement (BPA) for twenty-two (22) superglue fuming chamber with UV contamination
- Solicitation number
- DJA-26-ALAB-PR-0222
About this file
This is a Minimum Technical Requirements document for a federal procurement of twenty-two (22) superglue fuming chambers with UV contamination modules. The vendor must provide brand new equipment certified to Foster & Freeman Original Equipment Manufacturer (OEM) specifications. Each fuming chamber must have approximately 28 cubic feet of internal volume (50 inches H x 31.6 inches W x 31.4 inches D) with digital variable controls for temperature, humidity, fuming and purge cycle times. Required features include adjustable humidity controls from 75%-90%, dual temperature hot plates with minimum 120°C capability (230°C desirable but not required), internal air circulation with fan assistance, integrated user-serviceable CA fume containment filtration, and UV-C (254nm output) decontamination modules. Each unit must include a storage tube for the UV module, integrated hanging hook, and self-capping connectors. Equipment shall be constructed of powder coat, aluminum, or stainless steel with glass windows or door apertures and mounted on wheels for mobility.
Each procurement includes forty-four (44) carbon filters (two per unit), variable shelf locations, and twenty-two (2) stainless steel user-configurable racking/shelving units with hanging rails featuring four large shelves, one corner unit, one corner unit with integrated support, and all necessary poles. Equipment must be tested and certified compliant with current occupational exposure standards (<.03ppm). Delivery shall occur within approximately thirty (30) days of contract receipt to one of three locations: Forensic Crime Gun Intelligence Laboratory (FCGIL), Bureau of Alcohol, Tobacco, Firearms and Explosives in Wichita, Kansas; FSL-A in Atlanta, Georgia; or FSL-W in Beltsville, Maryland. The first order includes manufacturer training and installation at the FCGIL location, with subsequent deliveries installed by the laboratory. Shipping, handling, and one product training session upon first delivery are included in the contract.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fuming chamber with UV contamination module Minimum Technical Requirements
Summary
This procurement is for twenty-two (22) superglue fuming chamber with UV contamination. The vendor must meet the minimum Technical Requirements listed below which must be brand new and be certified to the manufacturer’s Original Equipment Manufacturer (OEM) specification.
OEM is Foster & Freeman :
Fuming chamber capabilities:
• Up to twenty-two (22) FFLEX fuming chambers (MVC/FFLEX)
• Approximately 28 cubic feet internal volume (approximate Internal dimensions: 50 inches H x 31.6 inches W x 31.4 inches D)
• Digital variable control for temperature, humidity, fuming and purge cycle times
• Customizable saved processes and logs usage
• Automatic purge
• Adjustable humidity controls from 75%-90% minimum
• Dual temperature hot plate with a minimum 120⁰ C temperature (230⁰ C capability desirable for micro-bursting but not required)
• Internal air circulation with fan assistance
• Integrated filtration system for CA fume containment, user serviceable (no external ducting to facility)
• UV-C (254nm output) decontamination module (MVC/FFLEX/UVKIT) o Includes storage for tube o Integrated hanging hook o Self-capping connectors
• Two (2) per unit equals forty-four (44) Carbon filters should be included
• Variable shelf locations and various positions to suspend items
• Cabinet on wheels
• 120 V power
• Powder coat, aluminum or stainless-steel construction
• Glass windows or door aperture
• Floor standing or with elevated stand or cart for ease of loading and unloading
• Twenty-two (2) Stainless steel user configurable racking/shelving with hanging rails
(MVC/FFLEX/M/EXTENDED)
o With four (4) large shelves o One (1) corner unit o One (1) corner unit with integrated support o Includes all poles for shelving
• Must be tested and certified compliant with current occupational Exposure Standards (<.03ppm)
• Shipping and handling included
• Includes one (1) product training upon first delivery
FSL-A Dual Wavelength Forensic Laser and Imaging System Minimum Technical Requirements
Delivery Locations and Schedule:
• The equipment shall be delivered within approximately thirty (30) days of receipt of the contract.
• The first call-order will include training and installation by manufacturer to the FCGIL location below. All other equipment shall be installed by the laboratory.
• Twenty-two (22) superglue fuming chambers with UV contamination module, shelving and filters will be delivered to any of the following locations to be determined at the time of order:
o Forensic Crime Gun Intelligence Laboratory (FCGIL) Bureau of Alcohol, Tobacco, Firearms and Explosives, 4504 E 18th ST N, Wichita, KS 67208 o FSL-A, 2600 Century Parkway NE, Suite 400, Atlanta, GA 30345 o FSL-W 6000 Ammendale BLVD, Beltsville MD 20705