This document is a Request for Quotations (RFQ) for providing cabling for TS-405 Controls and Instrumentation at the NASA White Sands Test Facility. The solicitation is a Total Small Business Set-aside with a NAICS code of 423610 - Electrical Apparatus and Equipment and a size standard of 200 employees.

The RFQ requires the following quantities of Teflon-insulated, shielded cables in 1000 ft spools: 48 spools of 20AWG 6-conductor, 27 spools of 22AWG 6-conductor, and 8 spools of 12AWG 2-conductor. Offers are due by 2:00 PM MT on April 9, 2024 and must include pricing, delivery schedule, and other commercial terms. The Government will award a contract to the responsible offeror whose offer is most advantageous based on technical capability and price. Delivery is required within 12 weeks of order receipt, FOB Destination to the NASA White Sands Test Facility in New Mexico.

View the file

Other files for this federal contract opportunity

Other files attached to Cabling for TS-405 Controls and Instrumentation, newest first.
File Type Posted
TC122F.pdf PDF
TC206F.pdf PDF
Terms and Conditions.pdf PDF
TC226F.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

30 Toll Free: (800) 423-5873 International: +1 (661) 295-3100www.thermaxconnects.com

MIL-W-16878/11 (Type K) equivalent wire—extruded FEP insulation

MIL-W-16878/11 (type K) equivalent wires have extruded FEP insulation (medium wall thickness) for high-temperature applications. These wires have tin-plated copper conductors for economy. MIL-spec versions (silver-plated conductors) are also available.

For heavy-wall (type KK) versions of these wires, see M16878/12 equivalent (following page); for thin-wall (type KT) versions, see M16878/13 equivalent (page 32).

Performance:

Voltage rating: 600V.

Temperature rating: Tin-plated conductor: -55 to 150˚ C;

Silver-plated conductor: -55 to 200˚ C;

Nickel-plated conductor: -55 to 200˚ C.

Construction Details Insulation: Extruded FEP, wall thickness .010 (.25 mm).

Conductor: Tin-plated copper.

Colors: Color coded to MIL-STD-104 (See page 26).

Options: Silver- or nickel-plated copper conductor;

silver or nickel-plated high-strength copper alloy conductor; sodium napthalene etched insulation for bondability. Also available to NEMA HP-4-K.

AWG Size Stranding Conductor Insulation Diameter

Weight Maximum Thermax

Diameter Minimum Maximum Resistance P/N

8 133/29 .162 (4.11) .185 (4.70) .199 (5.05) 63.6 (9.46) .658 (2.16) 8-DXZ-13329

10 37/26 .108 (2.74) .127 (3.23) .141 (3.58) 33.1 (4.93) 1.26 (4.13) 10-DXZ-3726

12 19/25 .084 (2.13) .107 (2.72) .121 (3.07) 23.7 (3.53) 1.92 (6.30) 12-DXZ-1925

14 19/27 .067 (1.70) .088 (2.24) .102 (2.59) 15.5 (2.31) 3.06 (10.0) 14-DXZ-1927

16 19/29 .053 (1.35) .073 (1.85) .087 (2.21) 10.1 (1.50) 4.81 (15.8) 16-DXZ-1929

18 19/30 .047 (1.19) .064 (1.63) .074 (1.88) 7.74 (1.15) 6.23 (20.4) 18-DXZ-1930

18 7/26 .048 (1.22) .064 (1.63) .074 (1.88) 7.70 (1.15) 6.70 (22.0) 18-DXZ-726

20 19/32 .038 (.97) .054 (1.37) .062 (1.57) 5.08 (.756) 9.88 (32.4) 20-DXZ-1932

20 7/28 .038 (.97) .054 (1.37) .062 (1.57) 5.97 (.740) 10.7 (35.1) 20-DXZ-728

20 SOLID .032 (.81) .048 (1.22) .056 (1.42) 4.18 (.622) 10.9 (35.1) 20-DXZ-120

22 19/34 .030 (.76) .046 (1.17) .054 (1.37) 3.42 (.509) 16.2 (53.1) 22-DXZ-1934

22 7/30 .030 (.76) .046 (1.17) .054 (1.37) 3.33 (.496) 17.1 (56.1) 22-DXZ-730

22 SOLID .025 (.64) .041 (1.04) .050 (1.27) 2.92 (.435) 17.7 (58.1) 22-DXZ-122

24 19/36 .024 (.61) .040 (1.02) .048 (1.22) 2.39 (.356) 26.2 (85.9) 24-DXZ-1936

24 7/32 .024 (.61) .040 (1.02) .048 (1.22) 2.35 (.350) 27.0 (88.6) 24-DXZ-732

24 SOLID .020 (.51) .036 (.91) .044 (1.12) 2.12 (.315) 27.8 (91.2) 24-DXZ-124

26 19/38 .019 (.48) .035 (.89) .043 (1.09) 1.70 (.253) 41.3 (135) 26-DXZ-1938

26 7/34 .019 (.48) .035 (.89) .043 (1.09) 1.66 (.247) 43.3 (142) 26-DXZ-734

26 SOLID .016 (.41) .032 (.81) .040 (1.02) 1.55 (.231) 45.3 (149) 26-DXZ-126

28 7/36 .015 (.38) .031 (.79) .039 (.99) 1.22 (.182) 68.6 (225) 28-DXZ-736

28 SOLID .013 (.33) .029 (.74) .037 (.94) 1.17 (.174) 71.6 (235) 28-DXZ-128

30 7/38 .012 (.31) .028 (.71) .036 (.91) .930 (.138) 114 (374) 30-DXZ-738

30 SOLID .010 (.25) .026 (.66) .034 (.86) .900 (.134) 116 (380) 30-DXZ-130

32 7/40 .009 (.23) .026 (.66) .034 (.86) .700 (.104) 189 (620) 32-DXZ-740

32 SOLID .008 (.20) .024 (.61) .032 (.81) .730 (.109) 178 (584) 32-DXZ-132

Dimensions, Resistance, and Weights—M16878/11 equivalent—tin plated conductor

Dimensions in inches (mm). Weights in pounds/1000 feet (Kg/1000 m). Resistance in Ω/1,000 feet (Ω/Km), @20˚ C.

All values are nominal unless otherwise indicated.

Ordering Information: Specify Thermax part number and color.

To order with optional conductor materials:

For silver-plated copper conductor, change DXZ in Thermax part number to DX.

For silver-plated high-strength copper conductor, change DXZ in Thermax part number to DXTF.

For nickel-plated copper conductor, change DXZ in Thermax part number to DXN.

For nickel-plated high-strength copper conductor, change DXZ in Thermax part number to DXTFN.

K060714-5_GUTS_090712_K060714-5 all pages.qxd 9/7/12 3:39 PM Page 30