Metal Detector specs.doc
DOC document 172 KB Posted
- Attached to
- 2x High end units 4x Standard units
- Solicitation number
- RFQ - 40A - 10040800000000000951
- Issued by
- Kennebec County, Maine
About this file
This is a technical specifications document for walk-through metal detectors required for a Maine state and local contract opportunity involving the procurement of 2 high-end units and 4 standard units. The metal detectors must conform to applicable EU directives and meet requirements including EN 60950 (electrical safety), EN 50081-1 (emission), EN 50082-1 (immunity), NILECJ-0601 security levels 1-5, and FAA approval standards. The units must be safe for wearers of heart pacemakers, pregnant women, and magnetic recording materials.
The specified metal detectors must operate in ambient temperatures ranging from -10°C to +55°C with humidity tolerance up to 95% without condensation and IP 20 protection rating. Power supply options include AC power (90-264VAC/45-65Hz) with 45W consumption and a T1A 5x20mm fuse, or battery power (24-35V DC). Key operational features include audible and visible alarms with alphanumeric and zone displays, relay contacts for remote alarm (SPDT), 100 sensitivity steps per program, individually adjustable zone sensitivity (0-255%), automatic or manual calibration, adjustable reset time, digital filtering for interference suppression, and user-friendly diagnostics. The units include a two-year warranty covering parts and labor and are compatible with remote security monitoring systems via RS422 and Ethernet connections.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Conditions and Instructions to Bidders.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Standard type.
CONFORMITY walk-through metal detectors conform to the applicable EU directives and meet the requirements of the following standards:
Safety Standards EN 60950 (Electrical safety) EMC Standards EN 50081-1 (Emission), EN 50082-1 (Immunity) Other Standards NILECJ-0601, security levels 1-5 (covers the design and performance of walk-through metal detectors), FAA approved. Safe for wearers of heart pacemakers, pregnant women and magnetic recording materials. Compliant Yes
SPECIFICATIONS
Ambient Operating Temperature From -10 °C to +55 °C (From +14 °F to +131 °F ) Humidity Up to 95%, no condensation Protection
IP 20 (EN 60529)
Power Supply AC Power: 90-264VAC/45-65Hz Battery: 24-35V DC Consumption: 45W Fuse: T1A 5x20 mm Power Cord: included Automatic adjustment, without manual intervention, for power fluctuations over the voltage range of 90 to 264V AC.
Alarm Audible/visible alarm.
Alphanumeric display and Zone Display. Relay contact for remote alarm (SPDT) Sensitivity 100 sensitivity steps per program Zone Sensitivity Adjustment All eight zones are individually adjustable (0 to 255 %) with respect to the overall sensitivity level Calibration Automatic or manually set.
An automatic sensitivity function selects the appropriate sensitivity for a specific weapon or test object. This eliminates the time consuming trial and error method.
Reset Time Adjustable Interference Suppression Digital filtering by signal processor and user selectable frequency selection Advanced Self-Adjusting Diagnostics User-friendly diagnostics identify fault condition Warranty Two (2) years, parts and labor Network Connections Remote Security Monitoring System compatible (RS422 and Ethernet) Higher Technology
File details come from the government source that posted it. Updated .