MECH Floor plans for FDA.pdf
PDF 11 MB Posted
- Attached to
- H312--Fire Damper Inspections and Certification Federal contract opportunity
- Solicitation number
- 36C24826Q0309
About this file
This document is a comprehensive mechanical systems legend, abbreviations guide, and general notes sheet for the James A. Haley Veterans' Hospital New Bed Tower project in Tampa, Florida, along with associated mechanical floor plans for multiple levels (Level G through Penthouse). The project is being executed by a Design-Build Team with Turner Construction as the contractor and Page Southerland Page, Inc. as the designer, under U.S. Army Corps of Engineers oversight.
The mechanical documentation establishes standardized symbols, abbreviations, and installation requirements for HVAC systems throughout the facility. Key design specifications include ductwork sizing standards, VAV (Variable Air Volume) and FCU (Fan Coil Unit) terminal specifications, and requirements for fire dampers, smoke dampers, and isolation dampers in rated partitions. Design conditions indicate summer operation at 92.4°F DB/80.5°F WB outside air and 75-86°F DB/20-60% RH inside, with winter conditions at 38.4°F DB. The facility employs multiple AHUs (Air Handling Units), chilled water systems with primary and secondary pumps, hot water circulation systems, condenser water loops, cooling towers, and extensive ductwork distribution networks. General notes mandate isolation valves at all branch piping and equipment connections, manual air vents at high points, proper piping grades, accessible valve locations, fire-rated sleeve penetrations, and coordination with other trades. VAV boxes and FCU units must be zone-mounted with thermostats, and all grease exhaust ducts require 2% slope toward hoods with access doors spaced no more than 20 feet apart. The floor plans depict detailed mechanical equipment placement, ductwork routing, and terminal unit locations across the multi-story facility, with extensive keyed notes referencing specific duct sizes, damper locations, and equipment interdependencies across vertical zones.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Final PWS Fire damper inspection 2026 02.docx | DOCX document | |
| 36C24826Q0309 0001_1.docx | DOCX document | |
| Vendor Instructions for VA Webform 10091.docx | DOCX document | |
| 36C24826Q0309_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LC
XXX-1
M M
R
W
MM
S
FDx FDx
100100
G
BDD
BDD
~ ~MM
PHASE
PHWR
PH
PRIMARY HOT WATER RETURN
FLOW TRANSMITTER, FOOT, FEET
FOOT-POUND
ABBREVIATIONS
FT
FT LB
PREHEAT COIL
PARTS PER MILLION
PHC
PRS
PRV
PPM
PHWS
PRIMARY
PRESSURE
PRESSURE SWITCH
PRI
PRESS
PS
PSF
PLUMBINGPLBG
POUNDS PER SQUARE FOOT
PRIMARY HOT WATER SUPPLY
PRESSURE REDUCING STATION
PRESSURE REDUCING VALVE
PIPE SLEEVE
PIPE THREAD, PNEUMATIC TUBE
PSL
PSIG
PSIA
PTAC
PT
QUART
RELOCATED
QT
R
PTRV PRESSURE TEMPERATURE RELIEF VALVE
PACKAGED TERMINAL AIR CONDITIONER
POUNDS PER SQUARE INCH GAUGE
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCHPSI
FURNACE, FURNISH
FULL VOLTAGE NON-REVERSING
FACE VELOCITY
FINNED TUBE RADIATION
FREEZING POINT
GALLON
GENERATOR, GENERAL
GAUGE (INSTRUMENT), GAGE (THICKNESS)
GLOBE VALVE
GALVANIZED IRON PIPE
GALVANIZED IRONGI
GAL
GEN
GLV
GIP
GA
FVNR
FVEL
FURN
FTR
FP
GATE VALVE
GALLONS PER HOUR
GLYCOL SUPPLY
GLYCOL RETURN, GRAINS
HOSE BIBB
HOSE CONNECTOR
HEATING COIL, HOSE CABINET
GTD
GPH
HB
HCONN
HC
GTV
GS
GR
GALLONS PER DAYGPD
GREATEST TEMPERATURE DIFFERENCE
GENERAL NOTES
RADIATOR
REFRIGERATION, REFRIGERANT
RECEIVER
RAD
RAC
REFR
RD
RCVR
RETURN
REDUCER
REVOLUTIONS
REFRIGERANT
RELATIVE HUMIDITY
ROUGHNESS
REFERENCE
RET
REV
RED
RFGT
RH
RGH
REF
ROOM AIR CONDITIONER
REHEAT COIL
REHEAT VALVE
RHC
RHG
RHV
RPM
RSL
RPS
RLL
ROOF TOP UNIT
RELIEF VALVE
SATURATION
SUPPLY AIR
SECOND
RTU
RV
SAT
SA
S
REFRIGERANT HOT GAS
REFRIGERANT LIQUID LINE
REVOLUTIONS PER MINUTE
REFRIGERANT SUCTION LINE
REVOLUTIONS PER SECOND
MERCURY
HEIGHT
HEAT PUMP, HIGH PRESSURE, HORSEPOWER
HANGER
HEAT EXCHANGER
HOUR
HIGH PRESSURE STEAM
HIGH PRESSURE DRIP TRAP
HIGH PRESSURE BOILER
HG
HGT
HPS
HPC
HPDT
HPB
HP
HGR
HEX
HR
HUMIDISTAT
HOT WATER
HOSE VALVE
HIGH TEMPERATURE HOT WATER
HUMIDITY SENSOR HIGH LIMIT
HUMIDITY SENSOR
HOT WATER RETURN
HOT WATER PUMP
HOT WATER CIRCULATING PUMP
HOT WATER COIL
HOT WATER BOILER
HSTAT
HWR
HWP
HWCP
HWC
HWB
HW
HVAC
HV
HTHW
HSH
HS
HIGH PRESSURE CONDENSATE
HEATING, VENTILATING AND AIR CONDITIONING
SPECIFIC GRAVITY, STEAM GAUGE
SHAFT HORSEPOWER
SENSIBLE HEAT GAIN
SENSIBLE HEAT
SENSIBLE HEAT RATIO
SG
SHP
SHG
SH
SHR
SEALANT
SEA LEVEL
SLEEVE
SENSOR
SUMP PUMP
SHWS
SLNT
SL
SLV
SMP
SNSR
SHWR SECONDARY HOT WATER RETURN
SECONDARY HOT WATER SUPPLY
SHUT OFF VALVE
STATIC PRESSURE
SPECIFICATION
SUPPLY
SOV
SP
SPEC
SPH
SPL
SPLY
SQUARE
STAINLESS STEEL
STEAM GENERATOR
SQ
SSP
SST
STGEN
SPS
STATIC PRESSURE HIGH LIMIT
STATIC PRESSURE LOW LIMIT
STATIC PRESSURE SENSOR
STAINLESS STEEL PIPE
SOLV SOLENOID VALVE
HYDRANT
INSTRUMENT AIR
INPUT/OUTPUT
HERTZ (FREQUENCY)
INVERT
INSTRUMENT
INSIDE DIAMETER
INDICATED HORSEPOWER
INCHES WATER COLUMN
IA
ID
ICW
I/O
HZ
HYD
IHP
INV
INSTR
IN WC
INFRARED
KELVIN [DEGREES]
IRON PIPE THREADED
IRON PIPE SIZE, INCHES PER SECOND
KILOWATT
POUNDS
THOUSAND FOOT-POUNDS
LEAVING AIR TEMPERATURE
KILOWATT HOUR
THOUSAND POUNDS
IR
K
KIP
KIP FT
LB
LAT
KWh
KW
IPT
IPS
IRON PIPEIP
INDUSTRIAL CITY WATER (NON-POTABLE)
SF SAFETY FACTOR, SQUARE FEET
HOT WATER SUPPLYHWS
RETURN AIRRA
HEADHD
A
AAV
SINGLE LINE
DUCTWORK SYMBOLS
SINGLE LINE
VALVE SYMBOLS
DOUBLE LINE
ABS
AC
AP
ACHKV
AD
AF
ADP
AFF
AHU
ACU
W/D
W/D
DØ
W/DØ
ROUND DUCT. D = DIAMETER
AMB
ANSI
AMP
APD
APR
APPROX
ASU
ASV
ATC
ATM
ATV
AS
R
FLEXIBLE DUCT
DIRECTION OF AIRFLOW
ALT
DØ
COMBINATION BALANCING &
BALL VALVE
BUTTERFLY VALVE
DIAPHRAGM VALVE
CHECK VALVE
R
PLUG VALVE
SHUT-OFF VALVE
W/D
W/D
W/DØ
SINGLE LINEDOUBLE LINE
PIPE AND FITTING SYMBOLS
PIPE
WELDED JOINT
SCREWED JOINT
GROOVED END JOINT
(OR GENERIC SINGLE LINE)
STUB END OR FLANGE
FLANGED JOINT
MECHANICAL (BALL) JOINT
ADAPTER W/ FLANGE RING
GROOVED END
ADAPTER FLANGE
DOUBLE LINE
AV
AVG
B/B
B&S
AWG
BAL
BBD
BARO PR
BF
BFV
FLEXIBLE CONNECTION
BLDG
BFW
BFBP
BLR
BLW
BHP
BO
BOD
BLWDN
BS
BOS
BOP
= VERTICAL POSITION
= HORIZONTAL POSITION
OPPOSED BLADE DAMPER
(OBD)
GLOBE VALVE, SEALED STEM
GLOBE VALVE
CIRCUIT SETTER
MANUAL AIR VENT
BTU
BT WLD
BSTR
BW
BV
BTUH
°C
CA
C/C
C-C
BYP
CAP
CC
CB
CD
CF
CCW
CFS
CH
CHW
CHWP
CHWPP
CFM
CACU
BSP
ADAPTER
FLANGED COUPLING
UNION
BRAIDED FLEXIBLE COUPLING
TEE
TEE, BRANCH TOWARD VIEWER
TEE, BRANCH AWAY FROM VIEWER
REDUCER - ECCENTRIC
REDUCER - CONCENTRIC
VERTICAL RUN ON PLAN
READ LEFT TO RIGHT
4" CWS
H W
R C
W R
H W
S
LOWER PIPE
BOP 12'-6" AFF
2" HWS
2" HWR
4" CWR
READ TOP TO BOTTOM
2" IA
4" HA (F) *
2" DIR
2" DIS
BOP 13'-6" AFF
2" IW
C W
S
4" HA (F) *
UPPER PIPE
BOP 13'-6" AFF
2" DIR
2" DIS
2" IW
2" IA
D
IS
IW IA H
A
F
IA
IW
DIS
HA(F) *
HWS
HWR
CWR
D
IR
DIR
CWS
UPPER PIPE
AUV
TEMPERATURE CONTROL VALVE
CELSIUS [DEGREES]
AIR LINE
AUTOMATIC AIR VENT
AUTOMATIC CHECK VALVE
ACCESS PANEL
ACCESS DOOR, AREA DRAIN
AIR FILTER
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
AMBIENT
AIR PRESSURE DROP
AIR PRESSURE RETURN
AIR SEPARATOR
AIR SUPPLY VENT
ANGLE STOP VALVE
AUTOMATIC TEMPERATURE CONTROL
ATMOSPHERE
ATMOSPHERIC VENT
AUTOMATIC VENT
AIR VENT
AVERAGE
BELL & SPIGOT
BACK TO BACK
BALANCE
BOILER BLOWDOWN
ABSOLUTE
AIR CONDITIONING UNIT
ALTERNATING CURRENT, AIR CURTAIN
ALTITUDE
AMERICAN NATIONAL STANDARDS INSTITUTE
AMERICAN WIRE GAUGE
AMPERE
APPARATUS DEW POINT
APPROXIMATE
BAROMETRIC PRESSURE
BOTH FACES
BLOWOFF
CENTER TO CENTER
BLOW DOWN LINE
CAPACITY
COMPUTER AIR CONDITIONING UNIT
COMPRESSED AIR
COOLING COIL
BYPASS
BOTH WAYS
BALL VALVE
BRITISH THERMAL UNIT PER HOUR
BRITISH THERMAL UNIT
BUTT WELD
BOOSTER
BLACK STEEL PIPE
BOTH SIDES
BOTTOM OF STEEL
BOTTOM OF PIPE
BOTTOM OF DUCT
BELOW
BOILER
BUILDING
BRAKE HORSEPOWER, BOILER HORSEPOWER
BOILER FEED WATER
BOILER FEED BOOSTER PUMP
BUTTERFLY VALVE
CUBIC CENTIMETER
CONDENSATE DRAIN
CHEMICAL FEED
CUBIC FEET PER MINUTE
CUBIC FEET PER SECOND
CHILLER
CHILLED WATER
CHILLED WATER PUMP
CHILLED WATER PRIMARY PUMP
COUNTERCLOCKWISE
CATCH BASIN
STANDARD
STRAINER
STEAM
STC
STD
STR
STP
STM
SUCTION
SUPPLY
SAFETY VALVE
THROWAWAY
SUCT
SUP
SV
T
T&P
TA
SOUND TRANSMISSION CLASS
STANDARD TEMPERATURE & PRESSURE
TEMPERATURE SENSOR
TEMPERATURE AND PRESSURE [VALVE]
THERMOCOUPLE
TEMPERATURE, TEMPORARY
TCP
TCV
TC
TEMP
TD
TO FLOOR BELOW
THICK(NESS)
TUNNEL
TOP OF MANHOLE
TFB
THK
TMH
TNL
TR
TFA TO FLOOR ABOVE
TEMPERATURE CONTROL PANEL
TEMPERATURE CONTROL VALVE
TEMPERATURE DIFFERENCE
TONS OF REFRIGERATION
LINEAR FEET
LENGTH
LATENT HEAT GAIN
LATENT HEAT
LEAVING DRY BULB TEMPERATURE
LOW PRESSURE BOILER
LOW PRESSURE ALARM SWITCH
LOW PRESSURE
LF
LG
LMTD
LPC
LPB
LPAS
LP
LHG
LH
LDBT
LOUVER
LEAST TEMPERATURE DIFFERENCE
LOW TEMPERATURE HOT WATER
LOW PRESSURE STEAM
LOW PRESSURE DRIP TRAP SET
MAXIMUM
MANUAL AIR VENT
MAKE UP AIR UNIT
LEAVING WATER TEMPERATURE
LOW WATER CUT-OFF
LEAVING WET BULB TEMPERATURE
MAX
LTD
MAV
MAU
LWT
LWCO
LWBT
LVR
LTHW
LPS
LPDT
LEAST MEAN TEMPERATURE DIFFERENCE
LOW PRESSURE CONDENSATE
TRANSFER
TUBE STEEL
UNIT HEATER
THERMOSTAT
TRANS
TS
U
UH
TSTAT
VARIABLE
VENT, VOLTS
VAPOR PRESSURE
VELOCITY
VENT, VENTILATION
VAP PR
VAR
V
VAV
VEL
VENT
HEAT TRANSFER COEFFICIENT
VARIABLE AIR VOLUME
VISCOSITY
WATT
WET BULB
VELOCITY PRESSURE
VFD
VISC
W
WB
VP
WATER COLUMN
WATER CHILLER
WATER GAGE
WALL HUNG, WATT HOUR
WATER COOLED
WBT
WC
WCHR
WG
WH
WCLD
WET BULB TEMPERATURE
VARIABLE FREQUENCY DRIVE
VERTICALVERT
MINIMUM
MOTOR CONTROL CENTER
MINIMUM CIRCUIT AMPACITY
MEAN EFFECTIVE TEMPERATURE
MOTOR DIRECT CONNECT
THOUSAND CUBIC FEET
MILES PER HOUR
MEDIUM PRESSURE STEAM
MEDIUM PRESSURE
MOTOR OPERATED VALVE
MCC
MCA
MOCP
MPH
MPS
MPC
MP
MOV
MIN
MET
MDC
MCF
NOT APPLICABLE
MEAN TEMPERATURE DIFFERENCE
NOISE CRITERIA, NORMALLY CLOSED
MAKE-UP WATER
MEDIUM TEMPERATURE HOT WATER
NORMALLY OPEN, NUMBER
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NOT TO SCALE
NOT IN CONTRACT
NR
NRC
NTS
NO
NA
MTD
NIC
NC
MU
MTHW
MALE PIPE THREADMPT
MAXIMUM OVERCURRENT PROTECTION
MEDIUM PRESSURE CONDENSATE
TOP TOP OF PIPE
MIXING BOXMB
WELDED
WATER LINE
WATER METER
WATER PUMP
WL
WLD
WM
WPD
WPR
WSP
WP
YARD, YARD DRAIN
WEIGHT
YEAR
YD
WT
YR
WATER PRESSURE DROP
WORKING PRESSURE DROP
WORKING STEAM PRESSURE
Z ZONE
OUTSIDE AIR
OIL GAUGE
OIL LEVEL
OUTSIDE DIAMETER
OVERFLOW DRAIN
OUTSIDE AIR FAN
OIL SWITCH
OIL PRESSURE
OVERFLOW ROOF DRAIN
OPERATING STEAM PRESSURE
OD
OGA
OLVL
OPRS
ORD
OS
OSP
OFD
OA
OAF
PUMP
OUNCE
PERCENT
PIPE ANCHOR
PUMPED CONDENSATE
POSITIVE, PROVIDED BY OTHER SECTION
PRESSURE DROP, PRESSURE DIFFERENTIAL
PUMPED CONDENSATE DISCHARGE
PUMP DISCHARGE
PUMP SUCTION
PRECOOL COIL
P
PA
PC
PCC
PD
PCD
PDISCH
PMPSCT
POS
OZ
OVERFLOWOVFL
PRESSURE GAUGE
PUMPED RETURN
PRESSURE SWITCH
PG
PR
PRESS SW
PNEUMATIC ELECTRICPE
CHWR
CHWSP
CHWS
CKT
CIP
CKV
CI
CL
CMP
CLG
COMPR
COND
COEF
CNDS
CONDN
CONN
CPLG
CT
CU
CRP
CUH
CV
CU IN
CW
CWP
CWR
CU FT
DBT
DB
DDC
dB
DCW
DEG
DENS
DIA
DEWPT
DIFF
DDCFP
HUMIDIFIER
DIV
DPT
DR
DWV
DPS
EAT
ECC
ECON
EER
EFF
EDBT
ECU
DIP
CWS
CAP
ANCHOR
PIPE ALIGNMENT GUIDE
BLIND FLANGE
PG
TEST PORT
PIPING WITH INSULATION
(SLEEVED) PIPING
SECONDARY CONTAINMENT
EEEE
THERMOWELL
FLOW ORIFICE PLATE
EOV
ENT
EL
ESP
ET
EQIV
EWT
EWBT
EVAP
EXP
EXH
EXCH
FCU
FA
FD
F-F
FDW
FLG
FL SW
FLEX
FL
FPM
FLTR
°F
EXP JT
FRP
FSS
FSTAT
FPS
NOTES:
1. ONLY WELDED FITTINGS ARE SHOWN FOR DOUBLE LINE PIPING.
FITTINGS WITH OTHER END CONDITIONS ARE SIMILAR
DIVISION
EXPANSION JOINT
CENTER LINE ( )
CORRUGATED PIPE
CONDENSATE
COMPRESSOR
CONDENSER
CONDENSATION
CONNECTION
COUPLING
CONDENSATE RETURN PUMP
COOLING TOWER
COPPER
COEFFICIENT
COOLING
CABINET UNIT HEATER
CONDENSER WATER PUMP
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CLOCKWISE, CONDENSER WATER
CONSTANT-VOLUME [FLOW]
CUBIC FEET
CUBIC INCH
CIRCUIT
CAST IRON PIPE
CHILLED WATER RETURN
CAST IRON
CHILLED WATER SECONDARY PUMP
CHILLED WATER SUPPLY
CHECK VALVE
DRY BULB TEMPERATURE
DOMESTIC COLD WATER
DIRECT DIGITAL CONTROL
DIRECT DIGITAL CONTROL FIELD PANEL
DEGREES [CELSIUS OR FAHRENHEIT]
DUCTILE IRON PIPE
DIFFERENTIAL PRESSURE SENSOR
DIFFERENTIAL PRESSURE TRANSMITTER
DRAIN
DRAIN, WASTE & VENT
DENSITY
DEW POINT TEMPERATURE
DIFFERENCE OR
DIAMETER
DECIBEL
DRY BULB
ENTERING AIR TEMPERATURE
ECCENTRIC
ECONOMIZER
EVAPORATIVE COOLING UNIT
ENTERING DRY BULB TEMPERATURE
ENERGY EFFICIENCY RATIO
ELECTRONICALLY OPERATED VALVE
EXTERNAL STATIC PRESSURE
EXPANSION TANK, ENTERING TEMPERATURE
ENTERING WET BULB TEMPERATURE
ENTERING WATER TEMPERATURE
EXPANSION
EFFICIENCY
ENTERING
ELEVATION
EQUIVALENT
EVAPORATOR
EXCHANGER
EXHAUST
FAN COIL UNIT
FIRE DAMPER
FEEDWATER
FLOW SWITCH
FLEXIBLE CONNECTION
FLANGE
FLOW LINE ( )
FILTER
FEET PER MINUTE
FEET PER SECOND
FIBERGLASS REINFORCED PLASTIC
FLOW SENSING SWITCH
FREEZE STAT
FACE AREA, FREE AREA
FACE-to-FACE
FAHRENHEIT [DEGREES]
HORIZONTAL RUN ON PLAN
MULTI-LINE DESIGNATION KEY
4" CWR
LOWER PIPE
BOP 12'-6" AFF
4" CWS
2" HWS
2" HWR
CFCI CONTRACTOR FURNISHED/
WITH THERMOMETER
GENERIC PUMP
ELBOW, 90 DEGREE -
CHANGE IN DIRECTION
TOWARD VIEWER
ELBOW, 90 DEGREE -
CHANGE IN DIRECTION
AWAY FROM VIEWER
DUCT UNDER NEGATIVE PRESSURE,
SECTION TOWARD VIEWER
INSULATED PIPE WITH HEAT
TRACING TYPE AS NOTED
(E=ELECTRIC, S=STEAM,
HW=HOT WATER)
BFBF
LATERAL
PG
UON UNLESS OTHERWISE NOTED
FL
NOMINAL PIPE SIZENPS
OBD
VD
MANUAL VOLUME DAMPER,
(PARALLEL BLADE UON)
OBD
VD
BELLOWS-TYPE
FLEXIBLE COUPLING
GATE VALVE
(GENERIC VALVE SYMBOL)
2-WAY VALVE,
GLOBE STYLE
PNEUMATIC ACTUATOR,
MOTOR
NOTE:
VALVE TYPE GRAPHICS ARE SHOWN FOR SIZES 4 INCH NOMINAL
AND LARGER, MAY OR MAY NOT BE DESCRIBED ON VALVE SIZES
SMALLER THAN 4 INCH NOMINAL.
OFFSET (45° ELBOWS UON)
NON-SLAM (SPRING)
CHECK VALVE
PRESSURE GAUGE W/GAUGE COCK
(SERVICES EXCEPT STEAM)
PRESSURE GAUGE W/GAUGE COCK
AND SYPHON LOOP
(STEAM / CONDENSATE SERVICE)
AUTOMATIC AIR VENT
PRESSURE REDUCING VALVE
INDICATING LOW SIDE
PRESSURE
PRESSURE RELIEF/SAFETY VALVE
INDICATING RELIEF PRESSURE
THREE-WAY VALVE
(BALL TYPE BODY SHOWN)
STEAM TRAP, TYPE AS NOTED
IB = INVERTED BUCKET
F&T = FLOAT & THERMOSTATIC
TH = THERMODYNAMIC
BP = BALANCED PRESSURE
F&TF&T
BOTTOM OF STRUCTURAL STEELBSS
LEAVING TEMPERATURELT
AIR COOLED CONDENSING UNITACCU
PSID POUNDS PER SQUARE INCH DIFFERENTIAL
PSV PRESSURE SAFETY VALVE
PRV PRESSURE REGULATING VALVE
LOCKED ROTOR AMPSLRA
FULL LOAD AMPSFLA
GALLONS PER MINUTEGPM
INDIRECT WASTE, INDUSTRIAL WASTEIW
INVERT ELEVATIONIE
ABOVEABV
DIRECT CURRENTDC
VAC VOLTS ALTERNATING CURRENT
VOLTS DIRECT CURRENTVDC
MILLIAMPERESmA
Q TOTAL, TOTAL HEAT
MOTOR HORSEPOWERMHP
EXISTINGE
P/E PNEUMATIC ELECTRIC
OUTSIDE AIR INTAKEOAI
OFFSET, ROUND DUCT
(45° ELBOWS UON)
2-WAY VALVE,
GATE STYLE
2-WAY VALVE,
BUTTERFLY
STYLE
2-WAY VALVE,
BALL STYLE
ANGLE VALVE
PNEUMATIC ACTUATOR,
DIAPHRAGM
ELECTRIC ACTUATOR,
SOLENOID
ELECTRIC ACTUATOR,
MOTOR
AUTOMATIC VALVES
* - (F) INDICATES FUTURE PIPING ON RACK
AUTOMATIC ACTUATOR SYMBOLS
3-WAY VALVE,
GLOBE STYLE
3-WAY VALVE,
BUTTERFLY
STYLE
HANDWHEEL ACTUATOR,
RISING STEM, OUTSIDE
SCREW AND YOKE (OS&Y)
HANDWHEEL ACTUATOR,
NON-RISING STEM
GEAR ACTUATOR
(HANDWHEEL OR CRANK)
LEVER ACTUATOR
SEE AUTOMATIC ACTUATOR
SYMBOLS (TYP)
STRAINER - BASKET TYPE
AIR SEPARATOR
GRAND SENSIBLE HEATGSH
GTH GRAND TOTAL HEAT
SHGC SOLAR HEAT GAIN COEFFICIENT
SC SHADING COEFFICIENT
WELD NECK FLANGEWNF
RADIUS ELBOW
(R=1.5W UON)
FLAT OVAL DUCT
(W=MAJOR AXIS WIDTH,
D=MINOR AXIS DIAMETER)
DUCT SLOPE IN DIRECTION OF
AIR FLOW (R=RISE, D=DROP)
UNLINED DUCTWORK. FIRST
DIMENSION (W) IS SIDE SHOWN
ACOUSTICALLY LINED DUCTWORK.
FIRST DIMENSION (W) IS SIDE SHOWN
AD AD
AD
ACCESS DOOR
FIRE DAMPER (FD) OR COMBINATION
FIRE/SMOKE DAMPER (FSD)
MOTORIZED VOLUME DAMPER,
ACTUATOR TYPE AS SPECIFIED
MANUAL ACTUATOR SYMBOLS
BACKDRAFT DAMPER
QTY QUANTITY
ELBOW, 90 DEGREE
(LONG RADIUS UON)
ELBOW, 45 DEGREE
(LONG RADIUS UON)
VACUUM BREAKER
WATER METER
SPHERICAL
FLEXIBLE COUPLING
STRAINER - "Y"
TYPE WITH BLOW
DOWN
VENTURI FLOW METER
FLAT ON TOP
FOB
FOT
FLAT ON BOTTOM
OWNER FURNISHED / CONTRACTOR INSTALLEDOFCI
OFFSET, RECTANGULAR DUCT
(45° ELBOWS UON)
BRANCH DUCT TAP
(FLOW TO OR FROM
BRANCH DUCT)
2-WAY T-SPLIT
(FLOWS DIVERGING
ONLY)
MITERED ELBOW
(WITH TURNING VANES UON)
DUCT TRANSTITION,
ASYMETRIC (RECT x RECT)
DUCT
TRANSTITION
(RECT x ROUND)
DUCT TRANSTITION,
SYMETRIC (RECT x RECT)
RECT RECTANGULAR [DUCT]
ROOF DRAIN
RACK RACK
RACK
RACK
SELF-ACTUATING REGULATOR
(DIAPHRAGM-TYPE ACTUATOR UON)
SPIN-IN FITTING WITH DAMPER,
FITTING TYPE AS SPECIFIED
DUCT UNDER POSITIVE PRESSURE,
SECTION TOWARD VIEWER
DUCT UNDER NEGATIVE PRESSURE,
SECTION AWAY FROM VIEWER
DUCT UNDER POSITIVE PRESSURE,
SECTION AWAY FROM VIEWER
x = HOUR RATING
DESIGN CONDITIONS
NFPA 90A INSTALLATION OF AIR CONDITIONING AND VENTILATING
VENTILATING SYSTEMS - 2015 EDITION
4. INSTALL MANUAL AIR VENTS AT THE HIGH POINTS OF THE PIPING SYSTEMS.
6. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT
STRESSING PIPE OR EQUIPMENT CONNECTED.
7. INSTALL VALVES WITH STEMS UPRIGHT OR HORIZONTAL, NOT INVERTED.
8. INSTALL VALVES IN ACCESSIBLE LOCATIONS. INSTALL ACCESS DOORS IN
PARTITIONS WHERE VALVES WOULD OTHER WISE BE INACCESSIBLE.
9. WHEN SOCKET WELD OR SOLDER END VALVES ARE INSTALLED, SPECIAL CARE
SHALL BE TAKEN TO AVOID OVERHEATING AND DAMAGING THE VALVE BODY,
TRIM OR PACKING.
10. IDENTIFY EACH PIPE WITH LABELING AS REQUIRED BY SPECIFICATIONS.
11. SLEEVE ALL PIPING THAT PENETRATES FIRE RATED WALLS, FLOORS AND
PARTITIONS. PENETRATIONS SHALL BE SEALED WITH A U.L. LISTED ASSEMBLY
TO PROVIDE A RATING EQUAL TO OR GREATER THAN THAT OF THE
PENETRATED WALL, FLOOR OR PARTITION.
12. SLEEVE ALL PIPING THAT PENETRATES EXTERIOR BUILDING WALLS AND GRADE
BEAMS. SEAL PENETRATIONS WATERTIGHT.
13. COORDINATE WITH OTHER TRADES BEFORE FABRICATION OR INSTALLATION OF
ANY SYSTEMS.
14. EXISTING DUCTWORK, PIPING AND EQUIPMENT SHOWN ON THESE DRAWINGS
INDICATES THE GENERAL LOCATION AND ROUTING. THE ACTUAL LOCATION
SHALL BE DETERMINED BY THE CONTRACTOR WHO SHALL COORDINATE ALL
WORK WITH ALL TRADES NECESSARY TO INSTALL NEW DUCTWORK, PIPING OR
EQUIPMENT AS SHOWN ON THE DRAWING.
15. THESE DRAWINGS DO NOT NECESSARILY SHOW ALL OFFSETS OR ELEVATION
DIFFERENCES WHICH MAY BE NECESSARY FOR THE COMPLETE INSTALLATION.
16. ALL NEW DUCT SHALL BE EXTERNALLY INSULATED UON.
17. WHERE REMOVAL OF EXISTING DUCTWORK OR PORTIONS OF ANY AIR SYSTEM
IS NECESSARY, THE DUCT SHALL BE PATCHED AND SEALED AIRTIGHT USING
PATCH OF SAME MATERIAL AND EQUAL OR GREATER THICKNESS AS EXISTING.
PATCHES SHALL BE ATTACHED WITH SHEET METAL SCREWS OR OTHER MEANS
OF POSITIVE ATTACHMENT (WELDING, BONDING, ETC.) AS SPECIFIED FOR THE
PARTICULAR DUCT SYSTEM. NEW INSULATION MATERIAL AND ITS THERMAL
PROPERTIES SHALL BE EQUAL TO OR BETTER THAN EXISTING AND SHALL BE
PATCHED AND SEALED TO MATCH EXISTING INSULATION.
18. NUMBER SHOWN IN PARENTHESIS (100) IS CFM OF EXISTING AIR TERMINAL,
DUCT, OR AIR DEVICE AND IS FOR INFORMATION ONLY.
19. COORDINATE ALL REMODEL WORK WITH NEW CONSTRUCTION AND OTHER
TRADES.
20. THE CONTRACTOR SHALL ADJUST AND BALANCE ALL MECHANICAL SYSTEMS
TO DESIGN SETTINGS AS SHOWN AND SHALL REBALANCE TO RESTORE
SETTINGS OF SYSTEMS TEMPORARILY ALTERED FOR THE PURPOSES OF
COMPLETING THE WORK OF THIS PROJECT.
21. NOTIFY AND COORDINATE WITH OWNER PRIOR TO SHUTDOWN OF ANY
EQUIPMENT. SHUTDOWN TIME TO BE MINIMUM.
22. ANY ITEMS DAMAGED DURING DEMOLITION SHALL BE REPLACED WITH NEW
MATERIALS TO MATCH EXISTING.
23. CONTRACTOR SHALL PROVIDE TEMPORARY DUCTWORK, ELECTRICAL SERVICE,
PIPING OR OTHER BUILDING SERVICES AS REQUIRED TO KEEP OTHER AREAS IN
OPERATION DURING REMODELING. NOTIFY OWNER PRIOR TO SHUT-DOWN FOR
ANY TEMPORARY SERVICE REQUIREMENTS.
24. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF
CEILING-MOUNTED HVAC DEVICES AND EQUIPMENT.
25. DUCT ROUTING CHANGES MADE BY THE CONTRACTOR FOR THE PURPOSE OF
ACCOMMODATING FIELD CONDITIONS SHALL INCLUDE FIRE DAMPERS AND
COMBINATION FIRE/SMOKE DAMPERS IN RATED PARTITIONS AS SHOWN IN
ORIGINAL ROUTING ARRANGEMENTS.
26. FURNISH AND INSTALL ACCESS DOORS (AD) IN THE DUCTWORK IMMEDIATELY
ADJACENT TO EACH RATED DAMPER WHICH HAS A FUSIBLE LINK. PARTITIONS
SHALL BE PROVIDED WITH ACCESS DOORS TO PROVIDE SERVICE AND ACCESS
TO DAMPER ACCESS DOORS,
27. FIRE, SMOKE, AND COMBINATION FIRE/SMOKE DAMPERS SHALL BE UL
APPROVED, SHALL BEAR THE UL LABEL AND SHALL COMPLY WITH NFPA
BULLETIN NO. 90A. FULLY-OPEN DAMPERS SHALL NOT HAVE ANY
PROJECTIONS INTO THE AIRSTREAM.
28. ABANDONED DUCT SHALL BE REMOVED WHERE INDICATED ON THE
DRAWINGS. DUCT REMAINING IN PLACE SHALL BE CAPPED AND SEALED AIR
TIGHT AT POINT(S) OF DEMOLITION.
29. NEW HOLES THROUGH EXISTING FLOORS AND NO GREATER THAN 6" DIAMETER
SHALL BE CORE DRILLED. AVOID BEAMS AND JOIST LEGS.
30. ALL DUCT SIZES SHOWN HEREIN REPRESENT INSIDE CLEAR DIMENSIONS.
EXTERNAL SHEET METAL DIMENSIONS OF INTERNALLY-LINED DUCTWORK SHALL
BE ADJUSTED TO ALLOW FOR THICKNESS OF LINING.
31. THE OWNER SHALL HAVE THE OPTION TO DESIGNATE ANY MATERIALS
REMOVED OR DEMOLISHED DURING THIS WORK AS "RECYCLABLE" AND SHALL
HAVE FINAL DISPOSITION OVER THE DISPOSAL OF THESE MATERIALS. ALL
MATERIALS REMOVED/DEMOLISHED BY THE CONTRACTOR FOR THIS JOB AND
NOT RETAINED BY THE OWNER FOR RECYCLING OR OTHER PURPOSES SHALL
BE DISPOSED OFF-SITE BY THE CONTRACTOR.
32. ANY AND ALL WATER CONNECTIONS MADE FOR THE PURPOSE OF CLEANING
TOOLS OR THE WORK AREA OR FOR ANY OTHER CONSTRUCTION-RELATED
PURPOSES SHALL BE MADE ONLY TO DOMESTIC WATER HOSE BIBBS OR TO
CONTRACTOR-SUPPLIED WATER SOURCES. FOR THESE PURPOSES,
CONNECTIONS SHALL NOT BE MADE TO FIRE WATER, CHILLED WATER,
CONDENSER WATER, HEATING HOT WATER, DOMESTIC HOT WATER OR ANY
OTHER TREATED WATER SOURCE UNLESS REQUIRED AS PART OF WORK ON
THESE SYSTEMS.
33. EXCEPT WHERE REQUIRED AT EQUIPMENT NOZZLES, FLANGES SHALL BE
RAISED FACE WELD-NECK.
34. INSTALL DIELECTRIC FITTINGS AT ALL FERROUS PIPE CONNECTIONS TO
NON-FERROUS METALLIC PIPE OR EQUIPMENT.
35. BULLHEAD TEES SHALL NOT BE USED TO JOIN CONVERGING (RETURN)
FLOWS, REGARDLESS OF ARRANGEMENT SHOWN ON PLANS.
36. PROVIDE ESCUTCHEON PLATES WHERE PIPES EXPOSED TO VIEW PENETRATE
FINISHED WALLS.
37. PROVIDE DRAIN VALVES AT LOW POINTS OF PIPING SECTIONS, EQUIPMENT
CONNECTIONS AND VENTS AT HIGH POINTS. PROVIDE HOSE BIBB
CONNECTIONS AT DRAIN VALVES WHICH DO NOT DISCHARGE DIRECTLY OVER
OR ARE NOT PIPED DIRECTLY TO AN APPROPRIATE DRAIN.
38. PIPING, DUCTWORK OR EQUIPMENT CONNECTIONS OPENED BY DEMOLITION OR
RENOVATION SHALL BE TEMPORARILY SEALED TO KEEP OUT FOREIGN MATTER
UNTIL SUCH TIME AS RECONNECTIONS ARE MADE.
39. ALL PIPING RUN-OUTS TO VV AND CV TERMINAL UNIT HOT WATER COILS
SHALL BE 3/4" NPS UNLESS NOTED OTHERWISE.
40. PROVIDE 4" HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED EQUIPMENT INSIDE
BUILDING AND 6" FOR OUTDOOR, UON.
41. DUCT RUN-OUTS TO TERMINAL AIR DEVICES SHALL BE THE SAME SIZE AS
DEVICE NECK AND BE AT LEAST THREE DUCT DIAMETERS LONG OF STRAIGHT
DUCT. SEE AIR FLOW RATE SCHEDULE IN AIR DISTRIBUTION DEVICE
SCHEDULE ON 600-SERIES SHEET(S).
42. VV AND CV TERMINAL UNITS PRIMARY SUPPLY AIR RUN-OUTS SHALL BE THE
SAME SIZE AS THE PRIMARY INLET CONNECTION. RE: TERMINAL UNIT
SCHEDULE FOR INLET SIZE.
43. CONTRACTOR SHALL AVOID DAMAGE TO SYSTEMS WHICH ARE THE WORK OF
OTHER TRADES. ANY SYSTEM COMPONENTS WHICH ARE DAMAGED AND ARE
NOT IN THE CONTRACTOR'S SCOPE OF WORK SHALL BE REPAIRED, BY THE
CONTRACTOR, TO THE AS-INSTALLED CONDITION.
44. ALL MATERIALS IN THE PLENUM SPACE SHALL BE NONCOMBUSTIBLE.
45. FLEXIBLE SUPPLY DUCT RUNOUT LENGTHS SHALL NOT EXCEED 6'-0", FULLY
DEVELOPED.
INTERNATIONAL BUILDING CODE - 2015 EDITION
INTERNATIONAL MECHANICAL CODE - 2015 EDITION
SUMMER EVAP.
DESIGN AIR TEMPERATURES
SUMMER
OUTSIDE
CLIMATE ZONE 2A (TAMPA, FLORIDA)
INSIDE
MISCELLANEOUS SYMBOLS
(D)
(R)
(E)
(N)
EQUIPMENT DESIGNATIONS
PIPE SECTION
PIPE BREAK
FLOW ARROW
STANDARD BREAK / RECTANGULAR DUCT BREAK
SAW CUT SLAB AREA FOR INSTALLATION OF NEW
ITEMS
KEYED NOTE
POINT OF DISCONNECTION
POINT OF CONNECTION (NEW TO EXISTING)
NEW ITEMS (PIPING/DUCTWORK/EQUIPMENT)
EXISTING ITEMS TO REMAIN
EXISTING ITEMS TO BE DEMOLISHED OR RELOCATED
LIMIT OF EXISTING ITEMS TO BE REMOVED
NEW ITEM
(NOTATION SHOWN AS
NECESSARY FOR CLARIFICATION)
EXISTING ITEM
(NOTATION SHOWN AS
NECESSARY FOR CLARIFICATION)
EXISTING ITEM TO BE RELOCATED
(NOTATION SHOWN AS
NECESSARY FOR CLARIFICATION)
EXISTING ITEM TO BE DEMOLISHED
(NOTATION SHOWN AS NECESSARY
FOR CLARIFICATION)
ROOM-MOUNTED THERMOSTAT OR TEMPERATURE
SENSOR
ROOM-MOUNTED HUMIDISTAT OR HUMIDITY SENSOR
ROOM-MOUNTED SMOKE DETECTOR
DUCT-MOUNTED THERMOSTAT OR
TEMPERATURE SENSOR
DUCT-MOUNTED HUMIDISTAT OR HUMIDITY SENSOR
DUCT-MOUNTED SMOKE DETECTOR
APPLICABLE CODES
AND STANDARDS
FLM FLOW METER
CFM X
UCD 1"
UNDERCUT DOOR (UNDERCUT HEIGHT SHOWN)
SUPPLY AIRFLOW
LOUVER
RETURN OR EXHAUST AIRFLOW
FxF
SIDEWALL GRILLE OR REGISTER
DESIGN CFM
MARK (SEE SCHEDULE FOR TYPE, SERVICE
AND CONSTRUCTION)
FACE SIZE (INCHES)
SLOT DIFFUSER
MARK (SEE SCHEDULE FOR WIDTH AND NUMBER OF
SLOTS, NECK SIZE AND CONSTRUCTION)
LENGTH (FEET)
DESIGN CFM
CFM X L
DG DOOR GRILLE
CFM X
CFM X
CEILING RETURN OR EXHAUST
ARROWS, IF SHOWN, INDICATE THROW PATTERN.
LACK OF ARROWS AT CEILING DIFFUSERS
INDICATES SCHEDULED THROW PATTERN UON.
MARK (SEE SCHEDULE FOR FACE SIZE, NECK
SIZE AND CONSTRUCTION)
DESIGN CFMRECTANGULARROUND
VV (VARIABLE-VOLUME) OR CV (CONSTANT-VOLUME)
TERMINAL UNIT
(SHOWN WITH TERMINAL HEATING COIL)
CONSTANT-VOLUME FAN-POWERED TERMINAL UNIT
FLEXIBLE CONNECTIONS AT PRIMARY AIR INLET AND UNIT
DISCHARGE (TYP. FOR ALL FAN-POWERED TERMINAL
UNITS)
92.4°F DB / 80.5°F WB
81.5°F WB
75-86°F DB / 20-60% RH
COEFFICIENT - VALVE FLOWCv
CONTRACTOR INSTALLED VV VARIABLE-VOLUME [FLOW]
C [THERMAL] CONDUCTANCE
THERMAL CONDUCTIVITYk
STAIRWELL PRESSURIZATION FANSPF
SD SMOKE DAMPER
SUPPLY AIR FANSAF
ASHRAE STANDARD 90.1 ENERGY STANDARD FOR BUILDINGS
CDC CONDENSATE DRAIN COOLER
HUMIDIFIERH
HIGH EFFICIENCY PARTICULATE ARRESTANCEHEPA
HEPA FILTER CABINETHFC
ASHRAE STANDARD 62.1 VENTILATION FOR ACCEPTABLE INDOOR
AIR QUALITY - 2007 EDITION
EXCEPT LOW RISE RESIDENTIAL BUILDINGS - 2013 EDITION
NFPA 96 STANDARD FOR VENTILATION CONTROL AND FIRE
PROTECTION OF COMMERCIAL COOKING OPERATIONS - 2014 EDITION
NFPA 101 LIFE SAFETY CODE - 2013 EDITION
T
H
S
T
H
S
1. THIS IS A STANDARD LEGEND SHEET. SOME INFORMATION ON THIS SHEET
MAY NOT NECESSARILY APPLY TO THIS PROJECT.
2. ISOLATION VALVES SHALL BE PROVIDED IN ALL BRANCH PIPING AND AT
EQUIPMENT CONNECTIONS.
3. PIPING CONNECTIONS TO ALL EQUIPMENT SHALL BE FABRICATED WITH THE
ISOLATION VALVES, FLANGES AND/OR UNIONS POSITIONED TO ALLOW REMOVAL
AND SERVICE OF THE COMPONENT PARTS.
5. ROUTE PIPING IN AN ORDERLY MANNER AND MAINTAIN PROPER GRADES.
INSTALL TO CONSERVE HEADROOM AND TO CREATE MINIMUM INTERFERENCE
WITH USE OF SPACE. ROUTE EXPOSED PIPING PARALLEL TO BUILDING LINES.
GROUP PIPING AT COMMON BOP ELEVATIONS WHENEVER PRACTICAL. PIPES
LOCATED IN CONCEALED SPACES SHALL BE ROUTED CLOSE TO THE BUILDING
STRUCTURE UON.
CEILING SUPPLY
MARK (SEE SCHEDULE FOR FACE SIZE, NECK
SIZE AND CONSTRUCTION)
DESIGN CFM
GENERAL NOTES (CONT.)
DRAWING TITLE
X
XX.XX
EXAMPLE: ASSUME A SECTION IS CUT ON DWG. P2.01 WITH A
TAG OF 1/P6.01. THE SECTION No. 1 IS ON DRAWING No. P6.01.
SHEET NO. OF THE PACKAGE ON WHICH
SECTION IS DRAWN
SECTION NUMBER
DIRECTION OF CUTTING PLANE
SECTION OR DETAIL NUMBER
SCALE OF SECTION OR DETAIL
DETAIL NUMBER
SCALE: 1/4" = 1'-0"
DRAWING TITLE1
GRAPHIC SYMBOLS
SHEET NO. ON WHICH DETAIL
IS DRAWN
M-501
2" CHWS
2" CHWS
SYSTEM SERVICE ABBREVIATION
NOMINAL PIPE SIZE (IN
INCHES)
EXAMPLE:
PIPING DESIGNATION
VA HVAC DESIGN MANUAL
WINTER 38.4°F DB 40-70°F DB / 20-60% RH
ST STEAM TRAP
ROOM-MOUNTED CO2 SENSORC
DUCT MOUNTED PRESSURE DIFFERENTIAL TRANSMITTERPDT
REFRIGERANT PURGERFTP
CMUW CONDENSATE MAKE-UP WATER
BD BLAST DAMPER
RECORD DOCUMENTS
THESE RECORD DOCUMENTS HAVE
BEEN PREPARED BASED ON
INFORMATION PROVIDED BY OTHERS.
PAGE SOUTHERLAND PAGE, INC. HAS
NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION
AND SHALL NOT BE RESPONSIBLE FOR
ANY ERRORS OR OMISSIONS THAT MAY
BE INCORPORATED AS A RESULT OF
ERRONEOUS INFORMATION PROVIDED
BY OTHERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved Project Director:
VA FORM 08 - 6231
A
FULLY SPRINKLEREDU.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGN BUILD TEAM
321 4 5 6 7 8 9 10
Page Southerland Page, Inc.
pagethink.com
TEL
ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING
Austin / Dallas / Denver / Houston / San Francisco / Washington DC /
International Affiliate Offices
400 W. Cesar Chavez Street Fifth Floor
Austin, TX 78701 512 472 6721
512 477 3211
VA-0007-2016JAMES A. HALEY VETERANS'
HOSPITAL - NEW BED TOWER
Project Abbreviation:
13000 BRUCE B DOWNS BLVD, TAMPA, FL 33612
US ARMY CORPS OF ENGINEERS
STAMP
JAHVHNBT
135 W Central Blvd. Suite 950
Orlando, FL 32801
Turner Construction turnerconstruction.com
TEL
FAX
407 210 2500
TC 180221 | PSP 117265
CONTRACTOR:
DESIGNER:
B
IM
/1
-V A
T a m p a N e w
B e d to w e r/
B
M
-R
-C E
N T
R A
L .r v t
/2 /2
:4
:4
P M
100.M-001
MECHANICAL - LEGENDS,
ABBREVIATIONS, AND GEN. NOTES
03 JAN 2023 BH CD
FINAL AS-BUILT
SUBMISSION
Revision Number
Revisions: Date:
1. REFER TO GENERAL NOTES ON 100.M-001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. DUCTWORK CONNECTIONS TO TERMINAL UNITS TO MATCH THE INLET OPENINGS OF THE UNITS UNLESS NOTED
OTHERWISE. REFER TO VAV BOX SCHEDULE FOR INLET SIZES.
3. ALL BRANCH DUCTS TO BE SIZE OF GRILLE NECK LISTED ON THE AIR DEVICE SCHEDULE UNLESS NOTED OTHERWISE.
4. VAV BOXES AND FAN COIL UNITS SHALL BE FURNISHED WITH ZONE MOUNTED THERMOSTATS.
5. PROVIDE BALANCING DAMPER IN BRANCH DUCT TO ALL EXHAUST AND RETURN GRILLE LOCATED IN HARD CEILINGS. DO
NOT USE DAMPER AT GRILLE FOR BALANCING.
6. DRAWINGS SHOW COORDINATED MINIMUM REQUIRED STRAIGHT RUN OF DUCT INLET FOR TERMINAL UNITS FOLLOWING
TRANSITION FITTINGS.
7. MOUNT EQUIPMENT LOCATED ABOVE THE CEILING AS CLOSE TO CEILING AS POSSIBLE TO ALLOW FOR EASE OF
SERVICEABILITY.
8. ACCESS DOORS ARE REQUIRED FOR GREASE EXHAUST DUCT AT EVERY TURN AND AT A MINIMUM OF EVERY 20 FEET.
9. CONTACT GENERAL CONTRACTOR PRIOR TO ANY DISTURBANCE IN EXISTING BUILDINGS. WORK PLANS ARE REQUIRED
FOR ANY WORK IN EXISTING BUILDINGS. WORK PLANS SHALL ADDRESS ANY IDENTIFIED HAZARDOUS MATERIALS AND INCLUDE PROPER PROTOCOLS. SEE SPECIFICATIONS 028311 - ASBESTOS ABATEMENT AND 028333.13 - LEAD-BASED
PAINT REMOVAL FOR ANY WORK IN AREAS IDENTIFIED IN HAVING HAZARDOUS MATERIALS.
C
MATCHLINE
SEE /F1 100.MH-100-A
215 A
/1
LP
B
A
C E F H
G
M
AT
C H
LI
N
E
R
EF
F1
0.
M H
-1
-B
B1
100.M-303
FCU-G04
30/20 LP
40/20 MP
FCU-G07
FCU-G09
(REDUNDANT)
VAV-05-03
VAV-05-04
VAV-05-05
VAV-05-02
FCU-G10
310 A
/2
M
P
125 A
100 A 100 A
125 A 310 A
120 A 120 A
165 A
165 A
150 A 80 A
225 A
150 O 10 x 6
225 F
275 F 270 F
275 F
225 F 150 F
150 F
115 H
100 K
150 F
90 K
55 K
400 D
225 D
300 A 285 A
65 A
385 A
320 O 20 x 6
320 O 20 x 6
195 N 8 x 6
320 N 20 x 6
320 N 20 x 6
150 N 10 x 6
195 O 8 x 6
320 N 20 x 4
320 O 20 x 4
320 O 20 x 4
320 N 20 x 4
400 D
580 O 30 x 6
580 N 24 x 6
T T T
T T
T
T
FD
T
205 N 12 x 6
280 N 12 x 6
D
FCU-G06
GB001-100
COMPUTER
TERMINAL
SERVER
GB003-100
COMMAND
SERVER
GB002-100
TLT/
SHWR,
STAFF
GA060-100
ELEC
V0-04-100
SERVICE
ELEV
GA012-100
DISPOSAL
CHUTE
ROOM,
TRASH
GA011-100
DISPOSAL
CHUTE
ROOM,
LINEN
GA010-100
HAC
GA009-100
RECEIVING
FOOD
COURT/
SERVICE
GB000-100
ESSENTIAL
ELECTRICAL
ROOM
GA005-100
PATIENT
TRAY
ASSEMBLY
GA009C-100
SANITATION
RECYCLING
GA007-100
MED
AIR/VAC
GA054-100
OI&T
GA058-100
SIGNAL GA009A-100
ELEV
MACHINE
ROOM
GA004-100
EQUIPMENT
DISTRIBUTION
GA013-100
TUG /
STORAGE
GA014-100
WASTE
PUMPER
SYSTEM
GA005A-100
HAC
C0-04-100
CORRIDOR
ELEVATOR
MH 8
ELEVATOR
MH 7
C0-01-100
CORRIDOR
ELEVATOR
CS1
C0-02-100
CORRIDOR
GA009B-100
RECEIVING
AREA
C0-06-100
CONNECTOR
CORRIDOR
GB006-100
MECHANICAL
ROOM
ELEVATOR
P 1
GA006-100
FIRE
PUMP
EXTERIOR
GB008-100
ELEVATOR
PIT
C0-03-100
CORRIDOR
EXTERIOR
VAV-05-06
FCU-G11
(REDUNDANT)
FCU-G08
/2
M
P
/1
LP
VAV-05-07
20/14 LP
20/14 LP
20/8 LP
10/10 LP
10/10 LP
24/6 LP
/6
L P
18/8 LP
18/8 LP
18/14 LP
20/16 MP
16/16 LP
20/14 LP
/6
L P
255 A
H-08 H-09
/2
M
P
225 F
180 A
180 A 180 A
/2
LP
/2
LP
/6
L P
/6
L P
18/6 LP
F1
100.M-402
PDT
445 O 18 x 6
VAV-05-08
16/10 MP
FT-01
CRP-01
DHX-02
DHX-01
DT-09
DT-08
HX-02
FD
8" ø
T
8"ø
125 H
TT
F1
100.M-303
255 D
215 A 215 A 215 A
215 A
215 A
MATCHLINE
SEE /B1 100.MH-100-A
/1
LP
10/10 LP
10/12 LP
20/10 LP
/1
LP
10/12 LP
32/20 MP
210 N 8 x 8
(BELOW)
210 N 8 x 8
210 N 8 x 8
/1
M
P
20/10 LP
10"ø
VAV-05-01
16/12 MP
T
26/20 MP
205 O 12 x 6
280 O 12 x 6
22/20 LP
12/10 LP
14/10 LP
10/10 LP
14/12 LP
6"ø
600 D
600 D
90 H
GB005A-100
COMPRESSOR
ROOM
14/10 LP
12/12 LP
12/12 LP
12/10 MP
14/10 MP
20/14 LP
/1
LP
10"ø
14/12 LP
FCU-G05
(REDUNDANT)
H-07
T
DT-07
T
T
/6
L P
50 O 8 x 6
50 O 8 x 6
M
AT
C H
LI
N
E
R
EF
F1
.M
H -1
20/8 LP
20/8 LP
H H
H
30/14 LP
18/8 MP
"ø
/6
L P
8/6 LP
FD
FD
FD FD
FD
FD
FD
FD
FD
FD
445 O 18 x 6
RECORD DOCUMENTS
THESE RECORD DOCUMENTS HAVE
BEEN PREPARED BASED ON
INFORMATION PROVIDED BY OTHERS.
PAGE SOUTHERLAND PAGE, INC. HAS
NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION
AND SHALL NOT BE RESPONSIBLE FOR
ANY ERRORS OR OMISSIONS THAT MAY
BE INCORPORATED AS A RESULT OF
ERRONEOUS INFORMATION PROVIDED
BY OTHERS.
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved Project Director:
VA FORM 08 - 6231
A
FULLY SPRINKLEREDU.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGN BUILD TEAM
321 4 5 6 7 8 9 10
Key Plan
Page Southerland Page, Inc.
pagethink.com
TEL
ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING
Austin / Dallas / Denver / Houston / San Francisco / Washington DC /
International Affiliate Offices
400 W. Cesar Chavez Street Fifth Floor
Austin, TX 78701 512 472 6721
512 477 3211
VA-0007-2016JAMES A. HALEY VETERANS'
HOSPITAL - NEW BED TOWER
Project Abbreviation:
13000 BRUCE B DOWNS BLVD, TAMPA, FL 33612
US ARMY CORPS OF ENGINEERS
STAMP
JAHVHNBT
135 W Central Blvd. Suite 950
Orlando, FL 32801
Turner Construction turnerconstruction.com
TEL
FAX
407 210 2500
TC 180221 | PSP 117265
CONTRACTOR:
DESIGNER:
B A
B
IM
/1
-V A
T a m p a N e w
B e d to w e r/
B
M
-R
-C E
N T
R A
L .r v t
/2 /2
:5
:5
P M
100.MH-100-A
MECHANICAL - FLOOR PLAN - LEVEL G -
AREA A
03 JAN 2023 BH CD
FINAL AS-BUILT
SUBMISSION
16'4' 8'0-4'
GENERAL NOTES
1 KITCHEN COMPRESSOR RACK. SEE 100.MP-100A FOR PIPING
CONNECTIONS. REFERENCE FOOD SERVICE FOR MORE INFORMATION.
2 GATEWAY TO MONITOR STEAM REPEATERS AND REPORT TO BAS OVER
BACNET. REQUIRES 120V, SINGLE PHASE 60 HZ ELECTRICAL CONNECTION.
3 BAS CONTROL PANEL.
4 GENERAL EXHAUST DUCT 10X10 FROM LEVEL G UP TO LEVEL 1.
KEYED NOTES
NUMBER DESCRIPTION
SCALE: 1/8" = 1'-0"B1 MECHANICAL - FLOOR PLAN - LEVEL G - AREA A N. CORRIDOR
Revision Number
Revisions: Date:
1 POST IFC ADDENDUM 4 13 MAY 2021
SCALE: 1/8" = 1'-0"F1 MECHANICAL - FLOOR PLAN - LEVEL G - AREA A
5 NOT USED.
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
VHATAMJamesR Highlight
CT-01 CT-02
CT-03
(REDUNDANT)
M
F H J K
G
F1
100.M-301
C1
100.M-301
F1
100.M-302
B1
100.M-303
FCU-G04
30/20 LP
40/20 MP
SS-01
VAV-05-04
VAV-05-05
/2
LP
FCU-G01
310 A
/2
M
P
120 A
150 A 80 A
225 A
150 O 10 x 6
270 F
225 F
100 K
55 K
150 N 10 x 6
400 D
580 O 30 x 6
580 N 24 x 6
4330 O 34 x 14
4330 N 32 x 20
T
GB004-100
ELECTRICAL
SUBSTATION
ROOM
SG-02-100
STAIR 2
LEVEL G
GB005-100
MECHANICAL
ROOM
SG-02-100
STAIR 2
LEVEL G
FD
T
205 N 12 x 6
280 N 12 x 6
FCU-G06
GB001-100
COMPUTER
TERMINAL
SERVER
GB003-100
COMMAND
SERVER
GB002-100
TLT/
SHWR,
STAFF
GA009-100
RECEIVING
FOOD
COURT/
SERVICE
GB000-100
ESSENTIAL
ELECTRICAL
ROOM
GA009C-100
SANITATION
RECYCLING
GA007-100
MED
AIR/VAC
GA009A-100
ELEV
MACHINE
ROOM
GA014-100
WASTE
PUMPER
SYSTEM
GA005A-100
HAC
C0-02-100
CORRIDOR
SG-02-100
STAIR 2
LEVEL G
GB006-100
MECHANICAL
ROOM
ELEVATOR
P 1
GA006-100
FIRE
PUMP
EXTERIOR
GB008-100
ELEVATOR
PIT
C0-03-100
CORRIDOR
EXTERIOR
SG-02-100
STAIR 2
LEVEL G
VAV-05-06
/2
M
P
/1
LP
VAV-05-07
M
AT
C H
LI
N
E
R
EF
F1
0.
M H
-1
-A
FCU-G03
255 A
32/20 LP
VFD-CT-01
VFD-CT-02
VFD-CT-03
/2
M
P
180 A
180 A 180 A
SG-02-100
STAIR 2
LEVEL G
EXTERIOR
SG-02-100
STAIR 2
LEVEL G
BT-1
BP-01
COOLING
TOWER
YARD
2630 O 34 x 14
2630 N 32 x 20
/2
LP
/2
LP
18/6 LP
34/14 LP
F1
100.M-401
F1
100.M-402
PDT
445 O 18 x 6
VAV-05-08
16/10 MP 30/6 LP
16/14 LP
"ø
890 N 18 x 10
FT-01
CRP-01
DHX-02
DHX-01
DCHX-01
F8
100.M-303
F6
100.M-303
F4
100.M-303
HX-02
FD
CS-01
ET-02
T
ET-02
T
F1
100.M-303
255 D
40/18 MP
32/20 MP
210 N 8 x 8
(BELOW)
210 N 8 x 8
210 N 8 x 8
/1
M
P
20/10 LP
10"ø
T
205 O 12 x 6
280 O 12 x 6
22/20 LP
14/10 LP
6"ø
HX-01
AS-02
ET-01
HWP-01
HWP-02
(REDUNDANT)
CH-03
(REDUNDANT)
CH-02
CH-01
AS-01
CHWPP-03
(REDUNDANT)
CHWPP-02
CHWPP-01
CHWBP-02
(REDUNDANT)
CHWBP-01
CWP-03
(REDUNDANT)
CWP-02
CWP-01
90 H
GB005A-100
COMPRESSOR
ROOM
/1
LP
CP-01
CP-02
(REDUNDANT)
VFD-CWP-03VFD-CWP-02VFD-CWP-01
VFD-CHWBP-02
VFD-CHWBP-01
VFD-CHWPP-03VFD-CHWPP-02VFD-CHWPP-01
FCU-G05
(REDUNDANT)
H-07
T
DT-07
T
T
8 8
8 8
L
H
30/14 LP
EDGE OF DOUBLE HEIGHT SPACE.
BP-02
(REDUNDANT)
FD
FD
FD FD
FD
FD
FD
FD
445 O 18 x 6
1. REFER TO GENERAL NOTES ON 100.M-001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. DUCTWORK CONNECTIONS TO TERMINAL UNITS TO MATCH THE INLET OPENINGS OF THE UNITS UNLESS NOTED
OTHERWISE. REFER TO VAV BOX SCHEDULE FOR INLET SIZES.
3. ALL BRANCH DUCTS TO BE SIZE OF GRILLE NECK LISTED ON THE AIR DEVICE SCHEDULE UNLESS NOTED OTHERWISE.
4. VAV BOXES AND FAN COIL UNITS SHALL BE FURNISHED WITH ZONE MOUNTED THERMOSTATS.
5. PROVIDE BALANCING DAMPER IN BRANCH DUCT TO ALL EXHAUST AND RETURN GRILLE LOCATED IN HARD CEILINGS. DO
NOT USE DAMPER AT GRILLE FOR BALANCING.
6. DRAWINGS SHOW COORDINATED MINIMUM REQUIRED STRAIGHT RUN OF DUCT INLET FOR TERMINAL UNITS FOLLOWING
TRANSITION FITTINGS.
7. MOUNT EQUIPMENT LOCATED ABOVE THE CEILING AS CLOSE TO CEILING AS POSSIBLE TO ALLOW FOR EASE OF
SERVICEABILITY.
8. ACCESS DOORS ARE REQUIRED FOR GREASE EXHAUST DUCT AT EVERY TURN AND AT A MINIMUM OF EVERY 20 FEET.
9. CONTACT GENERAL CONTRACTOR PRIOR TO ANY DISTURBANCE IN EXISTING BUILDINGS. WORK PLANS ARE REQUIRED
FOR ANY WORK IN EXISTING BUILDINGS. WORK PLANS SHALL ADDRESS ANY IDENTIFIED HAZARDOUS MATERIALS AND INCLUDE PROPER PROTOCOLS. SEE SPECIFICATIONS 028311 - ASBESTOS ABATEMENT AND 028333.13 - LEAD-BASED
PAINT REMOVAL FOR ANY WORK IN AREAS IDENTIFIED IN HAVING HAZARDOUS MATERIALS.
RECORD DOCUMENTS
THESE RECORD DOCUMENTS HAVE
BEEN PREPARED BASED ON
INFORMATION PROVIDED BY OTHERS.
PAGE SOUTHERLAND PAGE, INC. HAS
NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION
AND SHALL NOT BE RESPONSIBLE FOR
ANY ERRORS OR OMISSIONS THAT MAY
BE INCORPORATED AS A RESULT OF
ERRONEOUS INFORMATION PROVIDED
BY OTHERS.
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved Project Director:
VA FORM 08 - 6231
A
FULLY SPRINKLEREDU.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGN BUILD TEAM
321 4 5 6 7 8 9 10
Key Plan
Page Southerland Page, Inc.
pagethink.com
TEL
ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING
Austin / Dallas / Denver / Houston / San Francisco / Washington DC /
International Affiliate Offices
400 W. Cesar Chavez Street Fifth Floor
Austin, TX 78701 512 472 6721
512 477 3211
VA-0007-2016JAMES A. HALEY VETERANS'
HOSPITAL - NEW BED TOWER
Project Abbreviation:
13000 BRUCE B DOWNS BLVD, TAMPA, FL 33612
US ARMY CORPS OF ENGINEERS
STAMP
JAHVHNBT
135 W Central Blvd. Suite 950
Orlando, FL 32801
Turner Construction turnerconstruction.com
TEL
FAX
407 210 2500
TC 180221 | PSP 117265
CONTRACTOR:
DESIGNER:
B A
B
IM
/1
-V A
T a m p a N e w
B e d to w e r/
B
M
-R
-C E
N T
R A
L .r v t
/2 /2
:5
:0
P M
100.MH-100-B
MECHANICAL - FLOOR PLAN - LEVEL G -
AREA B
03 JAN 2023 BH CD
FINAL AS-BUILT
SUBMISSION
16'4' 8'0-4'
SCALE: 1/8" = 1'-0"F1 MECHANICAL - FLOOR PLAN - LEVEL G - AREA B
GENERAL NOTES
KEYED NOTES
NUMBER DESCRIPTION
1 SUPPLY DUCT 40X20 FROM LEVEL G UP DOUBLE HEIGHT SPACE TO LEVEL 1.
2 RETURN DUCT 14X16 FROM LEVEL G UP DOUBLE HEIGHT SPACE TO LEVEL
1.
3 8" Ø GENERAL EXHAUST DUCT FROM LEVEL G UP THRU DOUBLE HEIGHT
SPACE TO LEVEL 1.
4 REFRIGERANT PURGE EXHAUST DUCT 16X16 ON LEVEL G UP DOUBLE
HEIGHT SPACE TO LEVEL 1. EXHAUST INLET TO MOUNTED 12" A.F.F. TO
CAPTURE REFRIGERANT.
5 20X30 RETURN DUCT FROM LEVEL G UP TO LEVEL 1.
6 6" Ø RETURN DUCT FROM LEVEL G UP TO LEVEL 1.
7 KITCHEN COMPRESSOR RACK. SEE 100.MP-100A FOR PIPING CONNECTIONS.
REFERENCE FOOD SERVICE FOR MORE INFORMATION.
8 BAS CONTROL PANEL.
9 WATER TREATMENT EQUIPMENT. PROVIDE WITH 3/4" PIPING CONNECTIONS
FOR FOUR(4) 55 GALLON CHEMICAL STORAGE TANKS AND PUMPS.
CHEMICALS SHALL BE ONE(1) CHILLED WATER SYSTEM CORROSION
INHIBITOR, TWO(2) CONDENSER WATER ALGAECIDES/BIOCIDES AND ONE(1)
CONDENSER WATER CORROSION INHIBITOR AS COORDINATED WITH THE
OWNER.
Revision Number
Revisions: Date:
1 POST IFC ADDENDUM 4 13 MAY 2021
10 NOT USED.
B
A C E F H
G
6 6
M
AT
C H
LI
N
E
R
EF
F1
0.
M H
-1
-B
B1
100.M-303
/2
M
P
28/20 MP
/2
LP
/2
M
P
/2
LP
18/16 LP
/2
LP
56/24 LP
16/10 LP
/8
L P
F C
U -1
(R
E D
U N
D A
N T
FCU-108
(REDUNDANT)
22/14 LP
/1
LP
VAV-01-10
VAV-01-12
VAV-01-11
VAV-01-13
VAV-01-14
VAV-01-16
V A
V -0
1-
FCU-109
VAV-01-05
VAV-01-04
VAV-01-03
VAV-01-06
22/12 LP
14/12 LP
12/12 LP
VAV-01-02
T
T
TTT
T
T
T
T
T C
C
FD FD
195 Q
185 A
225 A
350 A
225 A
335 A
250 O 12 x 6
250 O 12 x 6
250 O 12 x 6
250 O 12 x 6
250 O 12 x 6
250 O 12 x 6
290 A
385 A
385 A
385 A
370 D
385 A 385 A 385 A
385 A
385 A 75 A
105 H
400 A
400 A
400 A
320 A
205 A
635 D
385 A
385 A
205 D
160 H 270 A
165 H
165 H
175 H 175 H
295 A
295 A
65 A
MATCHLINE
SEE /1 100.MH-101-A1
D
VAV-01-15
VAV-01-07
VAV-01-09
EXH-506 EXH-506
EXH-544
EXH-318A EXH-318B
EXH-334
560 D
770 D
45 F
540 D
360 D
360 N 20 x 4
65 F
110 D
90 F
90 F
60 F 150 H
300 H
305 D
305 D
305 D
260 D
200 A
200 A
200 A
1A128-100
SERVING
AREA
1A162-100
RETAIL
DISPLAY
STORAGE
1B100-100
RETAIL
AREA
1A187-100
STORAGE,
REF/ FRZ
1A161-100
FEMALE
TOILET,
MULTIPLE
1A163-100
MALE
TOILET,
MULTIPLE
1A160-100
ELEC
1A158-100
SIGNAL
1A154-100
OI&T
1A169A-100
OFFICE,
SECURE
MONEY
1B110-100
VETERAN
MEMORIAL
1B111-100
FEMALE
TOILET,
MULTIPLE
1A137-100
RETAIL
AREA
(COFFEE)
1A125A-100
INFO
DESK
V1-04-100
SERVICE
ELEV
V1-03-100
PUBLIC
ELEV
1A184-100
FOOD
PREP &
PRODUCTION
1A137A-100
STORAGE
ROOM
1A169B-100
OFFICE,
VCS
CHIEF
1A169D-100
OFFICE,
VCS
ASST
CHIEF
1A169C-100
OFFICE,
VCS
ASST
CHIEF
1A169E-100
CUBICLE,
CLERK
1A173-100
LOCKER
ROOM
STAFF
1A171-100
LOCKER
ROOM
STAFF
1A175-100
LOUNGE,
STAFF
1A177-100
TOILET,
STAFF
1A179-100
TOILET,
STAFF
1A185-100
STORAGE,
REF/ FRZ
1A178-100
STORAGE,
RETAIL
1A128A-100
STORAGE,
NON-FOOD
1A170-100
VENDING
MACHINE
MASTER1A191-100
HAC
1A186-100
STORAGE,
REF/ FRZ
1A183-100
STORAGE,
REF/ FRZ
C1-11-100
CORRIDOR
C1-08-100
CORRIDOR
1A180-100
REMOTE
STORAGE,
RECV
1A110-100
STORAGE
1A194B-100
HAC
1A176-100
STORAGE,
DRY
FOOD
ELEVATOR
P 2
ELEVATOR
P 1
ELEVATOR
P 3
ELEVATOR
P 4
C1-10-100
CORRIDOR
1A110A-100
HAC
1A128B-100
SODA
SYSTEM
C1-14-100
CORRIDOR
1A152-100
DINING
AREA
1A125-100
LOBBY/WAITING
1A134-100
DINING
AREA
C1-09-100
CORRIDOR
1A125B-100
CUBICLE,
VOLUNTEER
1A194-100
POT
WASH
AREA
C1-17-100
CORRIDOR
1A125C-100
TELEPHONE
PUBLIC
C1-18-100
CORRIDOR
C1-12-100
CORRIDOR
1A194A-100
DISH
WASH
AREA
C1-20-100
CORRIDOR
1A194C-100
CLEAN
STORAGE
V1-01-100
PATIENT
ELEV
C1-08-100
CORRIDOR
1A152-100
DINING
AREA
C2-25-100
CORRIDOR
EXTERIOR
305 A
305 A
675 D
305 A
305 A
675 D
305 A
100 A
26/22 MP
20/18 MP
/3
M
P
195 Q
195 Q
195 Q
195 Q
195 Q
115 Q
115 Q
115 Q
115 Q
115 Q
115 Q
115 Q
115 Q
75 Q
75 Q
66/20 LP
/1
LP
1000 D
1000 D
/1
LP
/2
M
P
/2
M P
1000 D
1000 D
385 A
900 D
900 D
1500 D
135 D 135 H320 A
400 A
895 D 895 D
300 A
445 E
400 B400 B400 B400 B
385 A
895 D
75 A
150 D
/1
LP
/1
LP
12/10 LP
270 A
320 O 20 x 423/6 LP
24/5 LP
320 N 20 x 4
320 O 20 x 4
52/24 LP 56/24 LP
360 O 20 x 4
FCU-106
260 A
330 A 330 A
285 A
285 A
/1
LP
/1
LP
10/12 LP
245 A
245 A
65 B
160 H
/1
LP
10/14 LP
14/16 MP30/20 MP
370 D
370 D
370 D 895 D
50 C
20/18 LP
/2
LP
105 H
12/12 LP
105 A
135 B
100 I
90 I
60 A
120 B
235 A
130 D
/1
M
P
28/20 MP
/1
LP
16/16 LP
16/16 LP
/1
LP
8/
L P
12/14 LP
/1
M
P
12/14 MP
18/16 MP
18/12 LP
20/16 LP
/2
LP
28/24 MP54/34 MP
40/34 MP
/1
LP
14/18 LP
20/14 LP
/1
LP
14/20 LP
10/14 LP
16"ø
14/18 LP
10"ø
/2
LP
76/12 MP
/1
LP
20/20 MP
22/14 LP
8/6 LP
6/10 LP
12/10 LP
10/12 LP
10/10 LP
8/10 LP
64/26 LP
12/14 LP
14/14 LP
C
T
T T
T
T
T
T
FD
FD
FD
C
300 B
365 B
185 F
T
C
C
C T
C
T
16/14 LP
235 D
320 N 20 x 4
320 O 20 x 4
320 N 20 x 4
445 E
/2
LP
135 D
365 B
100 D
290 A
200 A
200 A
130 A
60 B
135 H
20/12 LP
6 7
14/16 LP
18/10 LP
/1
LP
18/10 LP
/1
LP
18/14 LP
/2
LP
/2
LP
/2
LP
/1
LP
1000 D
1000 D
1000 D
450 D
450 D
/1
LP
PDT
PDT
12/16 LP
FCU-107
320 O 20 x 4
320 N 20 x 4
UH-01
20/18 LP
20/18 LP
20/18 LP
FD FD
EXH-426
EXH-423
C
T
1A139-100
STORAGE
ROOM
TT
185 Q 185 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q
75 Q 90 Q 90 Q
145 Q 145 Q 185 Q 185 Q
185 Q
185 Q
185 Q
195 Q
50/16 MP
12 12
FD
FD FD
24/14 LP
FD
FD
12"ø
/8
L P
20/14 LP
14/14 LP
6/
LP
23/6 LP
FD
12/18 LP
16/14 LP
28/20 MP
14/18 LP
DT-11 DT-10
VAV-01-01
FD
50 O 6 x 8
50 O 6 x 8
10"ø
/1
M
P
M
AT
C H
LI
N
E
R
EF
D
.M H
-1
M
AT
C H
LI
N
E
R
EF
F4
.M
H -1
20/8 LP
/4
L P
20/4 LP
20/8 LP
225 A
120 D
350 A
350 A
325 D
325 D
12/14 LP
H-11 H-10
H H
10"ø
8" ø
18/10 LP
24/20 LP
12"ø
16"ø
16"ø
8/8 LP
16/10 LP
1. REFER TO GENERAL NOTES ON 100.M-001 FOR SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.
2. DUCTWORK CONNECTIONS TO TERMINAL UNITS TO MATCH THE INLET OPENINGS OF THE UNITS UNLESS NOTED
OTHERWISE. REFER TO VAV BOX SCHEDULE FOR INLET SIZES.
3. ALL BRANCH DUCTS TO BE SIZE OF GRILLE NECK LISTED ON THE AIR DEVICE SCHEDULE UNLESS NOTED OTHERWISE.
4. VAV BOXES AND FAN COIL UNITS SHALL BE FURNISHED WITH ZONE MOUNTED THERMOSTATS.
5. PROVIDE BALANCING DAMPER IN BRANCH DUCT TO ALL EXHAUST AND RETURN GRILLE LOCATED IN HARD CEILINGS. DO
NOT USE DAMPER AT GRILLE FOR BALANCING.
6. DRAWINGS SHOW COORDINATED MINIMUM REQUIRED STRAIGHT RUN OF DUCT INLET FOR TERMINAL UNITS FOLLOWING
TRANSITION FITTINGS.
7. MOUNT EQUIPMENT LOCATED ABOVE THE CEILING AS CLOSE TO CEILING AS POSSIBLE TO ALLOW FOR EASE OF
SERVICEABILITY.
8. ACCESS DOORS ARE REQUIRED FOR GREASE EXHAUST DUCT AT EVERY TURN AND AT A MINIMUM OF EVERY 20 FEET.
9. CONTACT GENERAL CONTRACTOR PRIOR TO ANY DISTURBANCE IN EXISTING BUILDINGS. WORK PLANS ARE REQUIRED
FOR ANY WORK IN EXISTING BUILDINGS. WORK PLANS SHALL ADDRESS ANY IDENTIFIED HAZARDOUS MATERIALS AND INCLUDE PROPER PROTOCOLS. SEE SPECIFICATIONS 028311 - ASBESTOS ABATEMENT AND 028333.13 - LEAD-BASED
PAINT REMOVAL FOR ANY WORK IN AREAS IDENTIFIED IN HAVING HAZARDOUS MATERIALS.
RECORD DOCUMENTS
THESE RECORD DOCUMENTS HAVE
BEEN PREPARED BASED ON
INFORMATION PROVIDED BY OTHERS.
PAGE SOUTHERLAND PAGE, INC. HAS
NOT VERIFIED THE ACCURACY AND/OR
COMPLETENESS OF THIS INFORMATION
AND SHALL NOT BE RESPONSIBLE FOR
ANY ERRORS OR OMISSIONS THAT MAY
BE INCORPORATED AS A RESULT OF
ERRONEOUS INFORMATION PROVIDED
BY OTHERS.
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved Project Director:
VA FORM 08 - 6231
A
FULLY SPRINKLEREDU.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGN BUILD TEAM
321 4 5 6 7 8 9 10
Key Plan
Page Southerland Page, Inc.
pagethink.com
TEL
ARCHITECTURE / ENGINEERING / INTERIORS / PLANNING / CONSULTING
Austin / Dallas / Denver / Houston / San Francisco / Washington DC /
International Affiliate Offices
400 W. Cesar Chavez Street Fifth Floor
Austin, TX 78701 512 472 6721
512 477 3211
VA-0007-2016JAMES A. HALEY VETERANS'
HOSPITAL - NEW BED TOWER
Project Abbreviation:
13000 BRUCE B DOWNS BLVD, TAMPA, FL 33612
US ARMY CORPS OF ENGINEERS
STAMP
JAHVHNBT
135 W Central Blvd. Suite 950
Orlando, FL 32801
Turner Construction turnerconstruction.com
TEL
FAX
407 210 2500
TC 180221 | PSP 117265
CONTRACTOR:
DESIGNER:
B A
B
IM
/1
-V A
T a m p a N e w
B e d to w e r/
B
M
-R
-C E
N T
R A
L .r v t
/2 /2
:5
:4
P M
100.MH-101-A
MECHANICAL - FLOOR PLAN - LEVEL 01 -
AREA A
03 JAN 2023 BH CD
FINAL AS-BUILT
SUBMISSION
16'4' 8'0-4'
SCALE: 1/8" = 1'-0"F1 MECHANICAL - FLOOR PLAN - LEVEL 01 - AREA A
GENERAL NOTES
1 GREASE EXHAUST DUCT 24X20 FROM LEVEL 1 UP TO LEVEL 2.
2 WET EXHAUST DUCT 12X12 FROM LEVEL 1 UP TO LEVEL 2.
3 GREASE EXHAUST DUCT 24X34 FROM LEVEL 1 UP TO LEVEL 2.
4 GENERAL EXHAUST DUCT 10X10 FROM LEVEL 1 AND 24X16 UP TO LEVEL
2. FIRE DAMPER LOCATED ON 10X10 DUCT IN FLOOR SLAB OF LEVEL 1.
5 RETURN DUCT 60X30 FROM LEVEL 1 UP TO LEVEL 2.
6 SUPPLY DUCT 8X56 FROM LEVEL 1 UP TO LEVEL 2.
7 RETURN DUCT 8X42 FROM LEVEL 1 UP TO LEVEL 2.
8 SUPPLY DUCT 22X24 FROM LEVEL 1 UP TO LEVEL 2 .
9 RETURN DUCT 22X20 FROM LEVEL 1 UP TO LEVEL 2.
10 SUPPLY DUCT 54X34 FROM LEVEL 1 UP TO LEVEL 2.
11 ALL GREASE EXHAUST DUCT SHALL BE CONTINUOUSLY WRAPPED WITH A
2-HOUR GREASE DUCT ENCLOSURE AND SLOPED 2% IN THE HORIZONTAL
TOWARDS HOOD. PROVIDE ACCESS DOORS NO MORE THAN 20 FEET
APART AND WITHIN 10 FEET OF ANY CHANGE IN DIRECTION GREATER
THAN 45 DEGREES.
12 PREFERRED GREASE DUCT ACCESS DOOR LOCATIONS. LOCATIONS TO
BE COORDINATED IN THE FIELD WITH FINALIZED INSTALL LOCATIONS,
MAINTAINING 20 FEET OR LESS DISTANCE APART AND WITHIN 10 FEET OF
CHANGE OF DIRECTION IF GREATER THAN 45 DEGREES.
13 TWO BAS CONTROL PANELS STACKED ON TOP OF EACH OTHER. ALLOW
FOR ONE FOOT OF CLEARANCE BETWEEN THEM.
14 6" Ø RETURN AIR DUCT DOWN TO LEVEL G.
KEYED NOTES
NUMBER DESCRIPTION
Revision Number
Revisions: Date:
1 POST IFC ADDENDUM 1 17 APR 2020
2 POST IFC ADDENDUM 2 23 SEP 2020
3 POST IFC ADDENDUM 4 13 MAY 2021
4 POST IFC ADDENDUM 6 24 SEP 2021
OTHERWISE. REFER TO VAV BOX SCHEDULE FOR INLET SIZES.
3. ALL BRANCH DUCTS TO BE SIZE OF GRILLE NECK LISTED ON THE AIR DEVICE SCHEDULE UNLESS NOTED OTHERWISE.
4. VAV BOXES AND FAN COIL UNITS SHALL BE FURNISHED WITH ZONE MOUNTED THERMOSTATS.
5. PROVIDE BALANCING DAMPER IN BRANCH DUCT TO ALL EXHAUST AND RETURN GRILLE LOCATED IN HARD CEILINGS. DO
NOT USE DAMPER AT GRILLE FOR BALANCING.
6. DRAWINGS SHOW COORDINATED MINIMUM REQUIRED STRAIGHT RUN OF DUCT INLET FOR TERMINAL UNITS FOLLOWING
TRANSITION FITTINGS.
7. MOUNT EQUIPMENT LOCATED ABOVE THE CEILING AS CLOSE TO CEILING AS POSSIBLE TO ALLOW FOR EASE OF
SERVICEABILITY.
8. ACCESS DOORS ARE REQUIRED FOR GREASE EXHAUST DUCT AT EVERY TURN AND AT A MINIMUM OF EVERY 20 FEET.
9. CONTACT GENERAL CONTRACTOR PRIOR TO ANY DISTURBANCE IN EXISTING BUILDINGS. WORK PLANS ARE REQUIRED
FOR ANY WORK IN EXISTING BUILDINGS. WORK PLANS SHALL ADDRESS ANY IDENTIFIED HAZARDOUS MATERIALS AND INCLUDE PROPER PROTOCOLS. SEE SPECIFICATIONS 028311 - ASBESTOS ABATEMENT AND 028333.13 - LEAD-BASED
PAINT REMOVAL FOR ANY WORK IN AREAS IDENTIFIED IN HAVING HAZARDOUS MATERIALS.
B
A C E F H
G
M
AT
C H
LI
N
E
R
EF
F1
0.
M H
-1
-B
48/28 MP
48/28 MP
/1
M
P
/2
M P
26/24 MP
16/16 MP
18/16 MP
/2
M
P
42/20 MP
20/16 MP
20/20 LP
/2
LP
/1
LP
14/12 LP
20/18 LP
/1
LP
/1
LP
20/24 LP
16/14 LP
16/14 LP
/1
LP
2A229-100
VENDING
MACHINE
AREA
2A286-100
STORAGE,
MEDICAL
GAS
VAV-02-33
VAV-02-25
VAV-02-30
VAV-02-15
VAV-02-14
VAV-02-16
VAV-02-24
VAV-02-23
VAV-02-22
FCU-203
(REDUNDANT)
VAV-02-20
VAV-02-18VAV-02-17
FCU-204
(REDUNDANT)
VAV-02-32
VAV-02-31
VAV-02-29
10/12 LP
6/12 LP
10/10 LP
VAV-02-27
VAV-02-28
22/18 LP
/1
LP
T
T
T
T
T
T
T T T T T T T T
T T
T
T
T T T
T
T
T
T
T
T
T
T
T
C T
T
C
C
C
C T
T C
CT
2A251-100
SICU
PATIENT
ROOM 9 2A263-100
SICU
PATIENT
ROOM 13
2A235-100
SICU
PATIENT
ROOM 3
2A257-100
SICU
PATIENT
ROOM 11
2A241-100
SICU
PATIENT
ROOM 5,
NEG
ISOLATION
2A247-100
SICU
PATIENT
ROOM 7 2A259-100
SICU
PATIENT
ROOM 12
2A231-100
SICU
PATIENT
ROOM 1
2A243-100
SICU
PATIENT
ROOM 6,
NEG
ISOLATION
2A265-100
SICU
PATIENT
ROOM 14
2A233-100
SICU
PATIENT
ROOM 2
2A249-100
SICU
PATIENT
ROOM 8
2A267-100
SICU
PATIENT
ROOM 15
2A237-100
SICU
PATIENT
ROOM 4
2A269-100
SICU
PATIENT
ROOM 16
2A253-100
SICU
PATIENT
ROOM 10
2A269A-100
BATHROOM,
PATIENT
2A241A-100
BATHROOM,
PATIENT
2A235A-100
BATHROOM,
PATIENT
2A237A-100
BATHROOM,
PATIENT
2A263A-100
BATHROOM,
PATIENT
2A267A-100
BATHROOM,
PATIENT
2A243A-100
BATHROOM,
PATIENT
2A253A-100
BATHROOM,
PATIENT
2A265A-100
BATHROOM,
PATIENT
2A233A-100
BATHROOM,
PATIENT
2A247A-100
BATHROOM,
PATIENT
2A259A-100
BATHROOM,
PATIENT2A249A-100
BATHROOM,
PATIENT
2A231A-100
BATHROOM,
PATIENT
2A257A-100
BATHROOM,
PATIENT
2A251A-100
BATHROOM,
PATIENT
2A243B-100
ANTEROOM
2A241B-100
ANTEROOM
2A238B-100
NURSE
WORKROOM
N2A-67-100
NURSE
SUB-STATION
N2A-63-100
NURSE
SUB-STATION
N2A-57-100
NURSE
SUB-STATION
N2A-51-100
NURSE
SUB-STATION
N2A-41-100
NURSE
SUB-STATION
N2A-47-100
NURSE
SUB-STATION
N2A-35-100
NURSE
SUB-STATION
N2A-31-100
NURSE
SUB-STATION
2A236-100
UTILITY
ROOM,
CLEAN,
LINEN
2A238C-100
CONFERENCE/
REPORT
ROOM
2A260-100
ELEC
2A226-100
EMPL
WELLNESS
2A286A-100
FS CART
STORAGE
2A258-100
SIGNAL
2A282-100
DISPOSAL
CHUTE
ROOM,
LINEN
2A239-100
MEDICATION
ROOM
2A234-100
NOURISHMENT
STATION
2A254-100
OI&T
2A280-100
STORAGE,
EQUIPMENT
2A264-100
TEAM
ROOM
2A284-100
DISPOSAL
CHUTE
ROOM,
TRASH
V2-04-100
SERVICE
ELEV
2A238D-100
CC
ALCOVE
2A238A-100
WARD
CLERK
2A262-100
LOCKER
ROOM
STAFF
2A238-100
NURSE
STATION,
ICU
2A227-100
CONSULTATION
ROOM
2A223-100
CONSULTATION
ROOM
2A224-100
TOILET,
STAFF
2A286B-100
WC
ALCOVE
2A289-100
STORAGE,
EMS 2A281-100
STORAGE,
EQUIPMENT
2A212D-100
TOILET,
PUBLIC
2A288-100
HAC
2A287-100
UTILITY,
SOILED
2A214-100
TEAM
ROOM
2A204B-100
OFFICE
2A212A-100
TOILET,
PUBLIC
2A212C-100
TOILET,
FAMILY
ASSIST
2A212B-100
TOILET,
FAMILY
ASSIST
2A225A-100
KIOSK,
PATIENT
EDUC/
RESRC 2A225-100
WAITING/
LOUNGE
C2-05-100
CORRIDOR
C2-04-100
CORRIDOR
C2-09-100
CORRIDOR
V2-01-100
PATIENT
ELEV
C2-07-100
CORRIDOR
C2-02-100
CORRIDOR
C2-10-100
CORRIDOR
2A282A-100
ALCOVE
C2-11-100
CORRIDOR
C2-08-100
CORRIDOR
C2-03-100
CORRIDOR
C2-23-100
CORRIDOR
S2-01-100
STAIR 1
LEVEL 2
2B203-100
CICU
PATIENT
ROOM 1
2B205-100
CICU
PATIENT
ROOM 2
2B203A-100
BATHROOM,
PATIENT
2B205A-100
BATHROOM,
PATIENT
N2B-03-100
NURSE
SUB-STATION
2A276A-100
MOBILE
X-RAY
ALCOVE
2A276-100
BLOOD
GAS LAB
2A272-100
LOUNGE,
STAFF
2A274-100
TOILET,
STAFF
2A204C-100
OFFICE
2A204D-100
OFFICE
2A208-100
CONFERENCE 2A204A-100
OFFICE
2B200-100
TOILET,
FAMILY
ASSIST
2B202-100
TOILET,
STAFF
V2-03-100
PUBLIC
ELEV
2B204-100
PATIENT
SHOWER
2B280-100
STORAGE,
EQUIPMENT
2B275-100
GREETER
2B272-100
OFFICE
2B270-100
OFFICE
2B271-100
CONSULTATION
ROOM
2B273-100
CONSULTATION
ROOM
2A207-100
VISITOR
KITCHENETTE
2A205-100
KIOSK,
PATIENT
EDUC/
RESRC
2B274-100
TOILET,
PUBLIC
2A206-100
KIOSK,
PATIENT
EDUC/
RESRC
2A203-100
WAITING/
LOUNGE
C2-12-100
CORRIDOR
C2-06-100
CORRIDOR
C2-19-100
CORRIDOR
C2-15-100
CORRIDOR
2A215-100
WAITING/
LOUNGE
C2-24-100
CORRIDOR
2B200A-100
ALCOVE
C2-01-100
CORRIDOR
FD
FD
SD
FSD
SD
D
360 A 480 D
360 A 480 D
20/18 LP VAV-02-26
480 D
175 D 135 A
170 D135 A
80 I
75 I
250 H 250 A
95 K
115 H
115 A250 H
115 A 250 H
250 A
250 H
115 H
85 K
140 A
75 I
205 D
135 A
195 D
75 I
75 I
135 A 175 D
75 I 140 A
180 D
365 D95 E
95 B
50 D
50 A
100 K
325 B
325 D
325 B
325 D
325 B
290 B 275 D
60 D
110 A
110 D
275 D
110 A
110 D
275 D
200 B
235 A
230 A
270 B
160 H
235 A
230 A
150 A
50 D
50 A 95 I420 D
100 D
225 A
115 I
65 D
65 A 55 D
65 A
65 D
55 A
75 D
155 A155 A
310 D
115 I
95 I
110 D
270 B
440 D
110 B 110 B
110 D
100 A
110 A
55 B
140 B
100 D 210 D 60 D 60 A
70 D
70 A
VAV-02-13
95 I
185 B185 B
65 B 210 D
70 A
70 D
205 D
265 A
190 D
285 A
185 D
100 K
100 I
100 I
140 A145 A
75 I75 I
260 A
115 B
230 J
115 B
195 A
100 I
175 D
330 A
240 H
140 A
360 D
115 A
115 A
240 B
370 O 12 x 10
370 N 12 x 10 115 A345 D
275 A
360 D
288 N 20 x 4
320 O 20 x 4
320 D
225 A
260 A
360 D
200 D 185 D 185 D
150 A
140 A
140 A
140 A
185 D 185 D
140 A
140 A
185 D 185 D
140 A 145 A
190 D
75 I75 I75 I75 I75 I75 I75 I75 I
215 D
SD
SD
FSD
75 A
/1
LP
/1
LP
/1
M
P
/1
M
P
/1
M P
30/26 MP
/1
M
P
/1
M
P
24/16 MP
/1
LP
FSD 24
/2
M
P
8/
L P
SD
/1
LP SD
/1
M
P
30/10 MP
/1
LP
12/8 LP
22/8 LP
38/34 LP40/30 LP
95 D
85 A
95 H
260 ASD
14/14 LP
VAV-02-21
285 O 12 x 8320 O
12 x 8285 O 12 x 8
320 O 12 x 8
320 O 20 x 4
288 N 20 x 4
280 A
70 A
95 A
70 D
95 D 225 A
400 A
20/18 LP
16/12 LP
44/34 LP 48/30 LP38/34 LP
20/6 LP
18/6 LP
/1
M
P
24/16 MP
/2
M
P
110 H
210 A10/10 LP
C2-30-100
CORRIDOR
12/14 LP
16/16 LP
275 A
T
VAV-02-19
85 A
SD
SD
SD
SD
SDSD
SD
SDSD
SD
SD
SD
SD
SD
SD
SD
SD
SD
FD
SD
FD
FD
FD
30/26 MP30/26 MP26/24 MP
/1
M
P
14/14 LP
T
T C
270 B
260 A
325 D
360 A
SD
360 H
SD
285 D
500 F
500 H
500 F
5 6
SD
6/8 LP
8/12 MP
/1
LP
12/14 LP
6/
L P
/1
LP
32/24 LP
/2
LP
22/20 LP 10/14 LP
10/12 LP
FSD
FSD
20/16 LP
12/10 LP
14/14 LP
26/20 LP 12/14 LP
6/12 LP
DT-14T
SD
50/26 LP 44/34 LP38/34 LP
44/34 LP
40/10 MP
"ø
/1
LP
/1
M
P
8/12 LP
/1
LP
15 15…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .