This document is an Addendum No. 2 dated September 5, 2025, for the Mattawan Consolidated School Maintenance & Transportation Services project located in Mattawan, Michigan. The addendum covers Bid Package 2 for a new maintenance and transportation facility, with changes and clarifications to the original bidding documents issued on August 8, 2025. The addendum includes modifications to various specification sections (08 4113, 08 5113, 08 9199, 33 1416) and multiple drawing sheets across architectural, structural, electrical, and site planning disciplines. Specific changes include updates to frame profiles, window specifications, louver details, flagpole height, and electrical connections for fuel station and equipment.
The addendum introduces modifications to technical specifications and drawing details that impact the project's design and construction, such as adjusting the aluminum frame profile for storefront systems to 2-inch by 6-inch, updating casement window specifications, adding fixed louver specifications, and revising electrical connections for fuel station pumps and equipment. The changes appear to refine the project's technical requirements, potentially addressing design details, performance specifications, and equipment configurations based on coordination meetings and design reviews. The document maintains the original project scope of creating a comprehensive maintenance and transportation services facility for Mattawan Consolidated School, with precise technical adjustments to ensure optimal functionality and performance of the building systems.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nurturing curiosity through design since 1953 • towerpinkster.com
©2025 Tower Pinkster Titus Associates, Inc.
ADDENDUM NO. 2
DATE OF ISSUANCE: September 5, 2025
PROJECT: MCS – Maintenance & Transportation Services
Western St.
Mattawan, MI 49071
OWNER: Mattawan Consolidated School
ARCHITECT’S PROJECT NO.: 23-106.020
ORIGINAL BID ISSUE DATE: August 8, 2025
SCOPE OF WORK
This Addendum includes changes to, or clarifications of, the original Bidding Documents and any previously issued addenda, and shall be included in the Bid. All of these Addendum items form a part of the Contract Documents. The Bidder shall acknowledge receipt of this Addendum in the appropriate space provided on the Bid Form. Failure to do so may result in disqualification of the Bid.
DOCUMENTS INCLUDED IN THIS ADDENDUM
This Addendum includes 5 pages of text and the following documents:
• Bidding Documents: None
• Contract Conditions: None
• Specification Sections: 08 4113, 08 5113, 08 9199, 33 1416
• Drawings: C 100, C 200, L101, L141, L201, SG 001, S 100, S 201, A 301, A 302, A 321, A 401, A 501, A
502, ES101, ES102, E101, E401, E402, E501
CHANGES TO PREVIOUSLY ISSUED ADDENDA
None.
CHANGES TO SPECIFICATIONS
ADD-1 Item No. S-1 - Spec 08 4113 (BRFI 68, 86)
Frame profile updated to 2-inch by 6-inch and the Basis of Design was updated to Kawneer North America, Trifab 601 UT.
ADD-1 Item No. S-2 - Spec 08 5113 (BRFI 66, 89)
Casement window specification added and service window (transaction windows) specifications updated.
9.5.2025 Addendum No. 2 // Mattawan CS Maintenance & Transportation Services // 23-106.020 2
ADD-1 Item No. S-3 - Spec 08 9119 and updated table of contents
Fixed Louver Specification section added and Table of Contents updated
ADD-1 Item No. S-4 - 10 7516
Refer to Section(s): 107516
- Change 35’ tall flagpole to 30’ flagpole
ADD-1 Item No. S-5 - Spec 33 1416
Refer to Section(s): 331416
- Added reference to other spec sections this project.
- Specifically called out references to Village of Mattawan spec sections.
ADD-1 Item No. S-6 - 10 7516
Refer to Section(s): 107516
- Change 35’ tall flagpole to 30’ flagpole
CHANGES TO DRAWINGS
ADD-1 Item No. D-1 - Plan
Refer to Sheet(s): C 100, L101
Added more curb end taper labels to sheet
ADD-1 Item No. D-2 - Plan
Refer to Sheet(s): C 100, C 200, L101
Updated fuel station linework and grading per coordination call 8/27/2025.
ADD-1 Item No. D-3 - Plan
Refer to Sheet(s): C 200
- Adjusted grading at western ADA parking.
- Adjusted grading of north parking lot.
- Lengthened tapers for 2” drop near doors from 5’ to 8.5’.
- Updated sidewalk grades at peninsula and bus parking island to reduce cross slopes.
9.5.2025 Addendum No. 2 // Mattawan CS Maintenance & Transportation Services // 23-106.020 3
ADD-1 Item No. D-4 - Additional landscape plan dimensions and notes
Refer to Sheet(s): L101
Added dimensions for bollard spacing, keypad location, and striping.
Additional note to align 20’ sliding gate with spill ways.
Label Flagpole and revise keynote to state height of flagpole.
Label Wheel Stops.
ADD-1 Item No. D-5 - Fuel Station
Refer to Sheet(s): L 101
Revisions to fuel station pumps and tanks layouts and keynotes.
Additional bollards at 5’-0” O.C. surrounding entire fuel station.
ADD-1 Item No. D-6 - Maintenance strip updated
Refer to Sheet(s): L101, L141
Delineate on plan between maintenance strip below finished floor elevation and below finished floor elevation.
Revision to maintenance strip detail by increasing dowel spacing to 24” O.C.
Provide maintenance strip detail at finish floor elevation.
ADD-1 Item No. D-7 - Temporary Salt Storage
Revision to note 1 to include “Manufacture Standard Colors”
ADD-1 Item No. D-8 - Updated plant list and landscape plan
Refer to Sheet(s): L201
Added perennial spacing in plant list schedule.
Added No Mow Seed Mix description in plant list schedule.
Added Landscape Edging
ADD-1 Item No. D-9 - Structural engineering added for new canopy at condensing units
Refer to Sheet(s): SG 001, S 100
ADD-1 Item No. D-10 - For alternate bus canopy: pier & footing added
Refer to Sheet(s): S 201
9.5.2025 Addendum No. 2 // Mattawan CS Maintenance & Transportation Services // 23-106.020 4
ADD-1 Item No. D-11 - A 301 (BRFI 038)
Added exterior signage dimensions.
Edited operable casement location.
ADD-1 Item No. D-12 - A 302 (BRFI 038, BRFI 040)
Added exterior signage dimensions.
Added enlarged signage detail.
Louver details added.
Edited operable casement location.
ADD-1 Item No. D-13 - A 321 (BRFI 022)
Edited detail title to include transaction window.
Added text note for loading dock stair referring to tooled in grooves.
ADD-1 Item No. D-14 - A 401 (BRFI 043)
Edit counter lavatory detail to show solid surface countertops and updated backsplash.
Edit tag on combination paper towel & waste basket to the 15 in the Men’s and Women’s Locker Rooms.
ADD-1 Item No. D-15 - A 501 (BRFI 050, 048, 046, 045)
Added counter door jamb detail.
Added OHCC elevation and added “refer to schedule” note to OHC frame elevation.
Edit frame elevations, door type, head and jamb, and glass designation on door schedule
ADD-1 Item No. D-16 - A 502 (BRFI 067, 090)
Added text note referring to what windows have operable casement.
Removed operable markings on SF1 & SF2.
Added glass designation to SF5.
Added arrow showing direction of transaction window opening.
ADD-1 Item No. D-17 - Revise Fueling Station Electrical Connections
Refer to Drawings ES101, ES102, E101, E402, and E501
Revised electrical connections to fueling station based on coordination meeting with J&H oil.
9.5.2025 Addendum No. 2 // Mattawan CS Maintenance & Transportation Services // 23-106.020 5
Removed (2) 208/1 pumps. Added (3) 120V pumps.
Removed (1) control circuit, (1) remains.
Removed (1) data conduit to MDF, (1) remains.
Revised location of e-stop and alarms form building mounted to light pole mounted. E-stop and alarms must be in the range of 20-100’ from the pumps.
ADD-1 Item No. D-18 - Revised Air Compressor
Refer to Drawings, E101, E402, and E501
Revised electrical connections to air compressor from 208/3 to 480/3. Revised drawings, feeder schedule, and panelboard schedules.
ADD-1 Item No. D-19 - Revise Panel D1E
Refer to Drawings E401 and E501.
Revised panel D1E to 60 pole in lieu of 42 pole.
Added panel D1E to one-line diagram.
END OF ADDENDUM.
PROJECT NO. 23-106.020
TABLE OF CONTENTS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES
MATTAWAN CONSOLIDATED SCHOOL SEPTEMBER 4, 2025
ADDENDUM 2
[Copyright] 2025 Tower Pinkster Titus Associates - All Rights Reserved
TABLE OF CONTENTS
Refer to Construction Manager’s Project Manual issued by Construction Manager for additional procurement, contracting, and general requirements
DIVISION 00 — PROCUREMENT AND CONTRACTING REQUIREMENTS
00 2600 - PROCUREMENT SUBSTITUTION PROCEDURES
00 3100 - AVAILABLE PROJECT INFORMATION
00 3110 - GEOTECHNICAL REPORT
00 4325 - SUBSTITUTION DURING PROCUREMENT REQUEST FORM
00 6324 - BIM TRANSFER WAIVER
00 6325 - SUBSTITUTION DURING CONSTRUCTION REQUEST FORM
00 7200 - GENERAL CONDITIONS
DIVISION 01 — GENERAL REQUIREMENTS
01 2300 - ALTERNATES
01 2500 - SUBSTITUTION PROCEDURES
01 2600 - CONTRACT MODIFICATION PROCEDURES
01 3100 - PROJECT MANAGEMENT AND COORDINATION
01 3300 - SUBMITTAL PROCEDURES
01 4000 - QUALITY REQUIREMENTS
01 4200 - REFERENCES
01 6000 - PRODUCT REQUIREMENTS
01 7300 - EXECUTION
01 7700 - CLOSEOUT PROCEDURES
01 7823 - OPERATION AND MAINTENANCE DATA
01 7839 - PROJECT RECORD DOCUMENTS
01 7900 - DEMONSTRATION AND TRAINING
01 9113 - GENERAL COMMISSIONING REQUIREMENTS
DIVISION 03 — CONCRETE
03 3000 - CAST-IN-PLACE CONCRETE
DIVISION 04 — MASONRY
04 2000 - UNIT MASONRY
DIVISION 05 — METALS
05 5000 - METAL FABRICATIONS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES
DIVISION 06 — WOOD, PLASTICS, AND COMPOSITES
06 1000 - ROUGH CARPENTRY
06 1600 - SHEATHING
06 4116 - PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS
DIVISION 07 — THERMAL AND MOISTURE PROTECTION
07 1900 - WATER REPELLENTS
07 2100 - THERMAL INSULATION
07 2119 - FOAMED-IN-PLACE INSULATION
07 2500 - WEATHER BARRIERS
07 7253 - SNOW GUARDS
07 8413 - PENETRATION FIRESTOPPING
07 8443 - JOINT FIRESTOPPING
07 9200 - JOINT SEALANTS
07 9219 - ACOUSTICAL JOINT SEALANTS
DIVISION 08 — OPENINGS
08 1113 - HOLLOW METAL DOORS AND FRAMES
08 1243 - FIRE-RESISTANCE-RATED FRAMES
08 1416 - FLUSH WOOD DOORS
08 3313 - COILING COUNTER DOORS
08 3323 - OVERHEAD COILING DOORS
08 3613 - SECTIONAL DOORS
08 4113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 5113 - ALUMINUM WINDOWS
08 7100 - DOOR HARDWARE
08 7101 - DOOR HARDWARE SETS
08 7102 - DOOR HARDWARE INDEX
08 7103 - MCS DOOR HARDWARE
08 8000 - GLAZING
08 8813 - FIRE-RATED GLAZING
08 9119 - FIXED LOUVERS
DIVISION 09 — FINISHES
09 2216 - NON-STRUCTURAL METAL FRAMING
09 2900 - GYPSUM BOARD
09 5113 - ACOUSTICAL PANEL CEILINGS
09 6513 - RESILIENT BASE AND ACCESSORIES
09 6723 - RESINOUS FLOORING
09 6813 - TILE CARPETING
09 9123 - INTERIOR PAINTING
09 9600 - HIGH-PERFORMANCE COATINGS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES
DIVISION 10 — SPECIALTIES
10 1100 - VISUAL DISPLAY UNITS sf1
10 1453 - TRAFFIC SIGNAGE
10 2113.19 - PLASTIC TOILET COMPARTMENTS
10 2600 - WALL AND DOOR PROTECTION
10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES
10 4313 - DEFIBRILLATOR CABINETS
10 4413 - FIRE PROTECTION CABINETS
10 4416 - FIRE EXTINGUISHERS
10 5126 - PLASTIC LOCKERS
10 5330 - DELEGATED DESIGN CANOPY
10 7516 - GROUND-SET FLAGPOLES
DIVISION 11 — EQUIPMENT
11 1126 - VEHICLE WASHING EQUIPMENT
11 1313 - LOADING DOCK BUMPERS
DIVISION 12 — FURNISHINGS
12 2413 - ROLLER WINDOW SHADES
12 3661.16 - SOLID SURFACING COUNTERTOPS
This page intentionally left blank.
PROJECT NO. 23-106.020 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 1
SECTION 08 4113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Aluminum-framed storefront systems.
2. Aluminum-framed entrance door systems.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: For aluminum-framed entrances and storefronts. Include plans, elevations, sections, full-size details, and attachments to other work.
1. Show connection to and continuity with adjacent thermal, weather, air, and vapor barriers.
C. Samples for Initial Selection: For units with factory-applied color finishes.
D. Samples for Verification: For each type of exposed finish required, in manufacturer's standard sizes.
E. Delegated-Design Submittal: For aluminum-framed entrances and storefronts including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
1.3 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer.
B. Energy Performance Certificates: NFRC-certified energy performance values from manufacturer.
C. Sample warranties.
1.4 CLOSEOUT SUBMITTALS
A. Maintenance data.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.
B. Product Options: Information on Drawings and in Specifications establishes requirements for aesthetic effects and performance characteristics of assemblies. Aesthetic effects are indicated by dimensions, MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 2 arrangements, alignment, and profiles of components and assemblies as they relate to sightlines, to one another, and to adjoining construction.
1. Do not change intended aesthetic effects, as judged solely by Architect, except with Architect's approval. If changes are proposed, submit comprehensive explanatory data to Architect for review.
1.6 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of aluminum-framed entrances and storefronts that do not comply with requirements or that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures, including, but not limited to, excessive deflection.
b. Noise or vibration created by wind and thermal and structural movements.
c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.
d. Water penetration through fixed glazing and framing areas.
e. Failure of operating components.
2. Warranty Period: Two years from date of Substantial Completion.
B. Special Finish Warranty, Factory-Applied Finishes: Standard form in which manufacturer agrees to repair finishes or replace aluminum that shows evidence of deterioration of factory-applied finishes within specified warranty period.
1. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations for Aluminum-Framed Systems: Obtain from single source from single manufacturer.
1. Obtain aluminum doors and frames through a single source. Verify that doors and frames will operate and seal properly with specified hardware.
2.2 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer, as defined in Section 01 4000 "Quality Requirements," to design aluminum-framed entrances and storefronts.
B. General Performance: Comply with performance requirements specified, as determined by testing of aluminum-framed entrances and storefronts representing those indicated for this Project without failure due to defective manufacture, fabrication, installation, or other defects in construction.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 3
1. Aluminum-framed entrances and storefronts shall withstand movements of supporting structure, including, but not limited to, twist, column shortening, long-term creep, and deflection from uniformly distributed and concentrated live loads.
2. Failure also includes the following:
a. Thermal stresses transferring to building structure.
b. Glass breakage.
c. Noise or vibration created by wind and thermal and structural movements.
d. Loosening or weakening of fasteners, attachments, and other components.
e. Failure of operating units.
C. Structural Loads:
1. Wind Loads: As indicated on Drawings.
D. Deflection of Framing Members Supporting Glass: At design wind load, as follows:
1. Deflection Normal to Wall Plane: Limited to 1/175 of clear span for spans of up to 13 feet 6 inches and to 1/240 of clear span plus 1/4 inch for spans greater than 13 feet 6 inches.
2. Deflection Parallel to Glazing Plane: Limited to amount not exceeding that which reduces glazing bite to less than 75 percent of design dimension and that which reduces edge clearance between framing members and glazing or other fixed components to less than 1/8 inch.
a. Operable Units: Provide a minimum 1/16-inch clearance between framing members and operable units.
3. Cantilever Deflection: Limited to 2l/175 at unsupported cantilevers.
E. Structural: Test according to ASTM E 330/E 330M as follows:
1. When tested at positive and negative wind-load design pressures, storefront assemblies, including entrance doors, do not evidence deflection exceeding specified limits.
2. When tested at 150 percent of positive and negative wind-load design pressures, storefront assemblies, including entrance doors and anchorage, do not evidence material failures, structural distress, or permanent deformation of main framing members exceeding 0.2 percent of span.
3. Test Durations: As required by design wind velocity, but not less than 10 seconds.
F. Water Penetration under Static Pressure: Test according to ASTM E 331 as follows:
1. No evidence of water penetration through fixed glazing and framing areas, including entrance doors, when tested according to a minimum static-air-pressure differential of 20 percent of positive wind-load design pressure, but not less than 10 lbf/sq. ft..
G. Energy Performance: Certified and labeled by manufacturer for energy performance as follows:
1. Thermal Transmittance (U-factor):
a. Fixed Glazing and Framing Areas: U-factor for the system of not more than 0.35 Btu/sq. ft.
x h x deg F as determined according to NFRC 100.
2. Solar Heat Gain Coefficient (SHGC): Fixed glazing and framing areas as a system shall have SHGC of no greater than 0.35 as determined according to NFRC 200.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 4
3. Air Leakage:
a. Fixed Glazing and Framing Areas: Air leakage for the system of not more than 0.06 cfm/sq.
ft. at a static-air-pressure differential of 6.24 lbf/sq. ft. when tested according to ASTM E283.
b. Entrance Doors: Air leakage of not more than 1.0 cfm/sq. ft. at a static-air-pressure differential of 1.57 lbf/sq. ft..
4. Condensation Resistance Factor (CRF):
a. Fixed Glazing and Framing Areas: CRF for the system of not less than 62 as determined according to AAMA 1503.
H. Thermal Movements: Allow for thermal movements resulting from ambient and surface temperature changes.
1. Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.
2.3 STOREFRONT SYSTEMS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. EFCO Corporation.
2. Kawneer North America.
3. Oldcastle BuildingEnvelope.
4. Special-Lite, Incorporated.
5. Tubelite.
6. Wausau Metals.
7. YKK AP America Inc.
B. Framing Members: Manufacturer's extruded- or formed-aluminum framing members of thickness required and reinforced as required to support imposed loads.
1. Basis-of-Design Product: Kawneer North America; Trifab 601 UT.
2. Frame Profile: 2 inches wide by 6 inches deep.
3. Exterior Framing Construction: Thermally broken.
4. Interior Vestibule Framing Construction: Nonthermal.
5. Glazing System: Retained mechanically with gaskets on four sides.
6. Glazing Plane: Center.
7. Finish: Color anodic finish.
8. Fabrication Method: Field-fabricated stick system.
9. Aluminum: Alloy and temper recommended by manufacturer for type of use and finish indicated.
10. Steel Reinforcement: As required by manufacturer.
C. Backer Plates: Manufacturer's standard, continuous backer plates for framing members, if not integral, where framing abuts adjacent construction.
D. Brackets and Reinforcements: Manufacturer's standard high-strength aluminum with nonstaining, nonferrous shims for aligning system components.
http://www.specagent.com/LookUp/?uid=123456853016&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456853025&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456853048&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456853020&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456853024&mf=04&src=wd
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 5
2.4 ENTRANCE DOOR SYSTEMS
A. Stile-and-Rail Entrance Doors: Manufacturer's standard glazed entrance doors for manual-swing or automatic operation.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. Cross Aluminum Products, Inc.
b. EFCO Corporation.
c. Oldcastle Building Envelope.
d. Tubelite Inc.
e. United States Aluminum.
f. YKK AP America Inc.
2. Door Construction: 1-3/4-inch overall thickness, with minimum 0.125-inch-thick, extruded-aluminum tubular rail and stile members. Mechanically fasten corners with reinforcing brackets that are deeply penetrated and fillet welded or that incorporate concealed tie rods.
a. Thermal Construction: High-performance plastic connectors separate aluminum members exposed to the exterior from members exposed to the interior.
b. Thermal Transmittance (U-factor): Not more than 0.65 Btu/sq. ft. x h x deg F as determined according to NFRC 102.
c. Condensation Resistance: Condensation rating of not less than 46 as determined according to AAMA 1503.
3. Door Design: As indicated.
4. Glazing Stops and Gaskets: Square, snap-on, extruded-aluminum stops and preformed gaskets.
a. Provide nonremovable glazing stops on outside of door.
B. Aluminum Skin Doors (ALSN): Aluminum skins rabbeted into extruded aluminum frames with a poured-in-place insulation core as follows:
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. Capitol Aluminum and Glass.
b. Cline Aluminum Doors Inc.
c. CMI Architectural Products, Inc.
d. Commercial Door Systems.
e. Special-Lite, Incorporated.
f. United States Aluminum.
2. Frames: Extruded 6063-T5 aluminum alloy rails and stiles, 1-3/4 inches deep and minimum 2-5/16 inches wide, with 0.125-inch) thick walls. Construct with mitered corners and provide joinery of 3/8-inch diameter full width tie rods through extruded splines top and bottom. Reinforce to accept hardware as specified. Provide hex type aircraft nuts for joinery without welds, glues or other methods for securing internal door extrusions. Furnish integral reglets to accept face sheet to permit a flush appearance. Rail caps or other face sheet capture methods are not acceptable.
Extrude top and bottom rail legs for interlocking continuous rail rigidity weather bar. Lock face sheet material in place with extruded interlocking edges to be flush with aluminum rails and stiles.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 6
3. Aluminum Facing Sheets: 0.062-inch-thick aluminum sheet with smooth surface and manufacturer’s backing sheet.
4. Core of Door Assembly: Minimum 5 lb/cu. ft. density poured-in-place polyurethane free of CFC.
Minimum "R" value of 11. Meeting stiles on pairs of doors and bottom weather bars with nylon brush weatherstripping.
5. Manufacture doors with cutouts for vision lites, louvers or panels as indicated. Factory furnish and install all glass, louvers and panels prior to shipment.
6. Pre-machine doors in accordance with templates from the specified hardware manufacturers and approved hardware schedule.
2.5 ENTRANCE DOOR HARDWARE
A. Entrance Door Hardware: Hardware not specified in this Section is specified in Section 08 7100 "Door Hardware."
B. Strikes: Provide strike with black-plastic dust box for each latch or lock bolt; fabricated for aluminum framing.
C. Weather Stripping: Manufacturer's standard replaceable components.
1. Compression Type: Made of ASTM D 2000 molded neoprene or ASTM D 2287 molded PVC.
2. Sliding Type: AAMA 701/702, made of wool, polypropylene, or nylon woven pile with nylon-fabric or aluminum-strip backing.
D. Weather Sweeps: Manufacturer's standard exterior-door bottom sweep with concealed fasteners on mounting strip.
E. Thresholds: BHMA A156.21 raised thresholds beveled with a slope of not more than 1:2, with maximum height of 1/2 inch.
1. Threshold material: Mattawan Consolidated School standard composite material used by the District.
2.6 GLAZING
A. Glazing: Comply with Section 08 8000 "Glazing."
B. Glazing Gaskets: Manufacturer's standard sealed-corner pressure-glazing system of black, resilient elastomeric glazing gaskets, setting blocks, and shims or spacers.
2.7 MATERIALS
A. Sheet and Plate: ASTM B 209.
B. Extruded Bars, Rods, Profiles, and Tubes: ASTM B 221.
C. Extruded Structural Pipe and Tubes: ASTM B 429/B 429M.
D. Structural Profiles: ASTM B 308/B 308M.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 7
E. Steel Reinforcement:
1. Structural Shapes, Plates, and Bars: ASTM A 36/A 36M.
2. Cold-Rolled Sheet and Strip: ASTM A 1008/A 1008M.
3. Hot-Rolled Sheet and Strip: ASTM A 1011/A 1011M.
4. Primer: Manufacturer's standard zinc-rich, corrosion-resistant primer complying with SSPC-
PS Guide No. 12.00; applied immediately after surface preparation and pretreatment. Select surface preparation methods according to recommendations in SSPC-SP COM, and prepare surfaces according to applicable SSPC standard.
2.8 ACCESSORIES
A. Fasteners and Accessories: Manufacturer's standard corrosion-resistant, nonstaining, nonbleeding fasteners and accessories compatible with adjacent materials.
1. Use self-locking devices where fasteners are subject to loosening or turning out from thermal and structural movements, wind loads, or vibration.
2. Reinforce members as required to receive fastener threads.
B. Bituminous Paint: Cold-applied asphalt-mastic paint containing no asbestos, formulated for 30-mil thickness per coat.
2.9 FABRICATION
A. Form or extrude aluminum shapes before finishing.
B. Weld in concealed locations to greatest extent possible to minimize distortion or discoloration of finish.
Remove weld spatter and welding oxides from exposed surfaces by descaling or grinding.
C. Fabricate components that, when assembled, have the following characteristics:
1. Profiles that are sharp, straight, and free of defects or deformations.
2. Accurately fitted joints with ends coped or mitered.
3. Physical and thermal isolation of glazing from framing members.
4. Accommodations for thermal and mechanical movements of glazing and framing to maintain required glazing edge clearances.
5. Provisions for field replacement of glazing from exterior.
6. Fasteners, anchors, and connection devices that are concealed from view to greatest extent possible.
D. Mechanically Glazed Framing Members: Fabricate for flush glazing without projecting stops.
E. Entrance Door Frames: Reinforce as required to support loads imposed by door operation and for installing entrance door hardware.
1. Door Stops: Screw-applied or snap-in box type with minimum 3/4-inch depth.
2. At interior and exterior doors, provide compression weather stripping at fixed stops.
F. Entrance Doors: Reinforce doors as required for installing entrance door hardware.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 8
1. At pairs of exterior doors, provide sliding-type weather stripping retained in adjustable strip and mortised into door edge.
2. At exterior doors, provide weather sweeps applied to door bottoms.
G. Entrance Door Hardware Installation: Factory install entrance door hardware to the greatest extent possible. Cut, drill, and tap for factory-installed entrance door hardware before applying finishes.
H. After fabrication, clearly mark components to identify their locations in Project according to Shop Drawings.
2.10 ALUMINUM FINISHES
A. Color Anodic Finish: AAMA 611, AA-M12C22A42/A44, Class I, 0.018 mm or thicker.
1. Color: As selected by Architect from full range of industry colors and color densities.
PART 3 - EXECUTION
3.1 INSTALLATION
A. General:
1. Comply with manufacturer's written instructions.
2. Do not install damaged components.
3. Fit joints to produce hairline joints free of burrs and distortion.
4. Rigidly secure nonmovement joints.
5. Install anchors with separators and isolators to prevent metal corrosion and electrolytic deterioration and to prevent impeding movement of moving joints.
6. Seal perimeter and other joints watertight unless otherwise indicated.
B. Metal Protection:
1. Where aluminum is in contact with dissimilar metals, protect against galvanic action by painting contact surfaces with materials recommended by manufacturer for this purpose or by installing nonconductive spacers.
2. Where aluminum is in contact with concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint.
C. Set continuous sill members and flashing in full sealant bed, as specified in Section 07 9200 "Joint Sealants," to produce weathertight installation.
D. Install components plumb and true in alignment with established lines and grades.
E. Install operable units level and plumb, securely anchored, and without distortion. Adjust weather-stripping contact and hardware movement to produce proper operation.
F. Install glazing as specified in Section 08 8000 "Glazing."
G. Entrance Doors: Install doors to produce smooth operation and tight fit at contact points.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 4113 - 9
1. Exterior Doors: Install to produce weathertight enclosure and tight fit at weather stripping.
2. Field-Installed Entrance Door Hardware: Install surface-mounted entrance door hardware according to entrance door hardware manufacturers' written instructions using concealed fasteners to greatest extent possible.
H. Erection Tolerances: Install aluminum-framed entrances and storefronts to comply with the following maximum tolerances:
1. Plumb: 1/8 inch in 10 feet; 1/4 inch in 40 feet.
2. Level: 1/8 inch in 20 feet; 1/4 inch in 40 feet.
3. Alignment:
a. Where surfaces abut in line or are separated by reveal or protruding element up to 1/2 inch wide, limit offset from true alignment to 1/16 inch.
b. Where surfaces are separated by reveal or protruding element from 1/2 to 1 inch wide, limit offset from true alignment to 1/8 inch.
c. Where surfaces are separated by reveal or protruding element of 1 inch wide or more, limit offset from true alignment to 1/4 inch.
4. Location: Limit variation from plane to 1/8 inch in 12 feet; 1/2 inch over total length.
3.2 FIELD QUALITY CONTROL
A. Testing Agency: Owner will engage a qualified testing agency to perform tests and inspections.
B. Field Quality-Control Testing: Perform the following test on representative areas of aluminum-framed entrances and storefronts.
1. Water-Spray Test: Before installation of interior finishes has begun, areas designated by Architect shall be tested according to AAMA 501.2 and shall not evidence water penetration.
a. Perform a minimum of two tests in areas as directed by Architect.
C. Aluminum-framed entrances and storefronts will be considered defective if they do not pass tests and inspections.
D. Prepare test and inspection reports.
END OF SECTION 08 4113
PROJECT NO. 23-106.020 ALUMINUM WINDOWS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 5113 - 1
MATTAWAN CONSOLIDATED SCHOOL SEPTEMBER 4SEPTEMBER 4, 2025
SECTION 08 5113 - ALUMINUM WINDOWS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes aluminum service windows.
B. Section includes aluminum windows for exterior locations.
C. Related Requirements:
1. Section 08 4113 "Aluminum-Framed Entrances and Storefronts" for coordinating finish among aluminum fenestration units.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Include plans, elevations, sections, hardware, accessories, insect screens, operational clearances, and details of installation, including anchor, flashing, and sealant installation.
C. Samples for Initial Selection: For units with factory-applied finishes.
1. Include Samples of hardware and accessories involving color selection.
D. Samples for Verification: For aluminum windows and components required, showing full range of color variations for finishes, and prepared on Samples of size indicated below:
1. Exposed Finishes: 2 by 4 inches.
2. Exposed Hardware: Full-size units.
E. Product Schedule: For aluminum windows. Use same designations indicated on Drawings.
1.3 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer.
B. Sample warranties.
1.4 WARRANTY
A. Manufacturer's Warranty: Manufacturer agrees to repair or replace aluminum windows that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 5113 - 2
a. Failure to meet performance requirements.
b. Structural failures including excessive deflection, water leakage, condensation, and air infiltration.
c. Faulty operation of movable sash and hardware.
d. Deterioration of materials and finishes beyond normal weathering.
e. Failure of insulating glass.
2. Warranty Period:
a. Window: 2 years from date of Substantial Completion.
b. Glazing Units: 10 years from date of Substantial Completion.
c. Aluminum Finish: 10 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 ALUMINUM SERVICE WINDOWS
1. Service Window 102A Basis of Design: C.R.L. Horizontal Sliding Service Window, Half Track, without screen. Provide basis of design product or equivalent (to be approved by Architect).
a. Finish to be selected by architect from manufacturer’s standard line.
b. No bottom track. Suitable for use with solid surface countertop.
2.2 WINDOW PERFORMANCE REQUIREMENTS FOR EXTERIOR LOCATIONS
A. Product Standard: Comply with AAMA/WDMA/CSA 101/I.S.2/A440 for definitions and minimum standards of performance, materials, components, accessories, and fabrication unless more stringent requirements are indicated.
1. Window Certification: AAMA certified with label attached to each window.
B. Thermal Movements: Provide aluminum windows, including anchorage, that allow for thermal movements resulting from the following maximum change (range) in ambient and surface temperatures by preventing buckling, opening of joints, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss.
1. Temperature Change: 120 deg F ambient; 180 deg F material surfaces.
2.3 ALUMINUM WINDOWS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. EFCO Corporation.
2. Kawneer North America; an Alcoa company.
3. Peerless Products Inc.
4. YKK AP America Inc.
B. Window Type: Casementand related fixed windows:
http://www.specagent.com/Lookup?ulid=48 http://www.specagent.com/Lookup?uid=123457018400 http://www.specagent.com/Lookup?uid=123457018398 http://www.specagent.com/Lookup?uid=123457018405 http://www.specagent.com/Lookup?uid=123457018409
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 5113 - 3
1. Basis-of-Design Product: Kawneer North America; TriFab 601UT.
2. Frame Profile: 2 inches wide by 6 inches deep.
3. Exterior Framing Construction: Thermally broken.
4. Glazing System: Retained mechanically with gaskets on four sides.
5. Glazing Plane: Center.
6. Finish: Color Anodic finish.
7. Aluminum: alloy and temper recommended by manufacturer for type of use and finish indicated.
8. Steel Reinforcement: As required by manufacturer.
9. Thermal Transmittance: NFRC 100 maximum whole-window U-factor of [0.35 Btu/sq. ft. x h x deg F.
10. Solar Heat-Gain Coefficient (SHGC): NFRC 200 maximum whole-window SHGC of 0.35.
11. Air Leakage:
a. Fixed Glazing and Framing Areas: Air leakage for the system of not more than 0.06 cfm/sq.
ft. at a static-air-pressure differential of 6.24 lbf/sq. ft. when tested according to ASTM E283.
12. Condensation-Resistance Factor (CRF): Provide aluminum windows tested for thermal performance according to AAMA 1503, showing a CRF of not less than 62.
13. Frames and Sashes: Aluminum extrusions complying with AAMA/WDMA/CSA 101/I.S.2/A440.
a. Thermally Improved Construction: Fabricate frames, sashes, and muntins with an integral, concealed, low-conductance thermal barrier located between exterior materials and window members exposed on interior side in a manner that eliminates direct metal-to-metal contact.
14. Glass: Type as specified in Section 08 8000 "Glazing."
15. Glazing System: Manufacturer's standard factory-glazing system that produces weathertight seal.
C. Hardware, General: Provide manufacturer's standard hardware fabricated from aluminum, stainless steel, carbon steel complying with AAMA 907, or other corrosion-resistant material compatible with adjacent materials; designed to smoothly operate, tightly close, and securely lock windows, and sized to accommodate sash weight and dimensions.
1. Exposed Hardware Color and Finish: As selected by Architect from manufacturer's full range.
D. Projected Window Hardware:
1. Gear-Type Rotary Operators: Complying with AAMA 901 when tested according to ASTM E 405, Method A. Provide operators that function without requiring the removal of interior screens or using screen wickets.
2. Hinges: Non-friction type, not less than two per sash.
3. Lock: Concealed multipoint lock operated by single lever handle or lift-type throw.
E. Weather Stripping: Provide full-perimeter weather stripping for each operable sash unless otherwise indicated.
F. Fasteners: Noncorrosive and compatible with window members, trim, hardware, anchors, and other components.
1. Exposed Fasteners: Do not use exposed fasteners to greatest extent possible. For application of hardware, use fasteners that match finish hardware being fastened.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 5113 - 4
2.4 ACCESSORIES
A. Receptor System: Two-piece, snap-together, thermally broken, extruded-aluminum receptor system that anchors windows in place.
2.5 INSECT SCREENS
A. General: Fabricate insect screens to integrate with window frame. Provide screen for each operable exterior sash. Screen wickets are not permitted.
1. Type and Location: Full, inside for project-out sashes.
B. Aluminum Frames: Complying with SMA 1004 or SMA 1201.
C. Glass-Fiber Mesh Fabric: 18-by-14 or 18-by-16mesh of PVC-coated, glass-fiber threads; woven and fused to form a fabric mesh resistant to corrosion, shrinkage, stretch, impact damage, and weather deterioration. Comply with ASTM D 3656/D 3656M.
1. Mesh Color: Architect to select from manufacturers standard colors.
2.6 FABRICATION
A. Fabricate aluminum windows in sizes indicated. Include a complete system for assembling components and anchoring windows.
B. Weather strip each operable sash to provide weathertight installation.
C. Weep Holes: Provide weep holes and internal passages to conduct infiltrating water to exterior.
D. Provide water-shed members above side-hinged sashes and similar lines of natural water penetration.
2.7 ALUMINUM FINISHES
A. Finish designations prefixed by AA comply with the system established by the Aluminum Association for designating aluminum finishes.
B. Class I, Color Anodic Finish: AA-M12C22A42/A44 (Mechanical Finish: nonspecular as fabricated;
Chemical Finish: etched, medium matte; Anodic Coating: Architectural Class I, integrally colored or electrolytically deposited color coating 0.018 mm or thicker) complying with AAMA 611.
1. Color: As selected by Architect from full range of industry colors and color densities.
mesh
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 5113 - 5
PART 3 - EXECUTION
3.1 INSTALLATION
A. Comply with manufacturer's written instructions for installing windows, hardware, accessories, and other components. For installation procedures and requirements not addressed in manufacturer's written instructions, comply with installation requirements in ASTM E 2112.
B. Install windows level, plumb, square, true to line, without distortion or impeding thermal movement, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction to produce weathertight construction.
C. Install windows and components to drain condensation, water penetrating joints, and moisture migrating within windows to the exterior.
D. Separate aluminum and other corrodible surfaces from sources of corrosion or electrolytic action at points of contact with other materials.
3.2 ADJUSTING, CLEANING, AND PROTECTION
A. Adjust operating sashes and hardware for a tight fit at contact points and weather stripping for smooth operation and weathertight closure.
B. Clean exposed surfaces immediately after installing windows. Avoid damaging protective coatings and finishes. Remove excess sealants, glazing materials, dirt, and other substances.
C. Remove and replace glass that has been broken, chipped, cracked, abraded, or damaged during construction period.
END OF SECTION 08 5113
PROJECT NO. 23-106.020 FIXED LOUVERS
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 9119 - 1
SECTION 08 9119 - FIXED LOUVERS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Fixed extruded-aluminum louvers.
B. Related Requirements:
1. Section 08 1113 "Hollow Metal Doors and Frames" for louvers in hollow-metal doors.
2. Section 08 1416 "Flush Wood Doors" for louvers in flush wood doors.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. For louvers specified to bear AMCA seal, include printed catalog pages showing specified models with appropriate AMCA Certified Ratings Seals.
B. Shop Drawings: For louvers and accessories. Include plans, elevations, sections, details, and attachments to other work. Show frame profiles and blade profiles, angles, and spacing.
1. Show weep paths, gaskets, flashings, sealants, and other means of preventing water intrusion.
2. Show mullion profiles and locations.
C. Samples for Verification: For each type of metal finish required.
1.3 QUALITY ASSURANCE
A. Welding Qualifications: Qualify procedures and personnel according to the following:
1. AWS D1.2/D1.2M.
1.4 FIELD CONDITIONS
A. Field Measurements: Verify actual dimensions of openings by field measurements before fabrication.
1.5 WARRANTY
A. Special Finish Warranty: Manufacturer agrees to repair or replace components on which finishes fail in materials or workmanship within specified warranty period.
1. Warranty Period: 20 years from date of Substantial Completion.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 9119 - 2
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Louver Performance Ratings: Provide louvers complying with requirements specified, as demonstrated by testing manufacturer's stock units identical to those provided, except for length and width according to
AMCA 500-L.
B. Louver Performance Ratings: Provide louvers complying with requirements specified, as demonstrated by testing manufacturer's stock units identical to those provided, except for length and width according to
AMCA 500-L.
C. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes.
1. Temperature Change (Range): 120 deg F, ambient; 180 deg F, material surfaces.
D. SMACNA Standard: Comply with recommendations in SMACNA's "Architectural Sheet Metal Manual" for fabrication, construction details, and installation procedures.
2.2 FIXED EXTRUDED-ALUMINUM LOUVERS
A. Horizontal Drainable-Blade Louver:
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. All-Lite Architectural Products.
b. American Warming and Ventilating; a Mestek Architectural Group company.
c. Arrow United Industries.
d. Construction Specialties, Inc.
e. Greenheck Fan Corporation.
f. Industrial Louvers Inc.
g. Ruskin Company.
2. Louver Depth: 6 inches.
3. Frame and Blade Nominal Thickness: Not less than 0.080 inch.
4. Louver Performance Ratings:
a. Free Area: Not less than 8.0 sq. ft. for 48-inch- wide by 48-inch- high louver.
b. Point of Beginning Water Penetration: Not less than 1000 fpm.
c. Air Performance: Not more than 0.10-inch wg static pressure drop at 700-fpm free-area intake velocity.
5. AMCA Seal: Mark units with AMCA Certified Ratings Seal.
2.3 LOUVER SCREENS
A. General: Provide screen at each exterior louver.
1. Screen Location for Fixed Louvers: Interior face.
http://www.specagent.com/Lookup?ulid=7059 http://www.specagent.com/Lookup?uid=123457077673 http://www.specagent.com/Lookup?uid=123457077674 http://www.specagent.com/Lookup?uid=123457077676 http://www.specagent.com/Lookup?uid=123457077679 http://www.specagent.com/Lookup?uid=123457077681 http://www.specagent.com/Lookup?uid=123457077682 http://www.specagent.com/Lookup?uid=123457077689
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 9119 - 3
2. Screening Type: Bird screening.
B. Louver Screen Frames: Same type and form of metal as indicated for louver to which screens are attached.
C. Louver Screening for Aluminum Louvers:
1. Bird Screening: Aluminum, 1/2-inch- square mesh, 0.063-inch wire.
2.4 MATERIALS
A. Aluminum Extrusions: ASTM B 221, Alloy 6063-T5, T-52, or T6.
B. Aluminum Sheet: ASTM B 209, Alloy 3003 or 5005, with temper as required for forming, or as otherwise recommended by metal producer for required finish.
C. Fasteners: Use types and sizes to suit unit installation conditions.
1. Use Phillips flat-head screws for exposed fasteners unless otherwise indicated.
2. For fastening aluminum, use aluminum or 300 series stainless-steel fasteners.
3. For color-finished louvers, use fasteners with heads that match color of louvers.
D. Postinstalled Fasteners for Concrete and Masonry: Torque-controlled expansion anchors, fabricated from stainless-steel components, with allowable load or strength design capacities calculated according to ICC- ES AC193 and ACI 318 greater than or equal to the design load, as determined by testing according to ASTM E 488/E 488M conducted by a qualified testing agency.
E. Bituminous Paint: Cold-applied asphalt emulsion complying with ASTM D 1187/D 1187M.
2.5 FABRICATION
A. Fabricate frames, including integral sills, to fit in openings of sizes indicated, with allowances made for fabrication and installation tolerances, adjoining material tolerances, and perimeter sealant joints.
B. Maintain equal louver blade spacing to produce uniform appearance.
C. Fabricate frames, including integral sills, to fit in openings of sizes indicated, with allowances made for fabrication and installation tolerances, adjoining material tolerances, and perimeter sealant joints.
1. Frame Type: Channel unless otherwise indicated.
D. Include supports, anchorages, and accessories required for complete assembly.
E. Provide vertical mullions of type and at spacings indicated, but not more than is recommended by manufacturer, or 72 inches o.c., whichever is less.
1. Semirecessed Mullions: Where indicated, provide mullions partly recessed behind louver blades, so louver blades appear continuous. Where length of louver exceeds fabrication and handling limitations, fabricate with interlocking split mullions and close-fitting blade splices designed to permit expansion and contraction.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 08 9119 - 4
F. Provide subsills made of same material as louvers for recessed louvers.
G. Join frame members to each other and to fixed louver blades with fillet welds concealed from view unless otherwise indicated or size of louver assembly makes bolted connections between frame members necessary.
2.6 FINISHES
A. Aluminum Finishes:
1. High-Performance Organic Finish: Two-coat fluoropolymer finish complying with AAMA 2604 and containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions.
a. Color and Gloss: As selected by Architect from manufacturer's full range.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Locate and place louvers level, plumb, and at indicated alignment with adjacent work.
B. Use concealed anchorages where possible. Provide brass or lead washers fitted to screws where required to protect metal surfaces and to make a weathertight connection.
C. Provide perimeter reveals and openings of uniform width for sealants and joint fillers, as indicated.
D. Protect unpainted galvanized- and nonferrous-metal surfaces that are in contact with concrete, masonry, or dissimilar metals from corrosion and galvanic action by applying a heavy coating of bituminous paint or by separating surfaces with waterproof gaskets or nonmetallic flashing.
E. Install concealed gaskets, flashings, joint fillers, and insulation as louver installation progresses, where weathertight louver joints are required. Comply with Section 07 9200 "Joint Sealants" for sealants applied during louver installation.
3.2 ADJUSTING
A. Restore louvers damaged during installation and construction, so no evidence remains of corrective work.
If results of restoration are unsuccessful, as determined by Architect, remove damaged units and replace with new units.
END OF SECTION 08 9119
PROJECT NO. 23-106.020 GROUND-SET FLAGPOLES
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 10 7516 - 1
SECTION 10 7516 - GROUND-SET FLAGPOLES
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes ground-set flagpoles made from aluminum.
B. Owner-Furnished Material: Flags and solar light.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, dimensions of individual components and profiles, operating characteristics, fittings, accessories, and finishes for flagpoles.
B. Shop Drawings: For each flagpole.
1. Include the following
a. Plans, elevations, and attachment details. Show general arrangement, jointing, fittings, accessories, grounding, anchoring, and support.
b. Section, and details of foundation system.
C. Delegated Design Submittals: For flagpoles.
1.3 CLOSEOUT SUBMITTALS
A. Operation and Maintenance Data: For flagpoles to include in operation and maintenance manuals.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Spiral wrap flagpoles with heavy paper and enclose in a hard fiber tube or other protective container.
PART 2 - PRODUCTS
2.1 SOURCE LIMITATIONS
A. Obtain flagpoles as complete units, including fittings, accessories, bases, and anchorage devices, from single source from single manufacturer.
MATTAWAN CS - BID PACKAGE 2B - MAINTENANCE & TRANSPORTATION SERVICES 10 7516 - 2
2.2 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer, as defined in Section 01 4000 "Quality Requirements," to design flagpole assemblies.
B. Seismic Performance: Flagpole assemblies to withstand the effects of earthquake motions determined according to ASCE/SEI 7.
C. Structural Performance: Flagpole assemblies, including anchorages and supports, to withstand design loads indicated within limits and under conditions indicated.
1. Wind Loads: Determine according to NAAMM FP 1001. Basic wind speed for Project location is 100 mph.
2. Base flagpole design on polyester flags of maximum standard size suitable for use with flagpole or flag size indicated, whichever is more stringent.
2.3 ALUMINUM FLAGPOLES
A. Aluminum Flagpoles: Cone -tapered flagpoles fabricated from seamless extruded tubing complying with ASTM B241/B241M, Alloy 6063, with a minimum wall thickness of 3/16 inch.
1. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
a. Acme Lingo Flagpoles
b. American Flagpole
c. Baartol Company
d. Concord American Flagpole
e. Eder Flag Manufacturing Company, Inc
f. Ewing Flagpole Co., Inc.; Ewing Group Company
g. Morgan-Francis Flagpoles and Accessories
h. Pole-Tech Co., Inc.
i. US Flag & Flagpole Supply, LLC j.
B. Exposed Height: 35 feet. 30 feet