Manhattan - Attachment A - NYH Equipment .docx
DOCX document 26 KB Posted
- Attached to
- J012--Fire Alarm Maintenance - Inspection - Testing and Repair (Manhattan, Brooklyn and St. Albans campuses)
- Solicitation number
- 36C24221Q0146
About this file
This document contains an equipment inventory list and related federal contract opportunity notice. The equipment inventory list details the fire alarm, security, and related systems installed at multiple campuses of the New York Harbor Healthcare System, including manufacturers, models, and whether preventative maintenance and repair services are included. The related federal contract opportunity is a solicitation for fire alarm maintenance, inspection, testing and repair services at the Manhattan, Brooklyn, and St. Albans campuses. Interested vendors must submit quotes by November 12, 2020. The requirement replaces a previous solicitation and has a North American Industry Classification System code of 561621 and size standard of $22 million. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Manhattan Revised - Attachment A - NYH Equipment_.docx | DOCX document | |
| 36C24221Q0146 0001_1.docx | DOCX document | |
| Brooklyn Attachment B - EQUIPMENT INVENTORY LIST.docx | DOCX document | |
| 36C24221Q0146_1.docx | DOCX document | |
| St Albans Attachment C - EQUIPMENT INVENTORY LIST.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment A – Manhattan -Equipment Inventory List
| Equipment |
| Shop |
| Make |
| Model |
| Serial No. |
| Service calls |
included Y/N
| PM Frequency |
| PM Description |
Fire Alarm System Campus
Electrical
| Network notifier 2020 panel |
| Y |
| A |
MAINTENANCE AND INSPECTION SHALL CONSIST OF THE FOLLOWING:
1) INSPECTION OF SMOKE DETECTORS (INCLUDING DUCT DETECTORS)
2) INSPECTION OF ELECTROMECHANICAL DOOR HOLDING DEVICES
3) INSPECTION OF HEAT DETECTORS
4) INSPECTION OF MANUAL PULL STATIONS
5) INSPECTION OF AUDIBLE AND VISUAL DEVICES
6) TEST ALL CONTROL PANEL FUNCTIONS AND THEIR OUTLYING DEVICES (ANNUNCIATORS, PRINTER, CRT, AVL AND BATTERY BACKUP, ETC.)
7) ALL DEVICES SHALL BE CALIBRATED AT LEAST ANNUALLY AS REQUIRED FOR PROPER OPERATION.
ELEVATOR RECALL SUPERVISORY CHECKS SHALL TEST ALL BLDG ELEVATOR RECALLS AND ALL BLDG AUDIO/VISUALS DEVICES.
CONTRACTOR SHALL PROVIDE ALL LABOR, PARTS, AND EQUIPMENT FOR EMERGENCY REPAIR SERVICE.
| Two audio voice links |
| Y |
| A |
| Two notifier AFP 400 panels |
| Y |
| A |
| Three intelligent network annunciators |
| Y |
| A |
| Three PRN‐4 printers |
| Y |
| A |
| CRT‐2 terminal |
| Y |
| A |
| LCD‐80 annunciators |
| Y |
| A |
| Smoke detectors addressable with bases |
| Y |
| A |
| Heat detectors addressable with bases |
| Y |
| A |
| Duct detectors addressable |
| Y |
| A |
| Fan stop relays addressable |
| Y |
| A |
| Manual pull stations |
| Y |
| A |
| Door holding devices |
| Y |
| A |
| Tamper switches |
| Y |
| S |
| Water flow switches |
| Y |
| S |
| Speaker / strobes |
| Y |
| A |
| Strobe lights |
| Y |
| A |
| Simplex hardwire 4001 control panel |
| Y |
| A |
| Firestar hardwire fire control panel |
| Y |
| A |
| Shunt trip relays |
| Y |
| A |
| Notifier 500 panel |
| Y |
| A |
| Notifier 200 panel |
| Y |
| A |
| Fire pump power |
| Y |
| S |
| Fire pump running |
| Y |
| S |
| Fire pump controller |
| Y |
| S |
| Generator engine running |
| Y |
| S |
| Air pressure switches |
| Y |
| S |
| Notifier fire alarm panel |
| Y |
| A |
| Door holder relays |
| Y |
| A |
| Manual pull stations |
| Y |
| A |
| Speakers / strobes |
| Y |
| A |
| Smoke vent relays |
| Y |
| A |
| Tamper switches |
| Y |
| A |
| Door holders |
| Y |
| A |
| Fire telephones |
| Y |
| A |
| Generator monitors |
| Y |
| A |
| Duct detectors |
| Y |
| A |
| Smoke detectors |
| Y |
| A |
| Fire pump monitors |
| Y |
| A |
| Heat detectors |
| Y |
| A |
| Transponder |
| Y |
| A |
| Elevator recall relays |
| Y |
| A |
| Waterflow switches |
| Y |
| S |
| Strobes |
| Y |
| A |
Attachment A – Manhattan - Equipment Inventory List
| Equipment |
| Shop |
| Make |
| Model |
| Serial No. |
| Service calls |
included Y/N
| PM Frequency |
| PM Description |
| Shunt trip relays |
| Y |
| A |
| Fan shutdown relays |
| Y |
| A |
| Smoke hatch relays |
| Y |
| A |
| Damper relays |
| Y |
| A |
| 26smoke purge relays |
| Y |
| A |
| Sound and security relay |
| Y |
| A |