Manhattan Revised - Attachment A - NYH Equipment_.docx
DOCX document 27 KB Posted
- Attached to
- J012--Fire Alarm Maintenance - Inspection - Testing and Repair (Manhattan, Brooklyn and St. Albans campuses)
- Solicitation number
- 36C24221Q0146
About this file
This document contains an equipment inventory list and details for an upcoming federal contract solicitation. The solicitation will be for fire alarm maintenance, inspection, testing and repair services at three Department of Veterans Affairs campuses in New York. The solicitation number is 36C24221Q0146 and will be released on or before October 29, 2020, with a closing date for responses of November 11, 2020 at 11:00am EST. The required services include maintenance and inspection of various fire alarm and detection systems, devices, and equipment at the Manhattan, Brooklyn, and St. Albans campuses as detailed in the attached equipment inventory list. The North American Industry Classification System code is 561621 for security systems services and the estimated value is over $22 million.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24221Q0146 0001_1.docx | DOCX document | |
| Manhattan - Attachment A - NYH Equipment .docx | DOCX document | |
| Brooklyn Attachment B - EQUIPMENT INVENTORY LIST.docx | DOCX document | |
| 36C24221Q0146_1.docx | DOCX document | |
| St Albans Attachment C - EQUIPMENT INVENTORY LIST.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment A – Manhattan -Equipment Inventory List
| Equipment |
| Shop |
| Qty |
| Make |
| Model |
| Serial No. |
| Service calls |
included Y/N
| PM Frequency |
| PM Description |
Fire Alarm System Campus
Electrical
| Network notifier 2020 panel |
| Y |
| A |
MAINTENANCE AND INSPECTION SHALL CONSIST OF THE FOLLOWING:
1) INSPECTION OF SMOKE DETECTORS (INCLUDING DUCT DETECTORS)
2) INSPECTION OF ELECTROMECHANICAL DOOR HOLDING DEVICES
3) INSPECTION OF HEAT DETECTORS
4) INSPECTION OF MANUAL PULL STATIONS
5) INSPECTION OF AUDIBLE AND VISUAL DEVICES
6) TEST ALL CONTROL PANEL FUNCTIONS AND THEIR OUTLYING DEVICES (ANNUNCIATORS, PRINTER, CRT, AVL AND BATTERY BACKUP, ETC.)
7) ALL DEVICES SHALL BE CALIBRATED AT LEAST ANNUALLY AS REQUIRED FOR PROPER OPERATION.
ELEVATOR RECALL SUPERVISORY CHECKS SHALL TEST ALL BLDG ELEVATOR RECALLS AND ALL BLDG AUDIO/VISUALS DEVICES.
CONTRACTOR SHALL PROVIDE ALL LABOR, PARTS, AND EQUIPMENT FOR EMERGENCY REPAIR SERVICE.
| Two audio voice links |
| Y |
| A |
| Two notifier AFP 400 panels |
| Y |
| A |
| Three intelligent network annunciators |
| Y |
| A |
| Three PRN‐4 printers |
| Y |
| A |
| CRT‐2 terminal |
| Y |
| A |
| LCD‐80 annunciators |
| Y |
| A |
| Smoke detectors addressable with bases |
| Y |
| A |
| Heat detectors addressable with bases |
| Y |
| A |
| Duct detectors addressable |
| Y |
| A |
| Fan stop relays addressable |
| Y |
| A |
| Manual pull stations |
| Y |
| A |
| Door holding devices |
| Y |
| A |
| Tamper switches |
| Y |
| S |
| Water flow switches |
| Y |
| S |
| Speaker / strobes |
| Y |
| A |
| Strobe lights |
| Y |
| A |
| Simplex hardwire 4001 control panel |
| Y |
| A |
| Firestar hardwire fire control panel |
| Y |
| A |
| Shunt trip relays |
| Y |
| A |
| Notifier 500 panel |
| Y |
| A |
| Notifier 200 panel |
| Y |
| A |
| 1 |
| Fire pump power |
| Y |
| S |
| Fire pump running |
| Y |
| S |
| 1 |
| Fire pump controller |
| Y |
| S |
| Generator engine running |
| Y |
| S |
| Air pressure switches |
| Y |
| S |
| Notifier fire alarm panel |
| Y |
| A |
| Door holder relays |
| Y |
| A |
| 159 |
| Manual pull stations |
| Y |
| A |
| 199 |
| Speakers / strobes |
| Y |
| A |
| Smoke vent relays |
| Y |
| A |
| 73 |
| Tamper switches |
| Y |
| A |
| 157 |
| Door holders |
| Y |
| A |
| Fire telephones |
| Y |
| A |
| Generator monitors |
| Y |
| A |
| 70 |
| Duct detectors |
| Y |
| A |
| 346 |
| Smoke detectors |
| Y |
| A |
| 1 |
| Fire pump monitors |
| Y |
| A |
| 19 |
| Heat detectors |
| Y |
| A |
| Transponder |
| Y |
| A |
| 24 |
| Elevator recall relays |
| Y |
| A |
| 65 |
| Waterflow switches |
| Y |
| S |
| 431 |
| Strobes |
| Y |
| A |
Attachment A – Manhattan - Equipment Inventory List
| Equipment |
| Shop |
| Make |
| Model |
| Serial No. |
| Service calls |
included Y/N
| PM Frequency |
| PM Description |
| Shunt trip relays |
| Y |
| A |
| 150 |
| Fan shutdown relays |
| Y |
| A |
| 150 |
| Smoke hatch relays |
| Y |
| A |
| 27 |
| Damper relays |
| Y |
| A |
| 26smoke purge relays |
| Y |
| A |
| Sound and security relay |
| Y |
| A |
File details come from the government source that posted it. Updated .